| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹11.4 L+₹1.5 L (15.0%)Rejected-AOC | L2 | Rejected-AOC R | |
| 3 | L3₹12.8 L+₹2.9 L (28.9%)Rejected-AOC 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L3 | Rejected-AOC R | |
| 4 | L4₹12.9 L+₹3.0 L (30.1%)Rejected-AOC | L4 | Rejected-AOC R | |
| 5 | L5₹13.7 L+₹3.7 L (37.6%)Rejected-AOC A 16 SHIV LOK COLONY RAJPUR ROAD DEHRADUN 248 008 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248008 | L5 | Rejected-AOC R |
Tender Value
₹15.5 L
EMD Value
₹31,000
Closing Date
3 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
PROVISION OF TAMPER PROOF PREPAID ELECTRONIC METER IN LIEU OF CONVENTIONAL METERS AT IMA DEHRADUN
2020_MES_358613_1
GE/IMA/38 of 2020-21 8946/E8
Open Tender
Support/Maintenance Service
Item Rate
120 days
GE IMA Dehradun
Ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹31,000
Yes
10 Aug 2020
6 Jul 2020
5 Aug 2020
6 Jul 2020
3 Aug 2020
21 Jul 2020
60 days
Amount
Supply and Installation Testing and Commissioning of of ISI marked single phase electronic, 10-60A, accuracy class 1.0 keypad Prepaid meters conforming to IS 15884 with Consumer Interface Unit (CIU) and provisions for TOD (Time of Day) tariff and RTC (Real Time Clock). The meter should have inbuilt bi-stable type latching relay as per IS 15884. The Meter should comply to IS: 15884 / 2010 : Alternating Current Direct Connected Static Prepayment Meters for Active Energy (Class 1and 2) – Specification.Operating temperature range – 10 Deg.C to + 65 Deg.C . The meter should be capable of recording 30 minutes integrated values for kWh and kVAh and 30 minutes average values for Voltage and Current for the last 60 days on non-time based basis. The meter & CIU should must have RS485 Port. The cost inclussive of Implementation of vending system,software installation, database, designing, traning and transaction charges for 1 year. The Meter manufacturer should have there authorised service center within 10 Km radius of IMA to ensure trouble free operations. Meter should be housed in polycarbonate box with locking system. The base and cover should be ultra-sonically welded (continuous welding) so that once the meter is manufactured and tested at factory, it should not be possible to open the cover at site except the terminal cover and any non-permanent deformation cannot prevent the satisfactory operation of the meter. All the cost of prepaid meter & its accessories including RJ 11 cable etc are included in this Job complete all as directed by Engr-in-charge, Make : L & T /Secure/Legrand
Supply Installation Testing and Commissioning of of ISI marked Three phase electronic, 10-60A, accuracy class 1.0 keypad Prepaid meters conforming to IS 15884 with Consumer Interface Unit (CIU) and provisions for TOD (Time of Day) tariff and RTC (Real Time Clock). The meter should have inbuilt bi-stable type latching relay as per IS 15884. The Meter should comply to IS: 15884 / 2010 : Alternating Current Direct Connected Static Prepayment Meters for Active Energy (Class 1and 2) – Specification.Operating temperature range – 10 Deg.C to + 65 Deg.C . The meter should be capable of recording 30 minutes integrated values for kWh and kVAh and 30 minutes average values for Voltage and Current for the last 60 days on non-time based basis. The meter & CIU should must have RS485 Port.The cost inclussive of Implementation of vending system,software installation, database, designing, traning and transaction charges for 1 year. The Meter manufacturer should have there authorised service center within 10 Km radius of IMA to ensure trouble free operations. Meter should be housed in polycarbonate box with locking system. The base and cover should be ultra-sonically welded (continuous welding) so that once the meter is manufactured and tested at factory, it should not be possible to open the cover at site except the terminal cover and any non-permanent deformation cannot prevent the satisfactory operation of the meter. All the cost of prepaid meter & its accessories including RJ 11 cable etc are included in this Job complete all as directed by Engr-in-charge Make : L & T /Secure/Legrand
Sub main wiring with two single core PVC insulated unsheathed FR cable 1100 Volt grade, 6.0 Sqmm size with multi stranded copper conductor drawing into and including PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 6 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB complete all as directed. Make of wire : Finolex, Plaza, Havells, Polycab NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Sub main wiring with four single core PVC insulated unsheathed FR cable 1100 Volt grade, 6.0 Sqmm size with multi stranded copper conductor drawing into and including PVC conduit in surface/concealed as required including two run single core PVC insulated unsheathed 6 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB complete all as directed. Make of wire : Finolex, Plaza, Havells, Polycab NOTE: (i) Four run of single core PVC cable with two run of earth conductor and conduit shall be measured as one unit.
Supply and installation desktop ,i5 4 GB ,key board,intel CPU all in one desktop with UPS complete all as directed.Make : Dell Model No inspiron 24 3477 or equivalent as approved by GE. Make - Destkp computer- Dell- Dell Model No - inspiron 243447. UPS Mode APC Bacl UPS BS 1100C or equivalent as approved by GE
Supply and installation multi function printer of Make:EPSON Model No L 3150 or equivalent as approved by GE
Earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. NOTE: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted. (iii) If the desired earth resistance is not found within permissible limit shall be re done by contractor at no extra cost.
Balraj and Co
M/S AUTOMATION AND SWITCHGEAR CONTROL
Amit Engineering
M/s Anamika Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .