| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.2 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹28.3 L+₹1.7 L (6.48%)Rejected-Finance | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹28.9 L+₹2.4 L (8.86%)Rejected-Finance 695 NEAR ANJALI CLINIC SHIV PALACE SHANTI VIHAR BADAUN ROAD SUBHASH NAGAR BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹29.5 L+₹2.9 L (11.0%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹29.8 L+₹3.3 L (12.3%)Rejected-Finance 35 A 60 RAMPUR GARDEN BAREILLY UP | BAREILLY | BAREILLY | UP | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹46.8 L
EMD Value
₹93,500
Closing Date
29 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR TO CHAJJAS, FACIA, LINTEL, PARAPETS IN CERTAIN OTM AND MD ACCN IN ZONE I TO IV UNDER AGE B/R - II OF GE (WEST) BAREILLY.
2023_MES_600894_1
8129/C/8
Open Tender
Civil Works
Item Rate
270 days
GE WEST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹93,500
Yes
19 Aug 2023
3 Jun 2023
1 Jul 2023
3 Jun 2023
29 Jun 2023
17 Jun 2023
Amount
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in chajjas and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in fins, fascias, louvers, parapets and railings exc. 60 cm in height, newels, balustrade and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges in rough finished surface of concrete complete all as specified and directed.
M & L for use and waste of form work to fins, louvers, fascia and the like in rough finished surface of concrete complete all as specified and directed.
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for cutting chases for hanging chajja, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, lintels, shelves, chajja and the like and making good on RCC / brick walls, cutting exc. 10 cm but not exc. 40 cm in girth complete all as specified and directed. NOTE- Work to be carried out upto 3rd floor of the building.
Dismantling of concrete by chiseling from RCC members like column, beam, parapet, facia, chajja, ceiling etc. exposing the reinforcement without disturbing the reinforcement, making free from rust by sand blasting / using chemical, apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement providing at places additional reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mm x 50 mm (10 mm gauge welded mesh ) and tack, securing with clips / binding wire, welding & provision guniting pressure 2.2 to 2.5 kg /Sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work and scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @ 200 ml every 50 kg of cement and applying two coat of Dr. fixit / pidilite new coat ezee at interval of 8 hours cure for the surfaces complete all as specified and directed. MAKE OF WPC- Dr. Fixit (Pidiproof LW+ or pidicrete URP)
Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks, straight or curved on plan and any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M & L for providing PCC 1:2:4 Type B-0 (using 12.5 mm graded stone aggregate) as in levelling course, haunching, coping, curved filllet and similar works of over RCC roof surface including rounded or chamferred on edges complete all as specified and directed.
M & L for rendering 10 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and fair complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including supply and mixing of liquid water proofing compound @ 200 ml per 50 kg of cement on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:3 finished even and fair complete all as specified and directed.
M & L for rendering 10 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and fair with and including taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including supply and mixing of liquid water proofing compound @ 200 ml per 50 kg of cement on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement with and including taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 5 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:3 finished even and fair with and including taking down cement or cement lime plaster from concrete ceiling including scrubbing down with water etc.complete all as specified and directed.
M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling, chajja, soffit of stair case etc. and applying three coats of white wash complete all as specified and directed.
M & L for applying 2 mm thick layer of wall care putty, rubbing down the wall / ceiling surface with sand paper after getting dried to obtain a smooth and even surface complete all as specified and directed.
M & L for preparing old decorated wall surfaces and applying one coat of cement base paint complete all as specified and directed.
M & L for preparation of old distempered surface of walls including plugging nail holes with cement based putty, making good surface to match existing surface and applying one coat of oil bound distemper complete all as specified and directed.
Dismantling of roof terracing, cement mortar, brick padding, concrete (un-reinforced) alongwith existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all loose dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material outside of MOD land complete all as specified and directed.
M & L for 40 mm thick plain cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in floor finishes even and rough to receive floor tiles complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including supply and mixing of liquid water proofing compound @ 200 ml per 50 kg of cement over concrete roof surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
M & L for providing polyester based waterproofing membrane (IWL Hyperplas Polyster manufactured by IWL, Super Thermolay manufactured by STP Limited, Torch Shield AP manufactured by Pidilite Industries) minimum weighing 3.50 Kg per sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 Grams per sqm) laid by forced torch application having minimum 10 cm end laps both ways, over and including polymeric primer @ 0.30 Litre per sqm and polymeric modified bitumen @ 1.20 Kg per square metre after cleaning of roof surface complete all as specified and directed.
M & L for machine pressed chequered cement concrete tiles of size 250 X 250 X 22 mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 15 mm thick screed bed in cement mortar 1:4 on roof top complete all as specified and directed.
M & L for applying one coats of Bitumen based UV reflective and water proofing paint with aluminium finish over APP membrane and maximum coverage 8.00 Sqm per litre per coat on non assessible roof over APP membrance complete all as specified and directed. MAKE- STP Ltd Brand-Super silver Shield or equivalent quality.
Disconnecting existing tank exc. 250 Litre but not exc. 500 Litre capacity, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position (cleaning, repairing etc. to be measured separately) complete all as specified and directed.
Disconnecting existing tank exc. 500 Litre but not exc. 1000 Litre capacity, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position (cleaning, repairing etc. to be measured separately) complete all as specified and directed.
S & F in repairs 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connection complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connection complete all as specified and directed.
S & F of 15 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F of 20 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
Re-fixing of 15 mm bore old steel water tubing and connection in new or old position (wall, ceiling, floors etc) including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
Re-fixing of 20 mm bore old steel water tubing and connection in new or old position (wall, ceiling, floors etc) including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. NOTE: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THIS ITEM.
S & F in repairs of 20 mm bore gunmetal globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls or laid under floors including dismantling of old unserviceable one complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
S & F of 3 mm thick figured glass, pin head type and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
S & F in repairs galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
M & L as in repairs mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe-290 Grade E-165 complete all as specified and directed.
Notes:- (a) Material not included in schedule of credit and debris from the dismantling having lowest value / Nil value shall be the property of department. The same shall be removed / disposed or deposited by the contractor in MES stores yard of GE (West) Bareilly as directed for which no additional payment shall be made. The contracotor shall be fully responsible to safe guard these materials against loss / theft / deterioration etc. till the same to be deposited by him in MES Store yard. (b) The contractor or his authorized representative shall attend office of AGE B/R for collection of complaints raised by user on regular basis and same has to be rectified / completed on requirement basis. If the contractors unable to rectify the complaints within stipulated time of 7 days (Maximum), penalty will be imposed to the contractor at the rate of Rs 500.00 per day for each complaint. (c) The above aspects shall be borne in mind by the tenderer while quoting the rates. The rates quoted by the tenderer shall be deemed to include the above aspects. (d) Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
M/S Alam Construction Co
SURYA CONSTRUCTION
Mohit Enterprises
M/S Shree Sai Builders
RIYASAT ALI KHAN
S S CONSTRUCTION CO
Jain construction co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .