Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC VPO TEHSIL JAWALI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.6 Cr+₹13.8 L (9.47%)Rejected-Finance | L2 | Rejected-Finance Lowest bidder |
Tender Value
₹89.7 L
EMD Value
₹1.2 L
Closing Date
7 Sept 2021, 5:55 pmClosed
EXECUTIVE ENGINEER
JS Division Chauntra
Improvement of LWSS Simas , Ootpur and Sandha in Tehsil Lad Bharol Distt. Mandi H.P SH Construction of list water supply scheme from source to main storage tank C o Raw water tank, Sed. Tank, Filter bed, clear water tank, Pump house and Main storage
2021_HPIPH_51840_1
7432-481 dt. 01.09.2021
Open Tender
Civil Works - Water Works
Item Rate
180 days
Lad Bharol
Please refer Tender documents.
8 documents required · 8 mandatory
₹800
EE CHAUNTRA
₹1.2 L
Yes
5 May 2022
1 Sept 2021
8 Sept 2021
1 Sept 2021
7 Sept 2021
1 Sept 2021
Amount
Cutting in earth work and disposal work excavated earth up to all leads and lifts complete in all respect and as per the direction of Enginer-in-Charge
Excavation in foundation and trenches etc. up to all depths and in all classification of earth work such as pick work, jumper work, saturated soil including bailing or pumping out of water, blasting soft or hard rock or chiselling / wedging out of soft/hard rock , where blasting is prohibited, in all lifts including trimming and dressing of sides, levelling of beds to correct grade including shoring, strutting , planking, timbering and dewatering where ever required. Stacking usable and unusable material /soil seperataly , returning the usable soil in 15cm layers by ramming and watering and then dISOsing of all surplus excavated soil/ unusable material as directed within all leads/ lifts complete in all respects within all leads and lifts as per direction of the Engineer-in-charge.
Providing and laying cement concrete 1:4:8 (1cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of from work in foundation and plinth complete in all respect with in all leads and lifts and as per the entire satisfaction of Engineer-in Charge.
Providing and laying cement concrete 1:5:10 (1 cement:5:sand:10 graded stone aggregate 40mm nominal size) with 15% plum and curing complete excluding cost of form work in retaining wall/breast wall, the size of plum shall usually be 150mm to 300mm as per the direction of Engineer-in-Charge..
Providing and laying cement concrete 1:1.5:3 (1cement:1.5 sand : 3graded stone aggregate 20mm nominal size)and curing complete excluding cost of form work and re-inforcement for reinforced concrete work in:-
Foundation , footing basis of columns & the like and mass concrete complete in all respect and as per the direction of Enginer-in-Charge
Wall (any thickness but not less than 0.1 m thickness) attached pillasters, buttresses, plinth and string courses, etc. from top of foundation level upto floor two level complete with in all leads and lifts as per direction of the Engineer-in-Charge.
Suspended floor ,roofs, lendings and shalves and thier suports balconies,beem griders and bressumers and cantiliver upto floor two level complete with in all leads and lifts as per direction of the Engineer-in-Charge.
Providing tor steel reinforcement for R.C.C. work including bending,binding and placing in position complete upto floor two level in all respect complete with in all leads and lifts as per the direction of Engineer-in-Charge.
Providing form work of steel plate 3.15mm thick planking so as to give a rough finish including shuttering, centring, shuttering and propping hight of propping and centring below supporting floor to ceiling not exceeding 4 mtrs and removal of the same for in-situ reinforced concrete and plain concrete work in lintels, beams etc. including all leads and lifts in: and as per the entire satisfaction of Engineer-in Charge.
Foundations, footings, basis of columns & the like and mass concrete.
Vartical surface such as walls (any thickness) portion and the like including attached pillers,buteress plinth and staircases and the like.
Flat surfaces such as soffits of suspended fioors roofs landing and the like . Floors etc up to 200mm in thickness. complete in all respect and as per the entire satisfaction of Engineer-In-Charge.
Beams, cantilivers, girders and lintels sides and soffits of beams,beam haunchings cantilivers, girders, bressumers and lintels not exceeding 1 metre in depth
Edge of slabs & Breaks in floors & walls under 20 cm wide complete in all respect and as per the entire satisfaction of Engineer-In-Charge.
Arches/ Dom Slab.
Sloping of batterings surfaces etc.
Providing and fixing precast SFRC man hole cover and frame confirming to relevant ISS with up to date amendments, 560 mm nominal diameter medium duty with locking arrangements.
Laying , jointing , testing & carrige of galvanized steel tube fittings in trenches of following dia (L) class (Earth work in trenched to be measured and paid or seperately .) Inlet,Outlet and Scour pipe etc complete in all respect with in all leads and lift and as per the direction of Engineer-in-Charge.
80 mm dia
100mm dia.
Providing and fixing C.I. Sluice valve (with hand wheel) as per IS:780 Class-I upto 300 mm dia (including brass spindleand as per IS:2906 class II for diameters more than 300 mm complete with bolts, nuts, rubber insertion etc,(The tail pieces if required shall be measured and paid for separately):
80 mm dia
Providing 200 mm wide cast iron rungs with chequered or ribbed non slip surface including fixing in man hole with 200x200x100 mm cement concrete 1:3:6(1cement:3 sand:6 graded stone aggregate 20mm nominal size)
Providing and placing in horizental layers filtering media duly graded,screened,cleaned and washed as spacified.
Top layer, Fine sand (Eff. Size 0.20 mm ṭo 0.40 and uniformity co-efficient 2.00to 3.00).
Second layer, Coarse sand, 3mm-6mm
Third layer :Bajri 6mm to 20mm.
Fourth layer : Broken stone20mm to25mm.
bottom layer : Broken stone 50mm to75mm.
Providing and placing Ist class standard bricks in filter bed in two layers so as to make cross drains as per direction of Engineer-in-Charge..
Providing and laying cement concrete 1:6:12 (1cement:6 sand:12 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete with in all leads & lifts as per direction of Engineer-in-Charge.
Random rubble masnory/ polygonal rubble masonry (uncoursed/brought to courses) with hard stone of apporved quailty in foundation & plinth including levelling up with cement concrete 1:6:12 (1Cement :6 sand :12greded stone aggregate) in CM 1:6 (1cement : 6sand) complete with in all leads and lifts.
Boulder filling under floor complete with in all leads and lifts.
Brick work using common burnt clay building bricks in super structure above plinth level upto floor two level in cement mortor 1:4 ( 1 cement : 4 sand ) Ist class brick complete with in all leads and lifts.
Providing wood work in frames of door and window 2nd class Deodar wood with in all leads and lift,carrige of material and other incidental charges complete in all respect as per the direction of Enginer-in-charge
Providing and fixing panneled glazed or panneled and glazed shutters for doors, windows and clerestory windows, including black enamelled iron butt hinges with necessary screws 40 mm thick 2nd class deodar wood complete with in all leads & lifts as per direction of Engineer-in-Charge.
Providing & fixing M.S. grills of required pattern in wooden frame of window etc. with M.S. flats, square or round bars with round headed bolts and nuts by screws plain grill complete with in all leads and lifts..
Cement concrete flooring 1:2:4 (1cement : 2sand : 4 graded stone aggregate 20mm nominla size) laid in one layer finished with a floating coat of neat cement 40mm thick complete with in all leads and lifts.
6mm thick cement plaster to ceiling in cement mortar 1:3 (1 cement:3 sand)
15 mm cement plaster in single coat on rough side of brick/ concrete/ stone wall for interior plastering upto floor two level including arrises internal rounded angles, chamfers and or rounded angles not exceeding 80mm in girth and finished even and smooth in cement mortor 1:6 (1cement:6sand) complete with in all leads & lifts as per direction of Engineer-in-Charge.
Flushing pointing on brick work with cement mortor 1:3 (1cement :3sand).
White washing with lime on un-decorated wall surfaces (with two coats) to give an even shade including thoroughty brooming the surface to remove all dirt,dust,mortor dirt and other foreign matter.
Distempering with dry distemper of approved brand and manufacture ( two coats ) and of required shade on undecorated wall surfaces to give an even shade sand papered smooth.
Applying priming on new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil, grease, dust and other foreign matter, sand preparing and knotting. Ready mixed paint brushing wood primer pink.
Painting two coats ( excluding priming coat ) on new wood and wood based surfaces with enamel paint to give even shade including cleaning the surface of dust and other foreign matter, sand preparing and stopping with enamel paint other than white.
Providing and fixing oxidized M.S. sliding dooor bolts with nuts and screws etc. complete 300x16mm complete with in all leads & lifts as per direction of Engineer-in-Charge.
Providing and fixing anodised M.S. Tower bolts (Barrel type) with necessary screws etc.complete .
Providing and fixing Oxidized M S Handle with necessary screws etc complete. 125 mm
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement: 3sand:6graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth.
Providing under layer for plinth protection of 75mm thick (unconsolidated) bed of dry brick /stone aggregate 40mm nominal size) well remmed and consolidated and grouted with fine sand including preparation of ground.
Half brick masonry in common brunt clay building bricks in cement mortor 1:4 ( 1 cement:4 sand ) 2class bricks complete with in all leads and lifts.
Providing and laying cement concrete 1:2:4 (1cement:2 sand:4graded stone aggregate 20mm nominal size ) and curing excluding cost of form work and reinforcement for reinforced concrete work in:-
Suspended floor,roofs, landings,shelves and their supports balconies, beams,girders, bressumers and centilevers upto floor two level complete with in all leads & lifts as per direction of Engineer-in-Charge.
White glazed tiles 6mm thick flooring cement mortar 1:3 (1cement:3 sand) complete with in all leads and lifts.
White glazed tiles 6mm thick in skirting risers of steps and dado 12mm thick cement mortar 1:3 (1cement:3 sand) complete with in all leads and lifts.
Distempering (Two coat) with oil bond wash able distemper of approved brand and manufacture and of required shade on undecorated wall surfaces to give and even shade over and including a priming coat with distepter primer of approved brand and manufacture after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even and sand papered smooth. Priming coat with distemper primer in all leads and lifts.
Providing and fixing automatic flushing cistern with a pair of C.I. or M.S. brackets complete with fittings including Syphonic apparatus, mosquito proof lid, unions and coupling for connections with inlet, outlet and overflow pipes including cutting holes and making food the same (overflow pipe to be measured and paid for separately) Viterous china 5 ltrs. capacity.
Providing and fixing vitreous China wash, down water closet ( European type WC pan) with integral "P" or "S" trap including jointing the trap with soil pipe in cement mortar 1:1(1cement:1 Sand)( Seat and cover to be measured and paid for seperately) Anglo Indian ( Universal Closet) complete in all respect in all leads and lifts and to the entire satisfaction of Engineer-in-charge .
Providing and fixing 100 mm size P or S trap for water closet ( Squatting Pan) including jointing the trap with the pan and soil pipe in cement mortar 1:1 ( 1cement : 1 sand) Sand cast iron
Providing & fixing viterious china wash basin with sinle hole for pillartap with CI or MS bracket painted white including cutting hole inculding good the same excluding fitting cera sanitary work (cornet) white 550x400
Providing & fixing viterious china pedestral for wash basin complete recessed at the basic for reception of pipe and fittings cera sanitary work (carnet) white (Vitrious China in white colour)
Providing and fixing water storage tank Sintex having of capacity of 500 ltrs. with necessary fitting i/c over flow pipe, Scour pipe etc. inlet and outlet and inside paint of approved quality complete including hoisting complete in all respect.
Providing and fixing on wall face PVC (D - Plast) rain water pipes of working pressure not less 4.5 Kg/Sqcm including fitting the joints with approved adhesive complete with in all leads , lifts and carriage of materials.110 mm nominal bore.
Providing & and fixing on wll faces PVC door bend (D-plast) withovalaccess door inserstion rubber washer 3 mm thick bolts and nuts ISI marked complete including fixing wit approved adhesive complete 75 mm nominal bore
Providing and fixing to wall ceiling and floor galvanised mild steel tubes (Medium grade) tube fittings and clamp including making good the wall ceiling and floor in all leads and lifts.) 15 mm nominal bore
Providing and fixing full way wheel valve 15 mm dia Gun metal.
Providing and fixing C. I cowl 100 mm dia .
Providing and fixing brass bib tap (superior qualityor heavy type) 15 mm dia.
Providing & Fixing CP Brass Soap Dish with CP breckets fixed to wodden plugs with CP brass screws complete in all respect in all leads and lifts.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light p
Group -C
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper condu
i)2x1.50 Sq.mm.
ii) 2x2.50 Sq. mm.
(a) Supplying and fixing 3 pin 5/6 amps. Socket outlet on the exists switch box/covers including connections etc. as required.
(b) Supplying and fixing 2 way 5/6 amps. Tumbler/piano type switch on the existing switch box on the switch box/cover including connections etc. as required.
(a) Supplying and fixing 3 pin 15/16 amps. Socket outlet on the exists switch box/covers including connections etc. as required.
(b) Supplying and fixing 15/16 amps. Tumbler/piano type switch on the existing switch box on the switch box/cover including connections etc. as required.
Supplying and fixing wooden box of following size (nominal) on surface or recess with suitable size of phenolic laminated sheet cover of in front as required.
(a) 229 mm.x 102 mm.x 60 mm. deep
(b) 203 mm.x152 mm.x 60 mm. deep
Providing and Supplying CFL 1 x 23 watt of reputed make in all leads and lifts.
Providing and Supplying of CFL 1 x 5 watt in all of reputed make in leads and lifts.
Supplying and Fixing 5 Amps to 32 Amps rating, 240 Volts, L series miniature circuit breaker of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required Cat - A. (Single Pole)
Supplying and fixing ceiling rose on exisiting junction box/wooden block i/c connection etc as required.
Supplying and fixing of following way,single pole and and netural sheet MCB distribution board, 240 volts, surface/recess, complete with tinned copper bus-bar, wire set,netural link,earth bar, din-bar,detachable gland plate, blanking plate, cable ,identification labels interconnection,phosphatized and power painted, including earthing etc.as requaried:-
Single door -16 way
Supplying and fixing following rating, double pole , 240 watts, isolator in the exisiting MCB DP completle with connections (testing and commissioning etc. as required (63 amp. CAT A)
Providing, instalation, testing and commissioning of ceiling fan with regulator,including wiring the down rods of standered length (up to 30cm )with 16/0.20 mm.twin twisted flexible, cotton braided,copper cable,including providing and fixing phenolic,laminated sheet cover on the fan box and earthing etc. as required:-
Ceiling Fan 1400 mm. sweep, category-A
Providing and fixing ultra slim decorative extruded box fixture with demostic electronic ballast, snap-on installers,suitable 28 watt FTL (T5),complete with all accessories (including one No T-5 Tube),connections testing and commissioning etc.as required :-
1x28 watt-FTL (T5) (Category-A)
P/F street light with CFL 65 Watts for pump house and jack well complete in all respect
Providing and fixing two core servise wire 6 sqm thick
Providing and fixing 1.80m high barbed wire fencing with angel iron post 2.50m C.C with 9 horizontal row and 2 diagonal row and barbed wire embendded in C.C 1:4:8.
Providing and fixing of steel gate of size 1.20x1.50m & applying of priming coat of red lead paint. In all angles and MS sheets.
Providing , laying, fixing, jointing and testing in trenches steel pipe of following dia meters confirming to ISO 3183-2007, pipe grade L390 or X-56 (latest with upto date amendments) having wall thickness as specified below with plain end and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, provinding and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & directin of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
125 mm dia ,,Wall thickness 6.60 mm FT-34 (Ist stage)
Laying, jointing and testing of GAS hubs in trenches Galvanised mild steel tubes of following dia meters confirming to BIS 1239-2001 (GI Pipes) (latest with upto date amendments) having wall thickness as per code with plain ends in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 (with latest up to date amendments) duly welded in two layers (two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standards. The laying of pipe will include all operation such as cutting, welding, jointing, providing & fixing of MS flanges, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
125 mm dia GI pipe, Medium grade Flange table 17
Providing , laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of Steel pipes of following dia meters confirming to ISO 3183-2007, pipe grade L290 or X-56 (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
125 mm dia , (ISO 3183-2007), L-290,Wall thickness 6.60 mm
125 mm dia , (ISO 3183-2007), L-290,Wall thickness 4.00 mm
Laying,jointing,testing of GI pipes( by way of circumfrential butt welded joints by electrical arc welding ) and testing of Galvanised mild steel tubes (GI Pipes) of following dia meters confirming to BIS 1239-2001 (latest with upto date amendments) having wall thickness as per code with bevelled / plain ends in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The damaged portion of the pipes and specials made form the parent tube during welding or otherwise shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
125 mm dia , (Medium class) IS- 1239
IST STAGE Supply of submersible raw water pump set of reputed make such as KSB/Calama/SU/joinsion conforming to latest relevant BIS code. The pump should be fitted with free flow impellers of suitable alloys as per BIS 8034-1978 latest suitable for lifting raw water having 6000 PPM turbidity, grease packed bearings and shaft with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specification. The pump shall be directly coupled to submersible squirrel cage electrical induction motor of same make conforming to BIS 9283-1979 (latest with up to date amendments) totally dust and water proof for submersible duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical load with minimum bear and tear. It should also be fitted with a device to take up expention of water with heating of motor. The pump should include water level guard,errection clamps,cable clips and depth gauge etc. and suitable for opration in data given Location of Site Binwa river Beas. Discharge = 8.92 LPS for each pump. Total Head = 38.31 Mtrs Length of column/ Discharge pipe = 60 Mtrs each pump Dia of colmn assembly = 125 mm dia Low Water Level = 590.50 mtrs Submersgence Level =590.00 mtrs.
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens cnonforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling .
Providing & fixing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angale iron post of suitable height and size ISA 40x40x6mm duly paintedcomprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and havingcapacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977with upto date ammendments and of suitaible range with which should have control box, oprating handel and trip/reset bush button on/ off indicators, re-indicating off spring conditionof the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breakeron occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electricalsirens against single phasing,no voltage,high voltage & overloading & phase voltage difference
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ Kartar of reputed make of suitable size cast iron PN-1 double flanged sluice valve having size equal to due step higher than delivery of pump and capable of with standing nominal seat pressure of 10 kg/cm^2
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar of suitable size cast Iron PN-1 double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 10 kg/cm^2
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar of suitable size cast Iron double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main for withstanding nominal seat pressure of 10 kg/cm^2
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICCmake from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost..
P/L suitable size copper PVC insulated armoured power three core cable conformingto BIS 1554(part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICCmake from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments for above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply of standarad make 100mm dia circular dial pressure gauge of suitable range Fiebeg/ Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L column pipe considering site requirements,NPSH required & available & common header having area equal to two times the area of delivery branch of pumpincluding tapers,flanges,rubber gaskets,3mm thick as per BIS-2712-1978 nuts & bolts as per1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge The pipes shall be capable of withstanding 1.5 times thetotal presure indicated in item no. 1e(ii).
(2nd Stage)Supply of horizontal spindle, vertical split casing single/Multistage centrifugal / reciprocating pumps of standarad make such as KSB/Mather & Platt/Jyoti/Kirloskar/WASP /Best & Crompton conforming to BIS latest with upto date ammendments read with BIS 9137-1978 or latest to handle clear water having turbidity 500PPMwith impellers ,casing ring& saft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlosker/ NGEF/Crompton/Siemen/Joti/ABB/Marathan approved by the department .slip ring/ squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below.Location of Site Pump House Near JamthlaVillage Capacity 8.92 lps for each pump. Total head in Mts. 564.32 mts If total head is not known then following details be provided:- i) Static head 531.00 mts Dia of R/Main 125 mm
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standarad make such as MEI/Kilburn/Jyoti/ Siemens cnonforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slipriing motor (make to be specified by the tenderers) mounted on panel board withmagnetic type over load release & dashpot,time lag,under voltage release with initial oil filling Note:- Star delta -starter upto 37.5 KW ,ATS between 37.5 KW to 50 KW and Stater rotor starter with slipring motor.
Providing & fixing M S sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angale iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internalelectric connections. The drawing of panel board shall be subject to approval of Engineer in charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and havingcapacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediatly after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to wirdth of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto date ammendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in comming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 phase indicating lamps complete with toggle switches for individual motors conforming to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit breaker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977with upto date ammendments and of suitaible range with which should have control box, oprating handel and trip/reset bush button on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breakeron occurance of earth fault on/ of breaker load side.
Hour run meter of reputed make of four digit capacity conforming to BIS-722(latest edition)/recommendations.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing,no voltage,high voltage & overloading & phase voltage difference
Change over Switch of reputed make & suitable capacity
Single phase preventor of reputed make & suitable capacity
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/ of reputed make of suitable size cast steel double flanged ASA-300 sluice valve having size one step higer to delivery of pump and capable of with standing nominal seat pressure of 52 kg/cm^2 class ASA-300 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend- -ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure ) 104 Kg/Cm2as per BS 1414(API 600)
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size cast steel ASA-300 double flanged swing check type reflux valve having bye pass arrangement & size one step higher to delivery of pump for withstanding nominal seat pressure of 52 kg/cm^2class ASA-300 NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then thesluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2)as per BS 1414(API 600) .
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader of suitable size Cast Steel ASA-300double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/main ie 65mm diafor withstanding nominal seat pressure of 51 kg/cm^2class ASA-300NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammend--ments.However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 Kg/cm^2) or class 300 ASA (seat pressure 52 Kg/cm^2) or class 600 ASA (seat pressure 104 Kg/Cm2)as per BS 1414(API 600) .
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Kartar of reputed make of suitable size cast iron flanged sluice valve confirming IS 780, size equal to dia of suction pipe ; PN1 providedwith hand wheel/Cast iron Cap.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments Siemen/Gloster/ICCmake from meter of HPSEB to OCB & from OCB to Busbar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories suchas thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor .The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost..
P/L suitable size copper PVC insulated armoured power three core cable conformingto BIS 1554(part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICCmake from switch to starter & starter to motor (one cable for carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipessolder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments BHEL/GEC/Machneil/ Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply of standarad make 100mm dia circular dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conformingto BIS 3624-1987 latest with up to date ammendments
Erection of all items except item no. 84 to 84.02 i/c cost of tees,bends tapes & any others fittings required as per site conditions and as per direction of Engineer-in -Charge.
SANGRAM NAIK
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .