Deputy Executive Engineer, Electric (R&B) Sub Division, Rajkot.
A&A to Ro Plant , Outdoor Light Fittings and Air Conditioner Machine in ITI Building at Upleta , Taluka: Upleta , Dist:Rajkot.
348469
No.12 of 2026-27
Open
Electrical Works
Works
Rajkot
9 documents required · 8 mandatory · 1 optional
₹600
Deputy Executive Engineer, Electric (R and B) Sub Division, Rajkot.
₹4,660
24 Sept 2026
24 Sept 2026
24 Sept 2026
1 Oct 2026
24 Sept 2026
Name of work: A&A to Ro Plant , Outdoor Light Fittings and Air Conditioner Machine in ITI Building at Upleta , Taluka: Upleta , Dist:Rajkot.
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
In Figures In Word
Qty. Unit estiamted
Replacing Old & u/s by Supplying & erecting 5 stage single
reverse osmosis water purification system with M.S. powder
coated frame, prefilter housing with 'O' ring presediment filter Rupees TwentyNine
GAC filter, carbon filter suitable buster DC pump capacity 80 Thousand One Hundred
psi, mention with 40 psi inline type post carbon filter auto low EightySeven Paise
& high pressure switches with following size of storage tank & NinetyNine Only
LPH capacity & erected as directed [C] 50 Ltr / Hr with
psi 2 nos booster pump
Replacing Old & u/s by Supplying and erecting Flexible PVC
insulated multi strand multi core 1.1 kV grade ISI marked Rupees FiftyEight Paise
copper wires of following size to be erected as directed.(e) 1.50 FiftyEight Only
Sq.mm 3 core round PVC sheathed
(h) 2.50 Sq.mm 3 core round PVC sheathed Rupees NinetySeven Paise
NinetySeven Only
Providing and erecting Approved make RCCBs conforming to
IS: 12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on
Rupees Two Thousand
phase and neutral 415V,50Hz. having characteristic of quick
3 2 Ea 2900.72 Nine Hundred Paise
action & tripping with all advance feature & do not incorporate
SeventyTwo Only
any electronic component for following Max. rating erected as
directed.(ii) 40Amps. FP Cat. III
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die
cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(B) LED Panel Light with provision for Plane front frame with Rupees One Thousand
translucent cover fixed to housing complete.IP20 (vi) 36 Seven Hundred
watts, 24" x 24", Surge- 2kV Cat-lll NinetyFour Paise
SeventySeven Only
Replacing Old & u/s by Supplying and erecting LED street
light / Flood light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
Rupees Nine Thousand
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to
5 8 Ea 9196.05 One Hundred NinetySix
5700K,Uniformity ratio >0.45, Luminaire efficacy>
Paise Five Only
lumens/watt . LED driver efficiency > 85 %.( fittings required
LM-79 & LM-80 certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between
the ranges shown.) (B) Flood Light (IP-65), Surge protection -
4kV integral and ,Light must have 440VAC line supply with
over-voltage protection. (vii) 200 - 250 watts Cat-lll
(A) Street Light (IP-65), Surge protection -4KV integral and
Rupees Four Thousand
,Light must have 440VAC line supply with over-voltage
9 Ea 4248.06 Two Hundred FourtyEight
protection. (ii) 48 - 59 Watts Cat-lll
Providing and erecting FRLS-XLPE (IS:7098)(I)-88 ISI
armoured cable multistrand / Solid Aluminium conductor for
Rupees One Hundred
6 120 Mtr. 1.1 kV. to be laid on wall with necessary clamps or in existing 151.50
FiftyOne Paise Fifty Only
trench / pipe of following size of cables (B) 4 core 6 Sq. mm
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
In Figures In Word
Qty. Unit estiamted
Supplying & erecting approved make SMC press moulded
composite FRP. loop-in, loop-out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E),DIN
Rupees Two Hundred
rail for mounting mob & hinged doors as per requirement
7 1 Ea 297.95 NinetySeven Paise
having locking arrangements with mounting clamp with nuts,
NinetyFive Only
bolts & washers suitable for erection on pole with cable
clamps& earth bolt of following size of box. (D) 140mm x
140mm x 100mm [deep]
Providing & erecting 240 V MCB double pole switch for
Rupees Three Hundred
motor & inductive load (C Curve) having 10 KA breaking
8 1 Ea 329.26 TwentyNine Paise
capacity & confirms to IS : 8828 in existing box having
following capacity (A) 6 to 32 Amp. Cat.III
Supplying & erecting approved make self-priming domestic
monoblock water pump with 1 H.P motor, suitable for Rupees Ten Thousand
operation on 230 volts, 50 Hz. AC supply with metallic flange, Seven Hundred
and M.S. impeller delivery and following discharge (b) 100 FourtyFour Paise
LPM at 14 mtrs. head suitable for 25 mm dia. delivery ThirtyEight Only
Replacing Old & u/s by Providing & erecting Approved make
Power Saving 45 - 50 Watt Ceiling Fan with double ball
Rupees One Thousand
bearing ISI mark with Condenser 230 volt A.C. 50 Hz
10 4 Ea 1948.29 Nine Hundred FourtyEight
mm sweep complete having 3blades with aluminium blades
Paise TwentyNine Only
with , canopy & 30 cm. down rod erected with earthing.(Make
shall be approved by Engineer in charge))
Replacing Old & u/s by Supplying and erecting LED indoor
fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled
on single MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high U.V. & corrosion
resistance with diffuser with company mark/name 160V to
270V, Power Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K, Rupees Five Hundred
11 8 Ea Luminaire efficacy> 85 lumens/watt ,LED 535.30 ThirtyFive Paise Thirty
LED driver efficiency > 85 % Only
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.) (A) Tube Light with integral
driver (v) 36-40 Watts, Surge-2 kV, IP-20, conventional 4 feet
Providing and erecting Inverter based approved make split air-
conditioning unit consisting of condensing unit with variable
speed fan motor, inverter type hermetically sealed rotary
compressor with accessories etc. duly connected separately
Rupees FourtyFive
erected evaporating unit and blower motor with its accessories
Thousand Eight Hundred
12 3 Ea by means of extra supplied proper insulated copper 45898.44
NinetyEight Paise
tubing,drain PVC pipes suitable for ( cost includes Eco
FourtyFour Only
Friendly green gas charging and 15A plug top & Remote
Control & MS Stand) with necessary core cutting. (1)For
ISEER Range (KWH/KWH)(3.1 to 3.99) (B) for 1.5 ton
(1)For ISEER Range (KWH/KWH)(3.1 to 3.99) (C) for 1.7 to Rupees FiftySix Thousand
2 ton capacity Eight Hundred
ThirtyThree Paise
SeventyOne Only
Supplying and erecting insulated pair of soft copper tubing
Rupees One Thousand
open or concealed including power and control cable,necessary
13 20 Rmt 1158.47 One Hundred FiftyEight
PVC drain pipes for Split/Cassette AC machine up to 4 TR
Paise FourtySeven Only
Item Quantities estimated Item of work Tendered Rate Total amount
Item Quantities estimated Item of work Tendered Rate Total amount
No. but may be more or according to
In Figures In Word
Qty. Unit estiamted
Supply and Erecting of Static Stabilizer suitable for following
capacity of A.C Machine the Stabilizer Must have Minimum
Technical Specification are Input working Single Phase
Voltage Range Up to 150V-280V.50Hz, Output Voltage Range
Up to 200V-240V,50Hz,Autoreset Facility,LED Display for Rupees Three Thousand
Indicating Voltage,Spike/Surge Protection,Time Delay Thirty Only
Facility,Proper Wall Mount Facility with Required Accessries
& on site 3 year Replacement/Repairing Warranty.
(1) For 1.5Ton Thermal Overload Protection 12 Amp.
(2) For 2 Ton Thermal Overload Protection 15 Amp. Rupees Four Thousand
TwentyNine Paise Ninety
Rupees Four Lakh SixtyFive Thousand Eight Hundred TwentyTwo Paise Ten Only
Note:- The Credit of dismentalled materials for Rs.2409.00 shall be recovered from the First R.A. bill payable to the contrator and there after the
dismentalled materials shall be the property of the contractor.
I/We am/are willing to carry out the work at__________________% above/below (in figures)_____________________________________percent Above / below (in
words) the estimated rates mentioned above amount of my\our tender works out as under :-
Estimated amount put to Tender Rs. _________
Deduct________% below Rs. _________
Net Amount Rs. _________
Estimated amount put to Tender Rs. _________
Net Amount Rs. _________
A I/We hereby declare that I/we have visited the site and fully acquainted my self / our selves with the local situation regarding material,labour and
other factors pertaining to the work before submitting this tender.
B I/We hereby declare that I/we carefully studied the conditions of contract, detailed technical specifications and other tender documents of this
work and agree to execute the same accordingly.
C Any Excess in Tender Item/Extra Item if Needs to be Execute. Contractors has to carry out work on the instruction of Competant Authority on
Tender Submitted rate,No Excuse will be Accepted.Hence Contractor are Requested to quote the rate considering this condition.
D Contractor are requested to quote the Tender by considering that payment will be made after availibility of grant.Contractor has to start the work
immediately after issue of Work Order and as per instruction of Engineer-in-Charge irrespective of availibility of grant.
E "This estimate has been prepared on the new SOR wich is exclusive of GST hence GST additional will be paid to the agency as per existing
(Signature of the Contractor) Deputy Executive Engineer
Electrical R&B Sub Division
Executive Engineer
Electrical R&B Division
Note 1 Please strike out whichever is not applicable.
2 In the case of tendered amount being quoted incorrectly the quoted pered percentage Below/Above will be considered as final.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Contractor_Registration_Paripatra__1_.pdf
GR for Extra Item.pdf
GR for single Tender.pdf
SD EMD GR 25-26.pdf
ONLINE_NOTICE(R-2).pdf
SBD.pdf
SCH-B.pdf
DM.pdf
ANNEXURE-A.pdf
MAKE FOR ELECTRICAL ITEM.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .