| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹33.1 L+₹5.3 L (19.0%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹40.6 L+₹12.9 L (46.3%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹44.3 L+₹16.5 L (59.3%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Feb 2020, 6:00 pmClosed
GE DEHU ROAD, PUNE
GE DEHU ROAD, PUNE
REPAIR RENEWAL OF LT DISTRIBUTION AND EARTHING OF MD AND OTM ACCN OF EAST AREA UNDER GE DEHU ROAD
2020_MES_313948_1
8406
Open Tender
Civil Works
Item Rate
270 days
GE DEHU ROAD, PUNE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE DEHU ROAD, PUNE
₹80,000
22 May 2020
11 Jan 2020
12 Feb 2020
11 Jan 2020
5 Feb 2020
22 Jan 2020
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all as specified and directed :-
(a) Soft / loose soil
(b) Hard / dense soil
Excavation in trenches n. exc 1.5m wide, exc 1.5m and n. exc 3.0m in depth and getting out in soft / loose soil complete all as specified and directed by Engr-in-charge.
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge.
Taking out LT Cable of any size any dia including HDPE DWC pipe any dia all as directed. Note:- Excavation will be measured & paid separately.
Relaying of LT Cable of any size obtained from item no 5 as per site requirment and making connections as specified and directed by Eng in charge.
supply & Laying in repair cable XLPE insulated screened PVC bedded ,galvanized steel strip or wire armoured ,electric power cable heavy duty 1100 volts grade with stranded aluminum conducter of following sizes:- Make :- Havells/ Polycab/ Gloster
(a) 70 Sq mm x 3.5 core
(b) 50 Sq mm x 3.5 core
(b) 35 Sq mm x 3.5 core
( c) 25 Sqmm x 3.5 Core
(d) 16 Sqmm x 4 Core
(e) 10 Sqmm x 4 Core
(f) 16 Sqmm x 2 Core
(g) 10 Sqmm x 2 Core
(h) 95 sq mm x 3.5 core
M & L in repair HDPE DWC pipe ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection of the following outer dia :-
50 mm dia
80 mm dia
M& L for GI tubing 50 mm dia light grade for cable protection
M& L for GI tubing 80 mm dia light grade for cable protection
M& L for GI tubing 100 mm dia light grade for cable protection
Restringing OH line of ACSR conductors of any description which includes replacement 22 SWG aluminium binding wire,removing jumper connections, reconnection of binding wire & jumper connections after restringing complete upto the satisfaction of Engr-in-Charge. NOTE :- Each conductor span shall be measured & paid as one RM length.
S&F in repairs ACSR conductor and strengthening on insulators including aluminium binding wire including reconnecting service connections any type which has been disconnected while dismantling old conductor complete all as specified and directed including dismantling of U/S conductor any type any size.
Dismantling and taking down insulators of any size from dismantled/existing LT poles of any type or description complete all as specified and directed.
M & L for LT insulator, PIN type 1100 volts as per IS 1445, grade of size 100mm height, 65mm dia, porcelain, vitreous, white or brown including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down existing unserviceable insulator all as directed. Make;- Elpro or equivalent.
M & L for shackle type insulator as per IS 1445 working pressure in 1100 volts, 100mm height, 115mm dia porcelain, vitreous, white or brown insulator including galvanised mild steel straps of size 31x5mm, washers, insulator bolts of size 14mm dia, washers and nuts, including taking down of u/s shackle insulators complete all as directed by Engr-in-charge.
Dismantling and taking down MS cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section from dismantled/existing LT poles of any type or description complete all as specified and directed.
M&L cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section (MS channel, angle sections, flat, round or square bars ) for reqd sizes and shape including bolts nuts & washers welding bending cutting cold or hot drilling holes for inserting in any shape or size as indicated or directed complete incl painting ( one red oxide primer coat two coats of aluminium paint ) complete.
S & F Cradles hexagonal or rectangular fabricated with galvanised steel wires 4 mm or 3.15 mm dia for road crossings, HT and LT conductors etc., including dismantling existing U/S cradles all as directed.
S&F in repairs synthetic line separators of LT OH lines with nut,bolts & washers straight type horizontal configuration fixed at a point as directed and suitable for single phase 2 wire LT lines
S&F in repairs synthetic line separators of LT OH lines with nut,bolts & washers straight type horizontal configuration fixed at a point as directed and suitable for three phase 4 wire LT lines
M&L for preparing old painted steel surfaces by scrubbing with wire brush and applying two coats of aluminium paint to 9 /11 mtr long LT steel tubular poles complete with connected fittings such as brackets, cross arms, metal portion etc and stick computer cut sticker radium number on the pole with of suitable high letters on 10 cm x 10 cm square block with black enamelled paint complete all as directed by Engineer-in-Charge
Supply & erect in repair in position steel tubular pole swagged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 31 , 09 mtrs long incl painting with two coats of aluminium paint over a coat of red oxide paint all as directed including removing existing pole. ( Note :- Excavation and earth work and PCC in foundation shall be measured and paid separately) Make : Electrosteel/ Indian Pole/ Singh Profiles/ Kalki tubes & Poles
S&F in replacement of old damaged unserviceable battery with box with new battery 12 v 75 AH 3 yrs waranty for solar lights with pole mounting arrangments. Make Exide/Amron/ Luminious
M&L for provision of PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M & L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.
M & L in repairs for earthing with galvanised steel earth plate electrode 60cmx60cmx6.3mm burried directly in ground earth pit not less than 2.25 m deep below normal ground level with top edge of the plate vertically to depth of not less than 1.2m below ground level connected to and including GI strip of size 25 x 4 mm as earthing lead welded with earth electrode (excluding GI protection pipe) and connecting to equipments by means of earthing lead connecting to equipments by means of GI bolts & nuts etc. with provision of char-coal and salt etc. all as per electrical plate No. 3 of SSR Part I, 2009 including RCC cover and MS angle iron frame watering arrangement with GI pipe 20mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc complete all as specified and directed by Engr-in-Charge. Note: Rate quoted deemed to be including excavation by compressor M/C for Soft disintegrated rock to required depth.
Supply and fix in repair earth strip of size 25 x 3 mm galvanised iron strip fixed to wall/over head reservoir on batten or recess or chases or buried inground or drawn in conduit /pipe fixed on poles insulated as per Engr-in-Charge.
Painting Steel surface of any description over 10cm in width using aluminium paint of two coat.
Cutting & trimming of tree trunks/ branches having grith not more than 50 mm, falling on or likely to fall on LT over head electrical line for clearence of 3.0 meter on ground from the nearest conductor/pole /earth etc .& disposal of unservicable materials to distance not exc.50 mtrs .& clearing of site all as directed by Engr -in-Charge. Note:- The distance between two poles is measured as one span.
Supply & fix in repair MCCB of any capacity,4 pole ,415 V,Adjustable type with breaking capacity:-
Supply & fix in repair MCCB 200 Amp, 4 pole, 415 V,with breaking capacity 36 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard/HPL
Supply & fix in repair MCCB 160 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard/HPL
Supply & fix in repair MCCB 125 Amp, 4pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard/HPL
Supply & fix in repair MCCB 100 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,Ics=100% Icu. Make : L&T /LEGREND/ ABB/Sncheider/Standard/HPL
M & L for Danger Notice plate 1.6 mm thick mild steel sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour, Write 'LT SUPPLY 440 Volts 'and fixed with MS clamps bolts and nuts of approved size for LT 15x10 cms Compalete
Supply instal inrepair testing & commissioning of CPRI approved factory make LT panel board outdoor type pedelstal mounted dust proof, weather proof, vermin proof front side double door hinge type with locking arrangement rear side single door hinge type with locking arangement, sheet steel cubical type with slanting roof made out of 3.15mm thick CRCA sheet with powder coated finished suitable length and size. High conductivity 3 phase and neutral copper bus bar of 400 Amps capacity duly mounted on pre cast insulators including earth work excavation, PCC foundation necessary coping work, nuts and bolts and connecting electrically with suitable copper cable lug, cable glands etc complete all as specified and directed to accomodate the following items(near Cinema hall) Incoming:- (a) MCCB , 4 pole 400 Amps 50KA- 01 no (b) Advanced Multi functional meter 4420 series LCD meter C1 with RS481 MAKE :- CAT No WC442011OOOO of L&/Seimens/Schiender (d) LED type indication lamp for RYB- 01 set Outgoing: (a) MCCB 250 amps 4 pole 25 KA - 03Nos. (b) MCCB 100 amps 4 pole 25 KA - 04 Nos (c) LED type indication lamp for RYB.- 03 sets
Supply & fix in repair switch disconnector fuse with encloser to be fixed on wall( suitable for din fuses) 3 pole & neutral with HRC fuse 320/315 Amps capacity, 415 V,Make : FS315A-TPN DIN/BS E of HPL /Indo asian/standard/Havells or equivalent
Supply & fix in repair switch disconnector fuse with encloser to be fixed on wall ( suitable for din fuses) 3 pole & neutral with HRC fuse 200Amps capacity, 415 V,Make : FS200-TPN DIN/BS E of HPL /Indo asian/standard/Havells or equivalent
Supply & fix in repair switch disconnector fuse with encloser to be fixed on wall( suitable for din fuses) 3 pole & neutral with HRC fuse 100Amps capacity, 415 V,Make : FS100A-TPN DIN/BS E of HPL / Indo asian/standard/Havells or equivalent
Supply & fix cable jointing kit for 1100V XLPE grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable complete all as specified and directed by Engineer-in-Charge. Make :- M-Seal/ Densons/ Dowells
10 to 16 sqmm,3.5/4 core
25 to 50 sqmm,3.5/4 core
70 to 150 sqmm,3.5/4 core
Supply and fix in repair FRP junction box for controlling the street / security lights, with four aluminium busbar strips 20x3 mm capacity with epoxy insulation fixed on PVC saddles with nut and bolts, cover with color coded caps with and including MCB SP 2.5 Amps capacity complete all as directed Make- Sintex/ Nationall/L&T
M&L for road cutting and making good with PCC 1:3:6 type C2 (using 20 mm graded stone complete all as directed by Engineer in Charge.
M&L for PVC FRLS round sheathed 6.0 sqmm flexible three core multistranded copper conductor cable for panel 1100 volt , confirming to IS 694 complete allas specified
M/S VR Construction Services
metro electrical services
Mahindra Electric Stores
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .