| 1 | L1₹16.9 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹19.3 L+₹2.4 L (13.9%)Rejected-AOC | L2 | Rejected-AOC Being not L1 Bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR TO CAPACITORS APFC PANELS AND RELATED EM WORKS AT AF STN JODHPUR
2023_MES_577247_2
8543/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE (AF) Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹30,000
27 Mar 2023
24 Feb 2023
18 Mar 2023
24 Feb 2023
16 Mar 2023
4 Mar 2023
Amount
Repair and servicing of APFC panel of capacity upto 200 KVAR including rewiring of panel with 2.5 sqmm FRLS copper wire, reconnection of capacitor with necessary size of copper wire, replacement of unserveciable contactors, relays, capacitors, indicating lamps, MCBs, thyristor module, CTs, auto manual switch, push button, SMPS , SCRs, cooling fan etc and including painting of APFC Panel with two coats of synthetic enamel paint, cleaning of dust inside the panel from electric blower, cleaning of contactors, welding work for broken door, panel, relays junction points / connectors servicing, overhauling of cooling fan, complete testing of APFC relay including necessary setting with CTs load adjustment to match set the power factor in range between 0.96 to 0.99. complete all as directed as specified by Engr in Charge. Note:- All unserveciable Items replaced under repair and servicing of APFC panel shall be measured and paid separately as "supply only" as described hereinafter in respective items.
Supply only capacitor duty contactor heavy duty type 3 pole AC of capacity having coil voltage 250 volt up to 10 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by the Engineer-in-Charge.
Supply only of capacitor duty contactor heavy duty type AC of capacity having coil voltage 250 volt 15KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by the Engineer-in-Charge.
Supply only capacitor duty contactor heavy duty type AC of capacity having coil voltage 250 volt 20 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by the Engineer-in-Charge.
Supply only of capacitor duty contactor heavy duty type AC of capacity having coil voltage 250 volt 25KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by the Engineer-in-Charge.
Supply only of capacitor duty contactor heavy duty type AC of capacity having coil voltage 250 volt 30 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by the Engineer-in-Charge.
Supply only APFC relay/PLC source type with protection device intelligent automatic processor has on electric controller unit up to 12 stage for contactor type APFC panel and thyristor based APFC panel with 3 CT input complete all as specified and directed by the Engineer-in-Charge. Make:- as per existing at site.
Supply only of CT coil suitable for ampere meter 100/5 amp ratio complete all as specified and directed by the Engineer-in-Charge. (Make:- AE/ ENERCON/ EPCOS)
Supply only of CT coil suitable for amp meter 200/5 amp ratio complete all as specified and directed by the Engineer-in-Charge. (Make:- AE/ ENERCON/ EPCOS)
Supply only of CT coil suitable for amp meter 400/5 amp ratio complete all as specified and directed by the Engineer-in-Charge. (Make:- AE/ ENERCON/ EPCOS)
Supply only ELECRTONIC THYRISTOR MODULE of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt 05 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by the Engineer-in-Charge.
Supply only ELECRTONIC THYRISTOR MODULE of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt 10 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by the Engineer-in-Charge.
Supply only ELECRTONIC THYRISTOR MODULE of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt above 20 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by the Engineer-in-Charge.
Supply only ELECRTONIC THYRISTOR MODULE of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt above 25 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by the Engineer-in-Charge.
Supply only of MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 10 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only of MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 12.5 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only of MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 15 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 20 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 25 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 30 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 7.5 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 5 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 2 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 1 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only MPP capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 3 KVAR cylindrical type gas filled complete all as specified and directed by the Engineer-in-Charge.
Supply only of SCRs used in thyrister switching suitable for upto 200 KVAR APFC panel complete all as specified and directed by the Engineer-in-Charge.
Supply only of SMPS 220 V AC input used in APFC panel complete all as specified and directed by the Engineer-in-Charge.
Supply only MCB TP 450 volts 10 KA 'C' curve type of capacity 32 ampere complete all as specified and directed by the Engineer-in-Charge.
Supply only MCB TP 450 volts 10 KA 'C' curve type of capacity 63 amp complete all as specified and directed by the Engineer-in-Charge.
Supply only push button red / green for on and off including connection for capacitors complete all as specified and directed by the Engineer-in-Charge.
Supply only indicating lamp RYB including connection for capacitors complete all as specified and directed by the Engineer-in-Charge.
Supply only Auto manual switch for APFC panel complete all as specified and directed by the Engineer-in-Charge.
Supply only cooling fan used in APFC panel of capacity and make as existing at site complete all as specified and directed by the Engineer-in-Charge.
M/s R K Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .