Tender Value
Refer Docs
EMD Value
₹13,100
Closing Date
1 Sept 2021, 11:30 amClosed
EEEANDMWSCN
EEEANDMWSCN NEAR KANHIYA NAGAR METRO STATION DELHI-35
Repair/Renovation of booster pump house along with suction and delivery line at Varunalaya Ph-I and other allied work.
2021_DJB_207620_5
NIT NO. 09 (2021-2022)
Open Tender
Miscellaneous Services
Item Wise
30 days
EEEANDMWSCN
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹13,100
Yes
20 Sept 2021
26 Aug 2021
1 Sept 2021
26 Aug 2021
1 Sept 2021
26 Aug 2021
Dismantling of electric connection from panel and motor, pump and motor from coupling, motor and pump removed from base frame. Removing suction and delivery lines, sluice valves, NRV etc by electric cutter, gas cutter, tools and tackles, manual labour and shifting the same to JE store. Removing the old charging pump from base frame and dismantling the GI line ,PVC tank, valves etc as per site requirement.
S/o monobloc pumpsets rated capacity 5 HP, CI- Impeller, Gland Packing – Sealing, Insulation with inlet and outlet size 80X50mm . Make: Kirloskar/ Crompton /DJB approved
Supply of 80 mm dia. G.I. pipe (medium class) ISI/Jindal/DJB approved make
Supply of 50 mm dia. G.I. pipe (medium class) ISI/Jindal/DJB approved make
Supply of 80mm non rising sluice valve of atleast PN 1.0. Make: Kirloskar/IVC/ DJB approved
Supply of 50 mm non rising sluice valve of atleast PN 1.0. Make: Kirloskar/IVC/ DJB approved
Supply of 50 mm CI NRV of PN 1.0 rating. Make Kirloskar/IVC/ DJB approved make
Providing/Fixing of S.S. pressure gauge having range 0 to 100 psi and 50 mm dia including pipe fittings, bib cock etc. Make: H Guru, Fibeg, DJB approved make
Supply of GI Flange 50 mm dia holes as per site requirement.ISI/Jindal/DJB approved make
Supply of GI Flange 80 mm dia heavy duty holes as per site requirement.ISI/Jindal/DJB approved make
Supply of M.S. Nut bolt & Washer of size as per site requirement .
Supply of Neoprene Rubber sheet.
Installation and fixing of all the above material with required material handling equipments with all safety precautions for installation in the UGR. The job i/c erection the complete pipeline, valve, NRV with hardware goods on each joint, connecting the delivery line of the pump with the existing header line and suction line to the UGR after providing the shutdown. The job includes covering the pipeline with necessary civil work for foundation and covering the pipeline with cement, making electric connections to motors and starters while taking proper safety precautions etc as per site engineer in charge
Supply of MCCB 63 A TPN Make-Make : L&T/ABB/Havells
S/o 5 hp DOL starter in sheet steel encloser with single phase protection feature suitable for 3ph, 415V, AC supply. Make : L&T / Schneider
S/O MCB 63 Amp 4P. Make : L&T/ABB/Havells/Schneider
Supply of 10 sq.mm. 4 core, Aluminium Armoured Cable.Make:-Havells/Anchor/KEI/Polycab
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supply of 50 sq mm cable copper lugs
Supply of 70 sq mm cable copper lugs
Supply of 95 sq mm cable copper lugs
Supply of 120 sq mm cable copper lugs
Supply of 150 sq mm cable copper lugs
Supply of 3 pole, 400 A, 50KA, MCCB with encloser
Assembly charges of all above instruments & spares. Modification of the existing panel at works by providing & fixing of MPU, Phase Changer, Star delta unit with 1.0/1.5sqmm (suitable copper wire) to control the complete panel to operate the existing monobloc pump sets including any minor civil work as per site requirement.
Painting the complete pipeline, motor, pumpsets,nrv, sluice valves etc with two coats of anti- corrosive paint as per directions of engineer in charge.
Testing & commissioning of above system first at NO LOAD & then at ON LOAD and for its proper operating as per the satisfaction of engineer in charge.
Raj Engineering Co.
Super System Engineers
Mehar Enterprises
HYDROCON ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .