Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹30.6 L+₹5.2 L (20.3%)Rejected-Finance | L2 | Rejected-Finance Second Lowest | |
| 3 | L3₹31.9 L+₹6.5 L (25.4%)Rejected-Finance | L3 | Rejected-Finance Third Lowest | |
| 4 | L4₹32.0 L+₹6.6 L (26.0%)Rejected-Finance | L4 | Rejected-Finance Fourth Lowest | |
| 5 | L5₹33.6 L+₹8.2 L (32.1%)Rejected-Finance | L5 | Rejected-Finance Fifth Lowest |
Tender Value
Refer Docs
EMD Value
₹75,600
Closing Date
3 Mar 2022, 9:00 amClosed
Major Sameer Wadekar
Holta Cantt, Palampur
SPL REPAIRS TO BLDG NO A-16 (OTM ACCN) OF 14 FD REGT AND CERTAIN MINOR WORK AT ALHILAL MIL STN.
2022_MES_507230_1
GEP/ - /2021-22
Open Tender
Civil Works
Item Rate
180 days
Alhilal Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹75,600
Yes
11 Mar 2022
10 Feb 2022
5 Mar 2022
10 Feb 2022
3 Mar 2022
17 Feb 2022
Amount
SCHEDULE 'A' PART-I:- Dismantling of plain or corrugated steel sheeting, any gauge, thickness,including Nainital or similar pattern roof covering etc. complete all as specified and as directed.
S&F 0.63 mm thick corrugated, galvanised, mild steel sheeting having Zinc coating 120 gms per square metre with two corrugation side laps, fixed with 'L' or 'J' type cranked bolts in roof covering (Horizontal distance of side lap shall not be less than 145mm and depth of corrugation shall be 12.5mm), complete all as specified and directed.
S&F 0.63 mm plain, galvanised, mild steel sheeting, in ridges hips, valley gutters, drip and straight flashings (length and girth asfixed) with grade of zinc coating 275 complete all as specified and directed. ,
Dismantling timber scantling 40 sq.cm & over section, any position in any position complete all as specified and directed.
S&F 2nd class soft wood, as in scantling and similar work, clean sawn (framed/unframed) timber fixed in position, complete all as specified and directed.
S&F 2nd class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secu-red with nails, sectional area exc. 13 sqcm but n.exc. 25 sqcm complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 Cum , getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer n.exc 25 cm, watering, and removing surplus soil to a distance n.exc 50 mtr and making good surfaces in soft/loose soil complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed.
M&L preparation of new surface of steel of any description, over 10cm width or girth not other wise described and appliying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards/ slabs/ blankets of any thickness, including cover fillets complete all asspecified and directed.
S&F anodised aluminium snap grid frame work for false ceiling including hangers 6mm dia GI adjusting level fixed to roof slab by means of ceiling cleats made out of G.I. Flat 40 X 3 mm size 60mm long and expansion hold fasterns 12.5mm dia 40mm long complete all as specified and as directed.
M&L 8mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid both side laminate complete all as specified and directed. Note:-Frame work for ceiling shall be measured and paid separately
Demolition of brick work or stone /boulder masonry, built in CM, including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc, complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:6 complete all as specified and directed.
M&L walling of random rubble stone masonry uncoursed, with best quality locally available harder stones such as granite, trap, basalt stone etc, well bonded, bedded and solidly hearted, built in cement mortar 1:6 etc, complete all as specified
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided, complete all as specified and directed.
M&L RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate in footings,including rafts,footings,foundation beams,plinth beams; bases for columns,etc complete all as specified and directed.
M&L RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate in columns,pillars, piers,posts and struts,etc complete all as specified and directed
M&L RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate in beams,cantilevers, bressummers,lintels over 1.50m span, bands,etc complete all as specified and directed
M&L RCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and the like, complete all as spfd and directed.
M&L Form work to sides of concrete foundations, footing,bases of columns,raft and raft beams,sides and soffits (ifany) of foundation and plinth beams;and similar work;vertical or to batter for fair finished surfaces, complete all as specified and directed.
M&L Form work to sides and soffits of floor or roof beams,bands,beam haunchings,girders, bressummers,lintels,cantilevers,shelves including supports,overhangs,etc also splays between floors and beams for fair finished surfaces, complete all as specified and directed.
M&L Form work to sides of pillars,posts,struts piers,columns and stanchions for fair finished surfaces, complete all as specified and directed.
M&L Form work to sides and soffits of suspended slab, such as roof slab, floor slab, landing and similar work n.exc. 200mm thick (horizontal or sloping) for fair finished surfaces, complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape reqd, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia, complete all as spfd and directed.
S&F TMT bar 6 to 8mm dia and over, cut to length, bent to shape reqd, incl cranking, bending spirally for hooping for column, hooking end and binding with and incl mild steel wire (annealed) not less than 0.9mm dia, complete all as spfd and directed.
S&F mild steel TMT bars 5 mm dia and over up to 10 mm dia in stirrups,spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Demolition of floor, hearth or wall tiling including cement mortar bedding or backing coat, removing rubbish off the premises, removal and depositing where directed and leaving the work clear of any plastering complete all as specified and directed .
M&L Non-skid, coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L Non-skid, coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L Non-skid, coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm cut to size as required as in skirting/dado over and including 10mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B-0 (12.5mm graded stone aggregate) as in sub base of flooring, leveling course of flooring or levelling course of roof etc, finisshed even and rough complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and paving's not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
M&L Plain cement concrete, 1:3:6 type C-1 (using 20 mm graded crushed stone aggregates) as in surface channels or drains etc, complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc, complete all as specified and directed.
M&L 50 mm thick PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate laid in alternative bays area not exc 2 sqm each as in plinth protection laid to slope of 1 in 12 including finishing the surface even & fair & filling the joints (6 mm wide) with mastic filling i.e one part of bitumen 85/25 or VG-30 and 3 parts of sand by weight complete all as specified & directed.
Taking down cement plaster on brick ,PCC block or stone walls or RCC ceiling,etc including raking out joints, hacking for key, scrubbing down with water etc,and removing of rubbish off the premises, leaving the work clear of any plaster complete all as specified and directed.
M&L rendering 15mm thick plaster on stone masonry or other than fair faces of brick work in CM 1:4 finished even and smooth without using extra cement, complete all as specified and directed.
M&L rendering 15mm thick plaster on stone masonry or other than fair faces of brick work in CM 1:6 finished even and smooth without using extra cement, complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of distermper oil emulsion over and including one coat of 2 to 3mm thick wall care putty complete all as specified and directed.
M&L preapration of old surfaces by complete removing existing treatment of walls and applying two coats of distemper oil emulsion over and including one coat of 2 to 3 mm thick wall care putty complete all as specified and directed.
M&L for applying two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489:2004, Alkali & Fungal resistance, dirt esistance exterior paint of required shade (company depot Tinted) with silicon additives @ 1.43 Litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new/old surfeces complete all as specified and directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) n.exc. 1.50 sqm each, and removing from site, complete all as specified and directed.
Taking down chowkats or frames including shutters (w/o taking off shutters from the frames) exc. 1.50 sqm but n.exc. 4 sqm each and removing from site, complete all as specified and directed.
S&F Pressed steel frames of size 165x60mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer, complete all as specified and directed.
S&F pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer, complete all as specified and directed.
S&F mild steel bands,straps,supports or stays for rainwater,ventilating pipes,including bolts,if required; hooks (stay),heavy,for large gates; hook and pintle hinges;large hasps and staples;chains;hand made sliding bolts; clamps; holdfasts;wall ties;hooks for hanging fans;plain angle cleats for securing purlins to wood trusses or rafters;knee piece inserts;two way and three way straps,plate washers ans similar small articles confirming to Fe-290 Gde E-165 complete all as specified and directed..
M&L Plain cement concrete, M-15 (1:2:4 Nominal mix), type B-0 (Using 12.5mm graded crushed stone aggregates) as in filling of steel chowkats or frames, cills and hold fast etc.complete all as specified and as directed.
S&F 35mm thick 2nd class HW (Sal/Hollock) factory made, plain framed, panelled shutters (two panels) 35mm thick with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneers on both faces. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
S&F 2nd class HW (Sal/Hollock) factory made glazed and skeleton shutters 35mm thick, open rebated and prepared to receive glass or gauge, etc. (w/o sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutters S&F to chowkats, complete all as spfd and directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L applying two coats of synthetic enamel paint over one coat of pink primer, on wood and wooden based surfaces of any description , not other wise described, over 10 cm width or girth of any surfaces complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc. 0.50 sqm in each pane, complete all as spfd and directed
S&F 3mm thick figured glass pin head type and glazing with oil putty in squares n.exc. 0.50 sqm in each pane, complete all as spfd and directed
S&F box type steel windows/ventilators comprised of tubular frame and shutters made out of 1.25 mm thick MS tube factory made with double side shutters wire gauged shutters & glass glazed shutter(wire and glass panes shall be measured and paid separately) with side hung shutters with steel handles and steel peg stay doytailed at welded incl 2 Nos tower bolts 150 mm long for each leaf and 8 mm square bar grills at spacing as shown on drg welded to FI frame work,incl other fittings,hinges,handles tarred hold fast PCC blocks etc. complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings etc, with ends of bars shouldered and / or riveted or forged into spikes framed guard bars, barred iron doors, ladders, framed balusters walkways; railings framework of water tanks and similar work conforming to Fe 290 Grade E-165.
S&F stainless steel cold rolled butt hinges, medium weight, 100mm long, complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section, 150mm long complete all as specified and directed.
S&F 150mm long aluminium handle, cast type, anodised complete all as specified and directed.
S&F mild steel sliding door bolts, 300 mm long, plate type, stove enamelled black, with bright bolts not less than 12mm dia with & including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and directed.
S&F 300mm long MS ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each complete all as specified and directed.
S&F 150mm long floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor complete all as specified and directed.
S&F in repairs 25 mm bore drapery rod stainless Steel with brackets Complete all as specified and as directed.
SCHEDULE 'A' PART-II:- Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as directed.
Point wiring for one light point controlled by one way switch with cable of size 1.5sqmm copper conductor cable multi strand PVC insulated FRLS (unsheathed) concealed type, drawing in and including PVC conduit 25mm dia having wall thickness not less than 2mm with sunk cast iron/pressed steel terminal boxes made out of 1.2mm thick sheet including one coat of red oxide primer on internal and external surface including cover plate for required module for mounting switches, sockets, regulators etc controlled by one, one way switch, including 1.5sqmm PVC insulated copper conductor continuous earth wire complete all as specified and directed. Note - (i) wiring shall be done using colour code
All as per the description of Serial item No 66 here-in-before but for 3 pin socket outlet 6 amp independent board complete all as specified and directed.
All as per the description of Serial item No 66 above but for 5 pin switch socket outlet 6 Amp on same board with other switches, complete all as specified and directed.
All as per the description of Serial item No 66 here-in-before but for 3 pin socket outlet 16 amp independent board with cable of size 2.5 sqmm in point wiring and 2.5 sqmm in continuous earth wire complete all as specified and directed.
All as per the description of Serial item No 66 here-in-before but for 3 pin socket outlet 16 amp independent board with cable of size 2.5 sqmm in point wiring and 2.5 sqmm in continuous earth wire in casing caping complete all as specified and directed.
S&F switch piano flush type single pole one way, 6 Amps, complete all as specified and directed.
S&F switch piano flush type single pole one way, 16 Amps, complete all as specified and directed.
S&F socket out let 2 in 1, 3 Pin 6 Amps flush type all as specified and directed.
S&F socket outlet 5 pin, 16 Amp, flush type universal complete all as Specified.
S&F ceiling rose surface type bakelite 50x65 mm two to three terminals all as specified.
S&F sub main wiring with two single core PVC insulated, FRLS unsheathed multi stranded copper conductor cable confirming to IS 694-1990 of size 6 Sqmm (nominal area) and draw in & including PVC conduit of size 25mm dia with all fittings such as Tee, connector pieces, L-junction etc on joints, not less than 2 mm thick and continuous PVC insulated single core copper conductor multi stranded unsheathed 6 Sqmm as earth wire complete including taking down old unserviceable sub main wiring all as specified and as directed. Note:- Two single core cable, one No of earth wire and conduit shall be measured together as one length and making good the disturbed surfaces.
S&F sub main wiring with two single core PVC insulated, FRLS unsheathed multi stranded copper conductor cable confirming to IS 694-1990 of size 4 Sqmm (nominal area) and draw in & including PVC casing caping with all fittings such as Tee, connector pieces, L-junction etc on joints, not less than 2 mm thick and continuous PVC insulated single core copper conductor multi stranded unsheathed 4 Sqmm as earth wire complete including taking down old unserviceable sub main wiring all as specified and as directed. Note:- Two single core cable, one No of earth wire and casing caping shall be measured together as one length and making good the disturbed surfaces.
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
Taking down main switches, distribution board, sheet metal enclosure with MCB's any way and any rating including wooden board or steel board and making good the disturbed surfaces complete all as specified and directed.
S&F factory made epoxy polyester powder coated distribution board TPN, 4 way (TPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 16 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above. Note:- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F sheet metal enclosures distribution board single pole and neutral, 8 way with 200 Amps rated bus bar 240 V, metallic double door IP-42/43 protection complete all as specified and directed.
S&F sheet metal enclosures distribution board triple pole and neutral, 2 way with suitable size of bus bars 415 V, 3 phase, metallic double door IP-42/43 protection complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps, 230 Volts 10 KA, 'C' series complete all as specified and directed.
S&F MCB SPN 32 Amps 10 KA 230 volts 'C' series complete all as specified and directed.
S&F MCB TPN 63 Amps 415 volts AC, C curve complete all as specified and directed .
S&F 20W tube light fitting (batten and LED tube rod), surface and wall mounted LED batten (overall size (1182x23x37) mm with aluminium housing and integrated electronic driver having THD<20% suitable for 20W LED tube rod 4ft long ultra bright LED polycarbonate tubelight with THD<10% with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders (single side connection) complete all as specified and directed. . Make: Havells Cat Part No. for batten LUMILINEPLUSBS20WLED865SPCSS and Cat Part No. for tube rod PHOTONULTRAE 2.01213T8SSTL20WLED865SPC or equivalent make and Cart Part as approved by GE.
Taking down old burnt out bulk head fitting any type and installing new 10W surface mounted LED Bulk Head luminarie with ABS body & polycarbonate diffuser, 6000K, IP54, complete all as specified and directed. Make : Polycab Cat Part No PID0102001 or equivalent in makes as mentioned in Appx 'C'.
Taking down ceiling fan, any size and sweep from its position after disconnecting electrical connection and transport it to workshop for servicing, dismantling for servicing including removal of bearing, bushes, condenser, connector, flaxible cord, split pin etc if required removing old grease and refill fresh, lubricating bushes alongwith new washers, cleaning and washing fan blades, fan body etc with soap solution after repairing re- assamble the same and transporting from workshop to any location in Alhilal Mil Station and fixing to position/ location as directed by Engineer-in-charge, connecting to electric system, testing etc complete all as specified and directed. Note: -(i) Replacement of parts/rewinding shell be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of transporting fan from any location in Army Area to MES store & taking down unserviceable/ defective parts. (iii) Item such as bearings, bushes, capacitor, shaft etc required for replacemen shalled be measured and paid seperately as supply only.
Supply only ball bearing suitable for ceiling fan of any sweep complete all as specified and directed.
Supply only gun metal bush suitable for ceiling fan of any sweep complete all as specified and directed.
Supply only capacitor 2.5 mfd suitable for ceiling fan 1200/1400 mm sweep complete all as specified and directed.
S&F in repairs capacitor 2.5 mfd suitable for ceiling fan 1200/1400 mm sweep complete all as specified and directed.
M&L cutting and taking out old burnout winding ceiling fan of any sweep and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete to entire satisfaction of Engineer-in-charge.
S&F fan hook made out of MS flat iron of size 50mm x 6mm suitable for 15mm bore pipe including suitable size of nut, bolt & washer complete all as specified and directed.
Material and labour spray painting of ceiling fan, fan blades, down rod, canopy etc with a coat of synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the MES fan numbers in block letter of dimension 15mm x 20mm size etc with black paint complete all as directed.
M&L for earthing with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground (earth pit less than 2.25 mtr deep below normal ground level) with top edge of the earth plate not less than 1.5 mtr deep below normal ground level, connected to 4mm dia galvanized iron wire as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia light grade protection pipe, 20mm dia GI light grade watering pipe with funnel including char coal dust, salt, PCC 1:2:4 in pit with precast RCC M-15 cover reinforced with XPM not less then 4.00 Kg per sqm including necessary earth work in any type of soil, removal of surplus soil to a distance not exc 50m, returning filling in complete as shown in electrical plate No 3 of SSR Part-I (2009), and connected to earthing test point all as specified or indicated, testing on completion including taking down old unserviceable earthing complete all as specified and directed. Note:- The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length.
S&F earth continuity conductor 4mm dia galvanised iron or steel wire or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
Supply, laying commissioning & testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with multi stranded aluminium conductor of size 25 sq.mm, 4 core complete all as specified and directed. Note:- Earth work, sand cushioning & bricks shall be measured and paid separately.
S&F 40mm bore galvanized iron tubing, light grade including all fitting for cable protection elc laid in floor, trenches or fixed to poles with clamps etc complete all as specified and as directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep in any type of soil for laying cables, foundation of poles etc. and getting out complete all as specified and as directed.
Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exc. 25cm, complete all as specifed and as directed.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as directed.
M&L sand cushioning to under ground cable with a layer of sand 8cm before laying the cable and 15cm after laying the cable (10cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
M&L sub class 'B' brick, old size as cable protection cover, laid dry, flat, transversally along the length of cable on sand cushioning with width equal to the length of the brick, complete all as specified and directed.
S&F GI tubing (ISI marked) 15mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors (concealed tubing) complete all as specified and directed. Note:- The cost for cutting chases in walls,floors,etc and their making good for concealed pipe work included in this item.
S&F cutting existing steel tubing 15/20mm bore for alterations or additions (Each cut measured) complete all as specified and directed.
S&F 15mm bore stop valves/angle cock (two way if required), cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union, fixed in repair, complete all as specified and directed.
S&F fancy type, chromium plated, bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15 mm bore iron pipe or for brass ferrule complete all as specified and directed.
S&F PVC connection for hot/cold water made of double layer nylon braided and fabric at a pressure of 6 Kg/Sq cm at both ends, 450mm long, heavy duty with CP brass adopters, washers suitable for 15mm bore pipe complete all as specified and directed.
S&F new electric water storage Heater (vertical type Geysers) 25 Ltrs BEE RATING 5 STAR, 230 volts AC single phase with and including grouting with high tensile rag bolt, nut & washer etc as directed as per site requirement and making necessary inlet /outlet water connection for Geysers. Geysers to have glass lines tank, fero glass coated container, PUF insulation, glass coated heating element, 8 BAR rated pressure, thermostat cut off etc.complete all as specified and as directed. Make:- Bajaj (Model No-Caldia)/ Crompton (SWH Arno Neo ASHW-2125)/ Havells (Puro project Model PURO PPT) and equivalent make as approved by GE.
M/S SAI ENGINEER
M/S THAKUR ENTERPRISES
BHARDWAJ BUILDERS
VIVEKA ENTERPRISES
M/s. RAMESH KUMAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .