Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-Finance | L1 | Accepted-Finance L1 in BOQ1 sheet | |
| 2 | L2₹3.5 L+₹7,540 (2.23%)Accepted-Finance | L2 | Accepted-Finance L2 in BOQ1 sheet | |
| 3 | L3₹3.5 L+₹14,010 (4.15%)Accepted-Finance | L3 | Accepted-Finance L3 in BOQ1 Sheet | |
| 4 | L4₹3.5 L+₹15,475 (4.58%)Accepted-Finance | L4 | Accepted-Finance L4 in BOQ1 sheet | |
| 5 | L5₹3.6 L+₹21,585 (6.39%)Accepted-Finance | L5 | Accepted-Finance L5 in BOQ1 Sheet |
Tender Value
₹30.7 L
EMD Value
₹61,500
Closing Date
30 Oct 2024, 4:00 pmClosed
Executive Engineer,Elect. Division Vijaypur
Office of the Executive Engineer, Electric Division Vijaypur, JPDCL Jammu
CREATION OF SUB STATION (25/63 KVA) ALONG WITH HT/LT LINE ON TURNKEY BASIS UNDER PRI WORK 2024-2025 WITHIN THE JURISDICTION ELECTRIC DIVISION VIJAYPUR, JPDCL JAMMu
2024_PDD_259118_1
EDV/ 24 of 2024-2025 Dated 10-10-2024
Open Tender
Electrical Works
Turn-key
60 days
Samba District
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Executive Engineer, Electric Division Vijaypur
₹61,500
4 Jan 2025
10 Oct 2024
31 Oct 2024
11 Oct 2024
30 Oct 2024
11 Oct 2024
11 Oct 2024 - 30 Oct 2024
Amount
Laying of 11KV line 0.150 Km on 9Mtr PCC poles using ACSR Weasel Conductor at Mohalla Hakla near the H/o of Amanat Ali and others in w/No-3 of Village Badhori in Block Bar-Brahmana on Turnkey Basis.
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Laying & Stringing of ACSR (30mm²) Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire.
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti-Climbing Device with Clamps
Providing & installation of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 Mtr long through GI Strip.
Providing & Laying of Stone Pad (300 mm x 300 mm x 75 mm) for erection of 9Mtr PCC Pole.
Creation of 11/0.433kV, 25KVA, 3-phase Distribution Substation at Mohalla Hakla near the H/o of Amanat Ali and others in w/No-3 of Village Badhori in Block Bar-Brahmana on Turnkey Basis.
Supply, Installation & commissioning of 11/0.433 KV, 25 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, "BIS Marked" (Aluminium Wound) alongwith LV Cable Box having detachable Alumnium Gland plate including Transportation (As per latest amendments)
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 KV Horn Gap Set
Providing & Fixing of 50 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type alongwith 12 Nos Al. Thimble of size
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface.
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting ,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Providing & Fixing of 63 Amp TPN switch disconnector fuse unit
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum /pole
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing & Fixing of 11 KV Pin Insulator 12KV, 5KN, Lightening Impulse 75KV Positive and 80KV Negative, Creepage distance 320mm.
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Laying of 0.150 Km LT line on 8Mtr PCC poles using ACSR Weasel Conductor at Mohalla Hakla near the H/o of Amanat Ali and others in w/No-3 of Village Badhori in Block Bar-Brahmana on Turnkey Basis.
Supply, Transportation, Erection of 8 Mtr Long PCC Pole (WL-200 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Providing & Fixing of MS U-Clamp (duly painted with twio coats of Red Oxide and Al. paint) with Shackle Insulator (Polymer/Porcelain) along with Nut & Bolt of sorts
Supply, Laying & Stringing of ACSR Weasel Conductor through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of LT Line Spacers
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip
Providing of Stone Pad 300 mmx300mmx75mm
Description of Work / Item(s)
Amount
Laying of 11KV line 0.600 Km on 9Mtr PCC poles using ACSR Weasel Conductor at Dug Swankha of Vijaypur on Turnkey Basis
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Laying & Stringing of ACSR (30mm²) Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire.
Providing & Fixing of PG Clamps for 30mm² ACSR Conductor
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti-Climbing Device with Clamps
Providing & installation of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 Mtr long through GI Strip.
Providing & Laying of Stone Pad (300 mm x 300 mm x 75 mm) for erection of 9Mtr PCC Pole.
Providing & Fixing of Aluminium Jointing Sleeves
Providing & erection of Galvanized Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Creation of 11/0.433kV, 63KVA, 3-phase Distribution Substation at Dug Swankha of Vijaypur on Turnkey Basis
Supply, Installation & commissioning of 11/0.433 KV, 63 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, "BIS Marked" (Aluminium Wound) alongwith LV Cable Box having detachable Alumnium Gland plate.(As per latest amendments)
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing & Fixing of PVC Cable 120 mm² alongwith 12 Nos Al. Thimble of 120 mm²
Providing & Fixing of LT Distribution Box with100 Amp MCCB for incomer & switch fuse unit for Out Going Ckt.
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting ,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Wedge Connectors / PG Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Laying of 0.200 Km LT line on 8Mtr PCC poles using ACSR Weasel Conductor at Dug Swankha of Vijaypur on Turnkey Basis
Supply, Transportation, Erection of 8 Mtr Long PCC Pole (WL-200 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Providing & Fixing of MS U-Clamp (duly painted with twio coats of Red Oxide and Al. paint) with Shackle Insulator (Polymer/Porcelain) along with Nut & Bolt of sorts
Supply, Laying & Stringing of ACSR Weasel Conductor through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of LT Line Spacers
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip
Providing of Stone Pad 300 mmx300mmx75mm
Providing and fixing of Aluminium sleeves
Description of Work / Item(s)
Amount
Shifting of 0.700Km of HT line from Play field to Kathyal Pond towards the Land of Charan Dass at Village Diani of Samba on Turnkey Basis.
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Laying & Stringing of ACSR (30mm²) Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire.
Providing & Fixing of PG Clamps for 30mm² ACSR Conductor
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti-Climbing Device with Clamps
Providing & installation of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 Mtr long through GI Strip.
Providing & Laying of Stone Pad (300 mm x 300 mm x 75 mm) for erection of 9Mtr PCC Pole.
Providing & Fixing of Aluminium Jointing Sleeves
Providing & erection of Galvanized Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Description of Work / Item(s)
Amount
Laying of 11KV line 0.1 Km on 9Mtr PCC poles using ACSR Weasel Conductor near Sheela Banti Mandhir Bain in Village Glard of Village of Rajpura Samba on Turnkey Basis.
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Laying & Stringing of ACSR (30mm²) Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire.
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti-Climbing Device with Clamps
Providing & installation of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 Mtr long through GI Strip.
Providing & Laying of Stone Pad (300 mm x 300 mm x 75 mm) for erection of 9Mtr PCC Pole.
Creation of 11/0.433kV, 63KVA, 3-phase Distribution Substation near Sheela Banti Mandhir Bain in Village Glard of Village of Rajpura Samba on Turnkey Basis.
Supply, Installation & commissioning of 11/0.433 KV, 63 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, "BIS Marked" (Aluminium Wound) alongwith LV Cable Box having detachable Alumnium Gland plate.(As per latest amendments)
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing & Fixing of PVC Cable 120 mm² alongwith 12 Nos Al. Thimble of 120 mm²
Providing & Fixing of LT Distribution Box with100 Amp MCCB for incomer & switch fuse unit for Out Going Ckt.
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting ,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Wedge Connectors / PG Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Laying of 0.300 Km LT line on 8Mtr PCC poles using ACSR Weasel Conductor near Sheela Banti Mandhir Bain in Village Glard of Village of Rajpura Samba on Turnkey Basis.
Supply, Transportation, Erection of 8 Mtr Long PCC Pole (WL-200 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Providing & Fixing of MS U-Clamp (duly painted with twio coats of Red Oxide and Al. paint) with Shackle Insulator (Polymer/Porcelain) along with Nut & Bolt of sorts
Supply, Laying & Stringing of ACSR Weasel Conductor through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of LT Line Spacers
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip
Providing of Stone Pad 300 mmx300mmx75mm
Providing and fixing of Aluminium sleeves
Description of Work / Item(s)
Amount
Laying of 11KV line 0.500 Km on 9Mtr PCC poles using ACSR Weasel Conductor at Ward No-5 Chaliyari near the Land of Shiv Dutt Panchayat Chachwal of Rajpura Samba on Turnkey Basis.
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Laying & Stringing of ACSR (30mm²) Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire.
Providing & Fixing of PG Clamps for 30mm² ACSR Conductor
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti-Climbing Device with Clamps
Providing & installation of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 Mtr long through GI Strip.
Providing & Laying of Stone Pad (300 mm x 300 mm x 75 mm) for erection of 9Mtr PCC Pole.
Providing & Fixing of Aluminium Jointing Sleeves
Providing & erection of Galvanized Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Creation of 11/0.433kV, 63KVA, 3-phase Distribution Substation at Ward No-5 Chaliyari near the Land of Shiv Dutt Panchayat Chachwal of Rajpura Samba on Turnkey Basis.
Supply, Installation & commissioning of 11/0.433 KV, 63 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, "BIS Marked" (Aluminium Wound) alongwith LV Cable Box having detachable Alumnium Gland plate.(As per latest amendments)
Supply, Transportation, Erection of 9 Mtr Long ST Pole (ST-410 SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc. Including painting with two coats of Red Oxide and Al. Paint for smooth surface.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing & Fixing of PVC Cable 120 mm² alongwith 12 Nos Al. Thimble of 120 mm²
Providing & Fixing of LT Distribution Box with100 Amp MCCB for incomer & switch fuse unit for Out Going Ckt.
Providing of Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV with Fitting ,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Wedge Connectors / PG Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
M/S HI-TECH ELECTRICAL CONSTRUCTIONS AND SUPPLIERS (BID ID -2199858)
M/S COMBINE GROUP OF ENGINEERS (BID ID -2201835)
BALA JI CONSTRUCTIONS (BID ID -2202680)
M/S VINAYAK ENGINEERS (BID ID -2200479)
M/S PIONEER ENGINEERS (BID ID -2197099)
VEENA CONSTRUCTION CO. (BID ID -2176142)
M/S COMBINE GROUP OF ENGINEERS (BID ID -2201835)
M/S VINAYAK ENGINEERS (BID ID -2200479)
M/S HI-TECH ELECTRICAL CONSTRUCTIONS AND SUPPLIERS (BID ID -2199858)
BALA JI CONSTRUCTIONS (BID ID -2202680)
VEENA CONSTRUCTION CO. (BID ID -2176142)
M/S VINAYAK ENGINEERS (BID ID -2200479)
M/S COMBINE GROUP OF ENGINEERS (BID ID -2201835)
BALA JI CONSTRUCTIONS (BID ID -2202680)
M/S HI-TECH ELECTRICAL CONSTRUCTIONS AND SUPPLIERS (BID ID -2199858)
M/S COMBINE GROUP OF ENGINEERS (BID ID -2201835)
M/S PIONEER ENGINEERS (BID ID -2197099)
BALA JI CONSTRUCTIONS (BID ID -2202680)
M/S HI-TECH ELECTRICAL CONSTRUCTIONS AND SUPPLIERS (BID ID -2199858)
M/S VINAYAK ENGINEERS (BID ID -2200479)
M/S PIONEER ENGINEERS (BID ID -2197099)
M/S COMBINE GROUP OF ENGINEERS (BID ID -2201835)
BALA JI CONSTRUCTIONS (BID ID -2202680)
M/S HI-TECH ELECTRICAL CONSTRUCTIONS AND SUPPLIERS (BID ID -2199858)
M/S VINAYAK ENGINEERS (BID ID -2200479)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .