Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹3.1 L
EMD Value
₹15,800
Closing Date
30 Jan 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DEPUTY EXECUTIVE ENGINEER, CAPITAL PROJECT ELECTRICAL SUB DN NO 23, GANDHINAGAR
Checking of Existing Electrical establishment & installing fire penetration system at office of panchayat seva pasandgi mandal, Karmayogibhavan, Gandhinagar [4th attempt]
267805
17/05 OF 2025/2026
Open
Electrical
Works
Gandhinagar
8 documents required · 8 mandatory
₹600
Dy. Executive Engineer, Capital Project Electrical Sub Division No 23, Gandhinagar.
₹15,800
21 Jan 2026
21 Jan 2026
21 Jan 2026
30 Jan 2026
21 Jan 2026
Name of Work Checking of Existing Electrical establishment & installing fire penetration system at office of panchayat seva pasandgi
mandal, Karmayogibhavan, Gandhinagar [4th attempt]
Fund Head : Deposited Work
Sr. No. Item No. Particulars. Qty. Rate Amount
Signature of Contractor Deputy executive Engineer
C.P Electrical R & B Sub Dn
Name of Work: Checking of Existing Electrical establishment & installing fire penetration system at office of panchayat seva pasandgi mandal, Karmayogibhavan, Gandhinagar [4th
Sr. Quantity Description of Item Rate Per Amount
in Figure. in words.
Checking of Existing Electrical establishment & installing fire penetration system
at office of panchayat seva pasandgi mandal, Karmayogibhavan, Gandhinagar Rupees Two
hundred Forty Paise
Carrying out the testing of earth fault and overload relay by authorized person
,on L.T. side. by removing the fault of relay by checking the trip devices, control
2 2 Job. wiring and putting the same in working order with test report 2140.19 Job.
hundred Forty Paise
Per Measurement of earthing resistance by loop test with authorized test report after
Rupees Four hundred Per
Earth isolating & cleaning joint.
3 2 428.24 Twenty Eight Paise Earth
Twenty Four Only Pit
Testing of transformer oil by calibrated instrument for dielectric breakdown
Rupees Four hundred
strength with test report
4 1 Job. 428.24 Twenty Eight Paise Job.
Twenty Four Only
Supply installation, testing and Commissioning of Test clamp to disconnector the
Down conductor from the earth termination network for regular checks of the
Rupees Nine hundred
earth termination resistance value.( including UPVC box and all accessories.)it
5 2 Nos. 999.90 Ninety Nine Paise Ea.
shall meet the requirement of IEC 62561-2.( As per perusal Gujarat Goverment,
R & B deptt,Gandhinagar T.S NO -ELC/1025/C-1, Dt-01/02/2025. Item No-128)
SITC and fixing of ACE mortal seal for fire penetration sealing system in floor
opening with necessary Minor civil work( Removing and reinstaling bison panel (
with replacement of sheet if it breaks during work)with required colour work and
making the surface as same after mortal sealwork) for vertical shaft & wall
opening FM approved class 4990. the mortal seal shall have minimum 2 Hours
fire resistant and minimum thickness 100 mm. it should have been tested
atCBRI roorkee with following test in sequence on same sample without any Rupees Twenty
touchup or modification during the test. with fire rated Foam and PVC Three Thousand
6 12.00 Sq.mtr 23886.50 Sq.mtr
intumescent wrapping systems.Application should be done by authorised Eight hundred Eighty
firestop speciallist by NFPA approved.(1) Impact test 2.5 Kgs hammer,(2) water Six Paise Fifty Only
absorbition test for 24 hours (3)Accelerated ageing for 168 Hours.(4) vibration
test for 4 hours(5) fire resistant test as per standards ASTME 814, UL-1479, IS
12458/2019, BS 476 PART 20( Certificates of all standards are
required),(6)Hose stream test. manufacturer original batch test certificate for
physical properties to be submitted.( As per perusal Gujarat Goverment, R & B
deptt,Gandhinagar T.S NO -ELC/1025/C-1, Dt-01/02/2025. Item No-130)
Sr. Quantity Description of Item Rate Per Amount
in Figure. in words.
Supplying & erecting in earthpit of minimum bore dia. 225mm size approved
make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS
3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia
of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-
250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic
value surrounded by highly conductive compound with high charge dissipation
suitable for following type of applications with chamber and heavy duty cover
(A)(approved make OEM has to submit test certificate including value of earth Rupees Five
resistance of installation duly stamped and signed by agency and officer Thousand Eight
7 2.00 Nos. Incharge has to ensure the value of earthing resistane mentioned in test 5842.85 hundred Forty Two Ea
Certificate) & having back filling compound of (B) Inner chemical (CCM Paise Eighty Five
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Only
Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to retain moisture for long
time Necessary test report must be submitted by Agency.[A] For electrical
installation up to 440 V
Length of Pipe - 1 Mtr
Back filling compound - 1 Nos. of Bag of 15 Kgs.
Providing and erecting Annealed bare Copper wire 8 to 16 SWG. Rupees Seven
hundred Ninety Four
Paise Eighty Seven
Rupees Three Lakh Fourteen thousand One hundred Forty Three Paise Thirty Three Only
I/We am/are willing to carry out the work at(No above rates allowed) ____________% below ___________________________________
__________________percent (Should be written in figures and words) below the tendered rates mentioned above.
Amount of my/our tender works out as under :
Put to Tender Rs. Put to Tender Rs.
(Please strike out whichever is not applicable)
1 I/We hereby declare that I/We have visited the site, fully exquisite myself/ourselves with the local situation regarding materials and other factors pertaining to the work
before submitting this tender.
2 I/we hereby declare that I/We carefully studied the conditions of specifications and other tender documents of this work and agree to execute the same accordingly.
3 A tender with any overwriting in percentage (should both in word and figures) rejected out right.
4 Insertions and/or corrections in the percentage quoted ( both in word and figures) resulting into increase in the value of the work shall be rejected outright unless it is
authenticated by the office opening the tender at the time of opening of tender.
5 Dismentaling the existing material taken by contractor as mention rates.
Signature of Contractor Deputy executive Engineer
C.P Electrical R & B Sub Dn
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
G S T LTR.pdf
GR.pdf
NOTICE NO. 17 2025 2026.pdf
PQ.pdf
SBD Document.pdf
SCH a b and c.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .