Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC PALLIYADIYIL VEEDU MUTHUPILAKKADU WEST PO SASTHAMCOTTA 690520 | SASTHAMCOTTA | KOLLAM | KERALA | 690520 | L1 | Accepted-AOC L1 | |
| 2 | L2₹11.8 L+₹54,485.61 (4.84%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹11.6 L
EMD Value
₹29,036
Closing Date
18 Oct 2023, 5:00 pmClosed
Executive Engineer
Water Supply Division Office KWA Attingal
DEPOSIT Replacement PMGSY 2021 2022 Package No. KR 12_106 Kilimanoor Block Replacement of existing existing pipe line in connection with road widening work along Pulluthottam padla mullasserikunnu road in Karavaram Panchayath
2023_KWA_605129_1
WRD/KWA-CE(SR)/TR/9947/2022
Open Tender
Civil Works - Water Works
Item Wise
150 days
Karavaram Panchayath
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,760
₹29,036
16 Nov 2023
20 Sept 2023
20 Oct 2023
20 Sept 2023
18 Oct 2023
20 Sept 2023
20 Sept 2023 - 18 Oct 2023
Amount
Working charges
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
OD106264/2022-2023:Interconnection work in existing pipe line with newly laid PVC pipe using CIR jointr, bend and specials as per direction of engineer in charge.
100.60.19.3:Replacing the chocked / damaged 20mm (3/4 inch) house connection with 15mm meter from existing mains, up to a length of 5m using 25mm ( 3/4 inch ) PE Pipe, PE80, PN16, Conforming to IS 4984: 2016 or later edition and PP PN 16 Compression / GM / Brass specials viz. brass ferrule, brass hexagonal nipple, GM full way wheel valve, bend, MTA, FTA, couplers etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges but excluding cost of water meter and meter box and excluding charges for cutting the concrete / tarred / bituminous roads and as per the directions of the department officers.
100.14.3:Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials: 200mm diameter Ductile Iron Class K-9 Pipes.
18.83.5:Labour for cutting C.I. pipe with steel saw.200 mm diameter C.I. pipe
18.68.1:Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 :Upt 600 mm dia
18.70.3:Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes
18.69.1:Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :Upto 600 mm dia
100.35.3:Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATA
Cost of Materials
100.98.223:Supply of PVC Pipe, 8kg/cm2, 90mm Dia.
100.98.117:Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia.
valve chamber rising
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.4:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
13.1.2:12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
JISHNU J P
Bidder Name
JAYAKUMAR
JISHNU J P
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_901765.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .