Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹36.2 L+₹1.8 L (5.25%)Rejected-Finance CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹36.4 L+₹2.0 L (5.85%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹38.5 L+₹4.2 L (12.1%)Rejected-Finance 3 333 F M P ARCS VENGACHUVADU VAZHAKKULAM P O CHAITHANYA BUILDING SA ROAD KADAVATHRA MUVATTUPUZHA ERNAKULAM 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹40.2 L+₹5.9 L (17.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
9 Oct 2019, 6:00 pmClosed
GE (NS) Kochi
Naval Base Kochi 682004
REPAIR AND MAINTENANCE OF LT UG CABLES, JUNCTION BOXES, LT FEEDER PILLAR BOXES AT GARUDA, NAY, SFNA, 33 WEU, BV YARD, VARIOUS OTM AND MD ACCN, NAVAL BASE KOCHI
2019_MES_279418_1
8666/E8 Repair Maint LT UG Cable Garuda
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
NBK
Class D
Category b i
8 documents required · 8 mandatory
₹500
Yes
GE (NS) Kochi
₹80,000
Yes
12 Feb 2020
3 Sept 2019
10 Oct 2019
3 Sept 2019
9 Oct 2019
17 Sept 2019
3 Sept 2019 - 16 Sept 2019
Amount
Taking down existing connection from LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles/ Building carefully (any capacity, any type) carrying out repair work at site including replacement of unserviceable/ defective screw/nut & bolts/ Washers/Lugs/Spreaders/Hinges of doors/Repair to Locks & handles/ Indication Lamps/meters/Cable glands/Bus Bar (Copper/Aluminium) etc, refixing the fittings in its original position, testing and commissioning, including removal of bushes, creapers and trimming of branches around the LT Panel/Bus Bar Chamber/Feeder Piller/ Electric Poles complete all as specified and directed . Note: (i) The quoted rate is deemed to be include any major repair if required, attending complaints and replacement of any components in LT Power network, etc. The items replaced shall be measured and paid separately as supply only. (ii) Tools, ladder, vehicle required to carry out the work shall be provided by the contractor. (iii) Contractor shall ensure the safety of the workers employed at his own risk. (iv) Contractor shall provided Skilled ITI Electrician and produce the ITI Certificate for verification before commencment of work. (v) Contractor shall ensure to render completion of all complaints attended to JE/Engr-in Charge on day to day basis .
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 300 Sqmm 3.5 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 240 Sqmm 3.5 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 185 Sqmm 3.5 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 150 Sqmm 3.5 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 120 Sqmm 3.5 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 95 Sqmm 3.5 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 70 Sqmm 3.5 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 50 Sqmm 3.5 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 35 Sqmm 3.5 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 25 Sqmm 3.5 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 16 Sqmm 4 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 10 Sqmm 4 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 16 Sqmm 2 core complete all as specified.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of of size 10 Sqmm 2 core complete all as specified.
Excavating trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth to find out defected armoured LT UG cable by getting out soil, cable cover, sand cushioing, repair the cable with suitable cable joints and re-lay the cable, returning filling with retrived cable cover, sand etc complete all as specified and direced. Note : Sand for cushioning, cable joint, addtionnal cable for joining shall be measured and paid seperately under relevent items.
Excavating trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unseviceable LT Cable for laying of cable and getting out complete all as specified.
M & L Sand cushioning to under ground cables 8 cm thick before laying and 15cm after laying cables complete all as specified.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete complete all as specified..
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
M & L Brick well burnt Class ‘B’ as in cover to UG cable, laid dry, flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over UG cable for cable protection in trenches complete all as specified.
Cutting existing road/hardstand upto a depth of 30cm for laying GI pipe including making good the surface by returning filling watering ramming in layers, 150 mm thick PCC 1:2:4 over 200 mm thick hard core of stones aggregates over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified.
S & F 50mm bore GI pipe, light grade, on LT pole, under road crossing for protection of LT cables (GI protection pipe should be fixed with suitable size of clamps, nuts bolts etc, which will be paid separately) complete all as specified and directed.
S & F 40mm bore GI pipe, light grade, on LT pole, under road crossing for protection of LT cables (GI protection pipe should be fixed with suitable size of clamps, nuts bolts etc, which will be paid separately) complete all as specified and directed.
Repair to existing feeder pillar box after disconnecting all incoming and out going cable connections and re-thimbling of various sizes of cables ,including cable loop for required sizes connecting up and making good including repairing to doors , fixing hinges and locking arrangements and including painting after removing rusts, dusts etc, with one coat of existing paint complete all as directed.
M & L Cutting and removing grass including its root / bushes vegitations at the permises of LT feeder pillar boxes by using necessary tools , removing the grass etc complete all as directed.
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade of size 3.5 core , 240sqmm to 300sqmm including taking down of old one,all as specified,and as directed.
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade of size 3.5 core , 150sqmm to 185sqmm including taking down of old one,all as specified,and as directed.
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade of size 3.5 core , 70sqmm to 120sqmm including taking down of old one,all as specified,and as directed.
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade of size 3.5 core , 25sqmm to 50sqmm including taking down of old one,all as specified,and as directed.
Supply and fix, cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade of size 3.5 core , 6sqmm to 16sqmm including taking down of old one,all as specified,and as directed.
Supply and fix, in replacement MCCB 4Pole, 630 Amps, 36kA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as directed.
Supply and fix, in replacement MCCB 4Pole, 400 Amps, 36kA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as directed.
Supply and fix, in replacement MCCB 4Pole, 320 Amps, 36kA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as directed.
Supply and fix, in replacement MCCB 4Pole, 250 Amps, 36 kA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as directed.
Supply and fix, in replacement MCCB 4Pole, 200 Amps, 25 kA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as directed.
Supply and fix, in replacement MCCB 4Pole, 160 Amps, 25 kA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as directed.
Supply and fix, in replacement MCCB 4Pole, 125 Amps, 16kKA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as directed.
Supply and fix, in replacement MCCB 4Pole, 100 Amps, 16 kA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as directed.
Supply and fix, in replacement MCCB 4Pole, 63 Amps, 16kA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as directed.
S & F in replacement Mannual Change over switch with enclosure 4 Pole, 250 Amps, 36 KA, 415 V , complete all as directed.
S & F in replacement Mannual Change over switch with enclosure 4 Pole, 250 Amps, 36 KA, 415 V , complete all as directed.
M/s.Rejoy Constructions
PHEJAYS AGENCIES
Linsta Services
General Engineering and Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .