Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAdmitted-Finance | ₹3.3 L | L1 | Admitted-Finance |
| 2 | L2₹4.1 LAdmitted-Finance | ₹4.1 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ASHTAPAD INFRASTRUCTURE L1 | PANCHAL MEETKUMAR SUBHASHBHAI L2 |
|---|---|---|---|---|---|
| 1.00 | Providing and fixing precoated galvanised iron profile sheet (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05%, total coated thickness with zinc coating 120 gsm as per I.S. 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyster top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scraches while transportation and should be supplied in single length upto 12 metre or as required by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer-in-charge. (Note:- Clear measurements of length and width shall be measured for payment. Nothing extra shall be paid for overlapping of G.I sheet.) | 130 | Sqm | 1,620 ₹2.1 L | 1,800 ₹2.3 L |
| 2.00 | Dismantling of existing G.I plain or profile sheet of BTS roof carefully and stacking the material within 50 m lead as per the direction of Engineer-in-charge. | 130 | Sqm | 450 ₹58,500 | 700 ₹91,000 |
| 3.00Supplying and applying injectible silicon sealent in the joints, cavities, alround AC and edges of panel of prefabricated shelters in horizontal and vertical direction with pressure gun. Item includes sealing of small holes, hair cracks and thin unused gap etc. The silicon sealant shall be of standard manufacturer as approved by Engineer-in-charge and having resistance against temperature variation. | |||||
| 3.01 | Type - I Shelter (3.10 x 2.2 m) | 10 | Nos | 4,500 ₹45,000 | 6,000 ₹60,000 |
| 4.00 | Providing and fixing 0.50 mm thick plain G.I. Sheet roofing fixed with galvanised iron rivets all complete as per the direction of Engineer-in-charge. | 20 | Sqm | 1,350 ₹27,000 | 1,500 ₹30,000 |
| 5.00 | Credit of existing dismantled rusted G.I. Plain or profile sheet of BTS roof as per the direction of Engineer-in-charge. | 130 | Sqm | 60 -₹7,800 | 50 -₹6,500 |
Tender Value
₹3.7 L
EMD Value
₹7,304
Closing Date
8 Apr 2026, 6:00 pmClosed
EE civil Vadodara
First floor, BSNL TE buidling Kishanwadi Vadodara
Repairing and Maintenance of BSNL BTS shelter of NBSNL/BSNL sites for sealing of leakage at different floor height and different stations (13 Locations) in Vadodara Rural and Chhota Udepur SDCA (2nd call )
2026_BSNL_273448_1
66/BSNL/EE/CD/VDR/2025 26
Open Tender
Civil Works
30 days
Chhotaudepur
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Accounts Officer (Cash) The PGMTD, BSNL Vadodara
₹7,304
16 Apr 2026
30 Mar 2026
10 Apr 2026
30 Mar 2026
8 Apr 2026
30 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Providing and fixing precoated galvanised iron profile sheet (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05%, total coated thickness with zinc coating 120 gsm as per I.S. 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyster top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scraches while transportation and should be supplied in single length upto 12 metre or as required by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer-in-charge. (Note:- Clear measurements of length and width shall be measured for payment. Nothing extra shall be paid for overlapping of G.I sheet.) | ||||||
| 2Dismantling of existing G.I plain or profile sheet of BTS roof carefully and stacking the material within 50 m lead as per the direction of Engineer-in-charge. | ||||||
| 3Supplying and applying injectible silicon sealent in the joints, cavities, alround AC and edges of panel of prefabricated shelters in horizontal and vertical direction with pressure gun. Item includes sealing of small holes, hair cracks and thin unused gap etc. The silicon sealant shall be of standard manufacturer as approved by Engineer-in-charge and having resistance against temperature variation. | ||||||
| 3.01 | Type - I Shelter (3.10 x 2.2 m) | - | Nos | - | - | BI01010001010000000000000515BI0100001125 |
| 4Providing and fixing 0.50 mm thick plain G.I. Sheet roofing fixed with galvanised iron rivets all complete as per the direction of Engineer-in-charge. | ||||||
| 5Credit of existing dismantled rusted G.I. Plain or profile sheet of BTS roof as per the direction of Engineer-in-charge. | ||||||
stage.html
html • 0.03 MB
technical_319259.pdf
techsummary_319259.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.61 MB
Tendernotice_2.pdf
PDF • 0.10 MB
Tendernotice_3.pdf
PDF • 0.37 MB
NIT66location13shelterEtender2nd.pdf
Tender Documents • 1.59 MB
DECLARATIONSTENDERERS66.pdf
Other Document • 0.36 MB
APPLICATIONTENDER66.pdf
Other Document • 0.08 MB
BOQ_319259.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid