MAINT AND REPAIRS TO INTERNAL WIRING, FITTINGS AND FIXTURES IN DOMESTIC AREA AT AFS BIDAR
2019_MES_305436_1
8196/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Bidar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Bidar
₹39,960
Yes
5 Mar 2020
10 Dec 2019
9 Jan 2020
10 Dec 2019
8 Jan 2020
25 Dec 2019
Amount
Taking down existing unserviceable fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings, regulators, etc. carefully by unscrewing from boards/ outlet boxes, and making good disturbed surface to match with existing finish all as directed.
S & F Switch piano flush, single pole, one way, 5/6 Amp, all as specified and directed.
S & F Ceiling rose surfaces bakelite 63.5 X 28mm three terminals all as specified and directed.
S & F switch socket outlet 3 Pin 5 Amp, flush type, all as specified and directed.
S & F switch socket outlet multipurpose, 3 Pin 15/16 and 3pin 5/6Amp, 240 Volt, controlled by one switch all as specified and directed.
S & F switch bell push piano, flush, single pole, 5/6 Amp, all as specified and directed.
S & F switch modular type single pole one way 6 Amp with all accessories all as specified and directed.
S & F switch modular type single pole one way 16 Amp with all accessories all as specified and directed.
S & F socket outlet 3 Pin 6 Amp modular type all accessories all as specified and directed.
S&F socket outlet multipurpose 3 Pin 16A modular type with all accessories all as specified and directed.
S&F Bell push modular type 6A with all accessories all as specified and directed.
S & F 240V, 20 Amp single pole and earth enclosure with a two pin and earth plug and socket complete including taking down existing all as specified and directed.
S & F RCBO 30 ma, having current carrying capacity 40 Amp, SPN including taking down existing all as specified and directed.
S & F MCB DB SPN 4 way, double door, including taking down existing all as specified and directed.
S & F MCB DB SPN 8 way, double door, including taking down existing all as specified and directed.
S & F MCB DB TPN 4 way, single door, including taking down existing all as specified and directed.
S & F MCB TPN 40 to 63 Amp 240 V 50 Hz AC Supply including taking down existing all as specified and directed.
S & F MCB TPN 6 to 32 Amp with proper size lugs aincluding taking down existing all as specified and directed.
S & F MCB SP 6 to 32 Amp including taking down existing all as specified and directed.
S & F MCB SPN 10 to 32 Amp 240 V 50 Hz AC Supply including taking down existing all as specified and directed.
S & F MCB SPN 40 to 63 Amp 240 V 50 Hz AC Supply including taking down existing all as specified and directed.
S & F electronic driver suitable for LED fittings of any type / make/ model of 20 to 45W capacity of luminaries including taking down existing all as specified and directed.
S & F electronic driver suitable for LED fittings of any type / make/ model of 9 to 19 W capacity of luminaries including taking down existing all as specified and directed.
S & F bell AC 230 Volt Ding Dong type, 240 Volt AC supply, including taking down existing all as specified and directed.
S & F new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium bldg security light luminaries with high power LED as light source of power 45 W, IP 66, system luminous efficacy >85 Lm/ W, life 50,000 hrs, surge protection 10 kV and zero maintenance including all light fittings etc. and connection from ceiling rose to light fitting by using three core 1.5 sq mm copper conductor cable complete including taking down existing all as specified and directed.
S & F MCCB 125 Amp 4 pole 25 KA in existing panel board connecting with proper size link set, incoming, out going cable electrically connected and making necessary modification in existing panel as required at site complete including taking down existing all as specified and directed.
S & F MCCB 100 Amp 4 pole 25 KA in existing panel board connecting with proper size link set, incoming, out going cable electrically connected and making necessary modification in existing panel as required at site complete including taking down existing all as specified and directed.
S & F MCCB 63 Amp 4 pole 16 KA in existing panel board connecting with proper size link set, incoming, out going cable electrically connected and making necessary modification in existing panel as required at site complete including taking down existing all as specified and directed.
S & F fan regulator , AC, 230V, single pole electronic, step type, complete, all as specified and directed.
S & F Two module, Fan regulator, step type, AC ,230V, electronic, complete, all as specified and directed.
S & F One module, Fan regulator, step type, AC ,230V, electronic, complete, all as specified and directed.
Taking down carefully copper/ aluminium point wiring (Light, fan, socket or power) compete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. all as directed.
Point wiring with 1100 V grade 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistranded passing through and including heavy duty PVC casing capping with all accessories, surface type on wall/ roof/ floor with concealed MS box / Surface type PVC box as required at site with laminated top cover duly earthed with 1.5 sqmm multistranded PVC insulated copper conductor cable for one light point /bell point /fan point controlled by one switch complete all as specified and directed.
All as per item No 33 here-in-before but in same board with other switches for 5 Amp switch socket with earth wire 1.5 sqmm PVC insulated multistranded copper conductor cable all as directed.
All as per item No 33 here-in-before but for 5 Amp switch socket on independent board all as directed.
All as per item No 33 here-in-before but size of cable 2.5 sqmm for 15 Amp switch socket with earth wire 2.5 sqmm PVC insulated multistranded copper conductor cable all as directed.
Concealed point wiring with 1100V grade 1.5 Sqmm single core PVC insulated cable, copper conductor multistranded passing through and including concealed PVC 20mm dia (light duty) conduit and conduit accessories with concealed MS / PVC box and logic modular white plate of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm as earth wire connected to common earth dolly as specified for one light point controlled by one switch all as specified and as directed. Note : (1) Rate quoted includes for cost of cutting chases in wall / floor / ceiling, making holes for MS / PVC box and making good to the original surfaces of any description disturbed. (2) Switch and socket shall be measured and paid for separately.
All as per item No 37 here-in-before but in same board with other switches for 5 Amp switch socket with earth wire 1.5 sq mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No 37 here-in-before but for 5 Amp switch socket on independent board all as directed.
All as per item No 37 here-in-before but size of cable 2.5 sqmm for 15 Amp switch socket with earth wire 2.5 sqmm PVC insulated multistranded copper conductor cable all as directed.
Sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of heavy duty PVC conduit pipe and accessories, one run of PVC insulated 4 sqmm copper conductor for earth continuity and taking down existing submain wiring complete all as specified and as directed.
Sub main wiring with 2 runs of 6 sqmm, single core, PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of heavy duty PVC conduit pipe and accessories, one run of PVC insulated 6 sqmm copper conductor for earth continuity and taking down existing submain wiring complete all as specified and as directed.
Sub main wiring with 2 runs of 10sqmm, single core, PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of heavy duty PVC conduit pipe and accessories, one run of PVC insulated 10 sqmm copper conductor for earth continuity and taking down existing submain wiring complete all as specified and as directed. Note for item Nos. 41, 42 and 43: 2 runs 4/6/10sqmm single core copper conductor, 1 run of 4/6/10sqmm copper conductor earth wire and PVC conduit and its accessories will be measured as one unit
S & F 20/22 W LED Surface mounted, batten fixture, 1200mm in length, with powder coated pressure dia cast aluminium housing and translucent diffuser. The fitting should have multichip on board LED metal clad PCB and dedicated heat shrink. The minimum lumens output of the system should not be less than 1450 lumens. The fitting should have surge protection of minimum 2 Kv input current <200mA, THD<10 % and CCT between 5000 k to 6500 K as directed.
S & F 10/12 W LED Surface mounted, batten fixture 600 mm in length, with powder coated pressure dia cast aluminium housing and translucent diffuser. The fitting should have multichip on board LED metal clad PCB and dedicated heat shrink . The minimum lumens output of the system should not be less than 1450 lumens. The fitting should have surge protection of minimum 2 Kv input current <200mA, THD<10 % and CCT between 5000 k to 6500 K as directed.
S & F 36W IP LED panel made from CRC housing with full window acrylic diffuser indoor (recessed/ Pendent) 2ft X 2 ft lighting fixture flat light dissipater. The CCT should be between 3000 k to 6500 K as directed.
S & F 42W IP LED panel made from CRC housing with full window acrylic diffuser indoor ( Surface mounted ) 2 ft x 2 ft lighting fixture flat light dissipater. The CCT should be between 3000 k to 6500 K as directed.
Disconnection and removing the u/s FTL tube rods and Supply and fix new Energy efficient FTL tube rods of 36/40 watts complete.
Disconnection and removing the u/s electronic ballast and S&F electronic ballast suitable for 1x36/40 watts FTL fitting complete all as specified and as directed.
Disconnection and removing the u/s CFL lamp and S&F CFL lamp 1x36watts 4 pin type complete all as spfd and directed.
Disconnection and removing the u/s ballast and S&F 1x36 watts CFL electronic ballast complete all as spfd and directed.
Disconnection and removing the u/s CFL lamp and S&F CFL lamp 1x18watts 2/4 pin type complete all as spfd and directed.
Disconnection and removing the u/s ballast and S&F 1x18 watts CFL electronic ballast complete all as spfd and directed.
Disconnection and removing the u/s CFL lamp and S&F CFL lamp 1x26watts 2/4 pin type complete all as spfd and directed.
Disconnection and removing the u/s ballast and S&F 1x26 watts CFL electronic ballast complete all as spfd and directed.
Disconnection & taking down the unserviceable/ vintage high wattage Building security light fittings and Supply & fixing energy efficient Intergral type LED 70 W light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mounted on MCPCB and testing compelte all as specified and directed
Siddique constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .