Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance VP 10 323 CHITHRALAYAM NALANKALLU VILAVOORKAL MALAYINKEEZHU THIRUVANANTHAPURAM 695571 | THIRUVANANTHAPURAM | KERALA | 695571 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹30,034
Closing Date
8 Jan 2021, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Manager (Subcontract)
KEL, Kochi
SETTING UP OF NEGATIVE PRESSURE ICU AT GENERAL HOSPITAL ALAPPUZHA 1
2021_KEL_403562_1
KRO/BDC/794/2020
Open Tender
Miscellaneous Works
Item Rate
90 days
KEL, Kochi
As per NIT
6 documents required · 6 mandatory
₹2,950
₹30,034
Yes
11 Jan 2021
1 Jan 2021
11 Jan 2021
1 Jan 2021
8 Jan 2021
1 Jan 2021
1 Jan 2021 - 6 Jan 2021
120 days
Amount
VRF OUTDOOR UNITS Outdoor units equipped with highly efficient scroll compressors with all inverter type compressor(s) only,special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error,auto address setting. 8 HP Make : LG
DOUBLE SKIN AHU Supply and installtion of TFA Unit with 8 row Pre-Plasticised Sheet/ powder coated, Extruded Aluminium panta post frame work, Fan section, coil section, filter section, with necessary insulations, drain pan, etc. Cooling coil of copper tubes and aluminium fins (min. 10 fins per inch) and required number of rows deep. TEFC sq.cage induction motor of required rating including mounting and fixing arrangements of follwoing capacity 6 TR, 1900 CFM.
AHU CONNECTING KIT Supply of AHU Connecting kit and expansion kit suitable for AHU Make : LG
Starter Panel for AHU
REFRIGERANT PIPE Supply and Installation of Refrigerant piping insulated with13mm nitrile rubber insulation between the condensing unit and the indoor unit, with Soft drawn copper pipes with brazed joints for both one run supply and one run return lines and finished with necessary supports as per the specifications and drawings.
ELECTRICAL CONTROL CABLING Supply, installation, testing and commissioning of Control Cabling between condensing unit and evaporative units for all types of Air Conditioning Units as above.
DRAIN PIPING Drain piping insulated with 9mm thick nitrile rubber insulation of closed cell elastometric with density not less than 80kg/m3 of required diameter etc.complete
GI DUCTING AND INSULATION Supply, installation balancing and commisnioning of GSS sheet metal ducts rectangular ducting complete with neoprene rubber gaskets,elbows,splitter,dampers,vanes,hangers,supports etc as per approved drawings & specification of following sheet thickness. Thickness 24 Gauge
GI DUCTING AND INSULATION Supply, installation balancing and commisnioning of GSS sheet metal ducts rectangular ducting complete with neoprene rubber gaskets,elbows,splitter,dampers,vanes,hangers,supports etc as per approved drawings & specification of following sheet thickness.Thickness 22 Gauge.
Supplying and fixing of following thickness closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 13 mm.
Supply, installation, testing and commissioning of Acoustic duct lining using 10mm nitrile rubber insulation open cell type inside the ducts, antimicrobial protection at the outlets of all indoor units.
Powder coated extruded Supply air grills with vcd.
Supply of Return Air Grills.
Canvas Connection for AHU Units.
Supply and installation of 2200 CFM Exhaust fan. Make: Kruger, Greenheack.
Supply and Installation of UV Lamp and Hepafilter.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.
Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required. (Make: ABB or Legrand). 63A 10KA TP MCB (C curve)
Supply and installation of the following accessories suitable for 50 Hz, 240/415 V, AC supply conforming to IS 8828-1995 / IEC 60898-1 of the following current ratings in the existing enclosure / DBs and giving connections as required. (Make: ABB or Legrand). 40A 10KA TP MCB (C curve)
Supply, testing and commissioning of the following Armoured copper cable- 4c x 6 sq.mm.
Supply, testing and commissioning of the following Armoured copper cable- 4c x 2.5 sq.mm.
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof 4-pole enclosure including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / isolator etc fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc as required.(IP-68)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof 4-pole enclosure including copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / isolator etc fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Providing and fixing 4.00 mm (8 SWG ) dia copper wire on surface or in recess for loop earthing as required.
Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
Push Button- L&T, Schneider, Rishabh
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of installation, testing and commissioning cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD/Irrigation Dept. specification and direction of Engineer at site.
RAGLO PRIVATE LIMITED
CHITHRANI TRADERS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .