| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹15.2 LAccepted-AOC BOXIBAZAR MIDNAPORE | MIDNAPORE | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | ₹15.2 L | 1st | Accepted-AOC Ok |
| 2 | 2nd₹15.2 LRejected-AOC 15 JAWAHARLAL NEHRU ROAD SEGUNBAGAN P O KRISHNAGAR DIST NADIA W B PIN 741101 | KRISHNAGAR | NADIA | WEST BENGAL | 741101 | ₹15.2 L | 2nd | Rejected-AOC Letter of Acceptance issued of 1st Lowest |
| 3 | 3rd₹15.3 LRejected-AOC VILL CHANDITALA PANPARA P O CHANDITALA DIST HOOGHLY | HOOGHLY | ₹15.3 L | 3rd | Rejected-AOC Letter of Acceptance issued of 1st Lowest |
Tender Value
₹15.2 L
EMD Value
₹30,478
Closing Date
3 Feb 2026, 2:00 pmClosed
Executive Engineer
Krishnagar Division, Social Sector, P.W.Dte., Kanthalpota, Krishnagar, Nadia
Construction of First Floor of the Library Extension Building of Nabadwip Vidyasagar College at Nabadwip in the district of Nadia
2026_WBPWD_989889_1
WBPWD/SS/EE/KNG- 20(e)/2025-26
Open Tender
CIVIL WORKS
90 days
Krishnagar
Please refer Tender documents.
6 documents required · 6 mandatory
₹30,478
Yes
10 Feb 2026
16 Jan 2026
5 Feb 2026
20 Jan 2026
3 Feb 2026
20 Jan 2026
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m a) In First floor including roof.
Dismantling R.C. floor, roof, beams etc.including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In First floor including roof.
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] M 25 Grade (i) Pakur Variety M-25 (i) In 1st Floor
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) In 1st Floor
(ii) In 2nd Floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work (ii) In 1st Floor
(iii) In 2nd Floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel (TATA/SAIL/RINL) (ii) In 1st Floor
(iii) In 2nd Floor
Brick work with 1st class bricks in cement mortar (1:6) (b) In Superstructure (ii) In 1st Floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4). (ii) In 1st Floor
In 2nd Floor
Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (a)Size not Iess than 600mmX 600 mm X 9.5 mm thick) (ii) In 1st Floor
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (a) Sal : Malayasian (ii) In 1st Floor
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (a) 40mm X 6mm, 250mm Length
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35mm thick shutters (single leaf) (ii) In 1st Floor
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vii) 100mm. X 58mm. X 1.90mm.
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed. (a) 300mm x 16mm dia bolt.
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (ix) 300mm long x 10mm dia. bolt.
ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type
Supplying 'Godrej' mortice lock chromium plated with keys 6levers including fitting & fixing complete.
Anodised aliminium D type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed. (a) With continuous (Hexagonal / Round rod) plate base. (vii) 150 mm grip x 12 mm dia rod. (i) 150 mm grip x 12 mm dia rod.
Supplying, fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr.
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. iv) 5mm thick coloured / tinted / smoke glass.
Supplying maruti lock (100mm)
Supplying PVC rollers for sliding windows as per direction of Engineer in charge.
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. (ii) In 1st Floor
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (i) With 1:6 cement mortar; (b) 20 mm thick plaster (ii) In First Floor
In Second Floor
(A) With 1:6 cement mortar (c) 15 mm thick plaster (ii) In 1st Floor
In 2nd floor
(B) With 1:4 cement mortar (a) 10 mm thick plaster In 1st Floor
Labour for Chipping of concrete surface before taking up Plastering work.
Rendering the surface of walls and ceiling with white cement based WATER PROOF wall putty of approved make and brand(1.5mm thick) First Floor
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (a) One Coat i) Water based interior grade Acrylic Primer In ground floor (a) One Coat; i) Water based interior grade Acrylic Primer
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (a) One Coat In 1st floor ( same as out side plaster area)
In 2nd floor ( same as out side plaster area)
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat) b) Premium 100% Acrylic Emulsion In 1st floor
In 2nd floor
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with ready mixed red lead paint of approved make and brand : (a) One coat
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any ahade except white) (b) On steel or other metal surface :With super gloss (hi-gloss) - (iv) Two coats (with any ahade except white)
(a) On timber or plastered surface : With super gloss (hi-gloss) - (iv) Two coats (with any ahade except white)
Supplying, fitting & fixing UPVC pipes A Type and fittings conforming to IS:13592 1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M Seal etc) complete. (A) UPVC Pipes: (iii) 160 mm. Dia.
(B) UPVC Fittings: (a) Plain Tee (iii) 160 mm. Dia.
(d) Shoe (iii) 160 mm. Dia.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
WBF-2911.pdf
Tender Documents • 0.53 MB
SPECIALTERMS.pdf
Tender Documents • 0.68 MB
BOQ_2419001.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid