Executive Engineer (Civil)
Executive Engineer BSNL Civil Division Jabalpur
building Works
2022_BSNL_138307_1
EECD/BSNL/JBP/2022-23/31 (3rd call)
Open Tender
Civil Works - Buildings
Item Rate
300 days
Satna
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
Accounts Officer(Cash) BSNL O/o The GMTD Jabalpur
₹11,400
Yes
31 Jan 2023
19 Dec 2022
11 Jan 2023
19 Dec 2022
9 Jan 2023
19 Dec 2022
Amount
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : a) All kinds of soil
Pipes, cables etc, not exceeding 80 mm dia.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Cutting and uprooting unwanted matured Plant grown enough with branches and roots spreading on area of wall face, service shaft, roof, sanitary fitting, water supply, chajjas or any other location all complete as per the direction of Engineer-in-charge.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in foundations and plinth in :
Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Kiln seasoned and chemically treated hollock wood.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)
Kiln seasoned and chemically treated hollock wood i )35 mm thick shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :
Ply wood 5 ply, 9 mm thick : Decorative plywood one side decorative veneer and commercial veneer on other face (Type 1) conforming to IS 1328 BWR Type
Particle Board 12 mm thick Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS:3097, grade I
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
Kiln seasoned and chemically treated hollock wood 30 mm thick
Deduct for not providing hinges in doors, windows or clerestory window shutters with : ISI marked M.S. pressed butt hinges bright finished of required size. For 2nd class teak wood and other class of wood shutters.
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : a) 35 mm thick shutter i) with ISI marked M.S. pressed butt hinges bright finished of required size - Kiln seasoned and chemically treated hollock wood.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : a) 150x10 mm
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail.
Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing . a) 30 mm thick plain PVC door shutters.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. a)40 mm thick with 20 mm nominal size stone aggregate
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. a) 18 mm Thick
Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. a) 40 mm wide and 4 mm thick.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : a) 25 mm thick.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing in white cement mixed with pigment of matching shade complete.
Deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3kg/sqm
Fixing glazed/ Ceramic/ Vitrified floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm thickness.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design a) In 75x75 mm deep chase
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i)Single socketed pipes. a) 75 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.
Coupler 75mm
Coupler 110mm
Single tee with door 75x75x75 mm
Single tee with door 110x110x110 mm
Bend 87.5° 75 mm bend
Bend 87.5° 110 mm bend
12 mm cement plaster of mix : a)1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
Neat cement punning
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work (two or more coats) over and including water thinnable priming coat with cement primer.
Applying priming coat : With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
French spirit polishing : Two or more coats on new works including a coat of wood filler.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
One coat.
Two coats.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.
White washing with lime to give an even shade : Old work (two or more coats) .
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work.
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).
Rubbing and polishing of old mosaic flooring/terrrazo tiles with floor grinding machine including removing malba etc. all complete as per direction of Engineer-in-Charge.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. With cement mortar 1:4 (1cement: 4 coarse sand).
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.
Door chowkhats .
Window chowkhats .
Fixing chowkhat in existing opening in brick / RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener.
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm).
Renewing glass panes, with wooden fillets wherever necessary:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm).
Renewing glass panes and refixing existing wooden fillets:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm).
Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm).
Supplying and fixing new wooden fillets wherever necessary:
Hollock wood fillets.
Renewal of old putty of glass panes (length) .
Refixing old glass panes with putty and nails .
Fixing old glass panes with wooden fillets (excluding cost of fillets) .
Regrading terracing of mud phaska covered with tiles or brick, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand) including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per directions of Engineer-In-Charge.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer?in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial de-silting of manholes and de-chocking of sewer lines. De-chocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth.
Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-
(i) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in- charge.
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.
Orissa pattern W.C Pan of size 580x440 mm
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Provision of Plumber services to carry-out investigation of blockage in water supply, rectifying it properly and re-assuming supply to normal condition all complete as per the direction of Engineer-in-charge
Provision of Carpenter services to carry-out petty maintenance work all complete as per the direction of Engineer-in-charge.
Provision of Beldar services to assist Plumber/Carpenter/Mason in petty maintenance works all complete as per the direction of Engineer-in-charge
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge..
In cement mortar
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured):
From brick work in cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Of area beyond 3 sq. metres
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead:
Of area 3 sq. metres and below
Of area beyond 3 sq. metres
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles 10 mm to 25 mm
For thickness of tiles above 25 mm and up to 40 mm
Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge:
Up to 150 mm diameter
Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Credit for old dismantled/unserviceable material: -
Old brick bats/brick tile bats
Scraped Iron/Cast iron/ steel/M.S section/M.S rolling shutter/M.S tubes/MS bar /cast iron etc.
Brass bib cock/stop cock/ball valves/CP bibcock/CP stopcock/C.P angle cock/ brass gate valves/CP pillar cock.
CP shower rose// CP brass ring/CP brass towel rail etc. of all dia
Hydraulic Door Closer/door floor spring
Unserviceable door/window shutter (wood) i/c fittings
Unserviceable door/window shutter with or without chowkhats(steel) i/c fittings
PTMT Bib cock/stop cock/ball cock/WC seat cover/ internal fitting of low level PVC cistern etc.
PVC/China ware low level cistern
PVC water storage tanks upto 1000 litres
CP waste/CP gating of all sizes
PVC Connection/PVC waste pipes
Old M.S /aluminium fittings of all sizes like handle, tower blots, sliding door bolt, door stoppers,window fasteners, window stay, helical door spring , hinges etc.
GI pipes and fittings 15mm nominal bore
GI pipes and fittings 20mm nominal bore
GI pipes and fittings 25mm nominal bore
GI pipes and fittings 32mm nominal bore
GI pipes and fittings 40mm nominal bore
Old Aluminium section/old aluminium scrap etc.
Old 12 mm laminated board/ply
Scrap wood / fuel wood
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
10 litre capacity - White
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete :
White solid plastic seat with lid
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe 32 mm dia
Providing and fixing soil, waste and vent pipes :
100 mm dia. Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989.
75 mm diameter : Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
75 mm dia pipe
100 mm dia pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
100 mm dia Sand cast iron S&S as per IS - 3989
75 mm dia Sand cast iron S&S as per IS- 3989
Providing and fixing plain bend of required degree.
100 mm dia Sand cast iron S&S as per IS : 3989
75 mm dia Sand cast iron S&S as per IS - 3989
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
100x100x100 mm Sand cast iron S&S as per IS - 3989
75x75x75 mm Sand cast iron S&S as per IS - 3989
Providing and fixing collar:
100mm Sand cast iron S&S as per IS - 3989
75 mm Sand cast iron S&S as per IS- 3989
Providing and fixing CP brass waste 32mm in wash basin/ urinal pots all complete as per the direction of Engineer-in-charge
Cleaning/attending chocked floor traps, gully traps, and like i/c disposal of wastes to the appropriate point and spreading disinfectant (phenyle ) around the area after properly cleaning complete in all respect as per the directions of Engineer-in-charge.
Cleaning of existing choked SCI pipes by roding after removing the plug door & refixing the same with necessary rubber washers , spreading disinfectant (phenyl) etc. complete as per the directions of Engineer-in-charge.( Rate includes all the operation involved in the work)
75 mm to 100mm dia. SCI pipe(Full length from choke area / terrace to ground).
Clearing and Cleaning chocked manhole including sewer line by any suitable means, i/c cleaning the site for sewage, disposal of sewage testing, spreading disinfectant (Phenyle) after cleaning the surrounding area complete in all respect as per the directions of the Engineer-in-charge.
Cleaning / attending chocked WC seat (European/Indian/ Anglo Indian) i/c cleaning of floor, spreading phenyl etc.& disposal of unwanted material complete in all respect as per the directions of Engineer-in-charge. (Note:- Measurement will be made for individual seat).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
15 mm nominal outer dia. Pipes.
20 mm nominal outer dia. Pipes.
25 mm nominal outer dia .Pipes.
40 mm nominal outer dia. Pipes.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.
15 mm dia. nominal bore
20 mm dia. nominal bore
25 mm dia. nominal bore
40 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work
25 mm dia. nominal bore
40 mm dia. nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
25 mm nominal bore
20 mm nominal bore
15mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
15 mm nominal bore
20 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :
30 cm length 15 mm nominal bore
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required :
15 mm nominal bore.
20 mm nominal bore.
25 mm nominal bore.
40 mm nominal bore.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931:
15 mm nominal bore.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
15 mm nominal bore.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :
15mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing PTMT bib cock of approved quality and colour.
15 mm nominal bore, 122 mm long. Weighing not less than 99 gms.
Providing and fixing PTMT stop cock of approved quality and colour.
15 mm nominal bore, 86 mm long. Weighing not less than 88 gms.
20mm nominal bore, 89 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT pillar cock of approved quality and colour .
15mm nominal bore, 107 mm long. Weighing not less than 110 gms.
Providing and fixing polyethylene water storage tank lid
500 litre capacity
1000 litre capacity
Restraining leakage from toilet/ kitchen floor trap, from adjoining walls and the like of upper floor to lower floor by applying/ grouting cement slurry /paste with water proofing material and other approved chemical around floor trap properly complete in all respect as per the directions of the Engineer-in-charge.
Rectification of water leakage problem / air lock complete in all respect including making necessary threading if required, replacing washers & providing jute packing/ safeda in wheel valve, flushing cistern, Inlet & outlet points of water tanks, joints of water supply pipe line, cracks of water supply line etc. all complete as per the directions of the Engineer-in-charge.
Rectification of tap leakage by replacing washer / jumper etc. from the bibcock / stopcock/ pillar cock and alike complete in all respect as per the directions of Engineer-in-charge.
Replacing unserviceable / missing ball in water storage tanks by providing & fixing new ball of approved quality:-
15mm nominal bore
Dismantling 15 to 40 mm dia G.I. pipe necessarily required for the purpose of maintenance rectification including stacking of dismantled pipes (within 50 metres lead) and also re-fixing the pipe after required maintenance rectification in proper order all as per the direction of Engineer in-Charge.
Supplying and fixing C.I. cover without frame for manholes :
455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness.
PRINCI CONSTRUCTION
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .