Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹6.3 L (5.22%)Admitted-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | ₹1.3 Cr+₹6.3 L (5.22%) | L2 | Admitted-Finance |
| 3 | L3₹1.3 Cr+₹7.8 L (6.41%)Admitted-Finance | ₹1.3 Cr+₹7.8 L (6.41%) | L3 | Admitted-Finance |
| 4 | L4₹1.4 Cr+₹14.1 L (11.6%)Admitted-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹1.4 Cr+₹14.1 L (11.6%) | L4 | Admitted-Finance |
| 5 | L5₹1.4 Cr+₹14.5 L (11.9%)Admitted-Finance DOOR NO 10 38 21 A RAMNAGAR VISAKHAPATNAM 530 002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | ₹1.4 Cr+₹14.5 L (11.9%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Power Dynamics L3 | M/s Saptagiri constructions L5 | P SRINIVASA RAO L1 | Vijaypower Generators Limited L4 | DANDU CONSTRUCTIONS L6 | Roy and Sons Infrastructures L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of U/s DG set 500 KVA capacity and disconnecting all coomections, LT panel board and cables and loading and transporting the the DG set and handing over to the MES storeyard and as directed by the Engineer-in-charge. | 2 | Each Job | 12,500 ₹25,000 Lowest | 99,999 ₹1,99,998 | 54,999 ₹1,09,998 | 15,000 ₹30,000 | 15,000 ₹30,000 | 15,000 ₹30,000 |
| 2.00 | Supply, installation, testing and commissioning of silent Diesel Engine Generating set of 500 KVA capacity all as per CPCB-IV + norms, 415 Volts 3 Phase, 0.8 Power Factor, 50 Hz, 1500 RPM, self excited, self regulated, brushless AC generator with AMF panel of suitable rating including accoustic enclosure suitable for ambient condition at sea area and conforming to Engine as per IS : 10002, ISO-3046, BS-5514 and Alternator as per IS: 4774, BS EN 60034-1 with all necessary accessories for proper functioning of DG set including PCC Foundation, GI Pipe for laying of cable etc all as per manufacturers instructions complete all as specified in Particular specifications and as directed by Engineer-in-charge. | 2 | Each Job | 54,75,000 ₹1,09,50,000 | 59,49,999 ₹1,18,99,998 | 53,55,999 ₹1,07,11,998 Lowest | 56,67,000 ₹1,13,34,000 | 57,00,000 ₹1,14,00,000 | 56,77,500 ₹1,13,55,000 |
| 2.01Note : 1. The capacity of Generator set shall be net after all due de-rating factors as per relevant IS desing and site conditions. 2. Rate quoted shall be deemed to be inclusive of cable and terminations fro DG et to AMF panel, with necessary fixing arrangments all as specified and directed. 3. The rate quoted shall be deemed to include for first fill of oil and final successful acceptance test. | |||||||||
| 3.00 | Supply, laying & testing, replacement LT UG XLPE cable, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) earth system with stranded aluminium conductor, 1100 volts grade of size 3.5 core 630 sqmm and conforming to IS all as specified and directed. | 114 | RM | 3,990 ₹4,54,860 | 2,799 ₹3,19,086 | 2,259 ₹2,57,526 Lowest | 5,280 ₹6,01,920 | 3,650 ₹4,16,100 | 3,815 ₹4,34,910 |
| 4.00 | Supply, laying & testing, replacement LT UG XLPE cable, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) earth system with stranded aluminium conductor, 1100 volts grade of size 3.5 core 400 sqmm and conforming to IS all as specified and directed. | 140 | RM | 2,590 ₹3,62,600 | 2,259 ₹3,16,260 | 1,809 ₹2,53,260 Lowest | 3,060 ₹4,28,400 | 4,000 ₹5,60,000 | 2,190 ₹3,06,600 |
| 5.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying pipe lines, cables etc and nexc 1.5 m in depth and getting out hard / dense soil complete including taking out cables, cable cover all as specified and directed. | 31 | Cum | 740 ₹22,940 | 225 ₹6,975 Lowest | 279 ₹8,649 | 279 ₹8,649 | 1,050 ₹32,550 | 300 ₹9,300 |
| 6.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying pipe lines, cables etc and nexc 1.5 m in depth and getting out soft / loose soil complete including taking out cables, cable cover all as specified and directed. | 29 | Cum | 490 ₹14,210 | 189 ₹5,481 Lowest | 279 ₹8,091 | 279 ₹8,091 | 1,500 ₹43,500 | 280 ₹8,120 |
| 7.00 | Returning, filling-in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm using excavated soil all as specified and directed. | 32 | Cum | 200 ₹6,400 | 72 ₹2,304 | 99 ₹3,168 | 21 ₹672 Lowest | 500 ₹16,000 | 80 ₹2,560 |
| 8.00 | Removing excavated materials to a distance not exceedcing 50 meters and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed. | 27 | Cum | 295 ₹7,965 | 99 ₹2,673 | 189 ₹5,103 | 21 ₹567 Lowest | 500 ₹13,500 | 80 ₹2,160 |
| 9.00 | M&L for Unreinforced Precast Cement Concrete Cable Covers, Class LV Type - 1, Flat, size 250mm X 150mm X 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and directed. | 1,300 | Each | 59 ₹76,700 | 45 ₹58,500 | 72 ₹93,600 | 30 ₹39,000 Lowest | 150 ₹1,95,000 | 40 ₹52,000 |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
24 Jun 2026, 6:00 pmClosed
PK SRIVASTAVA, IDSE, CWE No 2 VISAKHAPATNAM
CWE NO 2 VISAKHAPATNAM, RAILWAY STATION ROAD, VISAKHAPATNAM
SPECIAL REPAIRS / REPLACEMENT OF DG SETS WITH CONTROL PANEL AGAINST BER OF TP AREA AT INS KALINGA UNDER GE (P) (N) KALINGA
2026_MES_766598_1
82781
Open Tender
Civil Works
Item Rate
GE P NAVY KALINGA
SPECIAL REPAIRS / REPLACEMENT OF DG SETS WITH CONTROL PANEL AGAINST BER OF TP AREA AT INS KALINGA UNDER GE (P) (N) KALINGA
7 documents required · 7 mandatory
₹1,000
GE (P) (N) KALINGA
₹2.0 L
Yes
13 Aug 2026
20 May 2026
1 Jul 2026
20 May 2026
24 Jun 2026
10 Jun 2026
20 May 2026 - 17 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of U/s DG set 500 KVA capacity and disconnecting all coomections, LT panel board and cables and loading and transporting the the DG set and handing over to the MES storeyard and as directed by the Engineer-in-charge. | 2 | Each Job | - | - |
| 2 | Supply, installation, testing and commissioning of silent Diesel Engine Generating set of 500 KVA capacity all as per CPCB-IV + norms, 415 Volts 3 Phase, 0.8 Power Factor, 50 Hz, 1500 RPM, self excited, self regulated, brushless AC generator with AMF panel of suitable rating including accoustic enclosure suitable for ambient condition at sea area and conforming to Engine as per IS : 10002, ISO-3046, BS-5514 and Alternator as per IS: 4774, BS EN 60034-1 with all necessary accessories for proper functioning of DG set including PCC Foundation, GI Pipe for laying of cable etc all as per manufacturers instructions complete all as specified in Particular specifications and as directed by Engineer-in-charge. | 2 | Each Job | - | - |
| 3 | Supply, laying & testing, replacement LT UG XLPE cable, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) earth system with stranded aluminium conductor, 1100 volts grade of size 3.5 core 630 sqmm and conforming to IS all as specified and directed. | 114 | RM | - | - |
| 4 | Supply, laying & testing, replacement LT UG XLPE cable, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) earth system with stranded aluminium conductor, 1100 volts grade of size 3.5 core 400 sqmm and conforming to IS all as specified and directed. | 140 | RM | - | - |
| 5 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying pipe lines, cables etc and nexc 1.5 m in depth and getting out hard / dense soil complete including taking out cables, cable cover all as specified and directed. | 31 | Cum | - | - |
| 6 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying pipe lines, cables etc and nexc 1.5 m in depth and getting out soft / loose soil complete including taking out cables, cable cover all as specified and directed. | 29 | Cum | - | - |
| 7 | Returning, filling-in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm using excavated soil all as specified and directed. | 32 | Cum | - | - |
| 8 | Removing excavated materials to a distance not exceedcing 50 meters and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed. | 27 | Cum | - | - |
| 9 | M&L for Unreinforced Precast Cement Concrete Cable Covers, Class LV Type - 1, Flat, size 250mm X 150mm X 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and directed. | 1,300 | Each | - | - |
| 10 | Supply and spread clean dry river sand as cable cushioning for protection of underground cable to be laid in trenches / transformer yard / two pole structure etc complete all as specified and directed.
(Note: Punned down thickness will only measured for the purpose of payment.) | 20.25 | Cum | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_858533.xls
BOQ • 0.73 MB
Tender.pdf
Tender Documents • 0.85 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .