Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹33,511
Closing Date
31 Oct 2020, 2:55 pmClosed
EE(E)
BSNL ELECT.DN., CTO BLDG., CTO COMPOUND, CIVIL LINES, NAGPUR - 440 001
CMC of E/A sets above 30kVA and split AC units and maintenance of EA sets below 30kVA on call basis in SSA Beed RECALLED 1st).
2020_BSNL_590923_1
23/CEE/BSNL/MHEZ/NGP/2020-21
Open Tender
Miscellaneous Services
Item Rate
730 days
BEED SSA
Please refer Tender documents.
15 documents required · 15 mandatory
₹590
AO CASH PGMT BSNL NAGPUR
₹33,511
3 Nov 2020
15 Oct 2020
3 Nov 2020
16 Oct 2020
31 Oct 2020
16 Oct 2020
16 Oct 2020 - 31 Oct 2020
Amount
SUB HEAD-I(CMC OF AC UNITS)
Comprehensive Maintenance of Window / Split / High Sensible & Package AC units of following capacity as per the terms and conditions enclosed. (i) AC units completed life less than 5 Years from the date of commissioning i) Split AC ( 1.5TR ) for First year
ii) Split AC(1.5TR ) for Second year
SUB HAED-II (CMC OF EA SETS)
CMC of EA sets completed life more than 5 Years from date of commissioning of following ratings as per the terms and conditions enclosed. i) More than 20 kVA to 45 kVA EA a) 1st Year
b) 2nd Year
ii) More than 45 kVA to 75 kVA EA a) 1st Year
b) 2nd Year
ii) More than 75 kVA to 100 kVA EA a) 1st Year
b) 2nd Year
ii) 125 KVA EA a) 1st Year
b) 2nd Year
ii) 200 kVA EA a) 1st Year
b) 2nd Year
Servicing & Routine maintenance (B check) of following capacity of EA set complete with cleaning of Air Filter element, replacement of engine lube oil of proper grade (seal pack of reputed make), replacement of lube oil filter elements, replacement of fuel filter elements, if required replacement of radiator coolant with distilled water & addition of coolant additive concentrate, Checking & reset injector pressure, injector pump timing, tightening of cylinder head studs/nuts, adjustment of engine valve clearance, Cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, air piping, belt tensions i/c cleaning & de-dusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc. Actual load testing of EA set after servicing as directed. ["B" check once in 12 months] i) More than 20 kVA to 45 kVA EA
ii) More than 45 kVA to 75 kVA EA
ii) More than 75 kVA to 100 KVA EA
ii) 125 kVA EA
ii) 200 KVA EA
Supplying & fixing of fully charged 12 volt lead acid Maintenance Free battery of following rating for starting of EA set complete with end lugs etc NOTE:- Battery replacement once during currency of contract after considering rebate for old battery for quoting rate. i)130 AH
iii) 180 AH
SUB HAED-III (MTCE. OF EA SETS ON CALL BASIS)
Attending complaint and checking of faults of EA set by skilled technician, rectification of minor faults/wiring/lubricating etc. as reqd for the following distance of one side from Sub Divisional Office. This item shall be paid once in 4 months period. Any subsequent visit required shall be borne by the firm within stipulated period of 4 months. (i) Upto 50 kms
(ii) Above 50 to 100 kms
Servicing & Routine maintenance (B-Check) of following capacity of EA set complete with cleaning of Air Filter element, replacement of engine lube oil of proper grade (seal pack of reputed make), lube oil filter & fuel filter elements, radiator coolant with distilled water & addition of coolant additive concentrate, Checking & reset injector pressure & pump timing, tightening of cylinder head studs, adjustment of engine valve clearance, cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, air piping, belt tensions i/c cleaning & de-dusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc. Actual load testing of EA set after servicing as directed. ["B" check once in 12 months] i) Upto & including 20 kVA EA
ii) More than 20 kVA to below 30 kVA EA
Supplying & fixing of fully charged 12 volt 88AH battery for starting of EA set complete with lugs (i/c credit of old battery) of following types:- (i) Lead acid Maintenance Free battery
(ii) Super Capacitors 120F battery suitable upto 25kVA DG cranking system
Replacement of following by new components of EA sets below 30 kVA i/c fixing/connections, testing etc. i/c credit for old material as reqd.
Below 30 kVA EA set (i) Oil top up ( with recommeded grade & make)
(ii) Pump caliberation from authorised dealer (with out nozzle replacement)
(iii)Starter repair i/c replacement of spares
(iv) Charging alternator repair i/c replacement of spares
(v)Fuel inlet / outlet pipe
(vi)Gasket kit excluding sump kit
(vii)Automatic voltage regulator (AVR)
(viii)Mains / DG contactor
(ix)32 A TPN MCB 'C' curve
(x)63 A FP isolator
(xi)LED Lamp indication lamp
(xii)Stop solenoid
(xiii)Push button
(xiv)Voltmeter
(xv) Ampere Meter
(xvi)Oil pressure meter
(xvii)Water temp meter
(xviii) Oil temp meter
(xix) Oil pressure pipe
(xx)SMPS 12 volt, 10 Amp Battery Charger
(xxi)Hose kit
(xxii)Fan belt
(xxiii)Water pump assembly
(xxiv)LLOP switch
(xxv)Water Temperature Switch 96 Deg.
(xxvi)Exhaust Below
(xxvii)Door Hinges
(xxviii)Relay Card (Start & Stop)
(xxix)Key Switch
(xxx)Air Filter
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .