Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.5 LAccepted-AOC | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND BEING L1 BIDDER | |
| 2 | L2₹82.8 L+₹14.0 L (20.3%)Rejected-Finance GOKUL APARTMENT PANJABIPARA DISTT JALPAIGURI SILIGURI 734401 WB | DARJEELING | WEST BENGAL | 734401 | L2 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER | |
| 3 | L3₹86.6 L+₹17.7 L (25.8%)Rejected-Finance OLD HASIMARA DISTT JALPAIGURI WEST BENGAL PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L3 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
Tender Value
₹88 L
EMD Value
₹1.6 L
Closing Date
10 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE BINNAGURI
HQ CWE BINNAGURI, BINNAGURI CANTT, JALPAIGURI, WEST BENGAL, PIN-735232
SPL REPAIRS TO BLDG NO P-70 AND P-114 AT JAIGAON UNDER GE SOUTH BINNAGURI
2024_MES_672096_1
8169/E8
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH BINNAGURI
AS PER NIT
8 documents required · 8 mandatory
₹1,000
GE (S) BINNAGURI
₹1.6 L
Yes
29 Nov 2024
5 Sept 2024
11 Oct 2024
5 Sept 2024
10 Oct 2024
26 Sept 2024
Amount
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as per specified and as directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/Slabs/blankets of any thickness including cover fillets, complete all as specified and as directed by Engineer-in-charge.
Dismantling framed timber scantlings 40 Sqcm and over in section and in any position, complete all as specified and as directed by Engineer-in-charge.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm each and removing from site, complete all as specified and as directed by Engineer-in-charge.
Demolition of Reinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
M&L Precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregates) set in cement mortar 1:4 as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary formwork, complete all as specified and as directed by Engineer-in-charge.
M&L for Mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for Mild steel TMT bars 6 to 8 mm dia. cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick wall of any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 20 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 with including mixing WPC as per manufacturer's instructions and surface even & smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. (Note: WPC shall be measured and paid separately as supply only under relevent item of this schedule)
Supply only integral water proofing compound confirming to IS complete all as per specified and as directed by Engineer-in-charge.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 including, surface even & smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for 5 mm thick rendering plastering on fair faces of brick work or concrete surface in cement mortar (1:6) and surface even and fair without using extra cement, complete all as specified and as directed by Engineer-in-charge.
S&F MS steel work in tubular trusses including special shaped washers etc., complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 graded St 240 including steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as per specified and as directed by Engineer-in-charge.
S&F of Rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) and similar work conforming to Fe.410 -W Gde-E-250 quality A complete all as per specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F of Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F of Anodised aluminium snap grid frame work with size of grid 605 mm X 605 mm for false ceiling, complete all as specified and as directed by Engineer-in-charge.
M&L for 4mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping, complete all as per specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
M&L for 100 mm thick for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) as in floor finished even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge.
S&F of coloured non-skid ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge.
S&F of coloured non-skid ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 10 mm thick screed bed or bedding layers in CM 1:4 complete all as per specified and as directed by Engineer-in-charge.
M&L for coloured glazed ceramic tiles 350x 250x 7 mm/ 450X 350X 7mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over 10 mm thick screed bed or bedding layers in CM 1:4 complete all as per specified and as directed by Engineer-in-charge.
M&L for Double nosing and stepping stone 15 mm thick of colour as approved as in treads of stair case set and jointed in neat cement slurry over and including 10 mm thick screed bed for laying floor finishes in cement mortar 1:4, complete all as specified and as directed by Engineer-in-charge.
M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete with 15 mm thick screed bed or bedding layer of cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
S&F of Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as per specified and as directed by Engineer-in-charge.
M&L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work, complete all as per specified and as directed by Engineer-in-charge.
S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as per specified and as directed by Engineer-in-charge.
M&L for 35 mm thick second class hardwood glazed and skeleton shutter open rebated and prepared to receive glass, gauge etc (without sash bar) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of member (Bottom 250mm, stiles 100mm, top 120mm & lock rail 160mm wide) as specified in SSR part I section & clause 8.24 (a) complete all as specified and as directed by Engineer-in-charge.
S&F of floor door stopper 14cm long of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as per specified and as directed by Engineer-in-charge.
S & F Stainless steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned stacks, or galvanized wire staples complete all as per specified and as directed by Engineer-in-charge.
S&F of 150 mm mild steel tower bolts stove enamelled black with bright, complete all as per specified and as directed by Engineer-in-charge.
S&F 250 mm long mild steel sliding door bolts plate type stove anamelled black with bright bolts not less than 12mm dia with including a minimum of 6 bolts nut four on bolts plate & two on staple plate, complete all as per specified and as directed by Engineer-in-charge.
S&F of 150 mm long aluminium handles, cast type, anodised, complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. .frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as per specified and as directed by Engineer-in-charge.
S&F Powder coated aluminium window sliding type three track (2 glazed & one gauzed shutter ) aluminium sections weighing not less than 1.67kg/m for frame and 0.55 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing , screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window and making good disturbed surfaces of wall complete all as per specified and as directed by Engineer-in-charge.
S&F Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazing cleats, rubber packing , anodised aluminium snap beading,screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangements including taking down of old existing steel ventilator and making good disturbed surfaces of wall complete all as per specified and as directed by Engineer-in-charge.
Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 7mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) (A) Area not exceeding 2.00 sqm each
M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide, primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for applying two coats acrylic-based distemper of shade as approved by GE over a coat of primer over one coats of wall care putty (1mm each) on wall, complete all as specified and as directed by Engineer-in-charge. and as per the manufacturer's instructions. Note: 1. Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions.
M&L for preparing new plastered surfaces and applying two coats of cement based paint, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge.
M&L for complete removal of existing treatment from wall surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down with water and applying applying one coats of white wash to ceiling complete all as specified and as directed by Engineer-in-charge.
M&L for complete removal of existing treatment from wall surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down with water and applying one coat of distemper oil emulsion complete all as specified and as directed by Engineer-in-charge.
M&L for complete removal of existing treatment from wall surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down with water and applying one coat of cement base paint complete all as specified and as directed by Engineer-in-charge.
M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded aggregate) as in flooring, plinth protection/foothpath finishing cement concrete surface even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick set jointed and pointed in with grey cement and no pigment laid over floor and pointed in neat cement slurry in floors including 15 mm thick screed in CM (1:6), complete all as specified and as directed by Engineer-in-charge.
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as per specified and as directed by Engineer-in-charge.
M&L for brick work with sub-class `B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
M&L for 40 mm thick PCC 1:2:4, type B0 (using 12.5 mm graded stone agg) for DPC to horizotal or vertical surfaces including necessary form work including applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. m. per sq. m complete all as specified and as directed by Engineer-in-charge.
M&L for formwork to chullah hoods, chajjas, weather shades, corbels, water troughs and similar items including edges fair finished surface of concrete flat complete all as specified and as directed by Engineer-in-charge.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished surfaces of concrete flat etc., complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of 0.63 mm thick plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed), complete all as per specified and as directed by Engineer-in-charge.
Roughening the surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust and brushing neat cement slurry with 3.0 kg of cement per Sqm, complete all as specified and directed by Engineer-in-Charge.
Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exceeding 500 m and not exc. 900 m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc, complete all as specified and as directed by Engineer-in-charge.
M&L for 10 mm screed bed over 25 mm PCC 1:2:4 type B-2 (using 40mm grade crushed stone aggregate)bendding layers in cement mortar (1:4) as in order to maintain proper slope over existing roof surface for applying single component acrylic polymer modified, finishing surface even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. Note:- Polymeric membrane shall be measured and paid separately under relevant item of this schedule.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application, complete all as specified and as directed by Engineer-in-charge. Note:- (i) Laying APP based polymeric membrance shall be done by torch on method or as per manufacturers instructions. (ii) A minimum overlap of 100 mm shall be made at the end and 75 mm shall be made at the polymeric membrance respectively and sealed all overlaps and joints as per manufacturers instructions.
M&L for 25 mm thick PCC (1:2:4) type B-0 (12.50 mm graded stone aggregate) , as in under layer levelling course for Bath, WC floor below tiles finished even and rough, complete all as specified and as directed by Engineer-in-charge.
M&L for forming 12 mm thick expansion joints for 100mm thick concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’, complete all as specified and as directed by Engineer-in-charge.
Dismantling of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, approaches, dado/Partitions etc, complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches n exc 1.5m wide and n. exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n. exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed by Engineer-in-charge.
M&L for fly ash brick work with Modular bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-charge.
M&L for RCC type B-0, 1:2:4 (12.5 mm graded aggregate) as in chajjas, beam, landing, shelf, platform, facia and like, complete all as per specified and as directed by Engineer-in-charge.
M&L for RCC 1:2:4, type B1 (20mm graded stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as per specified and as directed by Engineer-in-charge.
M&L for plain cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in surface channels and drains, complete all as specified and as directed by Engineer-in-charge.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided for, complete all as specified and as directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed by Engineer-in-charge.
S&F of for 125 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws, complete all as per specified and as directed by Engineer-in-charge.
S&F of 125 mm long aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F 100 mm long aluminium handles, cast type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S&F of PVC (SWR) 75 mm bore bends with access door complete all as per specified and as directed by Engineer-in-charge.
S&F of 110 mm dia bore PVC (SWR) bends, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of vitreous china squatting pan "Orissa" pattern size 580x440mm white with integral foot rests(excluding flushing cistern and flush pipe) with 'P' or 'S" trap from or back inlet etc including connection to trap and flushing pipe and provision of lime concrete bedding, complete all as per specified and as directed by Engineer-in-charge.
S&F of Vitreous China wash down water closet pan (pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc., complete all as per specified and as directed by Engineer-in-charge.
S & F PVC valveless, syphonic action type 10 ltr capacity low level flushing cistern, white, with inlet, ball valve, float and handle including brackets and 32 mm bore PVC flush pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F of PVC connection 15mm dia with PTMT nuts of length 450mm, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of sinks made of stainless steel 0.80mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm etc., complete all as specified and as directed by Engineer-in-charge.
S&F in repair of Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets and including, waste pipe, CP waste coupling etc., complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of 32 mm bore Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of central hole basin mixture for WHB, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of plastic water closet seat cover, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of Bib taps fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of stop valves fancy type cast copper alloy, chromium plated with long shank and cup (concealed type) for 15mm bore pipe, screwed both ends including necessary fittings such as sockets for pipe or for union, complete all as per specified and as directed by Engineer-in-charge.
S&F of pillar taps 15mm fancy type, bore cast copper alloy with capstan heads chromium plated screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of tubular towel rail 20mm dia type brass chromium plated 600mm long between flanges, complete all as specified and as directed by Engineer-in-charge.
Dismantling water tanks of capacity exc. 500 and not exc. 1000 ltrs, complete all as per specified and as directed by Engineer-in-charge.
S&F of rotational moulded PVC water storage tank 1000 litres capacity conforming to IS-12701(1989) cylindrical vertical type multi-layered with closed top including inlet, outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part-I, 2009 etc., complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron pipe 15 mm bore and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of 15 mm bore angle cock CP with flange complete all as per specified and as directed by Engineer-in-charge.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as per specified and as directed by Engineer-in-charge.
S&F of PVC cabinet with mirror good quality, complete all as specified and as directed by Engineer-in-charge.
S&F in repair of Soap dish, vitreous China white, approximate size 160x 160x90 mm, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of 1.00 mm thick stainless steel plate rack of size 31"x30"x10", complete all as per specified and as directed by Engineer-in-charge.
S&F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union, complete all as per specified and as directed by Engineer-in-charge.
S&F of 110mm dia PVC (SWR) branch piece single (single 'Y') equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge.
S&F of 110mm dia PVC SWR vent cowl complete all as per specified and as directed by Engineer-in-charge.
S&F of 75 mm bore PVC (SWR) junction single (Single `T') equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge.
S & F 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of 75mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as per specified and as directed by Engineer-in-charge.
M&L for salt-glazed stoneware gully traps, square or round mouthed, type `P' 150x100mm, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of 20 mm ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/ 20 mm - 210gms/25mm-455gms/ 40mm - 690 gms) and fixed in position complete all as per specified and as directed by Engineer-in-charge.
S&F of Gun-metal 20 mm bore pipe, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as per specified and as directed by Engineer-in-charge.
M&L Cutting existing steel tubing 40 or 50 mm bore for alterations or additions (Each cut measured)complete all as per specified and as directed by Engineer-in-charge.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for pipe of internal dia. 150mm, complete all as specified and as directed by Engineer-in-Charge.
M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as per specified and as directed by Engineer-in-charge.
S&F of Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. confirming to Fe 410 -W (GdeE- 250) quality A, complete all as specified and as directed by Engineer-in-charge. confirming to Fe 410 -W (GdeE- 250) quality A
Supply & Laying Sub-Class B, old size Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
M&L for cutting holes into or through brick walls built in in brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete, superficial area n exc 150 sqcm, complete all as per specified and as directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and as directed by Engineer-in-charge.
S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 20 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge.
S&F of GI tube 15 mm bore medium grade with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engineer-in-charge.
Supply and laying GI tube 20 mm bore medium grade with fittings and fixed in trenches complete all as specified and as directed by Engineer-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as per specified and as directed by Engineer-in-charge.
S&F of 75 mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F of 110 mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F in repair of harrison rails curtain rod, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as per specified and as directed by Engineer-in-charge.
Demolition and breaking up including removing salt glazed stoneware pipe 150 mm bore (internal) with concrete bedding and haunching complete including necessary earth work as required complete all as specified and as directed by Engineer-in-charge.
S&F in repair of 40 mm High density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm fixed to walls, ceilings or in floors etc. complete all as per specified and as directed by Engineer-in-charge.
Use and waste of formwork to edges of rough finished surfaces of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as per specified and as directed by Engineer-in-charge.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as per specified and as directed by Engineer-in-charge.
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight), complete all as specified and as directed by Engineer-in-charge.
Taking up or down of 40 mm bore steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge.
Taking up or down of 25 mm steel tubing and connections, including cleaning for refixing or removal to store, complete all as per specified and as directed by Engineer-in-charge.
Supply and laying of GI tube 40 mm bore medium grade with all fittings and fixed in trenches complete all as specified and as directed by Engineer-in-charge.
Supply and laying of GI tube 25 mm bore medium grade with all fittings and fixed in trenches complete all as specified and as directed by Engineer-in-charge.
S&F GI tubing 40 mm bore light grade ISI marked for protection of cable including necessary joints with all fitting, laid in trenches, complete all as specified and as directed by Engineer-in-charge.
M&L for concrete bed to 150 mm dia drain pipes including packing under & haunching against the sides of pipes with concrete after they are laid & tested in PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) complete all as per specified and as directed by Engineer-in-charge.
M&L for 150 mm dia (internal) salt glazed stone ware drain pipes (Grade A) ISI Marked as in sewage lines laid in trenches and jointed complete all as specified and as directed by Engineer-in-charge
Taking down carefully old unserviceable copper/ aluminium point wiring (light, exhaust fan, socket or power) complete incl fittings such as switches, ceiling roses, pendants, regulators, bells, sockets, tube light fittings etc., and making good disturbed surface of walls & floors etc., complete all as specified and as directed by Engineer-in-charge.
M&L for concealed point wiring with two single core PVC insulated, unsheathed, multistranded copper conductor FRLS of size 1.5 Sq. mm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 Sq. mm green in colour as earth lead in and including PVC rigid conduit (medium grade) with all fittings & accessories for mounting modular switch, sockets, fan regulators etc. for one light, complete all as specified and as directed by Engineer-in-charge. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the quoted rates. Modular fitting will be paid & measured under relevant items separately.
All as per serial item No. 144 above but for one light point controlled by two way switch, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 144 above but for one fan point controlled by one switch, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 144 above but for socket outlet 5/6 AMPs point on same board, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 144 above but for socket outlet 5/6 AMPs point on independent board, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 144 above but for One bell/ buzzer point controlled by one push button, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 144 here in before but wiring with single core, multistranded copper conductor of size 2.5 sqmm for socket out let point on independent board, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular Switch single pole, one way, 6 Amps, 1 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular switch 2 way 6A, 1 module, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular shutter socket outlet 5 pin, 6 Amps, 2 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular shutter socket 6A/16A - 2/3 pin combined 2 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular Switch single pole, one way, 16 Amps, 1 module, 230 volts, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular Bell push 6 Amp, 1 Module, 230 volt, ISI marked, complete all as specified and as directed by Engineer-in-charge.
S&F of Buzzer, Ding Dong AC 230 volts, single pole, complete all as specified and as directed by Engineer-in-charge.
S&F of modular Metal flush box 1/2 module, complete all as specified and as directed by Engineer-in-charge.
S&F of modular Metal flush box 3 module, complete all as specified and as directed by Engineer-in-charge.
S&F of modular Metal flush box 6/8 module, complete all as specified and as directed by Engineer-in-charge.
S&F of modular white cover plate with frame 1 module inclusive of inner & outer plate, complete all as specified and as directed by Engineer-in-charge.
S&F of modular white cover plate with frame 3 module inclusive of inner & outer plate, complete all as specified and as directed by Engineer-in-charge.
S&F of modular white cover plate with frame 6/8 module inclusive of inner & outer plate, complete all as specified and as directed by Engineer-in-charge.
Supply and of fix ceiling rose surface PVC three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F of modular electronic step regulator (speed regulation in 5 steps) 120W - 2 module suitable for ceiling fan 1200 sweep/1400 mm, complete all as specified and as directed by Engineer-in-charge.
Supply and fix of LED tube light fittings1 x 20 Watt, 220 V, AC decorative box type with driver holder including LED tube rodconnecting up with three core flexible copper conductor cable from ceiling rose to tube light fitting including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB TP & N 4 way double door DB, 415 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 8 way double door DB, 240 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of 415V 10KA 'C' curve miniature circuit breaker (MCB) of Triple pole & neutral (TPN) 40 To 100 Amps and current carrying capacity in the DB complete with connection testing and commissioning including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SP and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing and taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
M&L for sub main wiring two run of size 6 sqmm PVC insulated, ISI marked, FRLSH unsheathed, electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 6.0 sqmm PVC insulated stranded copper conductor earth wire in PVC conduit of suitable size (two run of 6 sqmm cable and one of 6.0 sqmm wire and one run of PVC conduit will be measured as one unit)including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge.
S&F of street light bracket made out of GI tubing 25 mm bore medium grade 1.20 Mtr long bend to required shape as in bracket for street light fittings fixed with two No of MS flat iron 25mm x 5mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for building security light including painting of mild steel flat iron surfaces with two coats of synthetic enamel paint over a coat of red oxide primer including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
S&F XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100Volt grade on walls with fixing acessories of size 16 Sqmm 4 Core cable including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and as directed by Engineer-in-charge.
Supply and fix of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm, complete all as specified and as directed by Engineer-in-charge.
S&F of exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed by Engineer-in-charge.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
ANIL ENGINEERING CO (BID ID -3126276)
DEEP NIRMAN (BID ID -3124965)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .