Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 CrAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹5.4 Cr | L1 | Accepted-AOC Being Lowest Tenderer |
| 2 | L2₹5.8 Cr+₹34.7 L (6.38%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹5.8 Cr+₹34.7 L (6.38%) | L2 | Rejected-Finance Being Not Lowest Tenderer |
| 3 | L3₹7.0 Cr+₹1.5 Cr (27.9%)Rejected-Finance KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹7.0 Cr+₹1.5 Cr (27.9%) | L3 | Rejected-Finance Being Not Lowest Tenderer |
| 4 | L4₹8.5 Cr+₹3.0 Cr (55.7%)Rejected-Finance 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹8.5 Cr+₹3.0 Cr (55.7%) | L4 | Rejected-Finance Being Not Lowest Tenderer |
| 5 | Rejected-Technical 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | - | - | Rejected-Technical Rejected, as your firm not enlisted in category c(vii) and not completed any similar work and therefore not qualified as per NIT |
Tender Value
₹4.4 Cr
EMD Value
₹5.1 L
Closing Date
8 Oct 2022, 6:00 pmClosed
CE (AF) Gandhinagar
CE (AF) Gandhinagar PIN-382042 c/o 56 APO
PROVISION OF SEWAGE TREATMENT PLANT AT AF STATION VADODARA
2022_MES_547616_1
89360
Open Tender
Civil Works
Lump-sum
1095 days
GE (AF) Baroda
As per NIT and Tender Documents
7 documents required · 7 mandatory
₹2,000
GE (AF) Baroda
₹5.1 L
Yes
16 Feb 2023
25 Aug 2022
10 Oct 2022
25 Aug 2022
8 Oct 2022
24 Sept 2022
29 Aug 2022 - 5 Sept 2022
Amount
NOTE: Schedule 'A' Part I to XIV are as under Ser No 1 to 14 are prepriced by MES. Bidders shall insert their lumpsum amount in the Green cloured field under Coln-6 only
Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A' Part I.
Lump sum price worked out for EXCAVATION/ EARTH WORK AND SITE CLEARANCE as listed in Sch 'A' Part II.
Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch 'A' Part III.
Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch 'A' Part IV.
Lump sum price worked out for ROAD/ CULVERTS/ HARD STANDING as listed in Sch 'A' Part V
Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch 'A' Part VI
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A' Part VII
Lump sum price worked out for SEWER NETWORK as listed in Sch 'A' Part VIII
Lump sum price worked out for SEWER NETWORK (ELECTRO -MECHANICAL EQUIPMENTS) as listed in Sch 'A' Part IX
Lump sum price worked out for RECYCLING OF TREATED SEWAGE as listed in Sch 'A' Part X
Lump sum price worked out for AREA DRAINAGE as listed in Sch 'A' Part XI
Lump sum price worked out for DG SET as listed in Sch 'A' Part XII
Lump sum price worked out for FENCING AND GATE as listed in Sch 'A' Part XIII
Lump sum price worked out for DEMOLITION AND DISMANTLING as listed in Sch 'A' Part XIV
SCHEDULE `A' PART-XV MISCELLANEOUS ITEMS (Note for items 15 to 51: The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
EXTERNAL ELECTRIFICATION
Shifting of transformer of 100 KVA capacity within 20-30KM area including loading and unloading by using crane and fixing at proposed STP site at Darjipura including testing complete all as specified and as directed. Note: (i) All required T&Ps, man power, vehicle for shifting of transformer any other material shall be provided by contractor and all rates shall be deemed to be included in quoted rate. (ii) Damaged/ broken parts during shifting shall be repaired and made functional by contractor without any extra cost. (iii) Disconnection and dismantling of transformer from existing site and refixing of HT/ LT connections at required place (New STP) as directed by Engr-in-charge shall be deemed to be included in quoted rates. (iv) Cost of PCC foundation of suitable size and earthing for transformer shall be measured and paid seperately.
Material and labour for transformer platform of size 2.5m x 2.5m x 1.5m height using brick work in CM 1:6, with PCC 1:4:8 type D-2 for foundation, 60cm below ground level, including 15 mm thick rendering in CM 1:4 on outer side of platform wall, mixed with water proofing compound, top of the platform in 30 cm thick PCC 1:2:4 type B1, including necessary earth work, form work and including two coats of white wash complete all as specified and as directed.
Supply and fix cable path indicator made of RCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) of size 0.2 m x 0.1 m x 0.75 m height, reinforced with 8 mm dia TMT bars 100 mm c/c horizontally and vertically, voltage and cable size mentioned in bold letters and painted with brown paint and background with two coats of yellow paint including PCC foundation 1:3:6 type C1 using 20 mm graded crushed stone aggregates, of size 0.3 m x 0.2 m x 0.1 m for each 50 meter distance, joints, turning points, crossings etc. including necessary exavation and earth work, removal compete all as specified and as directed.
Supply and fixing street light factory made thermoplastic cable junction boxes IP 66/67 "weather proof", with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 Sqmm with terminal consisting of 01 No. MCB 06 Amps, 10 KA capacity including aluminium strip bus bar for incoming and outgoing cable with necessary connection duly fixed on the pole with suitable size of MS clamps, nuts and bolts complete all as specified and directed.
Supply and fixing aesthetically designed LED security light luminaires of 60 Watts system wattage for energy saving having IP 66 degree of protection, with minimum system efficiency as>85%, made of pressure die casting aluminum housing powder coated in graphite grey and heat resistant toughened glass with excellent thermal management LED should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light, fitting should have operating voltage range of 120-270V AC, THD<10%, P.F>.95 with 10KV surge protection including GI pipe bracket length approx. 1200mm long bend to shape for fitting street light complete all as specified and directed. Make: Cat part No. ENDURAPEARLNEOSL60WLED757PASYTOPC of make Havells or Cat Part No LSFT-060-C of make Orient or equivalent in Polycab, Crompton etc. as specified
Supply, installation, testing and commissioning of cubicle type LT panel, outdoor type, factory fabricated, made out of CRCA sheet, CPRI approved mfd of 3.15 mm thick, fully enclosed and angle iron frame of size 40 x 40 x 6 mm thick and T section with front openable Double Door shutter, dust and vermin proof and rear opening complete with locking arrangement, having a system of bus bars of copper TPN 500 Amps conforming to IS :5082 duly insulated and mounted on epoxy/ porcelain insulators in totally enclosed chamber with 3 phase, 4 wire, 50 cycle, 415V, AC system pre-wired with suitable coper wire PVC insulated with all control accessories, duly painted internal externally with two coats of synthetic enamel paint of approved quality over a coat of red oxide primer on PCC 1:2:4 type B-1 platform 60 cm above the ground level including connecting the existing cables/earthings with the proposed LT panel with suitable size of thimbles, nuts, bolts and washer etc. suitable for enclosing the following items:
(a) Incoming: (i) MCCB 4 Pole 315 Amp 36 kA with electronic/ Microprocessor releases with overload zone of adjustment 0.4 to 1.0 In and electronic release with short circuit zone of adjustment 1.5 to 10.0 Ir (Adjusted current) with time incl extended Rotary Handle vari-depth type and spreader between phases and neutral - 01 No (ii) Change Over switch 315 Amp TPN-01 Nos (b) Outgoing: (iii) MCCB TP 250 Amp 36 kA with electronic/ Microprocessor releases with overload zone of adjustment 0.4 to 1.0 In and electronic release with short circuit zone of adjustment 1.5 to 10.0 Ir (Adjusted current) with time including extended Rotary Handle vari-depth type and spreader between phases and neutral - 02 No (iv) MCCB TP 100 Amp 25 kA with electronic/Microprocessor releases with overload zone of adjustment 0.4 to 1.0 In and electronic release with short circuit zone of adjustment 1.5 to 10.0 Ir (Adjusted current) with time incl extended Rotary Handle vari-depth type and spreader between phases and neutral -02 No (v) MCCB TP 63 Amp,16 kA with thermal magnetic adjustable relay including extended Rotary Handle vari-depth type and spreader between phases and neutral- 01 No (vi) Copper bus bar 3 phase, 4 wire 500 Amp rating. (vii) Hylem sheet, bridge insulator cable gland. (viii) Indicating lamp R,Y,B (ix) Digital type volt meter / Amp. meter (x) Digital frequency meter having range 0-50Hz-01 No (xi) Digital PF meter-01 No
SEWER NETWORK (ELECTRO-MECHANICAL EQUIPMENTS)
Supply, fixing, testing and commissioning of non-clog vertical submersible pumps single stage of 35 Cum/Hr flow rate capacity at 15 mtr head suitable for operation on 415 Volt 3 Phase squirrel cage, electric driven, copper wounded continuously rated motor ,class F insulation, water cooled with High chromium iron cutter, zinc free bronze impeller and suction cover CR-series, non-clog pump to pass 35 mm size particles including installation of guide rail fitting system and lifting chain, submersible cable PVC insulated of copper stranded conductor up to 10 mtr, for wet well complete all as specified and as directed.
Material and labour for DI fittings for spigot and socket pipes such as bends (any radius and any angle) tapers any type, straight, bend, increasing, decreasing or double socket etc. tee pieces, single branch, junction, double branch, cross, all sockets and spigot and socket caps, collars and plug upto 150 mm bore complete all as specified and as directed.
Supply, install, testing and commissioning of float type level switch (vertical) 220/230/250 Volts, IP 67 Float Switch Sensor for Water Level Controller with required length of wire for connection complete all as specified and directed.
Supply, install, testing and commissioning of pressure gauge range 0 -2.5 bar, 100 mm dia dial gauge, glycerine filled, MOC steel, bottom connection, 0.5' connection size for delivery line on pipe complete all as specified and as directed.
Supply, fixing, testing and commissioning of non-clog vertical submersible pumps single stage of 25 Cum/Hr flow rate capacity at 15 mtr head suitable for operation on 415 Volt 3 Phase squirrel cage, electric driven, copper wounded continuously rated motor, class F insulation, water cooled with high chromium iron cutter, zinc free bronze impeller and suction cover CR-series, non-clog pump to pass 35 mm size particles including installation of guide rail fitting system and lifting chain, submersible cable PVC insulated of copper stranded conductor up to 10 mtr, for wet well complete all as specified and as directed.
Supply, install, testing and commissioning of Twin-Lobe Roots Type Air Blower (Rotary compressor) of 300 cum/hr flow at 0.4 kg/sq. cm with 3 Ph, 415 Volt ( +/- 10 %) 50Hz electric driven motor, copper wounded, 12 HP capacity, TEFC, class F insulation with 1440 RPM with metal sheet enclosure, protection on rotating parts including PCC foundation of suitable size complete as per OEM recommendation for Blower room all as specified and as directed.
Supply and lay ductile iron pipe, flanged end, including rubber packing, nut, bolt and washers of suitable size, Class “K-7”, 100 mm (4") dia. for MBBR and equalization tank piping with all fittings complete all as specified and as directed.
Supply and lay ductile iron pipe, flanged end, including rubber packing, nut, bolt and washers of suitable size, Class “K-7”, 80 mm (3") dia. for MBBR and equalization tank piping with all fittings complete all as specified and as directed.
Supply, install, testing and commissioning of Fine Bubble EPDM Diffuser Dia 90mm x 1000 mm diffuser with 1 inch Air inlet connection and SS nipple EPDM membranes duly clamped for MBBR tank complete all as specified and as directed.
Supply, install, testing and commissioning of Coarse Bubble Wide band Diffusers Dia 90mm x 800 mm diffuser with 3/4 inch Air inlet connection and SS nipple for Equalization tank complete all as specified and as directed.
Supply, laying, spreading on MBBR media of PP with UV stabilized, with not less than dia 20mm and height 20mm for minimum surface area 500 m2/m3, loose media in bags complete all as specified and as directed.
Supply, install, testing and commissioning of pressure sand media filter of capacity 25 cum/hr flow, dimension 1.5 m dia and 2 m HOS capacity MS body, vertically fitted complete with all fittings, MOC of vessel FRP with sand media, Bypass valve, inlet/ outlet valve, PCC foundation as per manufacturer's recommendation etc. for near chlorine contact tank complete including back wash arrangement with necessary valves and fittings and pipings complete all as specified and as directed.
Supply, install, testing and commissioning of Activated Carbon Filter media of capacity 25 cum/hr flow, dimension 1.5 m dia and 2 m HOS capacity MS Body vertically fitted complete with all fittings MOC of vessel FRP with, Bypass valve, inlet/ outlet valve, PCC foundation as per manufacturer recommendation etc. for near chlorine contact tank complete including back wash arrangement with necessary valves and fittings and pipings complete all as specified and as directed.
Supply, install, testing and commissioning of pumping sets of capacity 12.5 Cum/hrs and 20 mtr head, centrifugal pump of CI impeller, electric driven motor, 415 Volt 3 phase, supply and install complete with PCC foundation of suitable size of filter feed pump near chlorine contact tank complete all as specified and as directed.
Supply, install, testing and commissioning of pumping sets of 5 cum/hr and 15 mtr head, submersible pump of bronze impellers, electric driven motor of 415 Volt 3 Phase, supply and install complete inclusive of sludge transfer pump of capacity near sludge tank complete all as specified and as directed.
Supply, install, testing and commissioning of Solenoid Operated Electronic Chlorine dosing pump upto 5 LPH, 120 SPM suitable for operation on 220Volt single phase AC supply with electric connection cable, PVC pipe connection of suitable size and delivery including strainer cum foot valve and anti syphon valve on suction pipe complete all as specified and as directed.
Supply install testing and commissioning of Solenoid Operated Electronic Poly dosing pump upto 5 LPH, 120 SPM suitable for operation on 220Volt single phase AC supply With Electric connection Cable ,PVC pipe connection of suitable size for suction and delivery incl Strainer cum foot valve &Anti Syphone Valve on suction pipe complete all as specified and as directed.
Supply, install, testing and commissioning of digital type dissolved oxigen analyzer with DIGITAL DO PROBE (With Breakthrough Luminescent Technology) suitable for operation on 100-240 V AC with one digital sensor input and two 4-20 mA outputs, PROBE, LDO MODEL 2, 10M HACH P/N: 9020000, SC200 CONTROLLER, 1 Channel AC-DC, DIGITAL, HACH MAKE P/N.: LXV404.99.00502 complete all as specified and as directed.
Supply and fixing of filter press with Electro Mechanical Plate Shifting Device Plates type Filter Press of sizes 1200 X 1200 mm for 7 bar filtration pressure with a hydraulic closing device, MOC of Filter Element: Polypropylene, Cast Iron, SS 304, SS 316 and Liquid Holding capacity - 55 Ltr complete all as specified and as directed.
Supply and fix Mechanical Aggitator of suitable RPM with gear box assembly and 3 ph 415 Volt AC motor totally enclosed, air cooled with weather protection cover complete all as specified and as directed.
Supply and laying/ fixing of tube settler media as per the requirement of the settlement tank/ MBBR tank capacity for removal of sludge and surface area shall be > 11 m2/ m3 made of PP/ PVC with plate inclination 60 degree with horizontal, minimum vertical height 750mm complete all as specified and directed.
Supply, installation, testing and commissioning of cubical type floor mounted LT panel board of CPRI approved manufacturer, indoor type factory fabricated made out of CRCA sheet of 2 mm thick, fully enclosed and angle iron frame of size 40 x 40 x 6 mm thick and T section with front openable Double Door shutter, dust and vermin proof and rear opening Semi Compartmentalized Cable Entry , Pre Treatment :7 Tank Process Painting: Powder Coated with Siemens grey (RAL-7032):TOP (detachable Gland plates) complete with locking arrangement, having a system of bus bars of copper 4Nos. 500 Amps conforming to IS :5082 duly insulated and mounted on epoxy/ Porcelain insulators in totally enclosed chamber with 3 phase, 4 wire, 50 cycle, 415V, AC system pre-wired with suitable coper wire PVC insulated with all control accessories, duly painted internally, externally with two coats of synthetic enamel paint of approved quality over a coat of red oxide primer on PCC 1:2:4 type B-1 platform 60 cm above the ground level including connecting the cables/ earthings with the proposed LT panel with suitable size of thimbles nuts, bolts and washer etc complete all as specified and as directed, suitable for enclosing the following items: Incoming: a) MCCB FP 250 Amp 36 kA with Electronic/Microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral - 01 Nos
Outgoing: (a) MCCB FP 63 Amp 10 kA with Electronic/Microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral - 05 Nos (b) MCCB 3 pole, 415 Volts, 40 Amp 10 kA with thermal /magneticadjustment relay - 08 Nos (c) MCCB 3 pole, 415 Volts, 32 Amp 10 kA with thermal /magneticadjustment relay - 08 Nos (d) Amper meter digital type- 01 Nos (e) Volt Meter digital type - 01 Nos (f) Indicator lamp (RYB) set of three - 01 set (g) Soft Starter 3 Ph suitable for 35cum/Hrs 15 mtr head sub pump -03 Nos (h) Soft Starter 3 Ph suitable for 25cum/Hrs 15 mtr head sub pump -02 Nos (j) Soft Starter 3 Ph suitable for 12 HP air blower -03 Nos (k) Soft Starter 3 Ph suitable for 12.5 cum/Hrs 20 mtr head centrifugal pump -03 Nos (l) Soft Starter 3 Ph suitable for 5 cum/Hrs 15 mtr head sub pump -02 Nos
RECYCLING OF TREATED SEWAGE
Supply and fix 40mm dia ball valve (brass insert), heavy duty, screwed down high pressure with handle, screwed both ends for GI pipe including all fittings / fixtures like nipple, union etc. with complete all as specified and as directed.
Material and labour for construction of stone masonary valve pit of size 600 x 600 x750 mm (internal dimension) built in cement mortar 1:4 including plastering 20mm thick internally and externally in CM 1:4, PCC 1:4:8 type D-2, 15 cm thick in foundation extending 10cm beyond external faces of wall around PCC flooring 1:2:4 type B-1, 40mm thick cover made out of 3.15 mm thick MS round bar and locking arrangement, MS sheet cover should be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing testing and commissioning of 35 cum/hr @ 35 mtr head Centrifugal pump with Bronze impeller pump for operation on 415 Volt 3 Phase squirrel cage, TEFC, copper wounded electric driven motor with class F, PVC insulated and sheathed copper cable of suitable current rating up to 10 mtr, for treated water tank from earthen pond to 1 Lakh litre treated water tank with 2 years maintenance warranty complete all as specified and as directed.
Supply, installation, testing and commissioning of cubical type floor mounted LT panel board, indoor type factory fabricated with CPRI approved manufacturer, made out of CRCA sheet of 2 mm thick, fully enclosed and angle iron frame of size 40 x 40 x 6 mm thick and T section with front openable double door shutter, dust and vermin proof and rear opening complete with locking arrangement, having a system of bus bars of aluminium TPN 400 Amps conforming to IS :5082 duly insulated and mounted on epoxy/ Porcelain insulators in totally enclosed chamber with 3 phase, 4 wire, 50 cycle, 415V, AC system pre-wired with suitable coper wire PVC insulated with all control accessories, duly painted internally, externally with two coats of synthetic enamel paint of approved quality over a coat of red oxide primer on PCC 1:2:4 type B-1 platform 60 cm above the ground level including connecting the existing cables/ earthings with the proposed LT panel with suitable size of thimbles nuts, bolts and washer etc complete all as specified and as directed, suitable for enclosing the following items :-
(a) Incoming: (i) MCCB FP 100 Amp 25 kA with Electronic/Microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral -01No (b) Outgoing: (ii) Automatic soft starter suitable for 35 cum/hr @ 35 mtr head centrifugal pumps -03 Nos (01Nos as spare) (iii) MCCB TP 32 Amp 25 KA with thermal /magnetic adjustment relay-03 No (iv) Aluminium bus bar 3 phase, 4 wire 600 Amp rating (v) Hylem sheet, bridge insulator cable gland. (vi) Indicating lamp R,Y,B (vii) Digital type volt meter / Amp. meter (viii) Digital frequency meter having range 0-50Hz-01 No (ix) Digital PF meter-01 No
Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using manual/ mechanical technique and necessary machinery including provision of HDPE pipe of 150 mm dia suitable for passing electric cables/ pipes complete all as specified and directed.
DG SET
Supplying, installation, testing and commissioning of diesel engine driven Generating Set of 82.5 KVA (66 KW) capacity, brushless type alternator self exited, self regulated and fitted with AVR and screen protected Drip proof with IP 23 protection , AMF panel of under at N. T. P condition fully wired 415 V AC 3 phase, 4 wire 4 stroke 50 Hz, at a power factor of 0.8 lagging all as per IS-4722/2001 mounted on common base plate and directly coupled through flexible coupling closed couple to diesel engine with Dunlop cushion foot mountings (anti vibration) pad in and including acoustic insulated enclosure/canopy with ARAI approved and as per CPCB norms and size of PCC/RCC foundation as per manufacturer's recommendation and complete all as specified and as directed by Engineer-in-charge at site etc. and consisting of the following:- (A) ALTERNATOR : Alternator confirming to BS:5000/ IS:4722 with standard design with IP 23 Protection, suitably rated at 82.5 KVA(66 KW) KVA at 0.8pf, 415 Volts, 3 phase, 4 Wires, 50 Hz., 1500 RPM, self excited (brushless excitation)and self regulated, Band of Voltage Regulation +/-1.5% of rated voltage (from no load to full load) and Class “H” Insulation. Alternator should be mounted on a common single base frame and coupled directly to the engine.
(B) Diesel Engine:- The engine shall be vertical multi cylinder four stroke 1500 RPM water cooled developing 88.47 BHP/ as per manufacturer design (to run of 10 % over load for 30 Min) confirming to BS:5514 suitable for continuous running fitted with electric governor, safety protection of LLOP & HWT complete with water pump assembly turbo charger, battery charging alternator of 12 V instrument panel, electronic in built, battery heavy duty with leads of suitable size and exhaust pipe of suitable length inclusive of exhaust coupling inside acoustic enclosure and residential silencer pipe above canopy all as specified and directed by OEM and all other standard fittings/fixtures and all as per OEM specification complete as per IS-1602 for the generator including the following:- The engine shall be complete with the following accessories: a) Heat Exchanger b) Corrosion inhibitor coolant c) Paper element filters for fuel, lube oil and by-pass d) Flywheel to single bearing alternator with housing. e) Dry type air cleaners and vacuum indicators f) PT Self Adjusting direct fuel injection system g) Silencer h) Stainless steel exhaust flexible bellows i) Electronic Control panel with digital governor suitable for synchronization. j) Electric Starter k) Battery charging alternator l) Electronic Instrument panel (Displaying the following): a. Battery Voltage b. Coolant Water Temperature c. Lubricating Oil Pressure d. Engine Speed e. Engine Hours
(m) Safety Control : High water temperature(HWT) (Trip & Indication for) : Low lube oil pressure (LLOP) : Over speed stop (n) Air inlet system, Charging system, Control system, Exhaust system. (o) Engine protection devices including audio visual indicators & OFF system during low lube oil pressure high water temperature over speeding of engine (p) Radiator cooling system comprising of radiator fan blade water pump with belts thermostat guard (q) Control MCCB :-MCCB4 pole 160 Amp 415V inbuilt with DG set- 1Nos
(D) Acoustic insulated enclosure/canopy for gen set:- The gen set to be provided with acoustic insulated enclosure/canopy fabricated out of CRCA sheet 16 SWG and pre treated with 7 tank phosphating prior to polyester coating painting close fit type compact enclosure provided with adequate ventilation system to ensure perfect aspiration and cooling of the DG set to bel housed inside and avoid over heating /power deration. Acoustic insulation sound proofing should be made with a high quality insulation conforms to UL94-HF1 class for flammability and suitable including the following:- (a) Control panel should have blanking windows made out of toughen glass provided with rubber beading (b) Emergency stop button should be easily accessible (c) Provn of fitting of branded make including wiring inside canopy (d) Access to fill fuel tank control shall be from outside the canopy enclosure (e) All door, windows panels should be lockable with single key (f) Single/multi point lifting facility should be available on the base frame (g) Access to fill the radiator from outside the canopy (h) Specially designed as per manufacturers standard alternators are to be provided control sound at entry to canopy and exist from canopy (j) Adequate ventilation has to be provided to meet the air requirement of engine and alternator (k) Emission control device to control hazaradous gaseous pollutant up to(PM 2.5,SOX ,Nox,HC CO ,CO2 Etc.) fitted in fuel gas exhaust suitable for engine capacity.
Note:- (i) Temperature rise in the compartment/canopy should be less than 5 degree centigrade (ii) It should adhere to mandatory noise regulation norms (iii) It should be duly approved and guaranteed by the engine manufacture (iv) The acoustic insulated enclosure/canopy must be designed as per relevant IS and control the noise level all as specified in Govt of India notification (v) LT cable from DG set to AMF panel shall be measured & paid separate (vi) The FOL etc required for commissioning and testing of DG set shall be supplied by the contractor. This shall be deemed to be including in the quoted rate of gen set (vi) Inverter canopy light of 10 W capacity luminous/narcotic make with necessary connecting from DG set battery. (vii) The cost of DG set platform is deemed to be included with unit rate of item. The design and drawing of plateform as per manufacturer recommendation.
MANNING AND OPERATION OF STP
Manning and operation of sewage treatment plant (new STP) and associated electro-mechancial equipments installed for Md Accn area at Darjipura, during defect liability period (two years), in two shifts of 8 hours each per day (i.e 1st shift from 0600 h to 1400 hrs and 2nd shift from 1400 hrs to 2200 hrs) including sundays and holidays by deploying one FGM in two shifts for STP consisting of components as in raw sewage pump, secondry clarifier mechanism with motor, air blower motor, filter feed pump, treated water pump, DG set, main panel board etc. complete all as specified and as directed.
Manning and operation of sewage treatment plant during monsoons/ as required basis of (period of 3 months/ year) for two year in one shift of 8 hours per day (i.e. from 2200 hrs to 0600 hrs) including sundays and holidays by deploying one FGM in one shift for STP consisting of components as in raw sewage pump, secondary clarifier mechanism with motor air blower motor, filter feed pump, treated water pump, DG set, main panel board etc complete all as specified and as directed.
Note for item 50, 51: (i) Necessary inventory shall be taken both the parties at the commencement of work and completion of work with regard to fittings and fixtures in the STP. (ii) Staff (all trade) shall always remain on duty and shall maintain the connected documents such as log book, attendence register, installation running record book, water sample maintainence book etc. and records shall be checked daily by Engineer-in-Charge. (iii) Contractor shall provide the necessary T & P (spanner set etc.) to tradesman and also provide the log sheet, plant running book, clothing etc. and all records are to be maintained properly. Contractor shall maintain attendence register and shall produce the same on submision of RAR/ bill and as and when required duly signed by contractor, concerned . (iv) STP Installation and the whole complex should be kept clean and tidy in presentable look by clearing grass and other unwanted materials in and around the area, otherwise a recovery at the double rate of quoted rate will be charged if the installation and the complex are not kept clean all the times. (v) Maintaining of records shall be considered essential and any negligence of duty during resource managements and any deficiency found during contract period shall be viewed by the concerned and necessary compensation shall be levied as per the contract procedure. (vi) Contractor shall ensure that no worker shall work continuously more than 48 hrs in a week. (vii) The electrician cum FGM shall perform any duties entrusted other than specifically mentioned in contract as detailed by JE/ Engineer-in-Charge. (viii) FGM cum Electrician shall be ITI pass or minimum matriculate with three years experience in the trade from recognized government institution. (ix) The tradesmen shall use chemicals carefully for maintaining the water quality, checking TDS and records shall be maintained properly. (x) Contractor shall provide life insurance of min 1 Lakh to all the employed manpower and copy of life insurance shall be deposited with department within one month of acceptance. (xi) No employee shall be absent on duty; if anyone found absent during the contract period, a recovery at the double rate of quoted rate shall be levied .
Vijay Construction Co
Kakolil Trade Agencies
M/s R. K. Bhambri
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .