| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC ANAND VIHAR COLONY WARD NO 01 FULUNGA RUDRAPUR DISTT UDHAMSINGH NAGAR PIN 263153 | UDAM SINGH NAGAR | UTTARAKHAND | 263153 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.9 L+₹9,150 (1.58%)Rejected-Finance JUNIOR A 3 CIVIL LINES MAKKA MILL RAMPUR UP PIN 240901 | 240901 | L2 | Rejected-Finance Being L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical As per the recommendeation of TEC Board and Concurrence by Finance Wing, being electrical work, the firm does not possess Electrical Licence hence does not fulfill the conditions of NIT, hence recommended to Rejected for next stage |
| Sl No | Description | Qty | Unit | MAHI TRADERS L2 | ADVANCE ELECTRICAL CONTROL SYSTEM L1 |
|---|---|---|---|---|---|
| 1.00 | Providing and Fixing EPCOS BR 6000-R12 (part No B44066R6012E230 12 step Automatic Power Factor Controller (APFC) relay designed for industrial 3 phase AC applications for automatic switching of 200 KVAR Capacitor Bank | 1 | Nos | 1,58,500 ₹1,58,500 Lowest | 1,59,000 ₹1,59,000 |
| 2.00 | Service Works of APFC Panel by carrying out following operations:-
1) Visual inspection ( Check for physical damage, loose conections, dust accumulation, Inspection of capacitor Banks for bulging or leakage, Checking of Panel Indicators, MCB's, MCCB's, Contactors, Relays and Fuses)
2) Cleaning Operation (Power Off and clean internal components, Using dry blower or vaccum cleaner, Removing dust from busbar, terminals, capacitors etc)
3) Tightening Operation (Tighten all electrical connections with torque wrench as per specification)
4) Capacitor Testing (Measure Capacitance and compare with rated value, Check for swelling, Oil Leakage or Overheating, Replacing weak or failed capacitor banks)
5) Contactor and Relay Check (Testing Contactors and relays for proper operation, Replacing Pitted or damaged Contacts)
6) APFC Relay/Controller Check (Verify proper working of the APFC relay, Check programming and power factor setting, perform functional test)
7) Thermal Scanning (if applicable)
8) Earthing and Insulation (Check Earthing continuity and insulation resistance, Megger test for cable insulation) | 1 | Job | 14,600 ₹14,600 | 11,950 ₹11,950 Lowest |
| 3.00 | Repair of Transformer 1000 KVA by providing side cover gasket packing, OLTC Controller, 18 Core 1.5 mm copper wire 40 Mtrs, Contactor 03 Nos, Add Block 03 Nos, Push Button Limit Switch, Remote Tap Changer Controller, Sundries Items with OlTC and Control Panel, Hardware and Service Charges | 1 | Nos | 1,99,870 ₹1,99,870 Lowest | 2,04,500 ₹2,04,500 |
| 4.00 | Service Charge for OLTC and RCTC Panel by carrying out following operations:-
1) Core and Coil Inspection
2) OLTC Mechanism Servicing
3) Insulation Testing
4)Bushing Cleaning
5)Oil Filtration
6)Tap Changer Cleaning | 1 | Job | 12,800 ₹12,800 | 9,970 ₹9,970 Lowest |
| 5.00 | Providing and Fixing MCX 34 MCX 34, the 04 Pole 450 A Magnetic Contactor Relay designed for industrial 3 Phase AC Applications, Timer 2 Nos AUX 2 Nos 2 NC Relay for automation of DG Set 160 KVA | 1 | Nos | 1,65,000 ₹1,65,000 | 1,60,000 ₹1,60,000 Lowest |
| 6.00 | Service Works of AMF Panel by carrying out following operations:-
1) Checking and Replacing damaged Relays and Contactors
2) Test and Replace Battery or Battery Charger
3) Inspect Wire harness, terminals, tighten or rewire as needed
4) Reset Controller, if damaged, replacethe controller board
5) Calibrate or Replace Faulty Sensors
6) Check Circuit Breaker, Lubricant or replace them, if stuck or faulty | 1 | Job | 8,900 ₹8,900 | 6,000 ₹6,000 Lowest |
| 7.00 | Repair of VCB Breaker : Providing and Fixing VCB Power Bank DC Battery 220 V AC Output 110 VDC & 24 DC and servicing and overhauling of ACB's 6 Nos completely | 1 | Job | 21,900 ₹21,900 Lowest | 24,000 ₹24,000 |
| 8.00 | Service Works of VCB by carrying out following operations:-
1) Visual inspection ( Check for physical damage, dustor oil leakage (in older units). Inspection of insulato, Contactors an operating mechanisms for signs of wear. Fixing Loose connections or burnt components.
2) Contact System (Inspect contract for wear or pittings, Replacing worn contact, Meaure Contact Resistance, Cleaning Contacts using proper tool and solvents)
3) Operating Mechanism (Check for peoper mechanical operations, Lubricate Moving Parts, Inspect and test motors, springs and Latchning Mechanism)
4) Vaccum Interrupters (Perform a vaccume integriry test, Replacing Vaccum Interuupter if required) 5)Electrical Testing (Insulation Resistance Test, Contact timing Test to insure proper functioning) | 1 | Job | 8,000 ₹8,000 | 5,000 ₹5,000 Lowest |
Tender Value
₹5.9 L
EMD Value
₹11,896
Closing Date
16 Sept 2025, 11:30 amClosed
Assistant Commandant (Engineer)
O/o THE DIG, GROUP CENTRE CRPF, RAMPUR (U.P) PIN-244901
Electrical Repair Works of APFC 200 KVAR Panel RCTC OLTC Panel at GC CRPF RampurTransformer and AMF Panel at Substation No 01
2025_CRPF_876712_1
B-V(GC Rampur)/2025-26-Minor Works(NIT-13)
Open Tender
Electrical Works
Item Rate
30 days
GC CRPF Rampur
As per TE
16 documents required · 16 mandatory
₹0
₹11,896
27 Sept 2025
10 Sept 2025
17 Sept 2025
10 Sept 2025
16 Sept 2025
10 Sept 2025
Amount
Providing and Fixing EPCOS BR 6000-R12 (part No B44066R6012E230 12 step Automatic Power Factor Controller (APFC) relay designed for industrial 3 phase AC applications for automatic switching of 200 KVAR Capacitor Bank
Service Works of APFC Panel by carrying out following operations:- 1) Visual inspection ( Check for physical damage, loose conections, dust accumulation, Inspection of capacitor Banks for bulging or leakage, Checking of Panel Indicators, MCB's, MCCB's, Contactors, Relays and Fuses) 2) Cleaning Operation (Power Off and clean internal components, Using dry blower or vaccum cleaner, Removing dust from busbar, terminals, capacitors etc) 3) Tightening Operation (Tighten all electrical connections with torque wrench as per specification) 4) Capacitor Testing (Measure Capacitance and compare with rated value, Check for swelling, Oil Leakage or Overheating, Replacing weak or failed capacitor banks) 5) Contactor and Relay Check (Testing Contactors and relays for proper operation, Replacing Pitted or damaged Contacts) 6) APFC Relay/Controller Check (Verify proper working of the APFC relay, Check programming and power factor setting, perform functional test) 7) Thermal Scanning (if applicable) 8) Earthing and Insulation (Check Earthing continuity and insulation resistance, Megger test for cable insulation)
Repair of Transformer 1000 KVA by providing side cover gasket packing, OLTC Controller, 18 Core 1.5 mm copper wire 40 Mtrs, Contactor 03 Nos, Add Block 03 Nos, Push Button Limit Switch, Remote Tap Changer Controller, Sundries Items with OlTC and Control Panel, Hardware and Service Charges
Service Charge for OLTC and RCTC Panel by carrying out following operations:- 1) Core and Coil Inspection 2) OLTC Mechanism Servicing 3) Insulation Testing 4)Bushing Cleaning 5)Oil Filtration 6)Tap Changer Cleaning
Providing and Fixing MCX 34 MCX 34, the 04 Pole 450 A Magnetic Contactor Relay designed for industrial 3 Phase AC Applications, Timer 2 Nos AUX 2 Nos 2 NC Relay for automation of DG Set 160 KVA
Service Works of AMF Panel by carrying out following operations:- 1) Checking and Replacing damaged Relays and Contactors 2) Test and Replace Battery or Battery Charger 3) Inspect Wire harness, terminals, tighten or rewire as needed 4) Reset Controller, if damaged, replacethe controller board 5) Calibrate or Replace Faulty Sensors 6) Check Circuit Breaker, Lubricant or replace them, if stuck or faulty
Repair of VCB Breaker : Providing and Fixing VCB Power Bank DC Battery 220 V AC Output 110 VDC & 24 DC and servicing and overhauling of ACB's 6 Nos completely
Service Works of VCB by carrying out following operations:- 1) Visual inspection ( Check for physical damage, dustor oil leakage (in older units). Inspection of insulato, Contactors an operating mechanisms for signs of wear. Fixing Loose connections or burnt components. 2) Contact System (Inspect contract for wear or pittings, Replacing worn contact, Meaure Contact Resistance, Cleaning Contacts using proper tool and solvents) 3) Operating Mechanism (Check for peoper mechanical operations, Lubricate Moving Parts, Inspect and test motors, springs and Latchning Mechanism) 4) Vaccum Interrupters (Perform a vaccume integriry test, Replacing Vaccum Interuupter if required) 5)Electrical Testing (Insulation Resistance Test, Contact timing Test to insure proper functioning)
MAHI TRADERS (BID ID -3283273)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .