Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹35.6 LAccepted-AOC MATTILIPARAMBIL HOUSE SAHODHARAN AYYAPPAN ROAD EROOR WEST PO THIRUPUNITHURA 682306 | THIRUPUNITHURA | ERNAKULAM | KERALA | 682306 | L 1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L 2₹38.8 L+₹3.0 L (8.41%)Rejected-Finance NIVAS S J NIVAS 26 1798A CHALANCHERY ROAD MAMMAJIMUKU THEVARA KOCHI 682 013 | KOCHI | ERNAKULAM | KERALA | 682013 | L 2 | Rejected-Finance Rejected being not lowest | |
| 3 | L 3₹41.0 L+₹5.1 L (14.3%)Rejected-Finance | L 3 | Rejected-Finance Rejected being not lowest | |
| 4 | L 4₹42.3 L+₹6.4 L (17.9%)Rejected-Finance DOOR NO XXVII 1580 KOITHARA ROAD PANAMPILLY NAGAR KOCHI 682 036 | KOCHI | ERNAKULAM | KERALA | 682036 | L 4 | Rejected-Finance Rejected being not lowest | |
| 5 | L 5₹46.7 L+₹10.9 L (30.4%)Rejected-Finance | L 5 | Rejected-Finance Rejected being not lowest |
Tender Value
₹47.3 L
EMD Value
₹94,500
Closing Date
2 Dec 2020, 6:00 pmClosed
GARRISON ENGINEER NAVAL WORKS
GARRISON ENGINEER NAVAL WORKS MILITARY ENGINEER SERVICES KATARIBAGH NAVAL BASE POST KOCHI 682004
PROVISION OF PAVER BLOCK AT VARUNA APARTMENTS ELAMKULAM KOCHI AND OTHER SANCTIONED WORK OF AGE B/R I ,AGE B/R III AND AGE E/M UNDER GE NW NAVAL BASE KOCHI
2020_MES_392808_1
GE(NW)/KOCHI/8327/E8
Open Tender
Civil Works
Item Rate
180 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE(NW) KOCHI
₹94,500
Yes
9 Jan 2021
5 Nov 2020
4 Dec 2020
5 Nov 2020
2 Dec 2020
19 Nov 2020
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in hard/ dense soil complete all as specified.
Dismantling of Stone slabs and tiles of any description or thickness, laid dry or laid dry and pointed in floors, aprons etc and removing serviceable tiles to store and rubbish off the premises
M & L for hardcore of broken stone of boulders gauge exc. 63 mm but n exc 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified .
M&L for 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in sub base of floor complete all as specified .
M&L for Screed bed or bedding layer or mortar in CM (1:6), 15 mm thick for laying in floor finishes all as specified and directed .
M&L for chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick with mixture of grey and white cement in equal proportion and no pigment, set, jointed and pointed in neat cement slurry complete all as specified
laying only Machine pressed precast concrete interlocking paver block any shape and size (tiles obtained from item No 2 shall be used) all as specified
M&L for sand cushioning for laying inter locking tiles Spreading and levelling in layers n exc. 25 cm thick well ramming including watering all as specified and directed
Dismantling steel posts or struts any section,Posts embedded in Concrete, brick work, masonry, etc including taking out embedded portion and making good disturbed ground
S&F in repairs galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
Excavating in trenches, not exceeding 1.5 m wide andnot exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc.not exc 10 sq m on plan and not exc 1.5 m in depth and getting out in hard/dense soil / bituminous road/hard standing/PCC floor complete all as specified
Demolition of brickwork or stone/boulder masonry or PCC block masonry built in cement mortar including all quoins,pillars etc excluding ashlar facing,dressed stone work and pre cast concrete articles and pre cast concrete block walling complete all as specified and as directed .
Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition)
M&L for plain cement concrete in 1:4:8 type D-2 using 40 mm graded stone aggregate for foundations, filling and mass concrete, concrete layer below plinth beam etc all as specified
M&L for plain cement concrete in 1:2:4 type B-1 using 20 mm graded stone aggregate for foundations of fencing post etc including necessary form work all as specified
M&L for stone Walling of random rubble, uncoursed, well bonded, built in Cement mortar 1:6 as in retaining walls, abutments and similar work complete all as specified
All as per item No 16 above but except boulder built in Cement mortar 1:6 as in retaining walls, abutments and similar work complete all as specified(boulders obtained from item No12 shall be used)
M&L for pre-cast cement concrete block masonry 1:3:6 Type C1, using 20mm graded aggregate with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed .
M&L for providing PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) copings, bed plates, kerbs, etc including necessary form work complete all as specified
M&L for Mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with andincluding mild steel wire (annealed) not less than 0.9mm dia or securing with clip all as specified and directed .
All as per item No 20 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
M&L mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified
M&L for rendering 10mm thick on brick work or concrete surfaces in 1:4 cement mortar finished even & smooth (without using extra cement.) all as specified and directed .
M&L for rendering 15mm thick on other than fair face of brick work or stone masonry surfaces in 1:4 cement mortar finished even & smooth (without using extra cement.) all as specified and directed .
M&L preparing new plastered surfaces of wall and applying three coats of white wash, complete all as specified and as directed.
M&L for preparation on new steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of metal primer complete all as specified .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated materials n. exc. 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and as directed .
S & F concertina coil of 450mm diameter in closed condition and strecth to 500 mm dia and 8 mtr length. made out of 2.59 mm dia spring steel core wire having zinc coating on core wire 240 G/Sqm (min) dipped with corrosion preventive fluid (rusilo 901) of castrol make in white colour and each coil having a minimum 50 turns (circles) and an average weight not less than 8.57 kg (plus or minus 5%) incluiding handle and spike at both ends of coil errected in position on top of compound wall by fixing with MS rod for securing including necessary welding to the MS sections etc all as directed.
Supply and fix in repairs Aura 500 mm dia Turbo Ventiloator made out of Aluminium with Fluro Carbon coating with additional fan leaves for efficient removal of warm and stale air with high quality Japanese NSK bearing No 6201z &6202z with suitable base plate made out of aluminium and suitable for installing on metal sheet and aluminium sheets including cutting and making holes of required size on existing roof for fitting the same or similar work to reach the height up to 20 metres etc complete all as specified and as directed.
M & L for coarse aggregate for granolithic floors, graded from 12.5mm to 4.74mm, spread and levelled in layers n exc.25 cm thick, watered and rammed to a true surface complete all as specified
M&L for Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80mm thickness, M-35 grade with grey cement and pigment all as specified
M&L for providing PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in lintels kerbs or mud stops or chamfered on edges, sides of paver blocks etc including necessary form work complete all as specified
M&L for rendering 10mm thick on brick work or concrete surfaces in 1:6 cement mortar finished even & smooth (without using extra cement.) all as specified and directed .
M & L for preparation surfaces of new wall surface and applying of two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified
S&F interlocking aluminium alloy anodized snap grid consists of main Tee runners of size 38mm x 25mm x 1.5mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x 1.5mm, 1200mm long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Tee 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25x25x2mm, aluminium alloy extruded section shall be aluminium anodized (minimum 15 micron) and shall conform to IS-733, IS-1285 and IS-737 including GI hangers 6 mm dia (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40x3mm size 60 mm long and expansion hold fastners 12.5mm dia 40mm long complete all as specified and directed
S&F 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework in ceiling as per manufacturer's instruction all as specified
M & L for preparation surfaces of new celing surface and applying of one coat of oil bound distemper over a coat of alkali resistant primer complete all as specified
M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base of floor complete all as specified .
M&L for non skid ceramic tiles light shade 7 to 8 mm thick (square / rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match all as specified
M&L for non skid ceramic tiles coloured 7 to 8 mm thick (square / rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match all as specified
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match ,including 10 mm thick rendering in cement mortar 1:3 all as specified
S&F vitreous china white wash down water closet pan (pedestal pattern), white including plastic water closet seat cover black, closed pattern with flat bottom, cover and mild steel chromium plated or aluminised hinging device, fixing bolts, PVC vlaveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float & handle including brackets, PVC connections 15mm size with PTMT nuts of length 600mm and flush pipe of polyethylene of low or high density or PVC 32mm dia, for low level cistern complete all as specified
S&F white glazed vitreous china WHB flat back size 550x400 mm including CI bracket etc incl waste coupling and PVC waste pipe 40mm bore 90cm long with coupling spring type complete all as specified
S&F Chromium plated brass pillar taps , fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe
S&F PVC connections 15mm size with PTMT nuts of length 450 mm complete all as specified
S&F towel Rail 450mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 170gms) all as specified
Excavating in trenches, not exceeding 1.5 m wide andnot exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc.not exc 10 sq m on plan and not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified
M&L for 150 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars all as specified
M&L Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in plain cement concrete Type D2, 1:4:8 using 40mm graded aggregate for 150 mm bore pipe complete all as specified
M&L for Providing, precast cement concrete 1:2:4, type B1, using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, shelves and similar articles with plain face window or door cills, lintels, bressummers, steps, quoin blocks (for use with masonry), string courses, copings, including chamfers weatherings, throating etc. and setting in mortar (1:6 ) complete with joints to match all as specified (Note : Reinforcement shall be measured and paid separately)
M&L for Mild steel TMT bars 10mm dia and over, as in main reinforcement as in piles, pile cap, plinth beam, coloumn, roof beam, roof etc, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with andincluding mild steel wire (annealed) not less than 0.9mm dia or securing with clip all as specified and directed .
M & L formwork to sides and soffits of floor or roof beams, bressummers, lintels, shelves including supports for fair finished surface of concrete all as specified
M&L for RCC 1:2:4 using 20 mm graded stone aggregate as in beams; cantilevers,bressummers,lintel over 1.5 mtr span, complete all as specified
S& F anodised aluminium with powder coating (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators/partition with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F anodised aluminium with powder coating (minimum thickness of powder coating 50 micron) door shutters, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleat, glazing with clips, rubber neoprene packing, anodised aluminium snap beading, 02 Nos handle in each door, hinges, screws etc including necessary locking arrangement complete all as specified. Note : Glazing/wire mesh/panels shall be measured and paid separately.
S & F 12 mm thick prelaminated particle board, interior grade, prelaminated prelaminated both sides with decorative choice laminations, fixed with screws to timber frame work
S&F 5.5 mm thick tinted sheet glass fixed to aluminium or wooden frame work using necessary beadings etc n exc 0.50 Sqm in each pane complete all as specified and directed
S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed
S&FCast iron body Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61to 80 kg and fixed
S&F anodised aluminium with powder coating (minimum thickness of powder coating 50 micron) window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified complete all as specified. Note : Glazing/wire mesh/panels shall be measured and paid separately.
S&F 4.00 mm thick tinted sheet glass fixed to aluminium or wooden frame work using necessary beadings etc n exc 0.50 Sqm in each pane complete all as specified and directed
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified .
S&F for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, ridge/valley etc, fixed with self tapping screws as complete all as specified .
Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in soft/loose soil complete all as specified
M&L for plain cement concrete in 1:3:6 type D-2 using 40 mm graded stone aggregate for foundations, filling and mass concrete, concrete layer below plinth beam etc all as specified
M & L for steel work in tubular pipes as in main mast including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified
S&F MS work as in plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified
M & L complete removal of existing treatment on wall surfaces including Washing, rubbing down and stopping of distempered and painted surfaces and application of two coats of appex ultima anti fungal paint over a coat of suitable primer complete all as specified and directed
M & L complete removal of existing treatment on wall surfaces and application of two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed
M & L for preparation of new ceiling surfaces and application of one coat of oil bound distemper complete all as specified
M&L preparation of old painted wooden surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and as directed .
M&L preparation of old painted steel surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed .
Dismantling floor hearth or wall tiling including cement mortar bedding removing serviceable tiles to store & rubbish off the premises complete all as specified.
M&L for Screed bed or bedding layer or mortar in CM (1:4), 15 mm thick for laying in floor finishes all as specified and directed .
M&L for non skid ceramic tiles light shade 7 to 8 mm thick (square / rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, vertical surfaces such as skirting, dados and risers to steps etcc. set & jointed in neat cement slurry & pointed in white or coloured cement to match all as specified
Taking down chowkats or frames with shutters (without taking off shutters from frames) exc 1.50 sq. m but not exc 4 Sqm each all as specified
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5.0mm plain colour PVC sheet reinforced with mild steel square tube, and fixing in opening as per specifications and drawing, complete all as specified and as directed.
S& F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L , point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade ISI-694 marked with valid CML No. single core multistranded cable in and including medium grade concealed PVC conduit not less than 25 mm dia and accessories ISI marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and including 1.6 mm thick MS sheet/ pressed steel sunken boxes depth not less than 50mm (earth dolly) duly painted with two coats of anti corrosive paint / aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paints over a coat of red oxide primer externally covered with 3 mm thick plastic laminated sheet cover for fixing of switches sockets and fan regulators etc. including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire for the following all as specified and as directed.
one light point controlled one ,one way switch 5 Amp
One fan /exhaust fan point controlled by one ,one way switch and regulator
One 5 pin 5 amps socket outlet an independent board.
One 5 pin 5 amps socket outlet on same board .
All as per item No 82 above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable as earth wire for one 6 Pin 16 Amps Socket outlet independent board.
All as per item No. 82 above but with 4 Sqmm copper conductor including 4 sqmm copper cable as earth continuity wire for AC point
S&F ceiling rose, 3 phase/ pvc/ polycarbonate, isolated body
S&F switch piano flush type 5A one way with cover plate all as specified and directed ..
S&F socket outlet 2 in 1 3 pin 5 Amps with cover plate all as specified and directed.
S&F S/S combination 6 pin 15 Amps flush type multi purpose with cover plateall as specified and directed .
S&F Stepped type electronic fan regulator flush type,120 W-2 Moduleall as specified and directed .
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V, 1200 mm sweep. BEE 5 star rated all as specified and directed. Make Havells / Orient / Usha
Taking down existing Ceiling fan,with sealing cable end dismantling blades and painting two coat with synthetic enamel paints by spraying including filling cavities with filler , servicing, and re hanging on original position including necessory conection with copper conductor .
Supply & fix metallic body exhaust fans heavy duty 900 Rpm AC single phase 230/ 240 V of size 380 mm sweep with louver including cutting of wall and making good surface and all as specified and directed Make Havells / Orient / Usha
M&L in repair earthing complete with galvanised steel earth plate electrode 60 cm x 60cm x6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meters below normal ground level, connected to GI earth strip 25x4 mm as earth lead 7.5 mtrs by means of bolts, nuts and washers of galvanised steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and indicated including testing on completion including taking out old earthing complete. Note : The rate is deemed to be inclusive of the cost of complete earth work in any type of soil. PCC 1:3:6 type C-1 for chamber,RCC 1:2:4 type B1 for cover slab 50 mm thick, reinforcement 8 mm CTD bars @ 100 mm c/c both way, necessary form work, handle, charcoal dust 20mm dia GI med grade for watering and 40mm dia GI med grade earth lead protection pipes with funnel and wire mesh all complete all as specified and directed.
Supply & fix Regal Batten for LED tube rods upto 1x22 W and crystal glass LED tube lights 1x20 W both side connections and connecting to electrical system with twisted copper flexible cable all as specified and directed. Make Havells Cat Part No REGALBATTENT 8 UPTO 1x22WSSBSWH and CRYSTAL UPTO 1213 T8 DS TL 20 W LED 865 SGLASS, Crompton Cat Part No: IGP 16KT-18 & LGT8-16-865-2 & Philips Cat Part No: TMC100 P1XT-LED22WP & essential LED tube 1200 mm, 20W
Supply and fix in replacement of LED flat panel with high brightness with glare free recessed 2 feet by 2 feet endura slim pro plus fitting as per Havells Cat part No ENDURA SLIM PROPLUS 2 X2PLR 28/36W LED857 MOD, Crompton AURA-1, Cat Part No:- CCR-127-36-57-SL-NW1+ & Philips Cat Part No: RC380BLED36S-6500G4L60W60PSUOD
Supply and fixing LED Mini mirror light 1 x 10W/12W Watt Wall/Surface mounted luminaries with engineering plastic housing, wired with all accessories complete incl provn of flexible copper wire from ceiling rose to light fitting terminal. Make- Make :Crompton Cat No. LDL-10-WW, Luker Cat Part No. LTSM10, Philips B No 21LED12S
S&F in replacement of LED slim panel lights 15W with highbrightness with glare free recessed mounted. Make Luker Cat Part No. LNPS15 or Philips/Wipro
S&F LED street light 36W IP-65 protection including suitable size GI bracket of 1.2 mtr length with necessary clamps and connecting to the electrical system complete all as specified and directed. Make Luker Cat Part No. LST36
S&F Sheet metal enclosure MCB TPN DB 8 way double door IP 43 type suitable for 200 amp\ including all electrical connection all as specified and as directed. Make: Schneider Cat Part No. A9HVTD08 / Legrand series XL 6300 enclosure / L&T Cat Part No. DBPSG008DD
S&F Sheet metal enclosure MCB SPN DB 8 way double door (metal door) IP 43 type suitable for 200 amp\ including all electrical connection all as specified and as directed. Make : Schneider Cat Part No. A9HSNS08 / L&T Cat Part No. DBSPN008SD / Legrand Cat Part No. XLᶟ400
S&F MCB SP (6-32) amp ,240 Volts ,10 KA including all electrical connection all as specified and as directed. Make : Schneider Cat Part No. A9N1P06B-32B / L&T Cat Part No. BB10320B / Indoasian Cat Part No. 811015
S&F MCB Four pole 63 amp 415 Volts ,10 KA including all electrical connection all as specified and as directed. Make : Schneider Cat Part No. A9N18372 / L&T Cat Part No. BB40630B / Indoasian Cat Part No. 811561
S&F MCB SPN 40 amp ,240 Volts ,10 KA including all electrical connection all as specified and as directed. Make : L&T Cat Part No. BB20400B or Schneider/ABB
Supply and fixing Sheet metal enclosure with plug top & socket ,single pole 20 Amps MCB all as specified and directed. Make : L&T Cat Part No. DBMPS120SD / Schneider Cat Part No. A9HMS220 / Indoasian Cat Part No. 811956
M&L for sub main wiring with 2 runs of 6 Sqmm (FRLSH) PVC insulated unsheathed multistranded copper conductor cable and 1 run of 6 Sqmm (FRLSH) cable as earth continuity wire and including PVC conduit concealed in wall/floor including cutting chesses and making good disturbed surface to match with existing surface. (Note:- 1. Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper conductor shall be measured as one unit length. 2. including taking down old unserviceable sub main wiring
Supply and fix in replacement on wall/Floor/Ceiling /Concealed in wall high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessay fittings, like Elbow, Tee, Socket , Reducer, bushings , step over bends ,end caps, End plugs, etcand with CPVC solvents cement of following sizes complete all as specified and directed. Note:Cutting /Chases on wall / floor will be measured and paid seperately under the relevent item if required. Make: Supreme/Eurotech /Astral/SFMC
All as per item No 106 here-in-before but of size 25 mm dia
All as per item No 106 here-in-before but of size 20 mm dia
M & L for CPVC Ball Valve of following sizes suitable for CPVC pipe incl necessary fittings complete all specified and directed. Make: Supreme/Eurotech /Astral/SFMC
All as per item No107 here-in-before but of size 25 mm dia
All as per item No 107 here-in-before but of size 20 mm dia
Supply and fixing of Bip cock, CP quarter turn with flange and areator, fancy type long nose with wall flange cast copper alloy with crutch or butterfly handle screwed for GI/ CPVC pipe of size 15 mm complete all as specified and as directed by.(Make : Model No F2004152 of Cera or equivalent make approved by Garrison Engineer
Supply and fixing 15 mm angle valve, half turn with flange, with flange type chromium plated for fixing accessories for for CPVC pipe complete specified and as directed .(Make : Model No: F2004201 of Cera or prayag/ hindware/Jaguar)
Supply and fixing of swivel overhead shower (minimum weight 40 grams) of PTMT any colour with shower arm (minimum weight 40 grams) 15mm size, 195 mm long with bend of 45 degree with flange for fixing with CPVC pipe complete and all as specified and as directed (Make : Model No: F7020307 of Cera (shower head) & F7040202 (Shower arms) or prayag/hindware/Jaguar).
Supply and fixing health faucet ABS body with wall hook and 1 metre SS braided rubber hose pipe , all as per specified and directed (Make : Model No: F8030102 of Cera or prayag/hindware/Jaguar).
Supply and fixing PVC connection pipe 16mm dia (outer 450mm long cold water complete with brass union on both sides to suit 15mm GI pipe complete all as specified and directed.
Supply and fixing in pillar taps, half turn with areator, cast copper alloy with capstan heads chromium plated fancy type screwed down high pressure with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed for 15mm bore pipe, complete all as specified and directed .(Make : Cera Model No:F8030103 or prayag/hindware/Jaguar).
Supply and fix concealed stop cock regular body,Quarter turn with adjustable wall flange chromium plated with CP cup fancy type of size 20mm complete all as specified and as directed .(Make : Model NO: F2004351 & F 4050102 of Cera or prayag/hindware/Jaguar)
Supply and fixing CP angle cock, self closers/ pressmatic with flange for urinal pots to fixed in 20/15 mm pipe complete all as specified and directed . Model No F9020203 of Cera or Prayag/Jaguar
M/L for cutting chases on walls floor etc not exceeding 20 cm girth and making good the disturbed surface to match with the existing after removing the existing concealed pipe/laying new pipe, complete all as specified and directed.
Supply and fixing in replacement of Rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted & fixed in position of capacity 1000 liters incl taking out u/s old one Make : Sintex (ISI)/ Aquatech
Supply, install, testing and commissioning of inverter splite air conditioner minimum 3 star marking with codeless remote control ecofriendly 410 A refrigerant 4500 K cal/hr, 50 Hz including all fixing arrangement of capacity 1.5 TR all as specified and directed Make of AC Hitachi/Blue Star/ Carrier/Diakin/LG/Voltas
SUKU CONSTRUCTIONS
ST ANTONY CONSTRUCTIONS
M.J.JOY AND COMPANY
KENZ CONSTRUCTIONS
M/S AARJAY ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .