GEMC-511687788667201
Awarded to REVA HEALTHTECH PRIVATE LIMITED
₹11,000
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BAIN CIRCUIT ADULT/CHILD | ANGIPLAST | - | 20 NOS | ₹550 | 11,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11,000Qualified Make: Angeltouch
Model: ANGIPLAST A 41 SECOND FLOOR KESHOPUR INDUSTRIAL VIKASPURI VIKASPURI WEST DELHI DELHI 110018 UDYAM DL 03 0000933 07AAECV0638E1ZJ B R MII STATUS AS NOT VERIFIED | WEST DELHI | DELHI | 110018 | Make: Angeltouch
Model: ANGIPLAST | ₹11,000 | L1 | Qualified |
| 2 | L2₹11,200+₹200 (1.82%)Qualified Make: Surgeon"s solution
Model: SURGEON SOLUTION A1 DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110094 INDIA | NORTH EAST DELHI | DELHI | 110094 | Make: Surgeon"s solution
Model: SURGEON SOLUTION | ₹11,200+₹200 (1.82%) | L2 | Qualified |
| 3 | L3₹12,000+₹1,000 (9.09%)Qualified Make: ariette
Model: Ariette 221 SHIV MANDIR ROAD 221 SHIV MANDIR ROAD PEERAGHARI PEERA GARHI WEST DELHI DELHI 110087 UDYAM DL 11 0020736 07AAAPG8214C1ZB B R | WEST DELHI | DELHI | 110087 | Make: ariette
Model: Ariette | ₹12,000+₹1,000 (9.09%) | L3 | Qualified |
| 4 | Disqualified Make: NA
Model: ANY-1 00 PC GROUP AKHARI BYPASS TRIMUHANI CHUNAR ROAD VARANASI VARANASI VARANASI UTTAR PRADESH 221011 | VARANASI | UTTAR PRADESH | 221011 | Make: NA
Model: ANY-1 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
14 Aug 2018, 9:00 amClosed
Bain Circuit (Coaxial) -Anesthesia Breathing Bain Circuit (Coaxial) -Anesthesia Breathing ( 20 ) Technical Specifications Specification Specification Name Values Allowed Values GENERAL Type of Circuit Bain Circuit (Coaxial)-for mechanica l
spontaneously breathing patients - Usage Adults Paediatrics
Adults Usable for spontaneous and controlled ventilation Yes - Sterility sterile - Utility Single use- disposable Single use- disposable
Reusable Method of Sterilization Others - Autoclavable No - Shelf Life(years) 5 - The product should have shelf life of at least 2/3rd of the total shelf life at the time of supply Yes - FUNCTIONAL Delivery of anaesthic gases and vapours Yes - Oxygenation of the patient Yes - 1/4 Co2 elimination Yes - CONSTRUCTION Minimum dead space and low resistance to flow Yes - Reservoir bag Available - Reservoir bag type Open Tail Open Tail
Spring loaded valve Parallel entry of fresh Gas line at the patient connection Yes - FGF tube runs coaxially inside the outer transparent corrugated tubing Yes - Fixed elbow and luer lock port for safe monitoring at the patient end true true
false Expiratory valve at the patient end true true
false Double swivel elbow elastomeric cap at patient end true true
false Accurate and adjustable pressure limiting valve with safety feature true true
false Suitable adaptors to connect to various parts of breathing system
flow meter etc Yes - DIMENSIONS Corrugated Tube ID(mm) 22 Corrugated Tube length (mm) 1600 Fresh Gas flow tube dia (mm) 7 Fresh Gas flow tube length (mm) 1600 Reservoir bag size to allow respiratory monitoring and/or assistance(ml) 2000 MATERIAL Material of tubes ( Light weight
Medical Grade
Non-toxic
Latex Free) YES - Kink resistant FGF tube Yes - 2/4 Material of the reservoir bag Antistatic rubber Antistatic rubber
Neoprene
Latex free PACKING Type of packing Single
individually packed in soft wrap Single
individually packed in soft wrap
Single
individually packed in blister pack CERTIFICATION Tissue Implantation testing certificate to be provided Yes - Submission of Test Report from Central GOVT/NABL/ILAC accredited Lab or from manufacturer's inhouse test report to prove the conformity to the declared specification at the time of supply Yes - Certification available CE - Product conformity certificate is to be provided to the buyer Yes - Availability of valid Drug License Yes - Drug License No E(0698)/12/W - Drug License Date 27/12/2012 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Desh Raj Sharma 175008
Principal
SLBS Govt. Medical College & Hospital
Mandi at Nerchowk. 20 15
438379
GEM/2018/B/61987
GeM Contract
Bain Circuit (Coaxial) -Anesthesia Breathing
GeM Contract
15 days
Himachal Pradesh; Mandi
PRODUCT
Awarded to REVA HEALTHTECH PRIVATE LIMITED
₹11,000
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| BAIN CIRCUIT ADULT/CHILD | ANGIPLAST | - | 20 NOS | ₹550 | 11,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Bain Circuit (Coaxial) -Anesthesia Breathing Bain Circuit (Coaxial) -Anesthesia Breathing ( 20 ) Technical Specifications Specification Specification Name Values Allowed Values GENERAL Type of Circuit Bain Circuit (Coaxial)-for mechanica l | - | - | - |
| spontaneously breathing patients - Usage Adults Paediatrics | - | - | - |
| Adults Usable for spontaneous and controlled ventilation Yes - Sterility sterile - Utility Single use- disposable Single use- disposable | - | - | - |
| Reusable Method of Sterilization Others - Autoclavable No - Shelf Life(years) 5 - The product should have shelf life of at least 2/3rd of the total shelf life at the time of supply Yes - FUNCTIONAL Delivery of anaesthic gases and vapours Yes - Oxygenation of the patient Yes - 1/4 Co2 elimination Yes - CONSTRUCTION Minimum dead space and low resistance to flow Yes - Reservoir bag Available - Reservoir bag type Open Tail Open Tail | - | - | - |
| Spring loaded valve Parallel entry of fresh Gas line at the patient connection Yes - FGF tube runs coaxially inside the outer transparent corrugated tubing Yes - Fixed elbow and luer lock port for safe monitoring at the patient end true true | - | - | - |
| false Expiratory valve at the patient end true true | - | - | - |
| false Double swivel elbow elastomeric cap at patient end true true | - | - | - |
| false Accurate and adjustable pressure limiting valve with safety feature true true | - | - | - |
| false Suitable adaptors to connect to various parts of breathing system | - | - | - |
| flow meter etc Yes - DIMENSIONS Corrugated Tube ID(mm) 22 Corrugated Tube length (mm) 1600 Fresh Gas flow tube dia (mm) 7 Fresh Gas flow tube length (mm) 1600 Reservoir bag size to allow respiratory monitoring and/or assistance(ml) 2000 MATERIAL Material of tubes ( Light weight | - | - | - |
| Medical Grade | - | - | - |
| Non-toxic | - | - | - |
| Latex Free) YES - Kink resistant FGF tube Yes - 2/4 Material of the reservoir bag Antistatic rubber Antistatic rubber | - | - | - |
| Neoprene | - | - | - |
| Latex free PACKING Type of packing Single | - | - | - |
| individually packed in soft wrap Single | - | - | - |
| individually packed in soft wrap | - | - | - |
| Single | - | - | - |
| individually packed in blister pack CERTIFICATION Tissue Implantation testing certificate to be provided Yes - Submission of Test Report from Central GOVT/NABL/ILAC accredited Lab or from manufacturer's inhouse test report to prove the conformity to the declared specification at the time of supply Yes - Certification available CE - Product conformity certificate is to be provided to the buyer Yes - Availability of valid Drug License Yes - Drug License No E(0698)/12/W - Drug License Date 27/12/2012 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Desh Raj Sharma 175008 | - | - | - |
| Principal | - | - | - |
| SLBS Govt. Medical College & Hospital | - | - | - |
| Mandi at Nerchowk. 20 15 | - | - | - |
Exempted
14 Aug 2018
10 Aug 2018
contract_GEMC-511687788667201.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_438379.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .