AGE (I) R AND D JODHHPUR
AGE (I) R AND D DEFENCE LAB JODHHPUR
REPAIR AND MAINTAINANCE OF CASSETTE ACs AND TOWER ACs INSTALLED IN ZONE-B AT DEF LAB JODHPUR
2023_MES_580927_2
8522/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) R AND D JODHHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹16,000
Yes
1 May 2023
28 Mar 2023
27 Apr 2023
28 Mar 2023
25 Apr 2023
6 Apr 2023
29 Mar 2023 - 5 Apr 2023
Amount
M&L servicing of casette type inverter AC of 1.65/2.7 TR cap indoor & 4.0 TR outdoor by taking out the same from existing location, cleaning of condenser, cooling coil and other components with approved chemical solution & clean water, greasing of fan, motor, blower etc without damage any paart and reinstall at the same location complete all as specified and directed by Engineer-in-Charge
S&F in replacement PCB for out door any type/model of 4.0 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
M&L, repairs to existing PCB any type/model for out door of 4.0 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
S&F in replacement PCB any type/model for indoor casette AC 1.65/2.7 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
M&L, repairs to existing PCB any type/ model of casette AC 1.65/2.7 TR capacity by changing parts /soldering etc complete all as specified and directed by Engineer-in-charge.
S&F in replacement Adaptor (Capacity Controler) complete all specified and directed by Engineer-in-charge.
S&F in replacement Thermistor (LIQ) complete all as specified and directed by Engineer-in-charge.
S&F in replacement Thermistor (AIR) complete all as specified and directed by Engineer-in-charge.
M&L recharge top up gas refrigerant R-410A in casette type of cap 1.65/2.7 TR complete all as specified and directed by Engineer-in-charge.
S&F in replacement fan blower of casette type 1.65/2.70 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
S&F in replacement fan motor of casette type 1.65/2.70 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
M&L finding out leakage with the pressure testing of the condensor/cooling unit/ compressor of casette type AC of 1.65/2.7 Ton cap including dismantling the same for recharging and stop leakage by brizing/soldering including charging the R-410A gas to required level and testing the AC for the entire satisfaction of Engineer-in-Charge.
S&F in replacement of the defective scroll compressor Sealed unit 4.0 TR Capacity casette type Air conditioner after cutting copper tubing without any damage to existing other parts, replacing compressor with new sealed unit (compressor) of same make complete with erection of compressor in same location with suitable base, jointing of copper refrigerant pipe line, charging of gas to required level, leakage testing etc including testing for smooth functioning. NOTE:- (i) The rate quoted by the contractor shall be inclusive of all chages like transporation, fittings, etc. complete with necessary guarntee period including oiling and R-410A gas charging, testing etc, comnplete Make as per sample, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of blower and bush of casette type 1.65/2.70/4.0 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
S&F in replacement of fan blade of casette type 1.65/2.70/4.0 TR capacity of existing make complete all as specified and directed by Engineer-in-charge.
M&L, repairs to existing blower moter of AC 1.65/2.7 TR capacity by re-winding / changing parts /soldering etc complete all as specified and directed by Engineer-in-charge.
Supply and fix wire harness assy suitable for outdoor/ indoor unit as per sample and make for existing all as directed.
Supply and fix crankcase heater suitable for outdoor unit as per sample and make for existing all as directed.
Supply and fix coil motorized valve suitable for outdoor unit as per sample and make for existing all as directed.
Supply and fix capacitor of any type suitable for outdoor/ indoor unit as per sample and make for existing all as directed.
Supply and fix in replacement of old unsv remote control suitable for cassette type AC as per sample and make for existing all as directed.
M&L, for pipe insulation suitable for outdoor/ indoor complete all as specified and directed by Engineer-in-charge.
S&F contractor suitable for outdoor unit complete as per sample and make for existing all as directed by Engineer-in-charge.
S&F filter suitable for indoor unit cassete type complete as per sample and make for existing all as directed by Engineer-in-charge.
S&F filter drain pump for indoor unit cassete type complete as per sample and make for existing all as directed by Engineer-in-charge.
S&F MCB SP 6 - 32 Amps 230 V including taking down old UNSV MCB Complete all as specified and as directed by Engr-in-Charge Make L&T/Legrand/Schnider/Havells or any equivalent approved make
S&F MCCB 4 pole 415 volts 160 Amp breaking capacity 36 KA including taking down old UNSV MCCB Complete all as specified and as directed by Engr-in-Charge .Make L&T/Legrand/Schnider/Havells or any equivalent approved make
S&F MCCB 4 pole 415 volts 63 Amp rotary type breaking capacity 16 KA including taking down old UNSV MCCB Complete all as specified and as directed by Engr-in-Charge .Make L&T/Legrand/Schnider/Havells or any equivalent approved make
S&F three core copper cable 6 sqmm all as specified and as directed by Engr-in-Charge
vinayandsons
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .