Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC 17 NO TIKIA MAHAL ORDERLY BAZAR PO PS BARRACKPORE DIST 24 PGS KOLKATA 700120 WB | KOLKATA | 24 PGS | WB | 700120 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹40.0 L+₹1.9 L (4.95%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹40.0 L+₹1.9 L (5.06%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹40.3 L+₹2.2 L (5.68%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹41.5 L+₹3.4 L (8.88%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹36.2 L
EMD Value
₹72,400
Closing Date
10 Sept 2022, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
PROVN OF FENCE, GATE AND HARDSTANDING NEAR BLDG NO.NP-61, FALSE CEILING , ENTRANCE GATE, INTERLOCKING TILES, TOILET BLOCK, PATH WAY VEH CYCLE SCOOTER PARKING SHED AT KANCHRAPARA UNDER GE BARRACKPORE
2022_MES_546611_1
8689/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹72,400
Yes
17 Sept 2022
20 Aug 2022
12 Sept 2022
20 Aug 2022
10 Sept 2022
3 Sept 2022
Amount
PART-I Surface dressing in soft /loose soil not exceeding 15 cm deep complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed.
Excavating in dense soil as in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for not exceeding 10 sqm on plan in any type of soil complete all as specified and directed.
Excavating in dense soil as in trenches not exceeding 1.5m wide and not exceeding 3m depth for foundation etc or for not exceeding 10 sqm on plan in any type of soil complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm, soil complete all as specified and directed.
Spreading, levelling and ramming including watering in floors etc layers not exceeding 25 cm thick (material obtained from excavated materials) complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for broken brick hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete for embedding of post complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in roof kerbs or mud stops, top of chajjas, coping, bed plates etc rounded or chamfered on edges including necessary form work complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) as in foundations including rafts, footings, foundation beam, plinth beams, bases for columns etc , basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) as in column, pillar, piers, post and struts etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type A1 (using 20mm graded crushed stone aggregates) as in chajjas complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) used as in bed block, hold fast, coping, door cills and like etc including necessary form work complete all as specified and directed.
M&L for pre-cast cement concrete block masonry with solid blocks type C1 (using 20mm graded stone aggregate), exceeding 10 cm in width and setting in mortar complete all as specified and directed.
M&L for cutting chases, in brick wall, pinning in and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good the disturbed surface, cutting not exceeding 10cm girth complete all as specified and directed.
M&L for cutting holes into or though brick walls in cement mortar or stone walls built in cement mortar to a depth of embedded portion exceeding half brick but not exceeding one brick for inserting holdfasts and making good dismantled portion in cement concrete (1:2:4) Type B-1 as required complete all as specified and directed.
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks locally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
Providing form work to sides of concrete foundation, footing, base of column, raft & plinth beam for flat, rough finish surface of concrete complete all as specified and directed.
Providing form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
Providing form work to sides of pillar, posts, struts, piers, columns and stanchions for flat, rough finish surface of concrete complete all as specified and directed.
Providing formwork to chullah hoods, chajjas, troughs and similar items including edges for flat, rough finish surface of concrete complete all as specified and directed.
Providing formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs exceeding 5 cm but not exceeding 10 cm wide for rough finished surfaces of concrete, flat complete all as specified and directed.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
S&F of second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints etc complete all as specified and directed.
S&F of 35mm thick plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F of factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing as mentioned in SSR Part-II (2020), Section 8, Page No. 178 complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification & drawing as mentioned in SSR Part-II (2020), Section 8, Page No.174 complete all as specified and directed.
S&F for 300 mm aluminum alloy, anodised, sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F of 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F for 75 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F of rolled mild steel roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe-410W (Gde E-250) quality 'B' complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 5cm but not exceeding 10cm long with dia of neck 11 to 15 mm complete all as specified and directed.
S&F for bands, straps, supports or stays for rainwater, ventilating pipes including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fast, wind ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-e-165 complete all as specified and directed.
M&L for mild steel structural steel work including tubular members conforming to Fe-410-S as in roof trusses (framed), struts, trussed purlins of beam, tee angle, channel, tubes section including distance pieces cleats etc and cutting to dead ends, notching, drilling, fittings, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fittings angle cleats, fish plate, gussets plates etc also for wedging turning up and fixing complete all as specified and directed.
S&F of mild steel work, flat iron as in fencing post support conforming fo Fe-290-Gde-E-165 complete all as spcrified and directed.
Supply only MS round bars 10mm dia for securing chain link fencing fixed to RCC fencing posts as per Fe-410-W (Gde- E-250) quality 'A' or Fe-290 (Gde E-165) complete all as spcrified and directed.
Supply only galvanised iron chain link fencing with 4 mm dia of wire made up into matresses with mesh of size 100mmX100mm and type and fixed with 10 mm dia MS round bars and straining including provision of binding wire for securing chain link fencing as per relevant IS specification and as approved complete all as specified and directed. (Note: 10 mm dia MS round bar shall be measured and paid separately under Item No. as "supply only")
Fixing only galvanised iron chain link fencing with 4 mm dia of wire made up into matresses with mesh of size 100mmX100mm and type and fixed with 10 mm dia MS round bars and straining including provision of binding wire for securing chain link fencing as per relevant IS specification and as approved complete all as specified and directed. (Note: 10 mm dia MS round bar shall be measured and paid separately under Item No. as "supply only")
S&F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings & straining & fixing to any type of standard rails straining bolts, including, securing or tying at crossings with & provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (Note: Each line of wire to be measured).
S&F of steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed.
S&F of steel windows with side hung shutters (glazed) including projection type hinges with steel handle, frame, steel peg stay, complete with glazing bars, dovetailed or welded to receive glass, including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F of pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge / wall/cladding, fixed with self tapping screws complete all as specified and directed.
S&F of false ceiling with exposed metal (PPGI) framework/ “Tee” Grid providing and fixing of suspended Tee grid false ceiling using “T” Grid System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 6mm thick non asbestos fibre cement board of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T grid Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Grid module to form complete all as specified and directed.
S&F for mild steel works for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in subbase floor complete all as specified and directed.
M&L for 50mm thick PCC (1:2:4) type B2 (using 40mm graded crushed stone aggregate), as in floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate), as in sub base to floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 450 mmX 350 mmX7 mm thick or equivalent set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:3) complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 15 mm thick cement screed bed in cement mortar (1:4) complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-35 grade) laying over and including 50mm thick sand filling complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on other than fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of roof with cement mortar (1:4) mixing with mixed with WPC @200ml per 50 Kg of cement or as per manufacturer's instructions , finished the surfaces even & smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
M&L for applying three coats of white wash on surface of ceiling, chajja including preparation of new plastered surface complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkaline resistant primer after preparation of newly plastered surfaces of ceiling complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over and including a coat of red oxide primer after preparation of new steel surfaces of any description not exceeding 10 cm width or girth complete all as specified and directed.
S&F of 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F of 4mm thick figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane complete all as specified and directed.
S&F of 15mm dia bib tap, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F of 15 mm bore stop valve, fancy type, chromium plated, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F of 15mm dia pillar tap, fancy tpype, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
S&F of 15 mm dia PVC connection pipe of length 600 mm with PTMT nuts complete all as specified and directed.
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F of 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed (minimum weight 210 gms) complete all as specified and directed.
S&F of 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer), ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection all as specified in SSR Part-I complete all as specified and directed.
S&F of vitreous china urinal half stall type, including CP coupling, waste pipe and all necessary fittings, complete including providing and fixing plug, bedding urinal against wall in CM (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
S&F of vitreous china wash basin, white, flat back, size 550 X 400 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand acomplete all as specified and directed.
S&F of 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia suitable for low level cistern fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F of vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:4:8) type D2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floor complete all as specified and directed.
S&F of 32mm waste coupling of PTMT (half and full threaded) (minimum weight 45gms) completed all as per specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (single T) equal or unequal providing with access door complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (single T) equal or unequal complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (double T) equal or unequal complete all as specified and directed.
S&F for 110mm bore PVC(SWR) junction single, (double T) equal or unequal providing with access door complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe 100 mm bore including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and directed.
S&F of 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB, urinal etc. complete all as specified and directed.
M&L for 100mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
PART-II M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as sunken box, top cover , blank plate, MS box, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch .
One ceiling fan/exhaust fan point controlled by one switch .
One 3 pin 5 amps socket point controlled by one 6 amps switch on same board .
Ditto-all as per Item No.109.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of 3 pin, 15/16 Amps socket outlet on independent board complete all as specified and directed .
S&F of angle lamp holder, insulated body with back plate for batten fittings complete all as specified and directed.
S&F of ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed.
S&F of switch piano flush button single pole, one way, 5/6 amp, 240 volts, AC, ISI marked complete all as specified and directed.
S&F of switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC/Rashmi Cat No. RLTU20TLT8 as approved for LED lamp or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
S&F of 36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED/Philips Cat No. BRP052 LED 036 CW HP SLAF G SI PSU GR or equivalent model/Cat No of make as per Appx 'A' as mentioned in PS here-in-after)
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 40 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F of MCB SPN 32 Amps, 10 KA, 'C' series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed.
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
M&L for earthing with glavanised steel earth plate electrode of size 60cmX60cmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick complete all as specified and directed. (Note: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
S&F of heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed. (Note: Only punned down volume of sand to be measured)
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for boring holes horizontally under road without damaging the surface of road (minimum 1.0m bellow the road surfaces) with the help of GI tubing of any dia not exceeding 100mm dia for passing of UG cable complete all as specified and directed.
S&F of sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 4 way with 200 amps rated busbar, 240 volts, as per IS-8623 complete all as specified and directed.
M&L for fabrication and installation of aluminium composite panel cladding (ACP) with MS frame of any description suitable for day/night sign boards (cubical structure) as per site requirement complete all as specified and directed. (Note: Necessary MS pipe/MS channel work including painting required for fabrication of cubical board is deemed to be included in quoted rate)
M&L for fabrication and fittings of acrylic raising letters including LED fixed on ACP board at a height not exceeding 30 feet from normal ground level and letter size not less than 12 inch complete all as specified and directed (Front side- "WELCOME TO MIL STN KANCHRAPARA", Back side-"THANK YOU VISIT AGAIN")
PIONEER TRADING
R N CHATTERJEE
Kiran Traders
M/S. ARUP KUMAR DEY
SMART CONSTRUCTION
SHANKAR CONSTRUCTION CO
KOLAY CONSTRUCTION
S..S. ELECTRIC CO.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .