| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹36.6 L+₹75,356 (2.10%)Rejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹39.3 L+₹3.4 L (9.60%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
17 Nov 2021, 6:00 pmClosed
GE (AF) CHILODA
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
COMPREHENSIVE REPAIR AND MAINTENANCE OF COOLING APPLIANCES OF HQ SWAC AT VSN GANDHINAGAR AND REPAIR/ MAINT OF RO PLANT, DOSING PUMP AND ALLIED WORKS AT HQ SWAC, SEC-09, SEC-17 GANDHINAGAR AND COMN FLT AHMEDABAD UNDER GE (AF) CHILODA
2021_MES_483273_1
8969/21-22/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Gandhinagar
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (AF) CHILODA
₹70,000
Yes
18 Dec 2021
22 Oct 2021
19 Nov 2021
22 Oct 2021
17 Nov 2021
5 Nov 2021
Amount
M&L for taking down of Acs of split type capacity 1.5/ 2.0 TR from the existing site and taking out filter and servicing the complete in all respact and fixing the same in origanal location, and testing complete all as specified and as directed. Note:- Contractor has to provide blower and jet pump for cleaning and washing of AC, A separate PVC bag will also be provided for collection of waste, mechanic will be responsible to clean the site after servicing.
S&F in repair foam armoar of size 5/8" in repair for AC copper tubing complete all as specified and as directed.
S&F in repair foam armoar of size 1/4" for AC copper tubing complete all as specified and as directed.
M&L for dismentaling and shifting the existing split Acs of cap 1.5/ 2.0 ton to new location complete all as specified and as directed. Note:- Copper pipe will be measured and paid separately under relevant items.
S&F in repair starting capacitor suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair starting capacitor suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair starting capacitor suitable for existing window AC of cap 1.0/ 1.5 TR complete all as specified and as directed.
S&F in repair running capacitor suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair running capacitor suitable for existing window AC of cap 1.0/ 1.5 TR complete all as specified and as directed.
S&F in repair starting relay suitable for existing split AC of cap 1.5/ 2.0 complete all as specified and as directed.
S&F in repair starting relay suitable for existing window AC of cap 1.0/ 1.5 TR complete all as specified and as directed.
S&F in repair front grill with filter for window type AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair circuit plate with PCB for 1.5/ 1.0 TR window type AC complete all as specified and as directed.
M&L in repair for sub main wiring complete with PVC insulated FR cable of single core 6 Sqmm 660/ 1100 Volts geade with multi stranded copper conductor drawn through existing steel/ PVC conduit concealed or surface/ ceiling and 6 Sqmm unsheathed multi stranded copper conductor as earth wire in green colour complete all as specified and as directed. Note:- Two runs of cable and one run of earth wire shall be measured as one unit length.
M&L in repairs for fabrication stand for (desert coller) by angle iron of size and fixing in to wall at window side for holding of desert cooler with paint on the stand as approved quality, including taking down of desert cooler from ist and 2nd floor of old location and fixing at new palce, complete all as specified and as directed by Engr-in-Charge.
M&L for rewinding of blower motor for 1.0/ 1.5 TR split/ window AC complete all as specified and as directed.
M&L for rewinding of blower motor for 2 TR split AC complete all as specified and as directed.
S&F in repair SPN enclouser with a two pin and earth plug and sockets complete with one single pole MCB 20/ 32 Amps cap complete all as specified and as directed.
S&F in repair compressor suitable for existing windowtype AC 1.0 TR complete all as specified and as directed.
S&F in repair compressor suitable for existing windowtype AC 1.5 TR complete all as specified and as directed.
S&F in repair compressor suitable for existing split type AC 1.5 TR complete all as specified and as directed.
S&F in repair compressor suitable for existing split type AC 2.0 TR complete all as specified and as directed.
S&F in repair condenser suitable for existing window type AC 1.0/ 1.5 TR complete all as specified and as directed.
S&F in repair condenser suitable for existing split type AC 1.5 TR complete all as specified and as directed.
S&F in repair condenser suitable for existing split type AC 2.0 TR complete all as specified and as directed.
S&F in repair blower suitable for window type AC 1.5 complete all as specified and as directed.
S&F in repair condenser fan blade suitable for split AC 1.5 TR complete all as specified and as directed.
S&F in repair condenser fan blade suitable for split AC 2 TR complete all as specified and as directed.
S&F in repair fan blade (evaporator) suitable for split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair fan blade (evaporator) suitable for split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair circuit plate with PCB suitable for split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair circuit plate with PCB suitable for split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair PVC air filter suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair PVC air filter suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair PVC air filter suitable for existing window AC of cap 1.0/ 1.5 TR complete all as specified and as directed.
S&F in repair remote controller suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair remote controller suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair swing motor suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair swing motor suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair condenser motor suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair condenser motor suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair condenser motor suitable for existing window AC of cap 1.0/ 1.5 TR complete all as specified and as directed.
S&F in repair contactor relay suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repair contactor relay suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repair contactor relay suitable for existing window AC of cap 1.0/ 1.5 TR complete all as specified and as directed.
S&F in repair copper tube of 16 Sqmm bore complete all as specified and as directed.
S&F in repair copper tube of 12.7 Sqmm bore complete all as specified and as directed.
S&F in repair copper tube of 9.5 Sqmm bore complete all as specified and as directed.
S&F in repair copper tube of 6.3 Sqmm bore complete all as specified and as directed.
S&F in repair drain pipe PVC, 3 mtr in length, suitable for split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair bracket suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair brass valve1/4" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair brass valve1/2" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair brass valve 5/8" suitable for existing split AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
Supply and filling gas freon (R22/R32) or suitable for existing system complete all as specified and as directed. Note:- (i) Gas bottle to be arranged by contractor. (ii) Labour charges deemed to be included in quoted rate.
S&F in repair acrylic vegetable tray suitable for existing refrigerator of cap 165 to 310 ltr complete all as specified and as directed.
S&F in repair relay with over load protector suitable for existing refrigerator of cap 165 to 310 ltr complete all as specified and as directed.
M&L for repair to body/ base of water cooler 40/ 80 ltr cap ,by replacing the rusted portion with PGI sheet to match with existing body with and incl preparation of surface to smooth finish and duly painted complete with two coats of synthetic enamel paint complete all as specified and as directed.
All as per Item No. 58 above but cap 120 ltr water cooler.
All as per Item No. 58 above but cap 165 to 320 ltr refrigerator.
All as per Item No. 58 above but desert cooler.
M&L for praperation of exterior portion of water cooler 40/ 80 ltr cap to a smooth finish and applying two coats of synthetic enamel paint complete all as specified and as directed.
All as per Item No. 62 above but 120 ltr cap.
Supply and filling refrigerant gas freon R-134A/ R-32/ R-410A or as recommended by manifactror Supply and filling Note:- (i) Gas bottle to be arranged by contractor. (ii) Labour charges deemed to be included in quoted rate.
M&L for taking out desert cooler of any size and capacity from existing site for repair and dismentaling of all components from evoparative cooler(desert cooler) metal body very care fully i.e. exhaust fan,motor, Tulu pump, PVC spare parts i.e. distributor, PVC pipe, tee, bend, elbow, holding clamp and any number of nut, bolt, washer, grass paid etc, including praparation of exterior & interior portion on cooler to a smooth finish and applying one coats of bituminious paint and reaasembling the same in existisng position in cooler for smooth running complete all as specified and as directed. Note:- If any warm out items/ parts noyiced during the assembling the same shall be measured and separately under the relavent items.
S&F in repair starting relay suitable for existing refrigerators/ water cooler complete all as specified and as directed.
S&F in repair starting relay suitable for existing deep freezer of cap 120 to 500 ltr cap complete all as specified and as directed.
S&F in repair over load protection suitable for existing refrigerator/ water cooler/ deep freezer of any cap complete all as specified and as directed.
S&F in repair fan motor suitable for existing water cooler 80 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for existing water cooler 120 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for existing water cooler 400 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for existing deep freezer 120 to 500 ltr cap complete all as specified and as directed.
S&F in repair brass chromium plate push cock of 15mm dia complete all as specified and as directed.
S&F in repair cabin bulb 5 Watt for refrigerator complete all as specified and as directed.
S&F in repair cabin bulb holder for refrigerator with cabin brackets complete all as specified and as directed.
S&F in repair thermostat switch for water cooler/ Ref/ deep freezer 40 to 500 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for refrigerator 100 ltr to 195 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for refrigerator 200 to 280 ltr cap complete all as specified and as directed.
S&F in repair fan motor suitable for refrigerator 292 to 335 ltr cap complete all as specified and as directed.
S&F in repair timer suitable for refrigerator of cap 100 ltr to 195 ltr cap complete all as specified and as directed.
S&F in repair timer/ bio meter/ heater suitable for refrigerator of cap 200 to 335 ltr cap complete all as specified and as directed.
S&F in repair condenser suitable for existing water cooler of cap 40/ 80 ltr complete all as specified and as directed.
S&F in repair condenser suitable for existing water cooler of cap 120 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing water cooler of cap 40/ 80 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing water cooler of cap 120 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing deep freezer of cap 170/ 500 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing refrigerator of cap 100 to 195 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing refrigerator of cap 200 to 280 ltr complete all as specified and as directed.
S&F in repair compressor suitable for existing refrigerator of cap 300/ 335 ltr complete all as specified and as directed.
S&F in repair fan blade for desert cooler complete all as specified and as directed.
S&F in repair PVC connection set of three suitable for existing desert cooler complete all as specified and as directed.
S&F in repair cable three core flexible twisted copper conductor of 1.5 Sqmm complete all as specified and as directed.
S&F in repair cable three core flexible twisted copper conductor of 2.5 Sqmm complete all as specified and as directed.
S&F in repair front grill suitable for existing desert cooler complete all as specified and as directed.
S&F in repair grass paid set of three superior quality complete all as specified and as directed.
S&F in repair fan motor 1.0 Ph, 50 Hz, 230 V, AC max amp 1.5 suitable for existing desert cooler complete all as specified and as directed.
S&F in repair water submersible pump 240 V, AC, 50 Hz, 10 Watt, 5 LPM, 2 mtr head complete all as specified and as directed.
S&F in repair ON-OFF switch 5 Amps 240 V for water pump complete all as specified and as directed.
S&F in repair GI shutter as existing at site complete all as specified and as directed.
S&F in repair mounting bracket for fan motor with nut and bolts etc of desert cooler complete all as specified and as directed.
S&F in repair capacitor 4 Mfd + 5% 440 V, MPP 'SH' complete all as specified and as directed.
S&F in repair industrial motor suitable for 24 sweep fan complete all as specified and as directed.
Comprehensive maintenance and servicing of VRV air conditioner of model RXYQ18TRY6 (out door) and indoor cassette type - 5 Nos, split type-1 Nos with refrigerant use R-410A/ 11.7 Kg, making servicing of the plants and making fully in serviceable condition of CNC secreatet of HQ SWAC at VSN make Daikin air conditioner complete all as specified and as directed.
Notes for Item No. 104:- (i) Spares required for replacement will be included in quoted rates. (ii) The rates quoted by the tenderer includes the cost of complete comprehensive service including as required visit the site at interval of 30 days to verify functioning of AC units till completion of contract as mentioned in Work Order No. 1. (iii) Servicing of the plant will be done of interval of 90 days during currrency of contract and when directed by Engr-in-Charge. (iv) Servicing/ repairs of AC units shall be carried out through the OEM only. (v) Contractor has to submit test certificate on completion of service/ repairs of AC units issued by service provider, contractor is responsible to proper functioning of AC, leakage and seapage repiare is sole responsibility of contracter quoted rates should incl leakage and seapage repair. (vi) this is Type 'A' AMC i.e. ALL IN ALL so that spares required will be provided by the contracter with in stipulated time period. (vii) complaints should be attended and rectified in 24 Hrs otherwise a penalty of rupees 2000.00 Rs per day will be recoverd from the contractor.
S&F in repair compressor as per code No RXYQ18TRY6 suitable for 18 ton ACs units complete all as specified and as directed.
S&F in repair in repair to replacement of inverter PCB of 18 ton VRF/ VRV type ACs complete all as specified and as directed.
Comprehensive maintenance and servicing of air conditioner of model DSA1052R1 packadge comprising of hermetic/ semi harmetically scrolled compressor indoor/ outdoor unit with refrigerant use R--22/ R-407 C R 410a, of capacity 8.75 TR, making servicing of the plants and making fully in serviceable condition installed at party hall of officer Mess HQSWAC - 04 Nos at VSN make Blue Star.
Notes for Item No. 107:- (i) Spares required for replacement will be measured and paid seperately. (ii) The rates quoted by the tenderer includes the cost of complete comprehensive service including replacement of spares as required and visit the site at interval of 90 days to verify functioning of AC units till completion of contract as mentioned in Work Order No. 1. (iii) Rates inclusive of replacement of parts during currrency of contract as and when directed by Engr-in-Charge. (iv) Servicing/ repairs of AC units shall be carried out through the OEM only. (v) Contractor has to submit test certificate on completion of service/ repairs of AC units issued by service provider contractor is responsible to proper functioning of AC, leakage and seapage repair is sole responsibility of contracter quoted rates should incl leakage and seapage repair. (vi) this is Type 'A' AMC i.e. ALL IN ALL so that spares required will be provided by the contracter with in stipulated time period. (vii) complaints should be attended and rectified in 24 Hrs otherwise a penalty of rupees 2000.00 Rs. per day will be recoverd from the contractor.
Comprehensive maintenance and servicing of VRF air conditioner of model MVRF06FC (out door) and indoor split type - 2 Nos. with refrigerant use R-410A/ 4.3 Kg, making servicing of the plants and making fully in serviceable condition of CNC secreatet of HQ SWAC at VSN make Bluestar air conditioner complete all as specified and as directed.
Notes for Item No. 108:- (i) Spares required for replacement will be included in quoted rates. (ii) The rates quoted by the tenderer includes the cost of complete comprehensive service including as required visit the site at interval of 30 days to verify functioning of AC units till completion of contract as mentioned in Work Order No. 1. (iii) Servicing of the plant will be done of interval of 90 days during currrency of contract and when directed by Engr-in-Charge. (iv) Servicing/ repairs of AC units shall be carried out through the OEM only. (v) Contractor has to submit test certificate on completion of service/ repairs of AC units issued by service provider, contractor is responsible to proper functioning of AC, leakage and seapage repiare is sole responsibility of contracter quoted rates should incl leakage and seapage repair. (vi) this is Type 'A' AMC i.e. ALL IN ALL so that spares required will be provided by the contracter with in stipulated time period. (vii) Complaints should be attended and rectified in 24 Hrs otherwise a penalty of rupees 2000.00 Rs. per day will be recovered from the contractor.
M&L for taking out electical connection of ICE making machine, opening and checking same, sand in to the work shope, and replacement of unserviceable part which ever is required, and making serviceable of the same and testing complete all as specified and as directed.
M&L for taking out water cooler of any size and capacity from existing site for repair and dismentaling of all components from cooler ,very care fully i.e. fan,motor, relay, capacitor and condensor etc, and repair of the same incl servicing and testing, re-fixing complete all as specified and as directed.
M&L for taking out air curtain from existing site for repair and dismentaling of all components from Air curtain, very care fully i.e. fan, motor, relay, capacitor and condensor etc. and repair and servicing of the same and refixing and testing complete all as specified and as directed.
S&F in repair PVC conduit suitable for 3.0 core/ 1.5 Sqmm/ 2.5 Sqmm wire incl all fittings for fixing at site complete all as specified and as directed.
S&F 3 pin 15 A top complete all as specified and as directed.
S&F 3 pin 5 A top complete all as specified and as directed.
S&F only casing capping patti suitable for 3.0 core/ 1.5 Sqmm/ 2.5 Sqmm wire complete all as specified and as directed.
S&F in repair AC top plug suitable for existing AC of capacity 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair refrigerator/ deep freezer/ water cooler gasket of suitable size as present at site complete all as specified and as directed. .
S&F in repair float valve of desert cooler complete all as specified and as directed.
S&F in repair stop cock of desert cooler complete all as specified and as directed.
S&F in repair PVC inlet pipe superior quality of desert cooler complete all as specified and as directed.
S&F in repair metallic frame for grass holding of superior quality of desert cooler complete all as specified and as directed.
S&F in repair PVC elbow and T of superior quality of desert cooler complete all as specified and as directed.
S&F in repair gas filter and NRV suitable for existing refrigerator and water cooler of cap 40-280 ltr complete all as specified and as directed.
S&F in repair drain pipe for water cooler complete all as specified and as directed.
S&F in repair non-adhesive tape roll for copper tubing of AC complete all as specified and as directed.
M&L for repair of AC water leakage, removing of drain tray cleaning of tray clear all blockage, and refixing the same and make proper insulation and tesing complete all as specified and as directed.
S&F in repair capacitor 2.5 Mfd + 5% 440 V MPP 'SH' complete all as specified and as directed.
S&F in repair capacitor 6 Mfd + 5% 440 V MPP 'SH' complete all as specified and as directed.
S&F in repair line reactor suitable for existing split AC of cap 1.5/ 2. TR complete all as specified and as directed.
S&F in repair contact sensor (indoor/ outdoor/ gas pipe/ temprature) suitable for existing split AC inverter type or non inverter tpe of cap 1.5/ 2.0 TR complete all as specified and as directed.
S&F in repair circuit plate with PCB inverter type of indoor/outdoor AC suitable for split AC of cap 2 TR complete all as specified and as directed.
Comprehensive maintenance and servicing of zero-B purifier up to 4 ltrs capacity in period of 45 days to make the purifier working to satisfactory condition complete all as specified and as directed. Note:- (a) Spares to be replaced will be measured and paid separately under respective items here in this schedule. (b) The rate quoted by the tenderer includes cost of maint/ serving of above said plant in a period of 03 months till the date of completion of work. (c) Rate inclusive of replacement of parts day during currency of contract as and when directed by Engineer-in-Charge.
Supply only PU cartridges.
Supply only BAC cartridges.
Supply only PVC filler bags as per existing capacity.
Comprehensive maintenance/servicing and testing of following RO plants including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set and dosing unit complete at so as to supply qualitative water at permissible level of TDS complete all as specified and as directed. Note:- (a) Spares required for replacement will measured and paid separately under respective items here-in-this schedule as 'supply only'. (b) The rate quoted by the tenderer includes cost of maint/ servicing of above said plant once in a period of 90 days till the date of completion of work. (c) Servicing should be done by OEM/ authorized agency and not by any local mechanic. (d) Contractor shall produce all purchase voucher and test certificate before submitted RAR. (e) Rate inclusive of replacement of parts at any day during currency of contract as and when directed by Engineer-in-Charge.
RO Plant 25 Ltrs capacity at Ahmedabad.
RO plant 50 ltrs capacity at hanger Ahmedabad.
RO Plant 25 Ltrs capacity at SWAC HQ Main Guard Room chiloda.
RO Plant 25 Ltrs capacity at CE AF Mess.
RO Plant 25 Ltrs capacity at Chiloda MT area.
RO Plant 25 Ltrs capacity at Chiloda CE single living area.
RO Plant 25 Ltrs capacity at GE AF Office area.
RO plant 50 ltrs capacity at 2 AFSR Sec 09.
Note:- Servicing should be done by OEM/ authorized agency and not by any local mechanic.
Supply only sediment filter as existing for 25/ 50 ltr RO plants.
Supply only RO membrane as existing for 50 Ltrs RO plant.
Supply only RO membrane 80 GPD as existing 25 Ltrs RO plant.
Supply only RO membrane Housing as existing 50/60 to 25 Ltrs RO plant.
Supply only carbon filter for 25/50 Ltrs RO plant.
S&F spum filter for 50/ 60 Ltrs RO plant complete all as specified and as directed.
S&F PF candle for 50/ 60 Ltrs RO plant complete all as specified and as directed.
Supply only 1/4 pipe for 25/ 50 Ltrs RO plant.
Supply only 1/2 pipe for 60 Ltrs RO plant.
Supply only low pressure/ high pressure DC switch for 25/ 50 RO plant.
Supply only stainer for 25/ 50 Ltrs RO plant.
Supply only anti scalant chemical.
Supply only chloroscope (range-0.1 ppm to 2.0 ppm).
Supply only dosing pump safety box with lock and key arrangement.
Supply only solenoid valve for 25/ 50 ltr RO plant.
Supply only booster pump 48 VDC suitable for 50/ 60 Ltrs RO plant.
Supply only pump 36 V DC suitable for 25 Ltrs RO plant.
Supply only SMPS power supply suitable for 25 Ltrs RO plant.
Supply only control module for 25/ 50 RO plant.
Comprehensive maintenance and servicing of RO/ Aquaguard purifier 8/ 10 Ltr capacity in a period of 4 months to make the purifier working to satisfactory conditions complete all as specified and as directed. Locations:- HQ SWAC – 01 No. and Duty Crew Room COMN FLT – 01 No. and Chiloda office area -12 Nos. and Billet area -10 Nos. Note:- (i) Service should be done by OEM/ authorized agency only. (ii) Contractor shall produce all purchase vouchers and test certificates or items before submitted RAR. (iii) Spares required for replacement will measured and paid separately under respective items here-in-this schedule as 'supply only'. (iv) Rate inclusive of replacement of parts at any day during currency of contract as and when directed by Engineer-in-Charge.
Supply only UF cartridges for 8/ 10 Ltrs RO.
Supply only sediment filter for 8/ 10 Ltr RO.
Supply only carbon filter for 8/ 10 Ltr RO.
Supply only pump for 8/ 10 Ltr RO.
Supply only membrane 75 GPD for 8/ 10 RO.
Supply only solenoid valve for 8/ 10 Ltr RO.
Supply only float cut off valve for 8/ 10 Ltr RO.
Supply only PVC suction tubing flexible type for dosing pump.
Supply only injection valve up to 7 Kg pressure for chlorine dosing unit.
Supply only PVC filter for chlorine dosing unit.
Supply only PVC diaphragm with 'O' ring head for chlorine dosing.
Supply only PVC head for chlorine dosing pump.
Supply only suction valve up to 5 Ltrs/ Hr for chlorine dosing pump.
Supply only discharge valve up to 5 Ltrs/ Hrs for chlorine dosing pump.
M&L for taking out old unserviceable PCB of water purifier carefully, taken to workshop for repair/ replacement and refixing the same and testing complete all as specified and as directed.
M&L for calcium based granular disinfectant for chlorination of water in 45 Kg packing complete all as specified and as directed.
M&L 100 Ltr capacity chlorine use white drum complete all as specified and as directed.
M&L 3/8" white suction/ discharge tubing for dosing pump. Make:- Cat No. MALT002 of Declibac or equivalent in make ALTOC/ RAMCO as aprroved by GE.
S&F ferrule 1/4" (PK of 24) for dosing pump complete all as specified and as directed. Make:- Cat No MCAK200 of Declibac or equivalent in make ALTOC/ RAMCO as aprroved by GE.
S&F in repair to replacement of zero-B puriline water purifier of 4 Ltrs capacity including all accessories like PU cartridge, connecting pipe etc complete all as specified and as directed by Engr-in-Charge.
S&F in repair/ replacement of sponge sediment fiter 10" complete all as specified and as directed.
S&F in repair in replacement of carbon block 10" complete all as specified and as directed.
S&F in repair/ replacement of auto level sensor complete all as specified and as directed.
S&F in repair/ replacement of Non return valve suitable for dosing pump complete all as specified and as directed.
S&F anti chlorine candle complete all as specified and as directed.
S&F anti scalant balls complete all as specified and as directed.
S&F in repair/ replacement of FR switch suitable for existing RO plant complete all as specified and as directed.
Dismantling, cleaning and over hauling of 0.25 HP centrifugal mono block pump set/ pressure booster pump set of the following capacities including rewinding of motor with appropriate super enameled copper wire of existing gauge, replacement of bearing - 02 Nos, including all connection and testing complete for following capacities:- (i) Replacement of bush (gland). (ii) Replacement of pump shaft. (iii) Replacement of impeller. (iv) Replacement of shaft sleeve. Note:- Suitable for Monoblock pump of RO plant only.
All as per Item No. 193 above, but 0.5 HP capacity pump complete.
M&L for collection of water sample from borewell & getting then tested from Govt. laboratry and furnishing test report, indicating chemical, and bactrological analysis including presrence of floride, TDS, Lead contents if any and submitted to the AGE E/M office and all as directed by Engineer-in-Charge.
S&F in repair cooling coil motor suitable for inverter type AC of cap 1.5/ 2.0 TR complete all as specified and as directed.
Comprehensive and maintenance servicing and testing of 400 Ltrs RO plant at Comm Flt Ahmedabad including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set and dosing unit complete at so as to supply qualitative water at permissible level of TDS complete all as specified and as directed. Note:- (i) Spares required for replacement will measured and paid separately under respective items here-in-this schedule as 'Supply only'. (ii) The rate quoted by the tenderer includes cost of maint/ servicing of above said plant once in a period of 90 days till the date of completion of work. (iii) Rate inclusive of replacement of parts at any day during currency of contract as and when directed by Engineer-in-Charge.
Supply only cartridge filter 400 Ltrs RO plant.
Supply only membrane 400 Ltrs RO plant.
Supply only 400 ltrs UV system RO plant.
Supply only 400 ltrs multi port valve.
Supply only 400 ltrs high/low pressure switch .
Supply only tubing suitable for 400 ltrs RO plant.
Supply only filter media 400 ltrs RO plant.
Supply only carbon media 400 ltrs RO plant.
Supply only solenoid valve 400 ltrs RO plant.
Supply only vertical pump.
Supply only UV/ LV lamp.
Supply only water controller sensor.
Supply only control panel.
Supply only raw water pump.
Supply only connector.
Supply only CTO filter for RO.
Supply only Bio Alkaine filter for RO.
Supply only vessal.
Supply only pressure tube.
M&L for plumbing work at 400 ltr RO plant for connection of tubing pipes, stopping of leakage removing of old unserviceable pipes etc. complete all as specified and as directed.
M&L for making of stand suitable as existing RO plant of cap 25 to 50 ltr , incl provn for fixing at wall or as per site requirement complete necessary plumbing and other workscomplete all as specified and as directed by Engr-in-Charge.
M&L to repair in replacement of digital LCD TDS meter tester water quality 0-1999 ppm PH test set filter purity mode with resolution 1 PPM complete all as specified and as directed. Make:- Noctronique model No. CB45154 or equivalent in make as approved by GE.
S&F in repair circuit plate with PCB inverter type of indoor/outdoor AC suitable for split AC of cap 1.5 TR.
Note:- Mechanic will collect complaint from Eng-in-charge/ JE E/M from any mode, complaints of cooling appliances (AC, Ref, Water Cooler, Deep Freezer) and RO should be attended and rectified within 24 Hrs otherwise a penalty of rupees 2000.00 Rs. per day per complaint will be recoverd from the contractor.
ARTI CONSTRUCTION
SATISH ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .