| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹62.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹66.4 L+₹4.2 L (6.75%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹66.6 L+₹4.4 L (7.10%)Rejected-Finance PERUMKUNNAPALA HOUSE NELLIPARAMBA KUTTIYERI 670141 | KUTTIYERI | KANNUR | KERALA | 670141 | L3 | Rejected-Finance L3 | |
| 4 | L4₹67.3 L+₹5.0 L (8.08%)Rejected-Finance KOYADAN CHOYIKUNIMAL MULLAKODI PO MAYYIL KANNUR PIN 670602 | MAYYIL | KANNUR | KERALA | 670602 | L4 | Rejected-Finance L4 | |
| 5 | L5₹69.0 L+₹6.8 L (10.9%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹83.0 L
EMD Value
₹50,000
Closing Date
4 Sept 2024, 5:00 pmClosed
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER PWD BUILDINGS DIVISON, THALASSERY
GENERAL Mavicheri LP School Annual Plan 2023 24 Construction of School Building for Govt L P School Mavicheri, Kannur Phase1 General Civil Work
2024_PWD_687706_1
12/2024-25
Open Tender
Civil Works - Buildings
Item Rate
365 days
Mavicheri
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹50,000
Yes
21 Dec 2024
24 Aug 2024
7 Sept 2024
24 Aug 2024
4 Sept 2024
24 Aug 2024
Amount
Estimate
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
OD145081/2023-2024:Laterate masonry with neatly dressed laterate stone of size 35 x20x20 or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
2.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
OD145082/2023-2024:Providing and laying in position machine bathched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended propoortions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @330kg/m3.Excess cement used as per design mix is not payable or less usage of cement content is recoverable separately- All work upto plinth level
OD145083/2023-2024:Providing and laying in position machine bathched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended propoortions as per IS : 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @330kg/m3.Excess cement used as per design mix is not payable or less usage of cement content is recoverable separately- All work above plinth level
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
OD145084/2023-2024:Laterate masonry with neatly dressed laterate stone of size 35x20x20cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour char
10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
PRANAV T P
P PRABHAKARAN
Soman nambiar
NAMBIAR CONSTRUCTIONS
M.T MUHAMMED MUNAZIR
SUJITH AK
AMEER CA
Bidder Name
M.T MUHAMMED MUNAZIR
P PRABHAKARAN
Soman nambiar
HUSSANKUNHI M
SUJITH AK
PRANAV T P
NAMBIAR CONSTRUCTIONS
AMEER CA
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1070108.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .