Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC 54 10 C JAI DEVI NAGAR MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹18.5 L+₹46,580 (2.59%)Rejected-AOC DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹18.4 L+₹36,748.17 (2.04%)Rejected-AOC C 23 CC | L3 | Rejected-AOC NOT LOWEST |
Tender Value
₹18.9 L
EMD Value
₹37,800
Closing Date
27 Dec 2021, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ Commander Works Engineers Hills Mall Road Dehradun Cantt Dehradun 248003
SPECIAL REPAIRS TO BLDG NO T 53 COOK HOUSE OF 332 MED REGT AT RAIWALA MIL STN UNDER AGE I RAIWALA
2021_MES_490808_1
86331/RWL/E8
Open Tender
Civil Works
Item Rate
150 days
AGE I RAIWALA
Class E Cat a i
6 documents required · 6 mandatory
₹500
AGE I Raiwala
₹37,800
Yes
31 Jan 2022
27 Nov 2021
29 Dec 2021
27 Nov 2021
27 Dec 2021
14 Dec 2021
27 Nov 2021 - 4 Dec 2021
Amount
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings & removing from site complete all as specified & directed.
S&F Pre-painted galvalume aluminium zinc coating AZ-150 GI based Corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall , fixed with self tapping screws complete all as per instrctions of manufacturer's of galvalume sheet complete all as specified and directed .
S&F Pre-painted galvalume aluminium zinc coating AZ-150 GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall and gutter fixed with self tapping screws complete all as per instrctions of manufacturer's of galvalume sheet complete all as specified and directed.
Taking down roof trusses (wooden), coupled rafters or trussed beams trusses above 4 mtr & upto 8 mtr etc,for renewal of any defective members (timber renewed to be measured separately) and reassembling including Housing and fixing trusses etc. after repairs including tightening up wedges, cotters bolts etc complete all as specified and directed.
M&L 2nd class hard wood in scantling wrought timber framed and fixed complete all as specified and directed.
M&L preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with one coats of creosote oil complete all as specified and directed.
Dismantling mild steel work of any description not otherwise provided for & removing from site complete all as specified and directed.
M&L Mild steel Fe 410 -W (Gde-E- 250) quality- A, Roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S & F Rolled Mild Steel sections confirming to Fe 410 - W as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as specified & directed.
S & F Mild steel work in hand rails, wind ties, as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410 - O or Fe 310 - O complete all as specified & directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets and removing from site complete all as specified & directed.
S&F false ceiling (decorative type) 4 mm thick with GI framed work with main tee of size 24X28.5 mm made out of PGI sheet 0.3 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and wall angle 24X24X0.45 mm powder coated for celing, ceiling board 60cmX60cmX4.0 mm thick, suspended with GI wire 2 mm dia & upto 2 M average length with adjustable device complete. Ceiling board shall be pressed to the ceiling tee with staple clips at all four sides including making good all the disturbed portion, complete all as specified and directed. Note:- False ceiling material including GI frame powder coated alongwith all assessories shall be of same make.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each and removing from site complete all as specified and directed.
Taking down chowkhats or frames of any description with shutters (without taking off shutter from the frames) exe 1.5 Sqm but not exceeding 4.0 Sq.m each and removing from site complete all as specified and directed.
Providing and fixing Door frames (Single rebate) fabricated from roll formed sections made of Galvanised steel colour coated/powder coated (Base steel as per IS 513 “D” quality, Galvanised as per IS 277 with Zinc of 120 grams/sq Mtr With Coated sections should be Powder Coated with pure Polyester Powder up to 50-60 microns thick. Section outer frame should be 125 x 60 x 1.2mm with a rebate of 40mm to accommodate a GI door shutter of 35mm . The outer frame should be cut to length and joined by way of corner brackets/welding. Each frame should be provided MS Powder coated ISI Marked hinges of 100mm x 2mm- 4 Nos for single rebate. Each door frame will be provided with Al-drop hole and Tower bolt bracket . The Frame should be fixed to brick/concreted masonry by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frames PDF created. Back side of the door frame should be filled with Poloyol & Isocynate of 25frd and 30mrd. Item to be procured from any of the below mentioned companies- i)_Ashwani and sons, 1246/2 Meerut Road,Morta, Murad nagar-201003 ii)TATA Steel-Mumbai iii)Jindal,2-32,Gurgaon, Haryana-122001 iv) Ashish Industries, R-4/66, Raj Nagar, Ghaziabad
Providing and fixing Door (Double rebate) frames fabricated from roll formed sections made of Galvanised steel colour coated/powder coated (Base steel as per IS 513 “D” quality, Galvanised as per IS 277 with Zinc of 120 grams/sq Mtr With Coated sections should be Powder Coated with pure Polyester Powder up to 50-60 microns thick. Section outer frame should be 125 x 60 x 1.2mm with a rebate of 40mm to accommodate a GI door shutter of 35mm . The outer frame should be cut to length and joined by way of corner brackets/welding. Each frame should be provided MS Powder coated ISI Marked hinges of 100mm x 2mm- 8 Nos for double rebate. Each door frame will be provided with Al-drop hole and Tower bolt bracket . The Frame should be fixed to brick/concreted masonry by using Nylon self expanding caps and driving MS electroplated 80mm long screws into the caps through frames PDF created. Back side of the door frame should be filled with Poloyol & Isocynate of 25frd and 30mrd. Item to be procured from any of the below mentioned companies- i)_Ashwani and sons, 1246/2 Meerut Road,Morta, Murad nagar-201003 ii) TATA Steel-Mumbai iii) Jindal,2-32,Gurgaon, Haryana-122001 iv) Ashish Industries, R-4/66, Raj Nagar, Ghaziabad ph-9891542779
Providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated (PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows. . Windows to be procured from any of the below mentioned companies- i)_Ashwani and sons, 1246/2 Meerut Road,Morta, Murad nagar-201003 ii)TATA Steel-Mumbai iii)Jindal,2-32,Gurgaon, Haryana-122001 iv) Ashish Industries, R-4/66, Raj Nagar, Ghaziabad , Ph-9891542779
S&F 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, with decorative face veneers on one faces with leaping to match and commercial type on other side complete all as specified and directed.
S & F 35 mm thick second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars) chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in SSR Pt I Section 8, clause 8.24 (a) complete all as specified and directed.
S&F Aluminium anodized barrel tower bolt of size 12mm dia and 300 mm length of extruded section (ISI Marked) complete all as specified and directed.
S&F Extruded Aluminium alloy handles,fabricated type, anodised 150mm long, (ISI Marked) complete all as specified and directed.
S & F for Aluminum alloy, anodised sliding door bolt, of size 300mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy (ISI Marked) complete all as specified and directed.
S&F Floor door stopper (ISI Marked) of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor over all length of cover plate 150 mm complete all as specified and directed.
S&F 300 mm , MS ordinary rat tail rod pattern springs (ISI Marked) including roller and plate , door spring fixed to door shutter complete all as specified and directed.
S&F stainless steel non magnetic curtain rod 25 mm dia& 1.20mm thick with fixing brackets and decorative type brass knobs both side of each rod complete all as specified and directed. Note:- Measurement will be taken between end point of knobs.
M & L for Aluminium door seal upto 1200 mm long on bottom of door complete all as specified and directed.
S&F in repair Stainless steel (AISI 316 Grade) peg set of 5/6 pegs, 250-300 mm length of plate, complete all as specified and directed.
S&F in repair Stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples, complete all as specified and directed.
S&F Stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples fixed to door/window shutter complete all as specified and directed.
M&L Plain fillets of second class hard wood (suitable for joiner’s and carpenter’s work, locally available) section area exceeding 3 Sq.cm and not exceeding 6 Sq.cm, square, rectangular or triangular in section, clean sawn secured with nails complete all as specified and directed.
Dismantling of unframed fillets, rails, posts, rafters, purlins etc., under 40 Sq. Cm in section complete all as specified and directed.
M&L Plain fillets of second class hard wood (suitable for joiner’s and carpenter’s work, locally available) section area exceeding 13 Sq.cm and not exceeding 25 Sq.cm, square, rectangular or triangular in section, wrought secured with nails complete all as specified and directed.
M&L Preparation of New wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying 2 coats of synthetic enamel paint Ist Quality over a coat of pink primer complete all as specified and directed.
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated wood and wood based sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality complete all as specified and directed.
M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint First quality over a coat of red oxide zinc chrome primer complete all as specified and directed.
Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any wiidth or girth and preparation of previously untreated steel sufaces of any description not othrwise described over 10 cms width or girth and applying two coat of symthetic enamel paint (any tint) Ist quality complete all as specified and directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L Reinforced Cement Concrete Type C1 1:2:4 (using 20 mm graded stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L RCC 1:2:4 type B1 (using 20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and directed.
M&L RCC 1:2:4 type B1 (using 20 mm graded aggregate) in Chajjas / fins/ facia for minor repair drilling, welding, binding as required incl form work incl one coat of SBR latex as bonding of old concrete to new concrete complete all as specified and directed. Note:- 1. The work is required to be carried out at for single storeyed. The contractor shall make arrangement of scaffolding, safety and security of workers and arrangement for approach to roof . The rates quoted shall deemed to be included for these items.)
Use & waste Fair finished flat Form work to soffits of suspended slabs such as roof slabs, floor slabs and similar work not exc 200 mm thick complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia & over cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, approns, kitchen plateform / shelves etc and removing out of MOD land complete all as specified and directed.
M & L of 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M & L for machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment over sand cushioning 25mm thick (compacted thickness) watering & consolidated complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in kerbs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in Ground floors and paving n.exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specified and directed.
M&L cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) 75 mm thick as in plinth protection surface finished even and smooth without using extra cement including 4 mm thick glass dividing strip of figured glass, pin headed type, 73 mm wide inserted in position complete all as specified and directed.
M & L for 75 mm thick Cement concrete type D-2, 1:4:8 (using 20 mm graded granite stone aggregate) in sub base of flooring/ hard standing /footpath complete all as specified and directed.
M&L for Coloured ceramic tiles of any design and pattern, (all as approved by GE/AGE (I) ) area of each tile exceeding 0.18 Sqm but n.exc 0.36 Sqm ,7 to 8mm thick, in floor etc incl 15mm thick screed bed in CM 1:6, Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE (I)
M & L 18-20 mm thick machine cut kota stone slab flooring over cement screed base laid and incl 20 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing and polishing (mirror polished) complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises from MoD all as specified and directed.
M&L for coloured glazed ceramic tiles of any design and pattern, (all as approved by GE/AGE (I) ) 300x450x 7 to 8 mm thick, as in dado etc incl 10 mm thick rendering in CM 1:4, Set and jointed in neat cement slurry and pointed in white of coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and as directed. Note:- Shade of the tiles including Colour, design and pattern shall be got approved by AGE (I).
M & L for 16-18 mm thick machine cut pre polished kota stone slab as in riser of steps, skirting in full length in single peace without joint, of stair width laid over and incl 10 mm thick rendering of CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade including necessary grinding, rubbing and polishing complete all as specified and directed.
Demolition of brick work built in cement mortar in any description and position complete all as specified and directed.
M&L Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 with old size bricks complete all as specified and directed.
M&L Brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar CM1:4 with old size bricks complete all as specified and directed.
Taking down cement plaster, terrazzo dado in any thickness from brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including removal of rubbish, vegetation etc outside complex (MOD land) complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete walls external surfaces in two layerss first layer of 10 mm in CM 1:6 & 2nd layer of 5mm in CM 1:4 mixed with integral water proofing compound finished to even & smooth without using extra cement complete all as specified and directed. Note:- Integral water proofing liquid will be measured and paid seperately under relevent item of Sch A.
Supply only Integral water proofing liquid ( ISI Marked) as approved complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- 1. The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L for preparation of old decorated surface of exterior wall by complete removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers, then washing the surface with Bleaching powder solution for treatment of fungal growth and applying two coats of exterior anti fungal acrylic emulsion paint (wallmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of point and as directed at site by Engineer-in-Charge. Note:- (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are demand to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I) (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor
M&L Rendering 15 mm thick on fair faces of brick work or concrete walls internal surfaces in CM 1:6 finished to even & fair complete all as specified and directed.
M&L for preparation of newly plastered surface of internal wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer and wall care putty, using roller all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge. Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of old decorated surface of internal wall by removing existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and applying two coats of acrylic distemper using roller after prepration of surface all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge . Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials (like wall care putty), labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii). The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii). All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv). After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v). The colour / shade will be all as approved by GE / AGE (I)
Dismantaling water tanks and removing to store exc 500 but n. exc 1000 ltrs complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tank 1000 liters capacity, white two layer (ISI Marked) construction (cylindrical vertical with closed top), hoisted & fixed in position including all fittings complete all as specified and as directed.
S&F 20 mm dia ball valve (ISI Marked) high pressure PTMT with epoxy coated aluminium rod & high pressure plastic ball screwed for iron pipe and fixed complete all as specified and as directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 15 mm dia complete all as specified & directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia complete all as specified & directed.
M&L for Mild steel galvanized steel tubing of 15 mm bore (ISI Marked) with screwed socket joints as in concealed pipe work , medium grade, together with all fittings heavy grade (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed
M&L for Mild steel galvanized steel tubing of 20 mm bore (ISI Marked) with screwed socket joints, medium grade, together with all fittings heavy grade (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors Complete all as specified and directed.
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) together with all fittings heavy duty (ISI Marked ) (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.) and fixed complete to walls and ceiling with clips, wall hooks, wooden plugs or laid in floors complete all as specified and directed.
S & F in repair 20 mm dia Gun Metal, globe or Gate Valve (ISI Marked) Class 150 with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified & directed.
S & F in repairs 15 mm bore Stop valves (angular stop cock), cast copper alloy, fancy type, chromium plated, ISI Marked with long shank and cup screwed down high pressure with crutch or butterfly handle or concealed screwed both ends for iron pipe or for unions complete all as specified & directed. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S & F in repairs 15 mm bore chromium plated ISI Marked bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S & F in repairs 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, (ISI Marked) screwed for iron pipe complete all as specified & directed.Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S&F brass chromium plated towel Rail 20 mm dia, D-type, 600 mm long fixed with and including Chromimum plated brass screws and wooden plastic cleats complete all as specified & directed. Note:- Chromium plated fitting shall be brought in store yard first as approved by GE/AGE(I) and will be issued subsequently for fixing at site.
S&F for PVC Connections 15mm size with PTMT nuts of length 450 mm (ISI Marked) complete all as specified & directed.
S&F in repair Wash basin of size 550x400mm vitreous china (flat back type) any size including padestal (ISI Marked) incl cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fittings complete all as specified & directed.
S & F for Grating , stainless steel with / without hole, round 150 mm dia chromoum plated Complete all as specified and directed
S&F 32 mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6Kgf per Cm Square fixed to walls, ceilings or in floors etc complete all as specified & directed.
S & F in repairs Sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 and bowl size 410mm x 330 mm x 160mm complete all as specified & directed.
S&F in repairs to Stainless steel kitchen plate rack 24 gauge thick sheet of over all size 31"x26"x10" fixed with steel screws and steel rawal plugs complete all as specified & directed.
M&L for post construction Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified & directed.
M&L for post construction Anti termite treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified & directed.
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note:- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc complete all as specified & as directed. Note:- If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down old damaged existing DB’s of any type and making good the disturbed surfaces of wall/floor to match with the existing wall/ceiling etc complete all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit, medium grade(ISI marked) ,duly concealed on wall/ceiling or above false ceiling with fittings not less than 20 mm dia medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface shall be deemed to be included in quoted rates. ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
M&L One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
All as per item no 92 here-in-before but for One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed.
All as per item No 92 here-in-before but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
S & F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or equivalent make of L&T/Havells
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC complete all as specified and directed. Make: Legrand cat No: 673411/ Indoasian Cat No: 800002 or equivalent make of L&T/Havells
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.Make: Legrand cat No: 6734 52 / Indoasian cat no: 800020 or equivalent make of L&T/Havells
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz complete all as specified and directed. Make: Legrand cat No: 6734 55 / Indoasian cat no: 800022 or equivalent make of L&T/Havells
Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals ISI Marked complete all as specified & directed.
Supply and fix surface mounted LED luminiare, 20 watt 4 feet with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. Make:- Havells cat No: LHEXACP7UN1W020 or Shakti cat No: SZSLBMX020 or Crompton cat No; LCTLN-20-NW. Note: The firm has to give warranty for fitting including driver minimum for 3 years for any defects developed during the period.
Supply and fix new LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.98 having overvoltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit prtection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive wway, 80 degree luminaire efficiciency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500 K including fixing on existing bracket including connecting with 1.5 sqmm , 3 core, PVC insulated copper onductor cable 1100 Volt grade from distribution box to light complete all as specified and as directed. Make:- Havells cat No: LHEXAYP7PN6K020 or Shakti cat No: SZPCLPM020 or Crompton cat No; TRP-400-20-57-SL-LM-NSR . Note:- (i) The firm has to given warranty of street light fittings including driver minimum for 03 years for any defect developed during the period. (ii) The contractor Shall submitt the third Party LM 79 report from any NABL approved laboratory (iii) The fiitting should have BIS , CRS No (iv) Connection to luminaire shall be done in suitable PVC connector within the bracket/luminaire end and are inclusive in above.
Supply and fix LED 36 watt recess mounted 2' x 2' light fitting diffuese acrylic cover with all accessories having high lument output, driver PF>0.98, having over voltage protection upto 400 volt, ISI marked, surge protection level 7-10 KV, thermal short circuit protection THD<10% made up of long life LED chips (SMD) in modular with Ra>70 and square back lit panel 2 x 2 LED luminaire with diffuser 3 core flexible copper cable PVC insulated of size 1.5 Sqmm complete all as specified & directed. Note: The firm has to give warranty for LED panel fitting including driver minimum for 2 years for any defects developed during he period. Make: Shakti cat No: SZRELMX036 or Crompton cat No; LCTLRNE-36-FO-TL or Bajaj cat No: BZR SQL 36 W WH.
Supply and fix Exhaust fan heavy duty size 450 mm sweep single phase and 900 RPM with bracket , louvers, opening/core cutting the wall of any type bricks or stone and grouting with MS rag bolts etc making surface good and connecting from ceiling rose/connector to fan with and including provn of PVC insulated and sheathed three core copper conductor flexible cable FRLSH of size not less than 1.5 Sqmm sufficient length complete all as specified and directed. Note:- Contractor shall submit the guarantee from manufacturer for Exhaust fan for minimum 3 years for any defects developed during the period. Make: Havellls/Crompton/Philips
Supply and fix water heater storage type, 5 Star Rated electric operated, capacity 50 Ltrs, BEE 5 star rated, 2 KW heating element including hot and cold water pipe, NRV, and accessories including necessary GI pipe of 15 mm dia size from service tank to Geyser grouting on wall with stainless steel anchor fastner complete all as specified and directed. Make :Havells/Crompton/Crompton
S & F single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB SPN 10 Amps complete all as specified and directed.
Supply and fixing sheet metal enclosure double door type for MCCB DB VTPN 4 way with suitable for fixing MCCB 4 pole, complete all as specified and directed.
S & F MCCB 32 Amps, 4 pole, breaking capacity 10kA @415V AC, 50Hz conforms to IS/IEC 60947-2, Ics=100% of Icu, High electrical & mechanical life, thermal magnetic Release, No load-line Bias, ON-Trip-OFF indication complete all as specified and directed.
M & L Sheet metal MCB DB SPN 6 way 240 Volts, double door type powder coated with 200 amps rated bus bar, neutral link, earth rail & din rail, ISI marked for fixing of MCBs complete all as specified and directed. . Note:- (i) MCBs measured and paid separately under respective items. (ii) MCBs shall be of uniform make.
M & L Sheet metal MCB DB SPN 4 way 240 Volts, double door type powder coated with 200 amps rated bus bar, neutral link, earth rail & din rail, ISI marked for fixing of MCBs complete all as specified and directed. Note:- (i) MCBs measured and paid separately under respective items. (ii) MCBs shall be of uniform make.
Supply and fixing MCB SPN 16-25 Amps rating 240 volts, 10 Ka, 'c' curve miniature circuit breaker(MCB), ISI marked, 50 Hz with cable connection and copper lugs complete with connection testing complete all as specified and directed.
Supply and fixing 240 v, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 20 Amps, ISI marked, 50 hz with cable connecting and copper lugs complete with connection testing complete all as specified and directed.
Supply and fixing sub main wiring two single core 4 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 4.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Suppl;y only 4mm dia GI wire complete all as specifed & directed.
Supply and lay in repair GI pipe galvanized, "Medium grade class' including fittings 40 mm size with plain socket on under ground and connecting near by exisiting pipe line complete all as specified and directed.
Excavation in trenches in any type of soil and n.exc 1.5 m wide and n. Exc 1.5 in depth for laying GI tubing for connect to near by water pipe line or for poles, laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and directed.
Returing, filling in any type of soil including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, in any type of soil complete all as specified and directed.
Removing excavated material ( surplus soil) to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specifed and directed.
Cutting of existing GI pjpe of size 40 to 50 mm bore in position for insertion of new branch line of any bore complete all as specifed and directed by Engr-in-charge.
S & F in repair 40 mm dia Gun Metal, globe or Gate Valve (ISI Marked) Class 150 with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified & directed.
Supply and laying cable XLPE, PVC sheathed, steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area of size 25 Sqmm 3.5 core with required aluminum cable lugs, lugs should properly crimmed with crimmping tools, connect on existing LT pole and New DB complete all as specified and directed by Engr-in-charge. While passing through MCB DB use proper size of cable glands complete all as specified and directed. Make: Havells/Finolex/Polycab
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid.
M & L for cutting of road/hard standing as required at site, minimum 20 cm width and minimum 60 cm in depth for laying of cable protection pipe including making good the disturbed road /hard standing by providing PCC (1:2:4) type B-1 up to the existing surface level and make good complete all as specified & directed. Note:- If contractor fail to make the road good after cutting the penalty of Rs 500 Mtr will be imposed bythe Department.
Supply and laying GI tube light grade 50 mm dia with all fittings laid in trenches or fixed on pole for protection of cable complete all as specified and directed.
M & L Brick class 'B' for protection of under ground cable complete all as specified and directed.
RAMAN CONSTRUCTION CO.
TARUN ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .