Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.8 L+₹8,603.76 (0.42%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹21.4 L+₹77,293.46 (3.74%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹22.4 L+₹1.7 L (8.22%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹25.4 L
EMD Value
₹50,000
Closing Date
7 Aug 2024, 3:30 pmClosed
Executive Engineer
O/o Executive Engineer, PH Division South, Tvpm
Deposit work of Thiruvananthapuram corporation Laying new PVC lines at various places under Thirumala section Pipe line replacement and extension works at pangode Kachani Thirumala Punnaykamugal Valiyavila Pipeline Work
2024_KWA_682998_1
WRD/KWA-CE(SR)/TR/7352/2024
Open Tender
Civil Works - Water Works
Item Rate
180 days
PH Division, South, TVPM
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,760
₹50,000
Yes
25 Sept 2024
30 Jul 2024
9 Aug 2024
30 Jul 2024
7 Aug 2024
30 Jul 2024
Amount
Pipe Laying
15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
2.7.2:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (requiring blasting)
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
100.98.457:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
100.98.1008:Engaging Coolie.
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
100.9.4:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 40 mm nominal outside diameter pipes.
100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
100.9.7:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
OD3664/2024-2025:Conveying and fixing 25mm/40mm air valves to be put in PVC distribution line as per the direction of the departmental officers
OD3665/2024-2025:Providing new/ alteartion of house connection from the existing main including earth work excavation supplying and fitting suitable saddle piece, supplying and fitting 20mm brass ferrule 1no, 20mm GM full way valve 1no, union 1no and connecting the newly laid main, testing the joints etc. complete but excluding cost of pipe.
OD3681/2024-2025:Interconnection with newly laid line with existing line with PVC/CI/DI Tee (12.5kg/cm2) and reducer CID/CIR joints (3 Nos) suitable to the newly line including cutting the existing line without damages to the line, bailing out water, traffic controlling cleaning and grinding the edges ready for joint including all labour charges cost of materials as per the direction of departmental officers
OD3687/2024-2025:Taking connection from the existing main (single boring), including earthwork excavation supplying and fitting 25mm saddle piece 1 nos,25mm brass ferrule 1 nos, 25mm GM full way valve wheel valve 1 nos, bend 1nos, union 1nos, 32mm pvc adapter 1 nos,110x32 pvc reducer 1nos etc. and connecting the newly laid main,testing the joints etc. complete
OD4128/2024-2025:Taking connection from the existing main (double boring), including earth work excavation ,boring the main, supplying and fitting saddle piece 2 nos,25mm brass ferrule 2 nos, 25mm GM full way valve wheel valve 2 nos, bend 2nos, union 2nos, 32mm pvc adapter 2 nos,110x32 pvc reducer 2nos and connecting the newly laid main testing the joint etc. complete. Rate as per item No 100.1.1 of SH KWA approved data
Construction of Valve chamber
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Supply of Materials
100.98.219:Supply of PVC Pipe, 8kg/cm2, 40mm Dia.
100.98.221:Supply of PVC Pipe, 8kg/cm2, 63mm Dia.
100.98.222:Supply of PVC Pipe, 8kg/cm2, 75mm Dia.
100.98.223:Supply of PVC Pipe, 8kg/cm2, 90mm Dia.
100.98.224:Supply of PVC Pipe, 8kg/cm2, 110mm Dia.
OD4138/2024-2025:Supplying and Fixing PVC Reducer 160x110/110x75/110x63 mm as per site condition
OD4139/2024-2025:110 mm/8 kg end cap
OD4140/2024-2025:90 mm/8 kg end cap
OD4141/2024-2025:75mm/8 kg end cap
OD4142/2024-2025:63 mm/8 kg end cap
OD4143/2024-2025:40 mm/8 kg end cap
OD4144/2024-2025:110 mm/8kg PVC bend
OD4145/2024-2025:90 mm/8kg PVC bend
OD4146/2024-2025:75 mm/8kg PVC bend
OD4147/2024-2025:63 mm/8kg PVC bend
OD4148/2024-2025:40 mm/8kg PVC bend
OD4149/2024-2025:Supplying and conveying of heavy duty CI MH cover
OD4150/2024-2025:Supplying 20mm ASTM Pipe
OD4442/2024-2025:Supply of 50 mm ASTM pipe
Road Restoration of PWD Roads
3.6:Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000m
4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method
4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.
5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
5.4.2b:Dense Graded Bituminous Macadam : - For grading - II (26.5 mm nominal size) Providing and laying dense graded bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with a bituminous binder (VG 30) @ 4.0 to 4.5 percent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level, and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.
5.6.2.a:Providing and laying bituminous concrete with 80-100 TPH hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with a bituminous binder( NRMB) @ 5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level, and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects For Grading - II (13.2 mm Nominal Size)
8.35:Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-
3.17:Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2.
S SANIL KUMAR
Sunilkumar
Alan Joshy J S
Bidder Name
Sunilkumar
VINAYADHANAN D S
S SANIL KUMAR
Alan Joshy J S
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1062613.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .