| 1 | 1₹5.6 LAccepted-AOC 2ND FLOOR COMMERCE CENTRE KULUR KAVOOR ROAD KULUR MANGALORE D K 575 013 | DAKSHINA KANNADA | KARNATAKA | 575013 | 1 | Accepted-AOC As per the price bids received and the BOQ comparative chart. | |
| 2 | 2₹6.6 L+₹1.0 L (17.9%)Rejected-AOC | 2 | Rejected-AOC As per the price bids received and the BOQ comparative chart. | |
| 3 | 3₹8.3 L+₹2.7 L (47.3%)Rejected-AOC | 3 | Rejected-AOC As per the price bids received and the BOQ comparative chart. | |
| 4 | 4₹10.0 L+₹4.3 L (76.8%)Rejected-AOC | 4 | Rejected-AOC As per the price bids received and the BOQ comparative chart. |
Tender Value
₹4.7 L
EMD Value
₹11,200
Closing Date
20 Jun 2019, 3:00 pmClosed
Superintending Engineer, Electricals, NMPT
New Mangalore Port Trust, Panambur, Mangalore, KA - 575010
Electrification work for installation of water coolers and for resting shelters at Port Operational area.
2019_NMPT_474537_1
3/ESDII/IV/SE (E)/2019
Open Tender
Electrical Works
Works
60 days
New Mangalore Port Trust, Panambur, Mangalore, KA
Please refer Tender documents.
3 documents required · 3 mandatory
₹560
Yes
FA and CAO, NMPT, Panambur, Mangalore
₹11,200
Yes
10 Jul 2020
1 Jun 2019
21 Jun 2019
1 Jun 2019
20 Jun 2019
1 Jun 2019
BOQ Particulars
Supplying of 3.5C X 25sq.mm LT, UG cable having Aluminum conductor PVC insulated , extruded inner sheathed , galvanized , steel strip confirming to IS-3975:1990 & extruded PVC outer sheathed armored cable with specified IS-1554 Part -1:1988 & confirming to GTP of GROUP –A.
Labor charges for laying of 3.5core x 25sq.mm armoured UG cable in existing trench GI pipe/Stone ware Pipe / Stoneware Pipe / on wall/ on pole as required. In existing trench/pipe.
Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCB’S three phase /double door with powder coated painting, Made out of 14SWG MS enclosure 4way TP&N, Double door.
Supplying and fixing 40Amps TPN on existing distribution boards using necessary fixing materials and ‘C’ Type curve, indicator ON/OFF, Energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
Supplying and fixing MCBs on existing distribution boards using necessary fixing materials and ‘C’ Type curve, indicator ON/OFF energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
a) 6 Amps SP
a) 16 Amps DP
Supplying and fixing earth electrode for grounding of light circuits, using 40mm dia., 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh and suitable –SBC reducer fixed on top of earth electrode. The funnel should be enclosed in CC chamber of 400x400x100mm with cast iron cover. The earth electrode shall have staggered holes of 12mm dia. And the electrode should be coved 150mm around pipe complete depth with alternate layers of salt and charcoal. The connection from the electrode is to be established through 25x3 copper flat using GI bolts and nuts.
Supplying and running 25x3mm copper strip for grounding connection using fixing materials as required.
Digging of trench of size 0.6 mtrs x 0.5 mtrs of laying of LT cable and refill the trench. In some places paver blocks, concrete & asphalt in cable route, whenever removed, re-fixed the paver blocks, re concrete/asphalt the road. Hard soil.
Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150 mm around the cable.
Supplying & laying of RCC semi cut pipe (C-CUT) in existing trench over the cable. Size: 150 mm dia, 25 mm thick.
Supplying heavy gauge PVC conduit pipe confirming to IS2509 with suitable size bends, metal/pvc junction boxes, adhesive paste etc. and running before concreting the slab. The conduit should be tied to the reinforcement rods by using bonding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosers, run with 18SWG GI fish wire wherever necessary.
a) 19 / 20 mm dia, 2 mm thick.
Wiring for lighting and power circuit using one of pvc insulated 1100V grade, multistrand copper conductor single core cable in casing and capping/conduit system of wiring.
a) 1.5 sq mm
b) 2.5 sq mm
Supplying and flush mounting powder coated/galvanized metal box suitable for fixing mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/cc wall.
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate, dummy plates with required nos of machine screws, bolts, nuts etc. complete on the existing pvc box.
Supplying and fixing of following modular type materials on existing modular switch plates.
a) 6 Amp Switch
b) 16 Amp Switch
c) 6 / 16 Amp Universal Socket
Fixing all types & all capacities of LED indoor fittings on the ceiling using approved make 23/0.0076” twin twisted PVC insulated wires with required no of round blocks and clamps using necessary length of GI chain.
Supplying BOX type LED Industrial light fittings- 4’x1x1, 6-20W with 1 nos 4’ LED light, lumen level output-1600-2100 and wattage-16-20W.
J C Electricals
Classic Electricals
Shantha Electricals and Engineers Pvt Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .