Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance VILLAGE THAROT PO CHARRI TEHSIL SHAHPUR DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 176001 | ₹2.0 L | L1 | Accepted-Finance Due to lowest rate |
| 2 | L2₹2.1 LRejected-Finance | ₹2.1 L | L2 | Rejected-Finance Due to highest rate |
| 3 | L3₹2.1 LRejected-Finance DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 176001 | ₹2.1 L | L3 | Rejected-Finance Due to highest rate |
| Sl No | Description | Qty | Unit | SUMMY SHARMA L2 | SANJAY KUMAR L3 | PUNIT KUMAR L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in foundation trenches etc. in earth work in all kinds of soil such as pick work, jumper work, blasting work soft /hard rock, chiesling soft /hard rock where blasting is prohibited, slushy, daldal and saturated soil I/c pumping or bailling out water with in all heights stacking the excavated soil with 15cm layer when required into plinth ,sides of foundations etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus earth as per direction of Engineer-in-Charge with in all leads and lifts . | 49.2 | Cum | 300 ₹14,760 | 290 ₹14,268 | 280 ₹13,776 |
| 2.00Dismantalling of old GI Flanged pipe of following dia including stacking the dismentalled pipes at required place( earth work to be measured and paid for separately) within all leads and lifts. 65 mm Dia | ||||||
| 2.01 | 80 mm Dia | 270 | Rmts. | 80 ₹21,600 | 92 ₹24,840 | 90 ₹24,300 |
| 2.02 | 125 mm Dia | 200 | Rmts. | 150 ₹30,000 | 130 ₹26,000 | 130 ₹26,000 |
| 3.00Re- Laying jointing and testing of bevlled ended G.I. pipe 100 mm dia table-5 with circumfernital butt welded joints every two joints (94%) by electrical are welding thincless shall be equal to pipe wall thinckes)and testing of G.I. pipe including flange and bends confirming to ISI 1239-1990 (part-III) having wall thinckess as specfic below capable of with standing required test pressure including manufacturing and fabrication of reducers/tapers all short pieces etc. as per site requirement made from parent tubes the laying of pipe shall also providing MS flanged of required table including welding of flanges of every third pipe (6%) duly welded including nuts. complete within all leads and lifts. | ||||||
| 3.01 | 80 mm Dia | 270 | Rmts. | 130 ₹35,100 | 130 ₹35,100 | 125 ₹33,750 |
| 3.02 | 125 mm Dia | 200 | Rmts. | 180 ₹36,000 | 220 ₹44,000 | 200 ₹40,000 |
| 4.00Providing, fixing, MS flanges confirming to IS-6392-1971 (Latest with upto date ammendments) of class /Table -5 specified welding both sides of flanges according to relevant standereds i/c nuts bolts and rubbur sheet washer confirming to IS 1367-1981 and carriage of material with in all leads and lifts. | ||||||
| 4.01 | 80 mm Dia | 15 | Pairs | 920 ₹13,800 | 920 ₹13,800 | 900 ₹13,500 |
| 4.02 | 125 mm Dia | 10 | Pairs | 1,300 ₹13,000 | 900 ₹9,000 | 1,250 ₹12,500 |
Tender Value
₹2.0 L
EMD Value
₹3,978
Closing Date
23 Mar 2026, 11:00 amClosed
Executive Engineer
Jal Shakti Division Shahpur
Restoration of rain damages of LWSS Bainthlu Kuthman in Tehsil Shahpur, Distt. Kangra, (HP)
2026_HPIPH_130937_1
EE/JSDS/NIT/2025-11140-89 dated- 09/03/2026
Open Tender
Civil Works
60 days
Shahpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Executive Engineer
₹3,978
9 Apr 2026
10 Mar 2026
23 Mar 2026
10 Mar 2026
23 Mar 2026
10 Mar 2026
10 Mar 2026 - 23 Mar 2026
Excavation in foundation trenches etc. in earth work in all kinds of soil such as pick work, jumper work, blasting work soft /hard rock, chiesling soft /hard rock where blasting is prohibited, slushy, daldal and saturated soil I/c pumping or bailling out water with in all heights stacking the excavated soil with 15cm layer when required into plinth ,sides of foundations etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus earth as per direction of Engineer-in-Charge with in all leads and lifts .
Dismantalling of old GI Flanged pipe of following dia including stacking the dismentalled pipes at required place( earth work to be measured and paid for separately) within all leads and lifts. 65 mm Dia
80 mm Dia
125 mm Dia
Re- Laying jointing and testing of bevlled ended G.I. pipe 100 mm dia table-5 with circumfernital butt welded joints every two joints (94%) by electrical are welding thincless shall be equal to pipe wall thinckes)and testing of G.I. pipe including flange and bends confirming to ISI 1239-1990 (part-III) having wall thinckess as specfic below capable of with standing required test pressure including manufacturing and fabrication of reducers/tapers all short pieces etc. as per site requirement made from parent tubes the laying of pipe shall also providing MS flanged of required table including welding of flanges of every third pipe (6%) duly welded including nuts. complete within all leads and lifts.
80 mm Dia
125 mm Dia
Providing, fixing, MS flanges confirming to IS-6392-1971 (Latest with upto date ammendments) of class /Table -5 specified welding both sides of flanges according to relevant standereds i/c nuts bolts and rubbur sheet washer confirming to IS 1367-1981 and carriage of material with in all leads and lifts.
80 mm Dia
125 mm Dia
Repair of leakage points by butt welding including excavation, cutting and welding of Risng main, Gravity mains and distributions pipe lines of following dia at site of work as per direction to make the joint leak proof with electric arc welding including digging of pits at leakage point i/c carriage of generator set at site complete within all leads and lift.
80 mm Dia
125 mm Dia
Laying jointing and testing of bevlled ended G.I. pipe 100 mm dia table-5 with circumfernital butt welded joints every two joints (94%) by electrical are welding thincless shall be equal to pipe wall thinckes)and testing of G.I. pipe including flange and bends confirming to ISI 1239-1990 (part-III) having wall thinckess as specfic below capable of with standing required test pressure including manufacturing and fabrication of reducers/tapers all short pieces etc. as per site requirement made from parent tubes the laying of pipe shall also providing MS flanged of required table including welding of flanges of every third pipe (6%) duly welded including nuts. complete within all leads and lifts. 80 mm Dia
Making connection of galvanised steel distribution with various dia of pipes by providing and fixing tee i/c cutting and threading of pipe complete within all leads and lifts. 80 mm to 100 mm dia
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_193606.pdf
techsummary_193606.pdf
finance_193606.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
Termsandconditions.pdf
Tender Documents • 0.28 MB
BOQ_193606.xls
BOQ • 0.23 MB
Form6and8.pdf
Tender Documents • 0.80 MB
Download all tender documents and submit your bid