Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.5 L+₹5.7 L (13.8%)Rejected-Finance WEST OTHIYA P O THIRUVALLA 689551 | PATHANAMTHITTA | KERALA | 689551 | L2 | Rejected-Finance L2 |
Tender Value
₹43.0 L
EMD Value
₹50,000
Closing Date
12 Sept 2018, 5:00 pmClosed
SENIOR MANAGER(CD)
SENIOR MANAGER(CD) SILK ATHANI THRISSUR
Supply and Installation of High Mast Light AND MINI Mast Light at Aluva LAC.
2018_SILK_230038_1
SILK/45/CD/281/2018-19/1048
Limited
Electrical Works
Item Rate
90 days
Aluva
As per tender details
5 documents required · 5 mandatory
₹2,950
online
₹50,000
Yes
17 Jan 2022
27 Aug 2018
15 Sept 2018
27 Aug 2018
12 Sept 2018
27 Aug 2018
27 Aug 2018 - 12 Sept 2018
Amount
Supply and Installation of 12 Mtr High Mast Light System with 6 Nos. of 200W LED Lights with 5 years warranty at Aluva Municipality, Choornikara GP, Nedumabassery GP and Chengamanad GP - Aluva LAC
(a) Supply 12Mtr High Mast system with its accessories . Mast shaft shall be in one or two section, Galvanisation of single hot dipped, suitable for wind velocity as per IS 875, Head frame assembly 2point suspention system with steel wire rope 5mm dia (7/19 construction) and double drum winching system arrangement conforming to IS with galvanised lantern carriage suitable for accommodating 6nos flood light luminaires symmetrically and its control gear box and lightining spike. The mast shall have an integral 3 phase operation power tool installed inside the base compartment for its operation.(Bajaj/Equivalent), (b Supply and conveyance foundation bolt made of special steel along with nuts, washers, anchor plates and templates. (c) Supply, errection, testing and commissioning of LED aviation obstruction light. (d) Supply and errection control box consists of :6-25A 4pole MCB incomer, 25A 4pole RCCB, single dial 24 hour timer with charging facility and contactor for automatic operation, and suitable size conection cable from control panel to flood light fittings . it shall also consists of suitable control for power tool three phase motor and giving connection.(e)Construction of suitable shallow foundation with 1:2:4 Concrete for the high mast considering the safe soil bearing capacity at site as 10 T/Sqmtr at 2 Meter depth with reiforcement for RCC works,bend tied and placed in position (plain grill requiring bend cold ) using for steel including form work for reinforced cement concrete and excavation of soil including neat banking. (f) Erection and commissioning of the above high mast with the help of crane/derrick and other suitable equipment and wiring of luminaries with wiring materials.
supply,installation,testing and commissioning of 200W LED flood light luminair with extruded aluminium heat sink pressure die cast aluminium cover on both side for holding of extruded aluminium heat sink and with voltage range ( 140 - 270V AC). The luminair shall be minimum IP 66 Protected. LED Driver efficiency should be greater than 105 % with colour temperature should be greater than 5700K range. Inbuilt-surge protection 10kv and power factor 0.95 with THD less than 10%.
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the 4 core 6 sq mm sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 6 sq mm
Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 50 / 38 mm or nearest size
Supplying siemens / tropodur type nickel plated Single compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the 6 sq mm sizes as required.
Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the 6 sq mm with 12 mm wide x 1 mm thick clip sizes of cables as required.
Supply of superior quality aluminium tubular cable socket and making core termination of cables of the 6 sq mm sizes including crimping etc. as required.
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in hard soil)
Supply and providing the 300 x 300 x 6 mm cast iron gully trap with covering sizes of cast iron gully trap with covering at the top of of the inspection chamber of earth pit as required.
Supply and providing test joint for the earthing system using 2 Nos of the 2 x 25 x 3 mm GI strip sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required.
Supply and providing earth lead from the test joint to the earth electrode using the 25 x 3 mm GI strip sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
Supply and drawing bare earthing conductors of the 3.15 mm copper conductor (10 SWG) sizes along with wiring/ cables and giving connection as required.
--------Do---------2.65 mm copper conductor (12 SWG)
supply of superior quality copper earth socket for the 3.15 mm (10 SWG)sizes of earth conductor including crimping etc. as required.
Supply and laying the 25 x 3 mm GI strip sizes of strips laid 0.60 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).
Supply and laying strips of the 25 x 3 mm GI strip sizes along with wiring/ cables and giving connection as required.
Supply and providing the 25 x 6 mm GI bolt & nut sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
--------Do----------25 x 8 mm GI bolt & nut
Supply and wiring with 4.00 sq mm single run without sockets. 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size sockets at the termination points, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
Aluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
Supply and clamping the following sizes of "B" class GI pipe on wall with all required accessories & clamps etc., including cutting and making good the walls, painting the exposed portions etc., as protective covering to earth leads / cables. 40 mm dia (for service)
Earth work excavation in ordinary soil and depositing with a lead up to 50 m and lift up to 1.50 m including neat banking
Brick work in cement mortar 1:6 with country burnt bricks 19cm x 9cm x 9cm for foundation and basement.
Plain cement concrete 1:4:8 using 40mm ( Normal size ) broken stone. ( m3 )
Plastering with cement mortar 1:4, 12mm thick one coat.
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of folowing size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. 600x300x214mm
Fabrication, supply, conveyance & installation of angle iron frame work for wall mounting panel board using suitable size angle iron cut and welded to shape including painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel using required bolts and nuts, fixing the whole to the wall, making good the damagesetc as required.
Supply and providing 32 A, 415 V Backelite fuse fitting
16 A, clip-on offset tag fuse link of size f1
32 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
6 A to 25 A, 10 kA, 4 pole MCB (C curve)
Fabrication ,supply and conveyance and installation of name board by using a plaque granite carrying the inscription "MPLAD Works" indicating the cost involved, the commencement, completion and inauguration date the name of MP sponsoring the project and name of the institution should be permanantly and prominently, erected in granite by using required bolt nad nuts as required. ( Actual Amount paid on production of recipt)
KSEB Charges ( Actual Amount paid on production of recipt)
Supply and installation of 8Mtr Mini Mast light System with 4 nos. 150 W LED Lights and 5 years warranty at 13th Ward Marvaar Junction in Aluva Municipality - Aluva LAC
Supply and erection of octoganal galvanized pole 8 mtr height complete with 4 Nos foundation bolt suitable size base plate , space for mounting control switch box with inspection type door at a height of 500mm from the base plate including Bakelite sheet with 6A SP MCB (4Nos) with suitable Stud terminals etc as required
Earth work excavation in hard soil and depositing with a lead up to 50 m and lift up to 1.50 m including neat banking for foundation earth work(2.6.1)
RCCM20 using 20mm (nominal size) broken stone forFoundation and Column footing (5.1.2) as per drawing
Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel 5.22.6
Form work for reinforced cement concrete in slabs including wooden planks, joists, bamboo posts and labour for taking down after completion of work (Hire and labour charges only)
Supply, conveyance, installation, testing and commissioning of LED 150W flood light fitting with all acessories . Luminaire housing component to be alluminium alloy with black powder paint IP 67. Internal surge protection against lightening or any other electrical surge up to 8 KV. .input voltage range 100-240+- l0%,power factor > 90% at full load, ROHS compliance
Supply and drawing the following sizes of multi-core PVC insulated & PVC sheathed 650/1100 v grade 3 core copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessarv connections of the following sizes.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 1.60 mm CRCA sheet as per approved design and requirement, with front and rearaccess facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, painting the assembly with 2 coats synthetic enamel paint over a coat of zinc chromate primer etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the abrication of panel assembly. The measurments should be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. including control wiring
Fabrication, supply, conveyance and installation of angle iron frame work for wall mounting panel board using suitable size angle iron cut and welded to shape including painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel using required bolt and nuts, fixing the whole to the wall, making good the damages etc. as required.
Supply and fixing the following types of beeding along the periphery of doors/ other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue
U' section rubber beeding suitable for 1.60/ 2.00 mm sheet
Supply and fixing the following accessories in the existing meter board and giving connections etc.
32 A fuse holder for BS type blade fuses.
32 A,415V , 2 way neutral link mounted on DMC/ SMC base
20-25 A, clip-on offset tag fuse link of size fl
Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required
25 A,2 pole, 30 mA RCCB
6 Ato25 A, l0 kA, DP MCB (C curve)
32A,2Pole, AC I rated power contractor with lNO+lNC auxiliary contracts & with AC coil
24 Hours Timer for operating automatic ON-OFF function
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required
25 mm dia light gauge
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate,20 mm GI watering pipe fixed to the earth plate with 20 x3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of l:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar l:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)
Supply and providing the following sizes of cast iron gully trap with covering at the top of the inspection chamber of earth pit as required
300 x 300 x 6 mm cast iron gully rrap with covering
Supply and providing test joint for the earthing system using 2nos of the following sizes of strips including cuttings and bending to shape. Drilling necessary,holes and frxed to the watering pipe etc as required.
2x25 x 3 mm GI strip
Supply and providing earth lead from the test joint to the earth electrod eusing the following sizes of conductors/ strips including cutting, drilling ecessary holes (in case of strip) and fixing firmly with plate test joint etc as required.
25 x 3 mm GI ship
Supply and drawing bare earthing conductors of the following sizes along With wiring/ cables and giving connection as required.
3. 15 mm copper conductor ( 10 SWG)
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required.
3.15 mm (10 SWG)
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required.
25 x 3mm brass bolt & nut
Supply and wiring with 650,/1 100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size sockets at the termination points, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
4.00 sq mm single run without sockets. (for terminating KSEB meter Board)
Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt).
Fabrication ,supply and conveyance and installation of name board indicating the cost involved, the commencement, completion and inauguration date etc.
J N LIGHTINGS (KERALA)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_305737.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .