Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹78,109Accepted-AOC | 1st | Accepted-AOC First lowest | |
| 2 | 2nd₹91,257.04+₹10,000 (12.3%)Rejected-Finance THRISSUR KERALA KL | PALAKKAD | KERALA | 678001 | 2nd | Rejected-Finance Second lowest |
| Sl No | Description | Qty | Unit | BASTIN VINCENT L1 | Paulson M I L2 |
|---|---|---|---|---|---|
| 1.00Electrification | |||||
| 1.00 | OD26031/2025-2026:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III fixed head frame including round arm luminary carrage suitable for 4/6 luminare, foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 5 Meters | 1 | each | 20,875.69 ₹20,875.69 Lowest | 30,875.69 ₹30,875.69 |
| 1.00 | 90.2.2.3:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Single control light point without ceiling rose - Short point | 3 | point | 658.84 ₹1,976.52 Lowest | 658.84 ₹1,976.52 Lowest |
| 1.00 | 90.2.2.6:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points. | 1 | each | 359.41 ₹359.41 Lowest | 359.41 ₹359.41 Lowest |
| 1.00 | OD26042/2025-2026:Supply Conveyance, installation, testing and commissioning of 12W LED B H (LBKOVSL 12 Luker/equivlent make ), duly wired up for use on 230 V AC supply. | 2 | each | 936.9 ₹1,873.8 Lowest | 936.9 ₹1,873.8 Lowest |
| 1.00 | OD26043/2025-2026:Supply and providing 7/9 W LED bulb on the existing fitting etc as requiredd (havells,crompton/bajaj/philips/equivlent make) | 1 | each | 134.23 ₹134.23 Lowest | 134.23 ₹134.23 Lowest |
| 1.01 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. | 1 | each | 126.42 ₹126.42 Lowest | 126.42 ₹126.42 Lowest |
| 1.01 | OD26026/2025-2026:Supplying and providing analog time switch 3 module L&t/ equivlent in the existing panel and giving connection etc. as required. | 1 | each | 4,966.2 ₹4,966.2 Lowest | 4,966.2 ₹4,966.2 Lowest |
| 1.01 | OD26036/2025-2026:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light (ALCOR LN5Y of Luker-5 year warranty/equivlent make ), duly wired up for use on 230 V AC supply. | 2 | each | 6,726.49 ₹13,452.98 Lowest | 6,726.49 ₹13,452.98 Lowest |
| 1.01 | OD26038/2025-2026:Supply Conveyance, installation, testing and commissioning of 50W LED Flood light (ALCOR LN5Y of Luker-5 year warranty/equivlent make ), duly wired up for use on 230 V AC supply. | 1 | each | 4,492.09 ₹4,492.09 Lowest | 4,492.09 ₹4,492.09 Lowest |
Tender Value
₹81,257
EMD Value
₹2,031
Closing Date
28 Jun 2025, 11:00 amClosed
Assistant Engineer
The Assistant Engineer, LSGD Section, Karalam Grama Panchayat
Electricfication
2025_LSGD_770278_1
T2/AE/LIDEW/KRLM/2025-26
Open Tender
Electrical Works
Item Rate
180 days
Karalam GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹2,031
Yes
7 Aug 2025
20 Jun 2025
30 Jun 2025
20 Jun 2025
28 Jun 2025
20 Jun 2025
Amount
Electrification
OD26031/2025-2026:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III fixed head frame including round arm luminary carrage suitable for 4/6 luminare, foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 5 Meters
90.2.2.3:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.2.6:Supply and wiring points according to IS 732-1989 through the existing conduit with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (Group B/ RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
OD26042/2025-2026:Supply Conveyance, installation, testing and commissioning of 12W LED B H (LBKOVSL 12 Luker/equivlent make ), duly wired up for use on 230 V AC supply.
OD26043/2025-2026:Supply and providing 7/9 W LED bulb on the existing fitting etc as requiredd (havells,crompton/bajaj/philips/equivlent make)
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD26026/2025-2026:Supplying and providing analog time switch 3 module L&t/ equivlent in the existing panel and giving connection etc. as required.
OD26036/2025-2026:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light (ALCOR LN5Y of Luker-5 year warranty/equivlent make ), duly wired up for use on 230 V AC supply.
OD26038/2025-2026:Supply Conveyance, installation, testing and commissioning of 50W LED Flood light (ALCOR LN5Y of Luker-5 year warranty/equivlent make ), duly wired up for use on 230 V AC supply.
OD26037/2025-2026:Supply & fixing 2 pole power contactor L&T make MNX -2P and giving connectin etc as required
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
OD26027/2025-2026:Steel reinforcment work fo RCC work including straightening,cuttung bending and placing in position with binding etc as required.
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
OD26044/2025-2026: Supplying and providing copper earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required.4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD26166/2025-2026:Supply and providing junction box -Sintex make GS JB 2525/equivlent on surface/recess and making good the damages ,colour washing etc as required .
90.3.17.2:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.40 mm dia GI pipe
90.3.18.2:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
OD26032/2025-2026: Supply and provding test joint for earthing system using 2 nos of the following strips including cutting and bending to shape ,drilling necessary holes and fixing to the watering pipe etc as required .2x25x6 mm GI strip
OD26175/2025-2026:Supply and providing Gully trap with cover box of cast iron on the existing masonery work of the earth pit including providing charcole and salt mixed with soil around the earth pipe and making the earth in good condition etc as reqiored.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD26033/2025-2026:Supply and providing the following sizes of bolt and nut with washers on the existing M.S box/ earth bus etc. as required including drilling necessary holes as required. 25x6mm brass nut and bolt .
OD26028/2025-2026:Supply and fixing the following accessories in the existing board and giving connections etc. 32A 2 way Neutral link mounted on DMC/ SMC base
OD26035/2025-2026:Supply and fixing the following accessories in the existing board and giving connections etc. 32A HRC Fuse Base with HRC Fuse link
OD26029/2025-2026:Supply and installation of dust and vermin proof wall mounting SMC Meter box suitable for fixing KSEB Meter, cut out Neutral link etc, hinged door construction for the front side , providing vision panel, for the meter compartment, knock out for cable entry and exit. GS-MB 4537 (inside 450x370x200mm) Sintex or its equivalent.
OD26034/2025-2026:Preparing completion and test certificates for KSEB connection
Paulson M I (BID ID -2234914)
Bidder Name
BASTIN VINCENT
Paulson M I
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1256732.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .