Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Being L1 and reasonable. |
| 2 | L2₹1.4 Cr+₹5.4 L (4.05%)Rejected-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹1.4 Cr+₹5.4 L (4.05%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹1.5 Cr+₹13.4 L (10.1%)Rejected-Finance SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | ₹1.5 Cr+₹13.4 L (10.1%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹1.5 Cr+₹15.9 L (11.9%)Rejected-Finance GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹1.5 Cr+₹15.9 L (11.9%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹1.5 Cr+₹17.1 L (12.9%)Rejected-Finance 310 D KAMBAL WALA BAGH RAJWAHA ROAD NEW MANDI MUZAFFARNAGAR U P 251001 | MUZAFFARNAGAR | UTTAR PRADESH | 251001 | ₹1.5 Cr+₹17.1 L (12.9%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹1.6 Cr
EMD Value
₹2.4 L
Closing Date
20 Mar 2021, 6:00 pmClosed
Chief Engineer Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly Cantt Bareilly 243001
ADDN / ALTN CUM SPECIAL REPAIRS TO JCOs/OR MD AND FIELD AREA FAMILY ACCN AT SUPPLY DEPOT DEHRADUN
2021_MES_420037_1
CEBZ/DDN/T-22 OF 2020-21
Open Tender
Civil Works
Item Rate
365 days
DEHRADUN
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (P) Dehradun
₹2.4 L
Yes
12 Apr 2021
11 Feb 2021
25 Mar 2021
11 Feb 2021
20 Mar 2021
8 Mar 2021
12 Feb 2021 - 4 Mar 2021
Amount
SCHEDULE 'A' PART- I (BUILDING WORK INCLUDING SPECIAL WORKS)
Demolition of cement concrete (un-reinforced ) of any description & in any position not specifically provided for complete including dismantling of floor tiles etc including rubbish off the premises complete all as specified and as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided including rubbish of the premises complete all as specified and as directed.
Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitions etc including rubbish of the premises complete all as specified and as directed.
M & L not less than 18 mm thick granite(of any type & coloured) stone slab machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing as in kitchen platform/dado/skirting /plateform counter top WHB including cutting holes for oval shape /urinal partitions etc. over including 20 mm thick cement screed bed in CM 1:4 in horizontal surfaces including grinding the edges half round and polishing complete all as specified and directed by Engineer-In- Charge.
All as per item no 5 above but 15 mm thick rendering in CM 1:4 on vertical surfaces complete all as specified and directed.
Dismantling of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified and as directed
M & L for brick work with sub class ‘B’ bricks straight or curved on plan in CM 1:4 as in half brick thick walls complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4 Sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed
S & F 1.25 mm thick pressed steel frame of size 165 mm X 60 mm for door with one ore more rebate includings necessary fixing lugs, hinges, locks strike plate etc complete all as specified and as directed
M & L for MS framed work as in grills, grating etc with ends of bars shouldered and / or riveted or forged into spikes framed guard bars barred iron doors, ladders framed baluusters walls ways, railing framed work of water tanks and similar work etc complete all as specified and as directed
S & F 35 mm thick factory made flush shutter solid core construction with block board core and ply wood face panels, commercial type on both sides complete all as specified and as directed
S & F 2nd class hard wood factory made 35 mm thick glazed and skeleton shutters open rebated and prepared to rceieve glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as specified in SSR Part-1, Section 8, clause 8.24 (a) etc complete all as specified and as directed
S & F factory made steel windows (Box Type) with side hung shutters precoated (colour coated / powder coated) with double shutter (glazed and gauged shutter both) with frame complete all as specified and directed and shown on Drg TD 158 Sheet 1/2 & sheet 2/2. Note :- Measurements shall be taken and paid compositly for frame, glazed and gauged. Grill shall be measured and paid seperately under respective item. No extra claim shall be entertained on this ground.
M & L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint complete all as specified and as directed.
S & F FRP door frame 100 mm x 50 mm made out of 3 mm thick coloured Prelaminated FRP sheet with UV grade polyester Resin fixed with 6mm dia 100 mm long screw and rawl plugs complete all as specified and directed by Engineer-In- Charge.
S & F 30 mm thick FRP door shutters with UV Grade polyester Resin with minimum 3 mm thick coloured prelaminated FRP sheet fixed on both sided and complete all as specified and directed by Engineer-In- Charge.
S & F stainless steel 100 mm long butt hinges for PVC door shutters and frames complete all as specified and directed by Engineer-in-Charge.
S & F 18 MM thick plywood coated with fiber reinfored plastic (FRP) 3 mm laminated on both faces (3mm + 12mm + 3 mm ) and edges to be sealed with PVC edges binding tape for cupboard shelf and shutter complete all as specified and directed by Engineer-in -charge
S & F Aluminium anodised tower bolt 200 mm long of extruded section etc complete all as specified and as directed.
S & F aluminium alloy, anodised sliding door bolt 300 mm long and 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy etc complete all as specified and as directed.
S & F 150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed.
S & F 150 mm double legged floor door stopper aluminium alloy with rubber etc complete all as specified and as directed
S & F ball catcher with 8 mm dia steel ball magnet catches for cupboard shutter including strking plate as approved etc complete all as specified and as directed
S & F continous (piano) hinges, mild steel, bright finish or eletro galvanised width of flap (when open) 30 mm etc complete all as specified and as direced
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire stapel etc complete all as secified and as directed
S & F sheet glass ordinary quality 4mm thick and glazing with oil putty or fixed with bead/ glazing pins in squares n.exc. .5 sqm each pane all corner of glass to be fixed with silicon complete all as specified and directed.
S & F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5 sq. m in each pane complete all as specified and directed.
S & F in repair mild steel helical door spring 150 mm longe ordinary rat tail type incl roller and roller plate complete fixed with screws to wooden frames or with welding to steel frames complete all as specified and directed
M & L PCC 1:3:6 Type C0 using 12.5 mm graded stone aggregate for filling of pressed steel door frame complete all as specified and directed by Engr-in Charge
S & F in repairs MS Powder coated decorative curtain rod of 25 mm bore with including brakets 02 nos flanges 02 nos) etc complete all as specified and as directed
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified and as directed
M & L for rendering 5 mm thick in CM (1:3) on fair faces of brick work or concrete to be finshed even and smooth without using extra cement over 10 mm thick in 1:3 as dobbing coat after applying one coat of alkaline anticorrosion chemical coating having specific gravity of 1.2 to 1.22 upon exposed reinforcement with water proofing compound as per manufacture instruction etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately
M & L for rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed
M & L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surface finished even and fair mixed with water proofing compound as per manufacture instruction etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately
M & L for rendering 10 mm thick in CM (1:3) on RCC Chajja / Facia over 20mm thick in CM 1:4 as doubing coat etc complete all as specified and as directed
Supply only Liquid water proofing compound complete all as specified and as directed.
M & L three coats of white wash on ceiling on new plastered surfaces including preparation of surfaces complete all as specified and as directed
M & L three coats of white wash on ceiling on Old plastered surfaces including preparation of surfaces complete all as specified and as directed
M & L for applying two coat of oil bond distemper white or any tint over a coat of primer etc over prepared surface of putty complete as specified and directed
M & L for complete removal of existing treatment from wall upto plaster surface by washing, rubbing down and stopping of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces finally rubbed and smooth with sand paper all as directed by Engr-in-charge. Note : The work will be carried out upto tripple storey builing the rate of scaffolding is included for this item also.
M & L preparing new wooden surface of any description, not other wise described over 10 cm widht or girth and applying two coats of synthetic enamel paint etc complete all as specified and as directed
M & L preparing of old painted surfaces of wood & wood based surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed
M & L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth , not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
Taking down steel tubing & connections including cleaning for refixing serviceable pipe or removal balance pipe of 15 mm bore complete all as specified and as directed
S & F medium grade galvanized steel tubing with all fittings & fixed complete to walls & ceiling or laid in floors 15 mm bore pipe (including in short length) complete all as specified and as directed
Taking down steel tubing & connections including cleaning for refixing serviceable pipe or removal balance pipe of 20 mm bore complete all as specified and as directed
S & F tubes medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm bore pipe (including in short length) complete all as specified and as directed
M & L for cutting chases, pinning in brick / PCC blocks wall & making good to facings where required and pointing in cement mortar 1:3 n exc 10 cm wide for concealed water tubing etc and making good complete all as specified and as directed
Dismantling of cast iron or reinforced concrete drain pipe up to 100 mm dia, jointed in cement mortar and taking out from trenches if reqired etc complete all as specified and directed
S & F in repair for 75 mm bore out let cast floor trap with gratings including jointing to waste pipe fixed in cement concrete tpe B-1 (1:2:4) type B0 etc complete all as specified and as directed
S & F 50 mm bore Cast iron soil, waste and vent pipes (spun pipes), in any length with or without ears with cement joints, laid in trenches or in floors or fixed to wall vertically complete all as specified and as directed
S & F in repair for 75 mm bore Cast iron soil, waste and vent pipes (spun pipes), in any length with or without ears with cement joints, laid in trenches or in floors or fixed to wall vertically complete all as specified and as directed
S & F in repair for 100 mm bore Cast iron soil, waste and vent pipes (spun pipes), in any length with or without ears with cement joints, laid in trenches or in floors or vertically cast, complete all as specified and as directed
S & F 75 mm bore cast iron Bend (spun pipes) (any radius), diminishing piecs or tapers (larger bore measured) complete all as specified and as directed
S & F 100 mm bore cast iron Bend (spun pipes) (any radius), diminishing piecs or tapers (larger bore measured) complete all as specified and as directed
S & F 75mm bore cast iron Tee (any radius), diminishing piecs or tapers (larger bore measured) complete all as specified and as directed
S & F 100 mm bore cast iron Tee (spun pipes) (any radius), diminishing piecs or tapers (larger bore measured) complete all as specified and as directed
S & F 50 mm cast iron cowls complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B-0 using (12.5 mm graded stone aggregates) 25 mm thick as in sub base of flooring etc complete all as specified and as directed
M & L for Non Skid ceramic joint less tiles (colour) not less than 7 mm thick , (square / rectangular) area of each tiles exc 0.18 Sqm but n.exc 0.38 Sqm as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match including 15 ,mm thuick cement screed bed in CM 1:4 etc complete all as specified and as directed
All as per srl item no 62 above but in skirting/risers/dados with 10 mm thick rendering in CM 1:4 etc.complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding/backing, removing serviceable tiles to store and rubbish off the permises complete all as specified and directed by Engr-in-Charge
M & L for Non Skid ceramic tiles (colour) 7 to 8 mm thick , (square / rectangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc, set and jointed in neat cement slurry and pointed with white or coloured cement to match over & including 15 mm thick cement screed bed in CM 1:4 complete all as specified and as directedetc complete all as specified and as directed
M & L machine cut and machine polished kota stone slab flooring not less than 20 mm thick laid and jointed with grey cement slurry mixed with pigment to mtach the shade of the slab including rubbing and mirror / granite polishing over & including 20 mm thick cement screed bed in CM 1:4 complete all as specified and as directed.
M & L machine cut and machine polished kota stone slab not less than 20 mm thick in riser of steps, skirting, dado and pillars laid and jointed with grey cement slurry mixed with pigment to mtach the shade of the slab including rubbing and mirror / granite polishing over & including 10 mm thick cement rendering in CM 1:4 complete all as specified and as directed.
M & L for exterior grade, coloured glossy finish rubber pressed, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick (as approved GE) set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc. over and including 20 mm thick cement screed bed in CM 1:4 etc complete all as specified and as directed complete all as specifed and as directed
M & L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surface as backing coat coat of dado/skirting etc complete all as specified and as directed.
M & L Glazed ceramic tiles coloured 300 mm x 450 mm , 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match etc complete all as specified and and as directed
S & F in repair white vitreous china wash basin white flat back size corner type 300 mm size excluding taps but including 32 mm dia chromium plated waste fitting and PVC waste pipe 610 mm long and MS brackets complete all as specified and as directed.
S & F in repair stainless steel sink with drainage board 1.00mm thick for kitchen with plug/waste pipe washers including cantiliver bracket or, connecting unions etc over all size 915 mm x 460 mm with bowel size 410 mm x 330 mm x 160 mm complete all as specified and as directed.
S & F in repairs vitreous china squatting pan orissa pattern long pan size 580 mm x 440 mm white with spun pipe ‘P’ or ‘S’ trap, front or back inlet and foot rests excluding flushing cistern & flush pipe but incl. cement concrete bedding fixed complete all as specified and as directed.
S & F in repair tubular towel rail 20 mm dia type brass chrormium plated 600mm long between flanges complete all as specified and as directed.
S & F chromium plated shower roses 125 mm size with or without swivel joints of standard size including fixing to 15 mm steel pipe or union complete all as specified and as directed.
S & F in repair PVC valveless double syphonic action type flushing cistern low level of 10 Ltr capacity white with inlet ball valve, float, flushing bend & handle including brackets, suitable for both Indian Type Water Closet & Europeon Type Water Closet including brackets & connection to pipe & fixing of chain & pull or lever if including PVC pipe etc complete all as specified and as directed.
S & F in repair bib tap long body fancy type cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferrule or fixed for 15 mm dia bore pipe complete all as specified and as directed
S & F in repair stop valves/angle valves fancy type chromium plated brass cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions fixed for 15 mm dia bore pipe complete all as specified and as directed
All as per sr item no 79 above but fancy type, chromium plated with long shank and cup (concealed type) complete all as specified and as directed
S & F 15mm bore Pillar taps fancy type, cast copper alloy, with long swan neck , chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and as directed
S & F in repair Brass CP mixer (wall mounted type) for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and as directed
S & F Brass CP sink mixer (wall mounted type) for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and as directed
S & F PVC connection of 45 cm length including brass nuts complete all as specified and as directed
S & F kitchen plate rack stainless steel 1 mm thick of size 90 cm x 75 cm complete fixed to brick / concrete wall, with screw including rawl plug complete all as specified and as directed
M & L for cement concrete 1:2:4 type, B1 using 20 mm graded stone aggregates as in copings, roof padding/staging of water tank etc including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed
M & L for rendering 15 mm thick in CM (1:3) mixed with water proofing compound @ 3% by weight of cement finished even and smooth without using extra cement in sunken portion of toilet etc complete all as specified and as directed Note: WPC will be measured and paid separtely
M & L for applying evenly a coat of Dr fixit solution or other equivalent as per manufacturers instruction etc complete all as specified and as directed
M&L cement concrete 1:5:10 type E-2 using 40 mm graded stone aggregates as in sunken portion of WC etc complete all as specified and as directed
Removing excavated soil/Materials to a distance exc 1.50 KM mtr but not exceeding 5.00 KM mtr and depositing where directed etc complete all as specified and as directed
Taking down existing un-serviceable water proofing treatment from roof slab and cleaning the roof slab by wire brush and removing WPT felt exc 500 mtr but not exc 1.50 Km etc complete all as specified and as directed
Disconnecting existing tank of capacity exc 250 ltr but not exc 500 ltr, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position (cleaning repairing etc measured seperately) etc complete all as specified and as directed
S & F rotational moulded (three layered) polyethylene 500 Ltrs Capacity water storage tanks triple layered white in color with thread type cover (cylindrical vertical with closed top) hoisted and fixed in position in SSR Part-I all as specified and directed .
S & F 20 mm ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed etc complete all as specified and as directed
S & F as in repair Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe 20 mm bore complete all as specified and as directed.
M&L for rendering 15 mm thick in CM (1:3) on fair faces of brick work or concrete surface mixed with water proofing compound as per manufacture instruction etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately Notes :- Rates includes to carried out the work on roof slab up to 3rd stories building nothing extra shall be admissible on this account
M&L for 3 mm thick APP modified prefabricated in five layers & weight not less than 3.6 Kg/Sq mtr water proof membrane reinforced with non-wooven polyster with two coat of water proofing aluminium paint over top surface of water proofing membrane with 15 cm longitudinal & horizontal over lapping and joints finally pasted with thermo- fused with LPG flames laid over a coat bitumen @ 1.20 Kg /Sqm over a coat bituminous of primer 0.40 ltr per sqm over after cleaning existing plastered surfaces as per manufacturer instruction of APP modified membrane etc APP modified membrane shall be laid on primed surface by torch application method after allowing 24 hours for primer to dry, complete all as specified and as directed. Notes :- Rates includes to carried out the work on roof slab up to 3rd stories building nothing extra shall be admissible on this account
M&L for 75 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) as in sub base of flooing etc complete all as specified and as directed
M & L for post construction AntiTermite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M & L for post construction Antitermite along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
S & F tubes medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors 40 mm dia bore pipe (including in short length) complete all as specified and as directed
M&L for mild steel TMT bars 5mm dia and over upto and inclluding 10mm dia , cut to length, bent to shape required, incl cranking, bending spirally for roof beam, lintels, slabs and other similar structures, stirrups, spacers and binders etc., hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge
M & L for RCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in chajjas, fins, slabs, soffits etc complete all as specified and directed by Engineer-in-Charge
M & L for formwork to chajjas, soffits, cantiliver shelves etc.for rough finished flat/curved surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
S & F 9 mm thick (with min 5 nos of ply ) plywood grade BWR type BB, fixed with screws to timber frame work/ doors complete all as specified and directed by Engineer-in-Charge.
M & L preparation of old painted surfaces of steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed
M & L for preparation of new wall surface and applying wall putty 2 mm thick (Asian /Berger/JK) to make the surface smooth as specified and directed by Engr-in-Charge. (Note : The work will be carried out upto tripple storey builing the rate of scafolding is included for this item also)
M & L for preparation of old wall surface and applying wall putty 2 mm thick (Asian /Berger/JK) to make the surface smooth as specified and directed by Engr-in-Charge. (Note : The work will be carried out upto tripple storey builing the rate of scafolding is included for this item also)
M & L Two coat of whether proof exterior emulsion paint on brick / concrete plastered surface of walls all as specified in SSR Part I and directed by Engr-in-Charge . (Note : The work will be carried out upto tripple storey builing the rate of scafolding is included for this item also. Applying coat after completion of preparation of surface as per item as above and stage has to be passed by Engr-in-charge before complete all as specified and directed)
S&F for stainless steel (AISL 304 grade) non magnetic multilayer feuba nickel chrome plated for multipurpose utensils container of following size in each kitchen :- . (A) Plain basket of size 510X470X100 or 520X485X100 mm -01 No (B) Multi size plate basket of ize 510X470X150 or 520X485X150 mm 01 no (C) Cutlery basket, with perforated bottom & side of compacted/ slots for holding cutlery of size 510X470X100 or 520X485X100 mm 01 no (D) Plain basket of size 510X470X200 or 520X485X200 mm 01 no (E) Pull out with 02 baskets each ofb size 150 X 485 X 80 or 100 x 485 X 80 mm 01 no (F) Including frame work, telescopic channels, handles etc as required & all as specified sample & design to be approved by GE Make (Hettich/Hafole)
Taking down shutter of any description exc 1 sqmm but n.exc 2 sqm complete all as specifed and directed.
Re fixing and Re securing / easing of door shutter in same opening complete all as specified and directed.
S & F 25mm bore GI tubing medium grade withh all fittings and fixed to walls & ceilings or laid in floors complete all as specifed and directed.
M & L PCC 1:3:6 Type C1 (20mm graded stone aggregate) as in surface channel drain complete all as specified and directed.
SCHEDULE 'A' PART- II (Internal Electrification)
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed by Eng-in-charge.
M & L point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in existing concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule)
One light point /bell / buzzer point controlled by one-one way switch.
One ceiling fan / Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
One light point controlled by two two - way switch
M & L for new point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories including cutting charges except RCC nexc 10 cm width & making good in CM 1:3 with suitable size of sunk type cast iron or pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including contineous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. Cutting charges and making good shall be measured and paid seperately. (Note: Colour code shall be maintained as per IE rule)
(a) One light point / bell buzzer point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
(c) One three pin 5 Amp socket on independent board
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
All as per item No 114 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 2.5 Sq mm complete all as specified and directed.
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F switch paino flush button type 5 Amp SP 2 way complete 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp flush type complete all as specified & directed.
S&F Bell switch paino flush button type 5 Amp complete all as specified & directed.
S&F ding dong bell AC 230 V single pole complete all as specified and directed .
S&F stepped type electronic fan regulator flush type two module 400 Watt on the existing phenolic laminated sheet etc complete all as specified & directed.
S&F ceiling rose, 3 terminal / PVC / polycarbonate, isolated body 250 V AC complete all as specified & directed.
S&F lamp holder PVC / polycarbonate type with back plate suitable for batten fittings.250 V AC complete all as specified & directed.
M&L in replacement sub main wiring with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings with cutting & chasing nexc 10 cm and making good in CM 1:3 chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 6.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed including taking down old sub main wiring .
S&F in replacement sheet metal enclosures 240 volt with 200 amps rated copper bus bar for double door 8 way IP-43DB's lk-09suitable for one MCB SPN as incoming and 6 MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
S&F MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed .
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed .
S&F MCCB 415 Volt 16 KA 4 pole 63 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed.
S & F in replacement wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed including taking down old tube light fitting complete all as specified & directed. Make: Philips CAT part No TMC 100 1xT LED 13-20w WH (Tube Batten) MAS LED 1200mm 18W-865-T-81 / Wipro Cat part No WIO921208 (Tube Batten) LL13-181-650 (Tube) / Havells Cat Part No REGAL BATTEN T8 UPTO 1X20W SSBS WH ( Batten)PHOTONULTRAE2.01213T118WLED 865 SPC.
S&F wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed including taking down old tube light fitting complete all as specified & directed. Make: Philips cat part No TMC1001xT LED 13-20WH(Tube Batten) MAS LED 1200mm 18W-865-T-81 / Wipro Cat part No WIO921208 (Tube Batten) LL13-181-650 (Tube) / Havells Cat Part No REGAL BATTEN 8UPTO 1X20W SSBS WH( Batten) PHOTONULTRAE2.01213T118WLED 865 SPC.
S & F mirror light decorative compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size. complete all as specified & directed. Make : Philips Cat Part No BN021LED12S6500PSUGR / Havells Cat Part No LHESABP7IN1W0099W / Wipro Magma LED 10 Watt
S&F LED light fitting decorative wall mounting cast aluminium Polycarbonate bracket suitable for 9 watts LED bulbwith frosted glass with and including one no 5 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified & directed. Make:Havells Cat Part No: LHFOAJE1TNI1060 or equivalent in make specified hereinafter.
S & F high efficiency LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed. Make Philips Model Steller Bright High Wattage 15000 Life Hour / Havells cat Part No LHEAAB71L1W012 / C&S Cat Part no CRONA-RND 118 WW
Taking down & Refixing ceiling Fan any sweep single phase 230 volts with down rod , canopy, blades etc including painting of ceiling fan connecting with twisted three core flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan and writing MES NO on fan comlete all as specified and directed.
Supply & fix ceiling Fan 1200 mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three core flexible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan and writing MES NO on fan complete all as specified and directed .
S&F Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed .
S&F air ventilation fan matalic body 300mm, 900 RPM with louvers, single phase, 230V AC including necessary, M&L for making hole fixing arrangement on wall with frame holdfastner, bolt, washer etc including connection with twisted white three core flexible copper multistranded conductor cable from ceiling rose to connector all a directed by Engineer-in-charge.
M&L for earthing complete with using galvanized mild steel earth plate (electrode) 600 mm x 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plate using 4 mm dia GI earth lead wire as earth lead moulded and rivetted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead protected in and including 15 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) duly reinforced with MS bars 8mm dia @150 mm c/c both ways and lifting handles of 10mm dia roud MS bars etc as per electrical plate No.3 of SSR Part-II 2010 and testing on completion all as specified and directed.
Supply and Fixing in replacement Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 45 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours including GI brackete made out of 25 mm GI pipe medium grade and MS clamps for fixing of light fitting complete and connected with twin core PVC insulated copper flexible cable with existing point all as specified and directed. Make Philips cat Part No BRP056 LED 53 CW SLF PSU S1 (45W 5300 LUMENS STREET LIGHT) / Havells Cat Part No ENDURAPEARL NEO S145W, LED7S7PASYTOPC / C&S Cat Part No LTESS145W LED/LS
S & F of 20mm dia non metallic PVC conduit medium duty complete all as specified and directed.
S & F of 25mm dia non metallic PVC conduit medium duty complete all as specified and directed.
SCHEDULE 'A' PART- III (Sewage Disposal)
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose soil complete all as specified and directed by Engineer-In- Charge.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified and directed by Engineer-In- Charge.
Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil complete all as specified and directed by Engineer-In- Charge.
M&L for providing plain cement concrete 1:4:8 type D-1 (using 40mm graded stone aggregate) as in foundation and mass concrete complete all as specified and directed by Engr-In- Charge.
M&L for brick work with sub class 'B' bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-In- Charge.
M&L for providing precast cement concrete coping with plain fair faces incl chamferes, weathering, throating etc type B0, 1:2:4 using 12.5mm graded stone aggregate and set in CM 1:4 complete all as specified and directed by Engineer-In- Charge.
M & L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in bed to drain pipe 150 mm dia including packing under and haunching against the sides of pipes etc complete all as specified and directed by Engineer-In- Charge
M & L for reinforced concrete pipes,150mm dia class NP-3 laid and jointed complete with collars complete all as specified and directed by Engineer-In- Charge.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 mixed with water proofing compound finished even and smooth without using extra cement complete all as specified and directed by Engineer-In- Charge. (Water proofing compound shall be measure and paid separatelly).
Supply only liquid water proofing compound complete all as specified and directed by Engineer-In- Charge.
M&L for 15mm thick rendering on other than fair faces of brick work in CM 1 : 6 finished even and smooth without using extra cement complete all as specified and directed by Engineer-In- Charge.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150mm dia pipes complete all as specified and directed by Engineer-In- Charge.
M&L for mild steel TMT bars 10 mm dia and over cut to length and bent to shape required and binding with mild steel wire dia not less than 0.9 mm (annealed) complete all as specified complete all as specified and directed by Engineer-In- Charge
M&L for providing pre cast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cover slab and man hole covers etc complete all as specified and directed by Engineer-In- Charge.
S&F MS Flats, joist channel (Fe 410-W Gde E-250 Quality A), fixed indepently or framed without connecting plates confirming to Grade Fe 410-0 or Fe-310-0 complete all as specified and directed by Engr-in-Charge
M & L for extra over Cast iron pipe & fittings 100 mm bore if lead joint provided in lieu of cement joint complete all as specified and directed.
M & L for extra over Cast iron pipe & fittings 75 mm bore if lead joint provided in lieu of cement joint complete all as specified and directed.
M & L for extra over Cast iron pipe & fittings 50 mm bore if lead joint provided in lieu of cement joint complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 2,39,790.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
m/s gupta construction
OM TRADERS
PIONEER REFRIGERATION AND ELECTRICALS
BHAGAT JI ENTERPRISES
Ms Banco Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .