Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.2 LAccepted-AOC 00 IN FRONT OF SHIVPURI HOTEL NEAR KOTHI NO 14 SHIVPURI MADHYA PRADESH 473551 | SHIVPURI | MADHYA PRADESH | 473551 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹43.0 L+₹32,910.10 (0.77%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹43.3 L+₹66,853.65 (1.57%)Rejected-AOC 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹43.7 L+₹1.1 L (2.47%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹49.5 L+₹6.9 L (16.1%)Rejected-AOC HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹84,000
Closing Date
12 Jan 2021, 6:00 pmClosed
GE I CG PORBANDAR
MILTARY ENGINEERING SERVICES, DHQ-01 GE I CG PORBANDAR OPP BIRLA FACTORY PORBANDAR
REPAIR TO SUNKEN FLOOR, CHAJJA REPAIR, ROOF TREATMENT WORK, FLOORING WORK, SPALLING WORK, PLUMBING AND SANITARY FITTINGS AND MISCELLANEOUS BR WORK ETC AT CG JETTY AND CGDHQ-01 PORBANDAR UNDER GE I CG PORBANDAR
2020_MES_400022_2
8566
Open Tender
Civil Works
Item Rate
180 days
DHQ-01, JETTY PORBANDAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹84,000
Yes
18 Feb 2021
31 Dec 2020
13 Jan 2021
31 Dec 2020
12 Jan 2021
7 Jan 2021
Amount
SCHEDULE 'A'
M&L PCC 1:7:12 with brick aggregate as in lean concrete/filling concrete
Supply only Integral water proofing compound. Make :Pidilite, Dr Fixit, SICO
M&L Cement concrete type B0 (1:2:4 using 12.5 mm graded stone aggregates) as in coping of masonary wall including weathering slightly rounded or chamfered angles and throating including demolition of old concrete and removal of debris outside MD land as directed including necessary form work complete all as specifed and directed.
M&L Cement concrete type B1(1:2:4 using 20 mm graded stone aggregates) in roof padding concrete, kerbs or mud stops, rounded or chamfered on edges all around at the junction of parapet and the roof slab all as directed by Engr-in-Charge
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in Columns,pillars,piers, posts and struts Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in chajjas, floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like. Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in beams,cantilevers, bressumers and lintels over 1.5 mtr span complete all as specified and directed by Engr-in-charge. Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge
M&L RCC nominal mix type A1, (1:1.5:3, using 20mm graded stone aggregates) as in slabs supported onwalls, beams and colums in floors, roofs, landings, balconies, canopies ,deck slabs and in shelves and the like complete all as specified and directed by Engr-in-charge Note: The proportioning of cement and aggregate for mixing by weight shall be as directed by the Engineer-in-charge.
Form Work to sides of pillars colums square or rectangular ,for rough finished surfaces of flat concrete.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of flat concrete.
Form work to soffits of suspended slab such as roof slab floor slab landing and similer work not exceeding 200mm thick (horizontal or sloping) ,for rough finished surfaces of flat concrete.
Formwork to chajjas including edges ,for rough finished surfaces of flat concrete.
M&L Porbandar stone masonary, block in course, well bonded and bedded, built in CM 1:6 all as specified and as directed by engineer-in-charge.
Cutting holes in Stone walls exceeding half brick built in cement mortar including making good after inserting and setting spouts all as specified.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sq. m and n exc 2 sq. m each
Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each .
S&F Factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with 19x 19mm MS square tubes, provided with EPDM rubber gasket throughout the frame fixed in opening complete as per manufacturer's specifications and as directed by Engineer-in-Charge Make :- M/s Sintex Industries Ltd, M/s Rajshree Plastiwood Ltd,
S & F 30 mm thick factory made solid panel PVC door shutter conferming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C' channel of size 30x50mm forming stiles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of 'C' channel using PVC solvent adhesive complete as per manufacturers specifications & drawings ass as directed by Engineer-inCharge Make :- M/s Sintex Industries Ltd, M/s Rajshree Plastiwood Ltd,
S&F Butt hinges, 100 mm medium weight, cold rolled Stainless steel complete all as specified and as directed by Engr-in-Charge.
S&F 125 mm long Extruded aluminium alloy handles, fabricated type,anodised (ISI Marked) complete all as specified and directed.
S&F Aluminium, anodised, barrel tower bolts 150 mm long of extruded section and fixed complete all as specified and as directed by Engr-in-Charge.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete con- forming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer-in-Charge.
M&L Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips. etc complete all as specified and directed by Engr-in-charge.
M&L Mild steel CRS TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips. etc complete all as specified and directed by Engr-in-charge.
M&L Mild steel CRS TMT bars 5mm dia and over upto 10mm dia in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips. etc complete all as specified and directed by Engr-in-charge.
M & L Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile srtength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws at any height including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge.
M&L 75mm thick PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in plinth protection, flooring incl necessary formwork incl finishing surface of concrete by brooming etc complete.
Roughening/cleaning surfaces of roof with wire brush, sweeping clean and washing down with water to remove dust etc
M&L Non-Skid coloured ceramic tiles 7 to 8mm thick rectified (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm over & including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling complete all as specified and as directed by the Engineer-in-Charge Make : Kajaria, Somany, Orient bell
M&L Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm over & including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes, set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling complete all as specified and as directed by the Engineer-in-Charge. Make:- Somani ,Orient Bell, kajaria.
M&L Glazed coloured ceramic tiles in verticle surfaces 300x 450x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over backing bedding layer 10mm thick 1:4 and pointed in white or coloured cement to match etc complete all as specified and directed by Engr-in-charge. Make : Kajaria, Somany, Orient bell
M & L Glazed coloured ceramic tiles in vertical surfaces 300mmx450mmx7mm thick including over 10mm thick rendering of cement mortar (1:4) for laying floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling complete all as specified and as directed by the Engineer-in-Charge. Make : Kajaria, Somany, Orient bell
Treatment of sunken floor slab compraises of the following specifications and all as specified :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout (Cost cutting holes and pipes shall be measured and paid separately) (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out.( WPC shall be measured & paid separately) (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.(This item shall be measured and paid separately) (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately) (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (this item shall be measured & paid separately) Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. Cost of testing is inclued in the rates quoted above.
S&F 50mm dia GI tubing medium grade galvanised,with all fitting as in sunken floor etc complete all as specified and directed..
M&L 50mm thick PCC,C1 (1:3:6, using 20mm graded stone aggregates for covering pipes laid in sunken portion all round including painting with anticorrosive paint complete all as specified and directed.
M&L Applying two coats of polymer modified cementious water proof coating as per manufacturers instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. Make :- Pidilite, Sico, Dr fixit, Shalicem
M&L Injection grouting in RCC slab cast/laid to the slope as directed/as per site conditions. After RCC slab is laid, cured and fully set, water shall be ponded in the sunken slab portion as per specified ponding test. The location of seepage/leakage, if any, shall be identified and marked. The portion of the slab where leakage/seepage is observed shall be repaired with grouting at contractor's expenses. The area of dripping/leakage shall be cleaned to expose the surface. Mark the spots for injection grouting. If leakage is through a crack, mark grouting points along the crack in a staggered manner. If the leakage is across the area mark grouting spots in a grid pattern. Drill grouting holes so as to neatly fit the injection packers. Drilling to be done at an angle of 45 to the plane of grouting surface. Fix PVC/MS nozzles in the low viscosity, polyurethane resin/epoxy grout using a grouting pump. Repeat the process after 1 or 2 days if the leakage continues at some point. allow to cure for 24 hours and seal the grouting holes appropriately using epoxy putty etc complete all as specified and as directed. Make :- Dr Fixit, Pidilite
M&L 15mm thick plastering in cement & sand mortar 1:4 in 2 coats (10 mm thick backing coat and 5 mm thick setting coat mixed with water proofing compound) on fair faces of brick work or concrete surfaces, finished even and smooth (w/o using extra cement) including taking down cement plaster, any description on brick or stone walls and ceiling including racking of joints hacking for key scrubbing down with water etc for storey incl all necessary scaffolding etc as directed by Engr-in-Charge (WPC shall be mesured and paid seperately).
M&L for rendering 5 mm thick cement plaster in brick or concrete surfaces in CM 1:3 as in ceiling finished even and smooth without using extra cement including taking down cement plaster, any description on brick or stone walls and ceiling including racking of joints hacking for key scrubbing down with water etc for storey incl all necessary scaffolding etc as directed by Engr-in-Charge (WPC shall be mesured and paid seperately).
M&L Preparation of new plastered surfaces of walls/Ceiling and applying two coats of acrylic emulsion exterior grade (100%) over a coat of primer complete all as specified and directed incl all necessary scaffolding etc. Make :- Asian Apex, Berger Weather Coat, Dulux Weather Shield
M&L Rendering 15mm thick in cement mortar 1:6 on fair face of brickwork finished even and smooth without using extra cement and applying 3mm thick wall care putty on wall incl taking down of old cement plaster complete all as specified and directed.
M&L 10mm thick rendering in cement and sand mortar 1:4 on roof padding concrete surface for levelling course rounded or chamfered on edges, slopping mixed with water WPC @ 2% by weight of cement, finished even & smooth surface without using extra cement complete all as specified & directed. NOTE : (WPC shall be measured and paid seperately)
M&L preparation of new plastered or unplastered surfaces of walls including scrapping and applying two coats of oil bound distemper over layer of smooth putty finish over a coat of primer strictly as per manufactuure instruction with smooth roller finish complete all as specified and directed. MAKE : Asain Paint Tractor uno or Berger Bison or equivalant in nerolac.
M&L Preparing old plastered surfaces ofceiling and apply two coats of white wash.
Preparation of old painted wooden surfaces over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed. Make :- Asian (Apcolite) or Nerolac (Hi-gloss) or Berger (Luxol Hi-gloss)
M&L Prepation of old decorated wall surface for receiving textured paint with following layers of treatment. (a) Apply one coat of primer to the prepared surface using white. (b) Apply external wall care putty (minimun 3mm thick) and prepare the surface to an even and smooth finish, check the surface to a true level surface and rectify the dents, if any noticed, before applying subseqent coats. (c) Apply one coat of primer on putty surface using white cement. (d) Apply a base coat of texture paint as per manufactures (e) Apply a finishing coat of textured paint and creat the design as approved by Engineer in Charge.
M&L Preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of zinc chrome primer, complete all as specified and as directed.
Taking down CI/ rain water pipes (any size or pattern) including all fittings, heaads, shoes, bends etc
S&F 160mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including PVC/GI clamps of approved shape and size approved by GE at any height, any location, any floor including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge.
S&F 160mm dia PVC (SWR) bends/shoes any radius fixed to pipe at any location/height including necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including PVC/GI clamps of approved shape and size approved by GE at any height, any location, any floor including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) bends/shoes any radius fixed to pipe at any location/height including necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) pipes single socketed,in any length with rubber ring joints, fixed in wall including PVC/GI clamps of approved shape and size approved by GE at any height including necessary scaffolding complete all as specified and as directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) bends/shoes any radius fixed to pipe at any location/height including necessary scaffolding etc complete all as specified and as directed by Engineer-in-Charge.
M&L in repair100mm. PVC (SWR) Nahani trap / floor trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed by Engineer-in-Charge.
M&L in repair75 mm. PVC (SWR) Nahani trap / floor trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed by Engineer-in-Charge.
S&F in repair 110 mm dia PVC bend of any radius with ovel access door and jointed with neat cement paste.
S&F in repair 75 mm dia PVC bend of any radius with ovel access door and jointed with neat cement paste.
S&F in repair 110 mm dia PVC branch piece single branch of any radius with ovel access door and jointed with neat cement paste.
S&F in repair 110 mm dia PVC branch piece double (equal or unequal) ordinary or inverted or with parallel brach and jointed with neat cement paste.
S&F WHB/Kitchen sink collapsible waste pipe out let upto Nahani trap complete.
S&F 15 mm dia Pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and directed by Engineer in Charge. Make: CERA Cat Pat No-F1005101 or Equivalent
S&F 10 lit.capacity PVC valveless, syphonic action type, flushing cistern,low level, white, with inlet,ball valve, float and handle including brackets complete all as specified. Make : Prayag (Cat Pat No-501) or equivalent as approved by Engr-in-Charge
Removing and refixing only high or low level flushing cistern (inclusive of brackets),and connection to pipes .
Removing and refixing only Vitreous china wash basin white flat back any size incl brackets if required complete.
S&F Vitreous China wash downwater closet pan (pedestal pattern), white (including fixing bolts & flush pipe, plastic water closet seat,black, closed pattern with bottom, and cover and mild steel chromium plated or aluminised hinging device etc.) complete all as specified and directed by Engineer-in-Charge Make :- Prayag or equivalent
S&F in repairs, Plastic water closet seat covers, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device. Make :- Prayag or equivalent
S&F Stainless steel grating cover fixed in repairs to suit the 100mm/75mm dia nahani trap fixed with cement.
S&F Wash hand basin vitreous china White flat back size 550mmx400mm including cast iron brackets, chromium plated waste coupling, PVC connection, waste pipe up to floor trap etc in repair all complete as specified. Make: Prayag or equivalent
S&F 100mm dia CI sanitary connection- short connections pipe of length upto 300mm
M&L Vitreous water closet (orissa pattern) 'long pan', white with 'P' or 'S' trap, front or back inlet any pattren complete fixed in repairs complet all as directed. Make :- Prayag or equivalent
M&L100 mm dia Cast iron floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
Taking up & down steel tubing & connections of follwing size complete all as specified and directed. (a) 20 mm bore
All as per item no 73 but b) 15 mm bore
S&L 25mm OD, CPVC pipes, of SDR -11 & plain CPVC SDR fittings for Hot/cold water for sizes mentioned below including all fittings and solvents and special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor etc, Unions, Flange and tank adapter all as per manufacturers recommendations and as specified.
S&L 20mm OD, CPVC pipes, of SDR -11 & plain CPVC SDR fittings for Hot/cold water for sizes mentioned below including all fittings and solvents and special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor etc, Unions, Flange and tank adapter all as per manufacturers recommendations and as specified.
S&F Cabinet Mirror 400 x 500 mm, Make : Prayag (Cat Pat No 554) or equivalent as approved by GE. complete all as specified and as directed by Engr-in-Charge
S&F Toilet Paper Holder, complete all as specified and as directed by Engr-in-Charge, fixed . Make : Prayag (Cat Pat No BA-18) or equivalent from makes given in list of makes.
S&F in repair decorative glass corner shelf round 300mm size with stainless steel railing, fixed with D type stainless steel bracket on wall of approved design and pattern all as specified. Prayag (Cat Pat No- BEA-46) or equivalent model as approved by Engr-in-Charge
S&F CP brass 125mm size shower rose with rubit cleaning system with shower arm and flange suitable for 15mm bore GI tubing complete all as specified. Make : Prayag or equivalent
S&F in repair Fancy type bib taps brass CP with wall flange suitable for 15mm bore GI tubing with necessary fittings complete all as specified. Make : Prayag or equivalent
S&F in repair Fancy type two way bib taps brass CP with wall flange suitable for 15mm bore GI tubing with necessary fittings complete all as specified. Make : Prayag or equivalent
S&F in repair Fancy type Brass CP mixer formixing hot & cold water screwed down for iron pipe and fixed 15mm bore GI tubing with necessary fittings complete all as specified. Make : Prayag or equivalent
Supply and fixing in repairs angular stop valve cast copper alloy ,screwed down ,high pressure or Capstan head handle screwed both ends for iron pipe or for union and fix of size 15 mm bore Make: Prayag (Cat Pat No-8510) or Cera.
S&F in repair fancy Concealed stop valve with long shark and adjustable wall flange including union suitable for 15mm bore GI tubing, with necessary fittings complete all as specified and directed. Make : Prayag (Cat Pat No 9918) or equivalent
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm Make : Prayag and equivalent as approved by Engr-in-Charge
S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm Make : Prayag and equivalent as approved by Engr-in-Charge
S&F Health Faucet square with 1 mtr tube and hook complete all as specified and as directed by Engr-in-Charge, fixed . Make : Prayag (Cat Pat No-BEA-85) as approved by Engr-in-Charge
Demolition of stone masonry built in cement mortar of any description all as specified and as directed by Engr-in-Charge
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and removed of debris outside MD land complete all as directed by Engr-in-Charge
Demolition of Cement concrete in any description and in any position not other wise specifically provided directed by Engineer-in-Charge and removal of debris to out side MD land.
M&L Crack filling by cleaning plastered surface and remove all loose particles, dirt, vegetation etc. Define the crack with sharp edge tool then clean and moisten, Applying ready to use acrylic polymeric non-shrink ' PAINTEX - 4' upto 5mm to 12mm wide cracks and finish at all heights, level etc, complete aafter 24hrs inspect and if required as a result of auto suction, provide another filling over the same complete all as specified and directed. Make : Choksey Chemical pvt ltd, or equivalent in Dr fixit, STP
Preparing of old/new surfaces of walls/ceiling washing the surface thoroughly, filling the cracks, creaves with crack filling compound as suggested by the manufacturers and applying two coats of Rain coat manufactured by Dr Fixit of Piddilte Industries Ltd. (shade to match the existing paint) incl necessary scaffolding for work all as specified and as directed by Engineer in Charge.
M&L APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3 Kg/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method. (iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface.
M&L for repair to Spalling of concrete, damaged surface of RCC elements like beams, columns, wall, slab by removing all loose cement plaster/concrete, dust, oil, paint, grease, waterproof coating etc, Expose fully any corroded steel in the repair area and remove all scale and corrosion deposits , Apply rust remover for rust free bars, fix new reinforcemt if required, apply Dr. fixit Epoxy zinc primer over the cleaned rebars and allow it to dry before pouring of Dr Fixit micro concrete or equivalent , appllying one coat of Dr fixit epoxy bonding agent before pouring of mix concrete, providing and laying of micro concrete at 20 to 40mm thickness by using the recommended water powder ratio mix the microconcrete with pan mixer as per manufacturer's instruction including watertight shuttering at any position including necessary curing and removal of debris outside MD land complete all as specified and directed by Engineer-in-Charge. (New TMT Reinforcement if required shall be used and paid separately) Note : (i) Rate of rust remover, Epoxy zinc primer, Epoxy bonding agent and micro concrete is included in this item. Make -Dr Fixit/Build Core/Fosroc/Pidilite/ Krishna conchem
Preparation of old decorated surfaces of walls by scrapping old paint with steel wire brush or by any means, washing the surface throughtly and applying one coats of acrylic emulsion exterior grade (100%) over a coat of primer complete including necessary scaffolding for any position/height all as specified and directed by the Engineer- in- Charge. Note :- (a) Acrylic painting shall be done with rollers. Make :- Asian Apex, Berger Weather Coat, Dulux Weather Shield
M&L Protecting the roof with water proofing coating(Dr. Fixit) complete as specified below: (a) Wire brush the surface to remove loose particles & laitance wash with clean water. (b)complete crack filling & reinstate damaged portion shall be filled with polymer modified mortar as recommended. (c) allow the repair surface to cure for 24 hours afterwards wet the surface to a SSD condition (d) apply one coat of primer by brush and allow to dry for 4 hours (e) Apply one coat of water proofing coating over the primed surface by brush (f) on the wet primed surface overlay a open- woven fiber glass mesh min 40 GSM of size 2mm x 2mm and allow it to soak completely (g) immediately there after apply the second coat with a roller to ensure complete coverage of the fibre mesh (h) apply the 3rd coat after 6 to 8 hours, once the 2nd coat is dry Make : Crack filler : Dr. Fixit crack-X Paste, Dr. Fixit crack -X shrinkfree, Shaliseal CPM of M/S STP Ltd Prime Coating : Dr. Fixit Primeseal Water Proofing Coating : Dr. Fixit Newcoat, Waterseal concentrate of M/s Krishna Conchem Products, Shalicry 215 of M/s STP Ltd.
M&L for water proofing treatment by cleaning the RCC terrace by removing dust, dirt etc. with grinder. Identifying the cracking, damaged IPS & filling the same with polymer Modified Mortar using MASTERLATEX, cement, sand in the ratio of 1:2:4, applying two coats of 'Techcoat-white' @ 2 Sqm/Litre in 2 coats with DFT of 80-90 Microns on primed surface by using spl grade of 'Techoxy-3', Cure the surface for 48-72 Hrs complete all as specified and as directed by Engr-in-Charge. Make : Choksey Chemical pvt ltd, or equivalent in Dr fixit, STP
M&L for providing and applying 20-25mm thick sand faced cement plaster to external surfaces in two coats with first coat in 10-12mm thick in CM 1:4 and second coat in 8-10mm thick in CM 1:4 finished in proper line and level on primed surface with MASTERLATEX and cement @ 1:1 then apply plaster on wet surface. Add in both the coats shrinkage compensating admixture cum plasticizer 'MASTERPROOF IWP-1 @ 100-200 ML per 50 Kg bag of cement, incl taking down of old plaster and removing debris from site complete all as specified and as directed by Engr-in-Charge. Make : Choksey Chemical pvt ltd, or equivalent in Dr fixit, STP
Removing of dismantled material / debris etc outside MD land except the dismantled items taken in schedule of credit.
m/s.a.t.odedra
SHREE CHAMUNDA ENTERPRISE
BABUBHAI BHIMABHAI PANDAVADRA
roxy enterprise
K K Construction Co
SURAJ ENTERPRISE
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .