Loading…
Loading…
Tender Value
₹25.4 L
EMD Value
₹60,000
Closing Date
6 Mar 2025, 5:00 pmClosed
Krishna Bhagya Jala Nigam Limited
AME OF KONGANDI LIFT IRRIGATION FOR THE YEAR 2024-25 Material and Manpower
KBJNL/2024-25/LI/WORK_INDENT1361/CALL-2
KBJNL/2024-25/LI/WORK_INDENT1361/CALL-2
Open
Lift Irrigation Scheme
Electronic Documents, First(One Cover)
KBJNL Division SBC O and M Division Khanapur
₹640
₹60,000
18 Sept 2026
27 Feb 2025
3 Mar 2025
AME OF KONGANDI LIFT IRRIGATION FOR THE YEAR 2024-25 Material and Manpower
Engineer- Grade-II DIPLOMA Mechanical for Kongandi LIS Head Work for over all supervision Operation and Maintanance of Pump House and 33/6.6 KV Sub-Station, Complete the specification with all lead a...
Engineer- Grade-II DIPLOMA Electrical for Kongandi LIS Head Work for over all supervision Operation and Maintanance of Pump House and 33/6.6 KV Sub-Station , Complete the specification with all lead ...
Pump Operators- ITI/ITC/JOC/WIREMAN for Kongandi LIS Head Work for over all supervision, Operation and Maintanance of Pump House and 33/6.6 KV Sub-Stationa , Complete the specification with all lead ...
Heavy Mazdoors for cleaning of ARBC and Kongandi LIS Head works and 33/6.6 KV Sub-station , Complete the specification with all lead and lift as per directions of Engineer in charge
Watchmen for security of Kongandi LIS Head Works for security and surveilance of Pump Houses and 33/6.6 KV Sub-Station , Complete the specification with all lead and lift as per directions of Engin...
Sweepers for ARBC and Kongandi LIS Head Works for security and surveilance of Pump Houses and 33/6.6 KV Sub-Station , Complete the specification with all lead and lift as per directions of Engineer-...
Transformer oil testing for Dielectric strength (BDV) of power Transformers and auxiliary transformers at Kongandi LIS head , Complete the specification with all lead and lift as per the direction of...
Transformer oil testing for Neutralization number (Acidity) of power Transformers and auxiliary transformers Kongandi headwork , Complete the specification with all lead and lift as per the direction...
Transformer oil testing for Moisture Content (PPM) of power Transformers and auxiliary transformers at Kongandi LIS headwork , Complete the specification with all lead and lift as per the direction ...
Transformer oil testing for Interfacial tension of power Transformers and auxiliary transformers at Kongandi headwork , Complete the specification with all lead and lift as per the direction of Engi...
Transformer oil testing for Flash point of power Transformers and auxiliary transformers at Kongandi headwork , Complete the specification with all lead and lift as per the direction of Engineer Inc...
Transformer oil testing for Di-electric dissipation factor (Tan Delta) of power Transformers and auxiliary transformers at Kongandi headwork , Complete the specification with all lead and lift as per...
Transformer oil testing for Resistivity of power Transformers and auxiliary transformers at Kongandi headwork , Complete the specification with all lead and lift lift and as per the direction of En...
Transformer oil testing for Dissolved gas Analysis (DGA) of power Transformers and auxiliary transformers at Kongandi headwork , Complete the specification with all lead and lift as per the directio...
Testing & Commissioning: 33/6.6 KV panel indoor (Capacitor Bank with reactors) , Complete the specification with all lead and lift as per the direction of Engineer Incharge
Wiring: Identification of 8 MVA, 33/6.6 kV at Kongandi LIS headwork Power Transformers Inspection of wires and ferrules.Inspection of wiring of protectivedevices, cooling fans, oil flowpumps, OLTC,...
Fire Fighting equipments with necessary mounting stands.Foam extinguishing type.9 litre capacityas , Complete the specification with all lead and lift per directions of Engineer-in-Charge.
BATTERY CHARGER : 48/24 V Installing, assembling, filling of acid, wiring, assisting, test-charging and discharging Battery set.Complete the specification with all lead and lift per directions of Eng...
Erection of Battery Charger and wiring 48/24 V, Complete the specification with all lead and lift per directions of Engineer-in-Charge.
Filling of oil to the main tank and OLTC tank, filtering the oil including filtering till attainment of prescribed BDV valves including labour, tering equipment along with accessories.Complete the sp...
Erection of CTs and PTs and wiring including move,ment from point of unloading to mthe point of erection.Complete the specification with all lead and lift per directions of Engineer-in-Charge.
1. Ratio Test 2. SC test 3. Excitation test 4. Magnetic Balance test
5. Vector group test 6. Induced High voltage test
7. OLTC operation 8. Protective Devices operation Checks
Supply and topping EHV Grade Transformer Oil-New , Complete the specification with all lead and lift per directions of Engineer-in-Charge.
Repair capacitor bank breakers. Complete the specification with all lead and lift per directions of Engineer-in-Charge.
Repair soft starter panel Complete the specification with all lead and lift per directions of Engineer-in-Charge.
K Air Valve PN 1.6 + accessories-100 mmComplete the specification with all lead and lift per directions of Engineer-in-Charge.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .