Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC VELLAPLACKAL HOUSE VARANDARAPPILLY PO THRISSUR 680303 | THRISSUR | THRISSUR | KERALA | 680303 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.2 L+₹30,000 (7.71%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹3.9 L
EMD Value
₹9,726
Closing Date
4 Mar 2024, 6:00 pmClosed
EXECUTIVE ENGINEER LSGD DIVISION THRISSUR
EXECUTIVE ENGINEER LSGD DIVISION THRISSUR DISTRICT PANCHAYATH THRISSUR
15931 Annual Plan-DPT-2023-24-IJK BP,Karalam GP-Thekkumury lift irrigation - electrification- Karalam GP-Protection work for Venjalakulam-Providing motor pump set- General Electrical Work
2024_LSGD_663658_44
TN-9/2023-24
Open Tender
Electrical Works
Item Rate
365 days
AYYANTHOLE
Please refer Tender documents.
8 documents required · 8 mandatory
₹860
Yes
₹9,726
Yes
2 Jul 2024
26 Feb 2024
6 Mar 2024
26 Feb 2024
4 Mar 2024
26 Feb 2024
Amount
Electrical work
OD407351/2023-2024:Supply of 3 phase 20 H P hp, 15 KW, Vertical open well submersible motor pumpset capable to discharge 2000 LPM of clear water to a head of 20 mtrs, (Head range -10-30)suitable to work with 415V, 50Hz, AC supply. (Deccan -Karvel 20KAM/ Texmo/Kirlosker)
OD407352/2023-2024: Supply of Submersible pump controller with ammeter, volt meter, SSP for 3 phase 20 HP (relay range 20-33 submersible motor pump set. ( L&T MU-G30 FASD suitable for 20 HP ).
90.17.8.8:Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm
90.17.12.6:Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :150mm dia
90.17.14.7:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia
OD407353/2023-2024:Supply and providing 16 mm size nylon marine rope (garwar/equivlent mkae) for hanging the pump set in well, tying with an out side object as required.
OD407354/2023-2024:Charges for the installation of above 20 hp 3 phase submersible pump set into the well after connecting the delivery pipes, with accessories and lead cables to motor and hanging the unit with nylon rope to 9 mtrs depth complete in trouble free operation and conducting trial run satisfactorly.
90.17.7.7:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.6.4.62:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.16.00 sq.mm 3 Run
90.6.4.63:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.16.00 sq.mm 4 Run
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD407798/2023-2024:Supply and providing 8.mm thick MS checqured plate in the existing frame owrk etc asrequired.
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
OD407355/2023-2024:Supply and fabrication conveyance and installation of base frame of panel board using 150 x 75 mm rolled steel channel (ISMC)
90.14.2.2:Supply and providing 3mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
2.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
OD407450/2023-2024:Supplying and fixing 100A HRC fuse base with link on the existing box and giving connection etc as required.
OD407451/2023-2024:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
OD407452/2023-2024:Supply and providing 2.mm thick 3.3KV synthetic elesromeric fire retardent insulating sheet in front of main board etc asrequired.
OD407453/2023-2024:Supply and providing junction box -Sintex make GS JB 2525/equivlent on surface/recess and making good the damages ,colour washing etc as required .
OD407356/2023-2024: supply and providing dry run protection relay curren based in the existing starter and giving conection etc as required (L&T make i-AD
90.6.6.6:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.16 sq mm
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
OD407357/2023-2024:od158324/2021_2022 : Supply and providing surge protection devise conforming to IEC61643 with type 2,limp 12.5KA,Imax50KA 3P+N (4 pole) and fixing the same in the existing enclosure with DIN and giving connection as required
OD407358/2023-2024:Supply and providing 0.5A to 2A SP MCB in the existing panel and giving connections as required
OD407359/2023-2024:Supply and fixing LED indicator, Blue colour, AC/CD 22.5mm cut out dia in the existing panel board and giving connection complete
OD407360/2023-2024:Supply and fixing LED indicator, red, green, black, yellow, orange colour, AC/CD 22.5mm cut out dia in the existing panel board and giving connection complete
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD407361/2023-2024:Supply and providing Test joint for earthing made up of 2 nos, 25x5 mm GI strip, 25 cm long placed on either sides of earth leads and watering pipe, bending, drilling and tightening with 4 sets of brass/SS nut, bolt, washer etc as required.
90.16.4.3:Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 6 mm GI strip
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD407362/2023-2024:Supply and providing 25X3 mm brass bolt and nut with washers on the existing MS box/earth bus etc as required including drilling necessary holes as required.
OD407363/2023-2024:Supply and providing 25X6 mm brass bolt and nut with washers on the existing MS box/earth bus etc as required including drilling necessary holes as required.
OD407364/2023-2024:Supply and providing dust and vermin proof, wall mounting, Hot press moulded SMC Meter Box of following sizes suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit, with 700x450x200 mm or nearest size. (Sintex GS-MB 7450 or equivalent make).
OD407365/2023-2024:Supply and fixing the following accessories in the existing board and giving connections etc. 100A 2 way Neutral link mounted on DMC/ SMC base
14.5:Deduct for not consolidation by ramming and watering while re-filling with sand and or good soil in cable/ pipe laying.
14.4:Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.11:Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD407367/2023-2024:Charges for preparation of application and test report for KSEB connection
SHIJU M.T
Bidder Name
SHIJU M.T
BINSON JOSEPH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1030236.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .