Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹38.6 L+₹2.2 L (6.17%)Rejected-Finance 110B CIVIL LINES BAREILLY 243001 UP | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance Not being lowest tenderer | |
| 3 | L3₹40.9 L+₹4.5 L (12.4%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Sept 2022, 6:00 pmClosed
GE RANIKHET
GE MES RANIKHET
REPAIR MAINTENANCE OF BR AND EM WORKS FOR RUNWAY AIR FIELD MAINTENANCE AND CERTAIN REPAIR WORKS IN MD AND OTM ACCN AT HALDWANI UNDER GE RANIKHET
2022_MES_548832_1
GE/RKT/47 OF 2022-23
Open Tender
Civil Works
Works
180 days
Haldwani under GE Ranikhet
As per NIT
6 documents required · 6 mandatory
₹500
GE RANIKHET
₹90,000
31 Oct 2022
30 Aug 2022
4 Oct 2022
30 Aug 2022
27 Sept 2022
13 Sept 2022
Amount
BOQ ( Sch 'A') B/R items Demolition of brick work or stone masonry or precast PCC block walling built in cement mortar complete all as specified and directed.
Demolition of cement concrete ( unreinforced) in ground floors and pavings incuding terrazzo topping n.exc 15cm thickness (below or above ground level) and disposal of unserviceable materials, debris and rubish to a distance not exc 50m as directed by Engr-in-Charge complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc or for manholes cesspits, shafts etc not exc 10 sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Returning, fillingin, including spreading, levelling , watering and well ramming in layers not exc 25 cm thick in hard/ dense soil complete all as specified and directed.
Removing excavated material (soil) to a distance n.exc 50 m and depositing where directed at a level n.exc 1.50 m above the starting point complete all as specifed and directed.
Material & Labour for brick work with sub class `B’ bricks, using old size bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed.
Material & Labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilitate demolition complete all as specified and directed.
M&L for RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in Slab supported on walls,beams and columns in floors,roof, landing, balconies, complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slab, floor slabs, landings etc and rough finished surfaces of concrete flat complete all as specified and directed.
M&L for precast reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:6 including necessary form work complete all as specified and directed (reinforcement to be measured separately) complete all as specified and directed.
M & L for mild steel TMT bars ,10mm dia and over , cut to length , bent to shspe required incl cranking , bending spirally for hooping for coloumns , hooking ends and binding with MS wire (annealed) not less than 0.90 mm dia all a specified and directed
Material and labour cement concrete 1:1.5:3 A1 (using 20mm graded crushed stone aggregate) as in floor , pavement, hard standing etc including broom finish complete all as spcified and directed.
M&L for Forming contraction (Dummy) joints 65mm deep x 10mm wide, filled with ceiling compound grade 'A' complete all as spcified and directed.
Taking down cement or cement lime plaster of any description on brick or PCC blocks or stone wall or concrete surface etc including raking out joints, hacking for keys, scrubbing down with water etc and removing rubbish to a dostance not exc 50 m complete all as specified and directed.
Material and labour for 15mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces using WPC where ever required as per manufacturerer's instructions and finishing the surface even and smooth (without using extra cement) etc. complete all as specified NOTE -WPC shall be measured and paid separetely.
Material & Labour for 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, finishing the surfaces fair and even complete all as specified and directed.
Material & Labour for 10mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces of ceiling, finishing the surfaces fair and even complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
Material & labour for preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as pecified and directed.
M&L for preparation of newly plastered surfaces of wall and applying a layer of wall care putty 2mm thick (averaging) , finishing walls with Acrylic Smooth exterior paint of required shade, Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed
Material & Labour for preparing newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed. .
Material & labour for preparing newly plastered or unplastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer complete all as pecified and directed.
Material & labour for preparing old decorated plastered or unplastered surfaces of ceiling and applying one coat of oil bound distemper complete all as pecified and directed.
Material & labour for preparing old decorated plastered or unplastered surfaces of walls and applying one coat of oil bound distemper complete all as pecified and directed.
Material & Labour for one coat of exterior emulsion paint (as per manufacturers instruction) on old decorated surface of wall to match the existing surface including preparation of surface complete all as specified and directed
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of primer white or tinted on old decorated/undecorated surfaces of wall complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of walls including cornices etc by brooming down with steel wire, brushing, scraping down smoke soot, moulds, masss and efflorscent salts and trading oil and greasy spots & removing of nails mark & applying one coat of cement base paint on wall to match the existing surface complete all as specified
M&L for complete removal of existing treatment and applying two coat of cement base paint over a coat of primer on old decorated/undecorated surfaces of walls complete all as specified and as directed.
Material & Labour for applying one coat of exterior emulsion paint (as per manufacturers instruction) on old decorated surface of wall to match the existing surface including preparation of surface complete all as specified and directed
Material & Labour for applying one coat of plastc emulsion paint (as per manufacturers instruction) on old decorated surface of wall to match the existing surface including preparation of surface complete all as specified and directed
Material & Labour for preparation of old painted wooden surfaces of any description,not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Material & Labour for preparation of old painted steel and iron surfaces of any description,not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Material & Labour for preparation of new or previously untreated wooden surfaces of any description,not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint incl preparation of old concrete surfaces plain or moulded, over 10 cm width or girth when unconnected with other painting or when painted in a different complete all as specified.
Material and Labour for preparation of new/old road surfaces and applying thermoplastic reflective paint in marking of minimum 2.5mm thick single coat as in centre line and edge line road marking of 150/100 mm width using 'HOT MARK' by indigenous modern propelled road marking machine as directed including all ingredients such as binder, glass beads Titanium dioxide calcium carbonate inter filler, thermoplastic requirement for glass beads shall be the table No 800.4 of MOST specification including spraying of glass beads and removing of old existing paint etc all as per manufacture's instructions complete all as specified and directed incl removal of existing paint complete as directed by Engr-in-Charge
M&L for racking out expansion, construction and dummy joints of width exceeding 08mm but n exc 15mm and required depth as specified by special tools like concrete cutter, wire/coir brushes machines and joint cleaned thoroughly with application of compressed air making free from all the loose material ie. dirt, grease existing sealing compound, filler board (as required), including sticked material of existing compound racked upto full depth (up to 40mm) of joints etc to entire satisfaction of Engr-in-Charge and filling the joint with polyurethane joint sealant compound using mechanical means with depth of joint sealig compound not less than 10 mm (depth minimum above the backup rod) complete all as specified and as directed.
M&L for racking out expansion, construction and dummy joints of width exceeding 20mm but n exc 24mm and required depth as specified by special tools like concrete cutter, wire/coir brushes machines and joint cleaned thoroughly with application of compressed air making free from all the loose material ie. dirt, grease existing sealing compound, filler board (as required), including sticked material of existing compound racked upto full depth (up to 40mm) of joints etc to entire satisfaction of Engr-in-Charge and filling the joint with polyurethane joint sealant compound using mechanical means with depth of joint sealig compound not less than 10 mm (depth minimum above the backup rod) complete all as specified and as directed.
M&L for racking out expansion, construction and dummy joints of width exceeding 25mm but n exc 29mm and required depth as specified by special tools like concrete cutter, wire/coir brushes machines and joint cleaned thoroughly with application of compressed air making free from all the loose material ie. dirt, grease existing sealing compound, filler board, backup rod (as required), including sticked material of existing compound racked upto full depth (up to 40mm) of joints etc to entire satisfaction of Engr-in-Charge and filling the joint with polyurethane joint sealant compound using mechanical means with depth of joint sealig compound not less than 10 mm (depth minimum above the backup rod) complete all as specified and as directed.
M&L for racking out expansion, construction and dummy joints of width exceeding 30mm but n exc 35mm and required depth as specified by special tools like concrete cutter, wire/coir brushes machines and joint cleaned thoroughly with application of compressed air making free from all the loose material ie. dirt, grease existing sealing compound, filler board, backup rod (as required), including sticked material of existing compound racked upto full depth (up to 40mm) of joints etc to entire satisfaction of Engr-in-Charge and filling the joint with polyurethane joint sealant compound using mechanical means with depth of joint sealig compound not less than 10 mm (depth minimum above the backup rod) complete all as specified and as directed.
M&L for repair to top cut spelled joints, broken corners and pot holes in concrete slab by chiseling/mechanical cutter to provide regular prismatic cavity with sides perpendicular and cleaning off all loose or broken materials to a distance exc 50m and not exceeding 100 meter. Cleaning and washing the surface and application of surface treatment with Epoxy of Hindustan of NG Patch complete all as specified and as directed.
M&L for 3mm thick Epoxy Polyurethane floor coating consisting of 200 micron thick priming coat 2000 microns screed coat and 1000 micron thick top coat including necessary preparation of the existing surface all as per the manufacturers instructions. Work to be carried out in patch work and to make the shade asper existing shade incl removing existing treatment if any complete all as specified and as directed.
M&L for Epoxy Polyurethane floor paint coating consisting of 200 micron thick priming coat and 1000 micron thick top coat including necessary preparation of the existing surface all as per the manufacturers instructions. Work to be carried out in patch work and to make the shade asper existing shade incl removing existing treatment if any complete all as specified and as directed.
M&L for Leak Seal Self Adhesive Water proof Sealing tape 100 mm size for water leakage fixed complete all as specified but the Work to be carried at an height upto 16 meter from FFL complete all as specified and directed. (Note. All necessary scaffolding, safety measures/ arrangements shall be made by the contractor at his own cost and quoted rate shall deemed to be included this aspect and nothing extra shall be admissible on this account.)
S&F PVC 8 to 9mm thick hollow PVC wall/ ceiling panelling including all fixing viz, U and L as design and pattern including all necessary framed works as per manufacturer s instruction , make as approved by GE complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in level course with finshining in cement concrete surface even and rough to receive screed bed complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed.
M&L for joint free non - skid coloured ceramic tiles 7 to 10 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over with and including screed bed of 15 mm thick in CM 1:6 and pointed in white or coloured cement to match complete all as specified.
M&L for glazed coloured ceramic tiles as in verticle surfaces 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match with and including screed bed or bedding layer 10mm thick in CM 1:4 and pointed in white or coloured cement to match complete all as specified..
M&L for virified tiles 8 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and hite or coloured cement to match as in floors etc. set and jointed in neat cement slurry over with and including screed bed of 15 mm thick in CM 1:6 and pointed in white or coloured cement to match as in floor etc , all as specified.
M&L for virified tiles 8 to 10 mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in verticle surfaces etc etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over with and including screed bed or bedding layer 10mm thick in CM 1:4 on vertical surfaces/skirting complete all as specified and as directed
M&L for vitrified parking tiles thickness not less than 10 mm light shade (square/ rectangular) polished, area of each tiles not exc 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over with and including 15 mm thick screed bed or bedding Layer in cement mortar 1:6 complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10cm girth.
Taking up or down GI water tubing 15mm dia (bore) including connections and fittings, complete all as specified and as directed.
Supply and laying steel water tubing 15mm dia (bore), galvanised, ‘medium grade’ with and including all GI fittings, fixed on walls, ceiling or laid in floors or any other Situation, complete as all specified and as directed.
Dismantling water tanks of capacity exc 500 but not exc 1000 ltrs complete all as specified and directed
Supply & fixing rotational moulded polythene water storage tanks tripple layer (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity with and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
S&F in repairs PVC Connections 15mm size with PTMT Nuts of length 450mm and fixed, complete all as specified and as directed.
S&F in repairs one piece floor mounted vitreous china EWC with integrated flushing cistern, soft closing seat cover and necessary nut/bolt for fixing complete all as specified and as directed by Engr-in-Charge
S&F in repairs white wash hand basin of vitreous china counter sunk size 560mm x 410mm x 180mm, PVC waste pipe 32mm dia, waste coupling brass chromium plated and including cutting complete all as specified and directed.
S&F in repairs vitreous China urinal, full stall type, including, urinal spreader, waste coupling and waste pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, grating and union for discharge pipe complete all as specified and as directed.
Material & Labour for 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in subbase finished even and rough complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 20mm graded stone aggregate as in pavings, plinth protection with and including all necessary form work & finishing surface even & smooth with using extra cement complete all as specified and as directed.
S&F MS mortice lock vertical type, 4 lever of size 100mm complete all as specified and as directed.
S&F door closer aluminium extruded section hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and as directed.
S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty incl making hole and fixing with complete all as specified and as directed.
Taking down chowkats or frames exc 1.50 sqm but n.exc 4.00sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down shutters of any description exc 1 sqm but not exc 2Sqm each complete all as specified and as directed.
Taking down of existing aluminium door of any description including renewal of unserviceable parts and refixing in the same opening complete all as specified and as directed.
M&L for 16 to 18mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete over with and including cement screed bed 15mm thick in CM 1:4, complete all as specified and directed.
S&F 12 mm thick toughned glass door with patch fittings with cover plate of SS-304 grade including decorative type Stainless steel 304 grade floor Spring, fixing/moving arrangement at top, Stainless steel 2 Nos H Type Handles of 450 MM suitable size as directed, Fin Connect Patch Lock etc in each door, including cutting holes in any size in floor and wall complete all as specified and as directed.
M&L for complete removal of existing APP membrane and providing APP based polymeric membrane minimum weighing 3.60Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric ( weight not less than 150 gms /sqm ) laid on bituminous surfaces by forced application over entire roof area, sunken portion with side lap not less 100mm and end lap not less than 150mm incl apply a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm over a coat of bitumen primer @ 0.30 Kg/ sqm including cleaning surfaces etc complete all as specified and as directed.
S&F powder coated anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
S&F 4.8mm thick sheet glass (tinted glass) and glazing with oil putty in squares xc 0.5 sqm in each pane complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames incl punching or drilling out glazing pins/spring clip and providing and fixing new ones complete all as specified and as directed.
S & F 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S&F 4mm thick figured glass pin headed type and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed.
S&F as in repair mild steel wire cloth, 0.45 mm nominal dia of wire and average width of aperature 1.4 mm and fixed with alluminium staple/tinted tacks and around all beading complete all as specified and as directed
M&L for providing PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops rouded or chamfered on edges complete all as specifed and directed.
S&F 150 mm overall length floor stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed
S&F as in repairs stainless steel decorative tubular curtain rail of 25mm dia including six nos curtain ring per running mtr and one number of brackets on each end and one number of globe on each end of the rod per opening of door / window complete all as specified and directed.
S&F 18mm thick veneered decorative plywood , grade - 1 (with BWR resin ) with decorative face venners on both faces fixed with screws to timber frame work, colour and pattern as approved including external teak wood lipping complete complete all as specified and directed.
M&L for stainless steel telescopic channel for drawers not less than 45 cm long complete all as specified and directed.
S&F Push to open magnetic catches for kitchen cabinet doors complete all as specified and directed.
S&F stainless steel sensys soft close 0 crank concealed slide on cabinet Hinge, a base of 12.5 (crank 0 degree) with mounting plate (shutter thickness 15-24mm) complete all as specified and directed
S&F Stainless Steel Decorative Cabinet Handle 100 mm complete all as specified and directed
Re-fixing galvalume aluminium zinc coating GI based plain/corruagated steel sheeting in any size and design old sheets any make and material, any size , gauge as in as in roof, ridge , vallley gutter, including provn of screws, tapping screws any size including washers, drilling counter shank complete all as specified and directed. but the Work to be carried at an height of more than 4 m and upto 16 meter from FFL . (Note. All necessary scaffolding, safety measures/ arrangements shall be made by the contractor at his own expensis and quoted rate shall deemed to be included this aspect and nothing extra shall be admissible on this account.)
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
S&F rolled sections channel angle tee section and in tubular section as in main and cross beams, hip and jack rafters; purlins,post where connected to common rafters and running rails and embbeded in concrete, Fe 410-W (grade-E-250) quality-A complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern or any other pattern roof coverings complete all as specified and as directed.
S&F prepainted aluminium zinc steel sheet (galvalume base) or thinknee 0.50mm having tensile strength of 550 Mpa , in colour and profile as apporved by GE and to be factory moulded as in roof covering /cladding and fixed with hot dipped galvanished with high durable protective triple coated self tapping screws /self drilling serews, to suit the roofing in customized colour matching with the colour of roofing and screws are to be fixed using torque adjustable electronic gun screws drills of suitable capacity complete all as specified but the work to be carried upto 16 meter from FFL. (Note. All necessary scaffolding, safety measures/ arrangements shall be made by the contractor at his own expensis and quoted rate shall deemed to be included this aspect and nothing extra shall be admissible on this account.)
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge , vallley gutter , and like complete ,but the Work to be carried at an height upto 16 meter from FFL . (Note. All necessary scaffolding, safety measures/ arrangements shall be made by the contractor at his own expensis and quoted rate shall deemed to be included this aspect and nothing extra shall be admissible on this account.)
Supply & fixing in repair 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed including necessary fittings like socket, bend, elbow, single/double tee etc in any length with rubber ring joints fixed with clamps of flat iron and including bolts and nuts and securing ends of stays to wall or roof and making good with cement mortor 1:3 or with PCC 1:2:4 complete all as specified and directed.
BOQ ( Sch 'A') E/M items Taking down carefully aluminium/copper wiring of any size (for light, fan, socket or power etc complete) including fixture and fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed..
Supply & fixing point wiring for one light point/ fan point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into PVC conduit (not less than 20mm outer dia) with all fittings and accessories including sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth, etc and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge)
All as per item No.98 herein before but one 3 pin socket outlet 5 Amps independent.
All as per item No. 98 above but with 2.5 Sq mm two single core and 2.5 Sq mm one single core as earth wire for 5/15 Amps socket.
Suppy & Fixing switch piano flush type single pole, one way 6 Amp complete all as specified and directed.
Suppy & Fixing switch piano flush type single pole, one way 16 Amp complete all as specified and directed.
Supply & Fixing lamp holder (modular type) PVC insulated body with back plate for angle/battern fitting complete all as specified and directed.
Suppy & Fixing switch flame proof rotary type with termination box in LM6, 16A, Single pole 250V complete all as specified and directed.
S&F ceiling rose, 3 phase/ PVC polycorbonate/surface bakelite 3 terminal isolated body with base plate complete all as specified and directed.
Supply & Fixing socket outlet 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and directed.
Supply & Fixing socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed.
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp, average life of street light not less than 50000 hours, inluding clamps, nut, bolts, bracket made of flate iron strip 25x4 mm bent to shape for LED fitting for fixing on channel/steel surface complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling, life of tube light not less than 50,000 hours including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Material and labour for Sub main wiring with 2 run of 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/terminal boxes, all fittings and accessories fixed concealed with and including 2.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified and directed. Note :1 The cost of earth wire is included in the quoted rates. 2. Three run of 2.5 sqmm and one run of PVC conduit will be measured as one unit i.e one running metre”
Material and labour for Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/terminal boxes, all fittings and accessories fixed concealed with and including 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified. Note :1 The cost of earth wire is included in the quoted rates. 2. Three run of 4 sqmm and one run of PVC conduit will be measured as one unit ie one running metre”
Supply & Fixing sheet metal enclosure for DBs(double door type) single pole and neutral 8 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed including taking down unserviceable main switches MCB DB’s of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed.
Supply & Fixing sheet metal enclosure for DBs (double door type) Triple Pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 415 volts fixed complete all as specified and directed .
Supply & Fixing 415V, 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP and 40 to 100 Amp current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed .
Supply & Fixing 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed .
Supply & Fixing 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole neutral (SPN) and current carrying capacity 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed .
M&L in replacement of 200 Amps 36 KA MCCB 4 pole 415 V adjustable with breaking capacity of 36 KA of following sizes :- Note :- MCCB 4 pole / MCB TPN required as per sample provided by MES office.
All as per item No. 117 herein before but 250 Amps 36 KA
All as per item No. 117 herein before but 100 Amps 35 KA
All as per item No. 117 herein before but MCB TPN 63 Amps 16 KA
All as per item No. 117 herein before but MCB TPN 40 Amps 16 KA
All as per item No. 117 herein before but MCB TPN 32 Amps 16 KA
Taking down unserviceable flame proof light and supply and fixing Glaze pro CIMFR certified LED flameproof wellglass in die cast AI housing with heat resistance toughened glass. Recommended for Gas/Vapour, IP-65 Protected with including hanging arrangement as per site requirement all as specified and directed by Engr-in-Charge. Make-CROMPTON, Model-FWL1315-30CDL or euivalent approved make as specified in particular spcification.
Taking down carefully of existing 400 watt Hi-bay light fitting and supply, fixing and testing of 200 watt rugged radial LED hi-bay light for varied industrial applications hangging on top complete. Make:- Havells cat pat No BAYBRITESAUCERHBP200WLED757WBTOLTG or equivalent cat pat in make Wippro/ Phillips/Bajaj/C&S Note:- (i) The work to be carried at an hight of 14 to 16 meter and no extra payment shall be paid on this account. The rate quoted shall be deemed to be included this factor. Contractor will be responsible for any type of accident while carrying out the work by labours and all safety measures shall be carried out by the contractor during exection of work. (ii) Contractor shall submit 2 year warrenty of material from manufracturer alongwith purchase voucher.
Supply & Fixing for Crash Bay Bell Alarm wiring PVC insulated unsheathed 2 core 1.5 sqmm copper cable for working voltage 1100 volt cable drawn from ATC to Fire Brigade vehicle stand and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed
Supply and fixing Beacon Light lamp rotating type (Manairco Model AB-1000F) with motor fabricated box, two failsafe beacons with automatic lamp switching, power requirement 117V AC, 60 Hz, 2250Watt, 19.2 Amps installed at ATC bldg top etc complete all as specified and directed. Comprising of the following works :- (a) Repalcement of beacon light lamp (manairco Model AB-1000F) 4 sealed beam 500W PAR 64 and beam width 5 degree wide x 30 degree high and rated lamp life 4000 hours. - (04 Nos) (b) Repair/Replacement of rotating gear motor 220V AC, 50 Hz, 36 flashes per minute,12 rpm. (01 Nos) Note:- Testing/commissioning of lights after replacing making the lights operational shall be deemed to be included in the quoted rate and no extra payment shall be paid for the same.
M&L for repairing/replacement of burnt and damaged part of sliding doors of hanger consisting of following works :- (a) Repair and overhauling of elect motor 3.5 HP capacity installed for moving of gates of hanger - 03 Nos (b) Dismantling of 3.5 HP elect motor 3 phase, 440 volts from hanger door and taking away local works shop and transporting back the same after repairs to its original position complete. (c) Opening of motor winding, cutting of burnt coils and cleaning of slots and replacing the old burnt coils complete all as specified and directed. (d) Applying one coat of red oxide primer, fixing of packing with Pnumax paper and green sheet of glass cloth, rewinding with suitable gauge of super enamelled insulated wire incl condenser. (e) Varnishing with doctor bake varnish, during backtrol and heating properly. (f) Replacement of unserviceable chain, chain gear and greasing to brgs complete. (g) M&L for repair of starter panel box including replacement of burnt contactor, ICs, fuses, ON/OFF siwtch (NO/NC switches), Relay etc and checking of electrical connection throughly and making the door in operational condition for the entire satisfaction of GE/Engr-in-Charge. Notes :- (i) The rate quoted by contractor shall deemed to be included replacement/repaire including all necessary fittings and fixtures required at the site of work. Nothing extra shall be paid on this account complete all as spicified and directed. (ii) Standby electric motor of 3.5 HP shall be provided by the contractor at the site for operation of hanger doors.
Material & Labour for servicing of silent DG set capacity 250 KVA (Three phase diesel engine driven Generator set) complete all as specified and directed. Comprising of the following works :- (a) Overhauling of Self starter assy including required defective part. (b) Replacement of engine oil filters -02 Nos (c) Replacement of diesel filters - 02 Nos (d) Replacement of Air filter - 01 Nos. (e) Replacement of engine oil of required cap with specified grade - 25 Ltr (Approx) (f) Replacement of alternator carbon bushes. (g) Fan belt as per sample - 03 Nos (h) Replacement of alternator bearing of required size - 02 Nos (j) Replacement slipering assy - 01 Nos (k) Replacement of coolant of required cap. (i) Replacement of Battery 12 V, 180 Ah - 02 Nos (m) Replacement of proximate coolant sensor complete with wiring connection. (n) Replacement of LOP (Low oil pressure) indicator sensor - 01 Nos (o) Replacement of door lock - 04 Nos (p) Replacement of fuel tank cap with lock - 01 Nos (q) Replacement of unserviceable ARB card - 01 Nos
M & L for repair of true online UPS system 10 KVA, input 400 V AC range 320-480V AC frequence 50 to 47.5 Hz including replacement of burnt/defective part of the system and making the system in operational condition, consisting with following works :- (a) Checking of operational mode of system (Normal, Battery, Bypass, Manual Bypass, ECO mode, Auto restart mode etc.). (b) Checking of electrical connection throughly . (c) Replacement of rectifier, bypass indicator, diode, capacitor, ICs, and inverter, load/unload indicator etc and other electronics component required on site. (d) Replacement in repair bettary of capacity 12V, 26 Ah - 30 Nos (d) Repairing of deffective/burnt/unserviceable part of rectifier and invertor and making the system in operational condition complete all as specifiec and directed.
Supply and fixing, replacement of unserviceable 100 watt incandescent lamp with glassdoor shed screwed type suitable for H type standing indigator complete all as specified and directed.
M&L for replacement of unserviceable old transformer with 200 watt, 6.6A/6.6A, 5000V, 50 Hz series isolating transformers , suitable for individual lamp control and monitoring saystem and confirming to FAA specification as required. complete all as specified and directed.
M&L for replacement of unserviceable old transformer with 45 watt, 6.6A/20A, 5000V, 50 Hz series isolating transformers, suitable for individual lamp control and monitoring saystem and confirming to FAA specification as required. complete all as specified and directed.
M&L for replacement of unserviceable old halogen lamp with 200 W, 6.6 A halogen lamp suitable for elevated type uni/semi directional high intensity approach light/PAPI fitting .
M&L for replacement of unserviceable old halogen lamp with 45 W, 6.6 A halogen lamp suitable for elevated omni directional type medium intensity approach light fitting.
Supply and fixing industrial plug and socket 63 Amp 3P+N+E with DIN rail, IP-67 complete with one triple pole MCB 415V 63 amps complete all as specified and directed
Supply and fixing industrial plug and socket 32 Amp 3P+N+E with DIN rail, IP-67 complete with one triple pole MCB 415V 32 amps complete all as specified and directed
Taking down of existing unserviceable Aviation obstruction light fitting and supply, fixing and testing of two sided 48 watt LED Aviation obstruction light red, round body complete fittings including 2.5 sqmm wiring and controlling with suitable rating MCB as specified and directed Note:- (i) The work to be carried at outside top of hanger, so contractor shall provide ladder to do this work and no extra payment shall be paid on this account. The quoted rate shall be deemed to be included the same. The contractor will be responsible for any type of accident while carrying out the work by labours and all safety measures shall be carried out during execution of work by the contractor at his own cost.
Supply and fixing Bus bar chamers 100 Amps 4 Way wall mounted for suitable for incoming and out going Cable complete nut and bolts including lugs& cable glans complete as specified and directed
Supply , laying , connecting, testing and commissioning of 25 Sqmm 4 core earthed system under ground LT XLPE insulated screened, PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts laid in trenches, fixed to walls/ drawn through pipe with suitable size glands, crimping type lugs and incl the disturbence surface of road making good with using PCC etc all as specified of the following sizes. Complete as specified and directed. Note;-(Excavation, earthwork sand cushioning and cable protection shall be measured and paid for separately.)
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note : Punned down thickness of sand shall be considered for measurement and payment.
Supply and laying unreinforced precost concrete cable cover class LV, type I, flat of size 250x150x40mm. Complete as specified and directed
Supply & Fixing Modular Bell push, flush type , 6 Amp, 1 module complete all as specified and directed.
Supply and fixing bell electric Alarm type, AC, 230 volts, 50 Hz, single pole complete all as specified and directed.
M/S Rajeev Sharma and Co.
rehman construction company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .