| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹41.1 L+₹2.1 L (5.46%)Rejected-AOC 31 SARASWATI SONI MARG DEHRADUN | DEHRADUN | L2 | Rejected-AOC Rejected | |
| 3 | L3₹43.8 L+₹4.8 L (12.2%)Rejected-AOC 121 MODEL TOWN AMBALA CITY HRY | AMBALA CITY | AMBALA | HARYANA | 134003 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹47.3 L+₹8.3 L (21.2%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹52.0 L+₹13.0 L (33.3%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
7 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Project Dehradun
GE Project Mall Road Dehradun (UK) -248003
PROVISION OF COVERED PASSAGE FOR CARIAPPA BATTALION FOR THREE COYS FROM COY PREMISES TO RESPECTIVE COY ANTE ROOM AT IMA DEHRADUN
2021_MES_435403_1
PROVISION OF COVERED PASSAGE FOR CARIAPPA BATTALIO
Open Tender
Civil Works
Item Rate
270 days
Dehradun Cantt
Class E
Category a(i)
8 documents required · 8 mandatory
₹500
GE Project Dehradun
₹88,000
Yes
14 Jun 2021
9 Apr 2021
10 May 2021
9 Apr 2021
7 May 2021
24 Apr 2021
60 days
Amount
Rough excavation by mechanical means (Hydraulic excavator) not exceeding 15 cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavating in trenches by mechanical means (Hydraulic excavator) n'exc 1.5 m width and n'exc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable etc n'exc 10 sqm on plan and n'exc 1.5 m in depth and getting out in all kind of soil complete all as specified and directed.
Returning, filling in, by mechanical means (Hydraulic excavator) including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.
Removal of surplus spoil, by mechanical means (Hydraulic excavator/ dumper / tractor-trolly) to a distance n'exc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Removing excavated material, by mechanical means (Hydraulic excavator/dumper/ tractor-trolly) to a distance exc 1.5Km but n.exc 5.0 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for PCC (1:4:8) Type D2 (40 mm graded aggre-gate) as in foundations, filling and mass-concrete complete all as specified and directed.
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles, raft etc and mass concrete complete all as specified and directed.
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in floor/ roof beam, cantilevers, lintel over 1.5m span complete all as specified and directed.
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves complete all as specified and directed.
M&L for RCC (design mix) M-25 (using 20mm graded stone aggregates) as in arches (Chajja) complete all as specified and directed.
M&L for formwork for rough finish to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L for formwork for rough finish to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
M&L for formwork for rough finish to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
M&L for formwork for rough finish to soffits of suspended slabs such as roof slabs, floor slabs, landing slab and similar work, not exceeding 200mm thick complete all as specified and directed.
M&L for formwork for rough finish to edge of concrete flats exc 10 cm but n'exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or slopping and similar work, complete all as specified and directed.
M&L for formwork for rough finish to sides and soffits of flat surface of arches (Chajja) etc complete all as specified and directed.
M&L for mild steel TMT bars as in reinforcement, 10mm dia and over cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 5 to 10mm dia bars as in stirrups cut to length, bent to shape required including cranking, bending hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for brick work with old size full brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed.
Supply only WPC integral water proofing compound (Liquid type) complete all as specified and directed.
M&L for hardcore of broken boulders/stone of gauge n exc. 63 mm, deposited, spreading, leveling watering and well ramming to true surface in layers not exceeding 15 cm thick each layer complete all as specified and directed.
M&L for 75 mm thick PCC (1:2:4) type B2, (40 mm graded stone agg) as in sub base of floor complete all as specified and directed.
M&L for 15mm thick plastering on fair faces of brick wall in CM (1:4) mixed with water proofing compound (liquid type) @ 200ml per 50Kg of cement surface finished even and fair complete all as specified and directed.
M&L for 10mm thick rendering on other than fair faces of brick work or concrete surface in cement plaster (1:6) finished the surface even and fair complete all as specified and directed.
M&L for 5mm thick rendering on fair faces surface in cement plaster (1:3) as in ceiling and fininshed surface even and fair complete all as specified and directed.
M&L for preparation of newly plastered surfaces on wall and apply 1mm thick of Birla/ JK wall care putty for smooth finish of wall complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper on prepared plastered surfaces of walls complete all as specified and directed.
M&L for applying two coats of exterior emulsion paint (Apex from Asian Paint or equivalent make as specified) over a coat of primer as recommended by manufacturer of paint on prepared surface of brick (plastered or un-plastered) or concrete surface complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed.
M&L for 10mm thick screed bed or bedding layer in CM (1:3) mixed with water proofing compound (liquid type) @ 200ml per 50Kg of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed. Note :- WPC (liquid type) shall be measured and paid separately as supply only.
M&L for roof treatment with APP based polymeric membrane, 3mm thick (minimum), weighting 3.5 Kg/Sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over and including applying one coat of hot blown bitumin grade 85/25 confirming to IS-702 @ 1.2 kg per Sqm over a coat of bituminous primer @ 0.3 litre per sqm surface, application of APP modified membrane shall be by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. One coat of aluminum paint @0.10 Kg/Sqm over the APP Modified Membrane shall be provided complete all as specified and directed.
M&L for louvres and jallies of precast cement concrete (1:2:4) type B0 (12.5mm graded aggregate), measured solid, including all mouldings set in CM (1:4) of following size complete all as specified and directed:-
25mm thick
M&L for 20mm thick "Makarana White" marble slab (size-8'x4' or as required at site and approved by GE) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of marble stone including grinding and mirror polishing to the entire satisfaction of GE complete, bedded over and including 20mm thick screed bed in CM (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble complete all as specified and directed.
M&L for point wiring complete with multi stranded copper conductor 1.5 Sqmm size (Nominal area) FRLS-H PVC insulated unsheathed cable conforming to IS : 694 and ISI marked in and including concealed PVC conduit medium grade, ISI marked not less than 20mm dia with concealed sunk in galvanized pressed steel terminal boxes 1.2 mm thick of required size factory made with top cover 3mm thick plastic laminated sheet, of required colour fixed with steel screws and cup washer including 1.50 Sqmm multi stranded copper conductor FRLS-H PVC insulated unsheathed cable of a green colour as a earth wire connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, complete with all accessories all as specified and directed for followings :- Note :- Cutting chases & making good the disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rate.
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
S&F switch piano, flush button type 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Anchor Cat Part No- 95111/ 14111 or equivalent of makes as specified.
S&F ceiling rose surface type of size 65 x 50mm three terminals, PVC poly corbonate, isolated body complete all as specified and directed. Make – Anchor Jumbo Code-39050 / 3224 or equivalent make as specified.
S&F surface and wall mounted high performance extruded aluminium housing, LED battens with white acrylic cover and end decorative covers suitable for LED tube light fittings 20 watt, 240 volts, 50 Hz, having suitable size drivers and all other connected accessories internally pre-wired with 2 x PVC round / square block for fixing of fittings and connecting to ceiling rose with suitable size of flexible copper cable two core of required length and 20 watt LED lamp of white / natural white colours compete all as specified and directed. Make : Philips, Cat Part No. (For Batten) - TMC100 1xTLED 13-20w WH and Cat Part No. (For LED Tube) - MAS LEDtube 1200mm 18W865 T8 I , Make : Havells, Cat Part No. (For Batten) - REGALBATTENT8UPTO1X22WSSBSWH and Cat Part No. (For LED Tube) - PHOTONULTRAE2.01213T8SSTL18WLED865SPC or equivalent make as specified.
S&F connecting & testing MCB, 'B' series 230V with rupturing capacity 10 KA of following capacity complete all as specified and directed:-
MCB 6 to 32Amp, SP. Make :- Legrand, Cat Part No 4085 87, 4085 90, 4085 92 to 4085 95 or equivalent others make as specified.
M/s RP AGRAWAL
Laxmi Builders
M/S C S AITHANI
Som Prakash Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .