Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-AOC SARJU VILLA 5A KHALISA KOTA PALLY KOLKATA 700051 | KOLKATA | KOLKATA | WEST BENGAL | 700051 | ₹3.1 L | L1 | Accepted-AOC lowest bidder |
| 2 | L2₹3.2 L+₹2,085.65 (0.67%)Rejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 UDYAM WB 23 0013338 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | ₹3.2 L+₹2,085.65 (0.67%) | L2 | Rejected-Finance higher than L1 |
| 3 | L3₹3.2 L+₹2,681.55 (0.86%)Rejected-Finance 7G CORNFIELD ROAD KOLKATA 700019 | KOLKATA | KOLKATA | WEST BENGAL | 700019 | ₹3.2 L+₹2,681.55 (0.86%) | L3 | Rejected-Finance higher than L1 |
| Sl No | Description | Qty | Unit | DEY ENTERPRISE L2 | CONCORD ENGINEERING L3 | System Advance Technologies (P) Ltd. L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, delivery of 6 Core Armor Optical Fiber Cable as per specification below :
i) Fiber / Tube identification: Color coded
Central Strength: Member: Glass rein forced plastic (GRP)
Fiber Protection (Tube): Polybutylene Terephthalate (PBT)
Fillers: As required
Water Blocking: Thixotropic Gel (Tubes)/ Petroleum Jelly (Interstices)
Core Wrapping: Polybutylene Terephthalate Tape
Sheath: Polyethylene (UV Stabilised)
Jacket: Nylon (UV Stabilised)
Fiber Count (up to): 6
Tube Diameter (mm): 2
Nominal Diameter (mm): 9.6
Nominal Weight (Kg/km): 70
Maximum Tension (kN) Installation: 2.3, In Service: 1.3
Maximum Crush Resistance (kN/100mm): 1.6
Minimum Bend Radius (mm) Under Load: 20 x OD
Storage Temperature: -40°C to +70°C
Operating Temperature: -40°C to +70°C
Attenuation (dB/km) (max) @1310/1383/1550nm (typical): 0.34/0.31/0.21
Zero dispersion Wavelength: 1302-1322mm
Slope@ Zero Dispersion Wavelength (ps/nm².km): 0.090
PMD (ps/√km): 0.1
MFD @ 1310nm: 9.2 ± 0.4mm
Cladding diameter (mm): 125 ± 0.7
Fiber Coating Diameter (mm): 250 ± 10
[Make : Molex / Legrands / Lapp Kable] | 500 | MTR. | 50.5 ₹25,250 Lowest | 52 ₹26,000 | 51 ₹25,500 |
| 2.00 | Supply and delivery of 1.5 sq.mm 3 core Copper Conductor Armored LT cable as per following specification:
Conductor Material : Multistrand Copper Conductor
No of Core : 3 Core
Voltage Rating : 1100V
MOC: Copper Cables, XLPE Insulated, 1100V grade as per IS 7098 (Part 1)2011
[Make : Any Approved make] | 500 | MTR. | 196 ₹98,000 | 194 ₹97,000 Lowest | 195 ₹97,500 |
| 3.00 | Supply and delivery of 40mm OD HDPE Pipe :
Size : 40 /33 mm OD/ID
Standards IS 4984:2016
Standards As per TEC Certification
Length Available in Coils & Drums
Material Grades : PE-100 In Different Colors
Applications: Optical Fiber Cable (OFC) Ducting for Telecom & Data Networks
Color Black with Blue stripes
[Make : Any Approved make] | 500 | MTR. | 141 ₹70,500 | 141.5 ₹70,750 | 139 ₹69,500 Lowest |
| 4.00 | Repairing of Local Area Networking by laying HDPE Pipe at damaged installation area from nearest pith to pith, pulling of OFC and Power cable through HDPE Pipe from Clear Water pump house to Filter bed pump huse and Raw water pump house and commissioning of 6core Optical Fiber by Splicing with Molex SM Pigtail. The OTDR Testing will be done at the time of commissioning to check the Link quality. The OTDR Report to be submitted after complete commissioning of Link. The UPS power cable also pulled through same pipe and terminated at Wall Mount Network Panel.
Finally vendor will be responsible to completely up the repair Link with the existing running Link and check the packet drop at specified Load. | 500 | MTR. | 142 ₹71,000 | 143 ₹71,500 | 141 ₹70,500 Lowest |
| 5.00 | GST @18% | 1 | ITEM | 47,655 ₹47,655 | 47,340 ₹47,745 | 47,340 ₹47,340 Lowest |
| 6.00 | CESS @1% | 1 | ITEM | 3,124.05 ₹3,124.05 | 3,103.4 ₹3,129.95 | 3,103.4 ₹3,103.4 Lowest |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
3 Aug 2026, 10:00 amClosed
Executive_Engineer_NTKMD_PHED
Utility_Bldg__Beside_Delhi_Public_School_AA_ID_New_Town_Kol_700156
Replacement of damaged SCADA Cable at WTP, AA-I at New Town under NTK Project.
2026_PHED_1033600_21
PHE/NTKMD/e-12 of 2026-27
Open Tender
Project Work
Item Wise
30 days
WORK
Please refer Tender documents.
6 documents required · 6 mandatory
₹7,000
9 Sept 2026
23 Jul 2026
5 Aug 2026
23 Jul 2026
3 Aug 2026
23 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, delivery of 6 Core Armor Optical Fiber Cable as per specification below :
i) Fiber / Tube identification: Color coded
Central Strength: Member: Glass rein forced plastic (GRP)
Fiber Protection (Tube): Polybutylene Terephthalate (PBT)
Fillers: As required
Water Blocking: Thixotropic Gel (Tubes)/ Petroleum Jelly (Interstices)
Core Wrapping: Polybutylene Terephthalate Tape
Sheath: Polyethylene (UV Stabilised)
Jacket: Nylon (UV Stabilised)
Fiber Count (up to): 6
Tube Diameter (mm): 2
Nominal Diameter (mm): 9.6
Nominal Weight (Kg/km): 70
Maximum Tension (kN) Installation: 2.3, In Service: 1.3
Maximum Crush Resistance (kN/100mm): 1.6
Minimum Bend Radius (mm) Under Load: 20 x OD
Storage Temperature: -40°C to +70°C
Operating Temperature: -40°C to +70°C
Attenuation (dB/km) (max) @1310/1383/1550nm (typical): 0.34/0.31/0.21
Zero dispersion Wavelength: 1302-1322mm
Slope@ Zero Dispersion Wavelength (ps/nm².km): 0.090
PMD (ps/√km): 0.1
MFD @ 1310nm: 9.2 ± 0.4mm
Cladding diameter (mm): 125 ± 0.7
Fiber Coating Diameter (mm): 250 ± 10
[Make : Molex / Legrands / Lapp Kable] | - | MTR. | 103 | - |
| 2 | Supply and delivery of 1.5 sq.mm 3 core Copper Conductor Armored LT cable as per following specification:
Conductor Material : Multistrand Copper Conductor
No of Core : 3 Core
Voltage Rating : 1100V
MOC: Copper Cables, XLPE Insulated, 1100V grade as per IS 7098 (Part 1)2011
[Make : Any Approved make] | - | MTR. | 103 | - |
| 3 | Supply and delivery of 40mm OD HDPE Pipe :
Size : 40 /33 mm OD/ID
Standards IS 4984:2016
Standards As per TEC Certification
Length Available in Coils & Drums
Material Grades : PE-100 In Different Colors
Applications: Optical Fiber Cable (OFC) Ducting for Telecom & Data Networks
Color Black with Blue stripes
[Make : Any Approved make] | - | MTR. | 103 | - |
| 4 | Repairing of Local Area Networking by laying HDPE Pipe at damaged installation area from nearest pith to pith, pulling of OFC and Power cable through HDPE Pipe from Clear Water pump house to Filter bed pump huse and Raw water pump house and commissioning of 6core Optical Fiber by Splicing with Molex SM Pigtail. The OTDR Testing will be done at the time of commissioning to check the Link quality. The OTDR Report to be submitted after complete commissioning of Link. The UPS power cable also pulled through same pipe and terminated at Wall Mount Network Panel.
Finally vendor will be responsible to completely up the repair Link with the existing running Link and check the packet drop at specified Load. | - | MTR. | 103 | - |
| 5 | GST @18% | - | ITEM | 101 | - |
| 6 | CESS @1% | - | ITEM | 101 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
Tendernotice_2.pdf
PDF • 0.90 MB
Tendernotice_3.pdf
PDF • 3.12 MB
Tendernotice_4.pdf
PDF • 0.56 MB
Tendernotice_5.pdf
PDF • 0.04 MB
BOQ_2538613.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .