Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹18.4 L+₹4.4 L (30.9%)Rejected-AOC | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹24.0 L+₹9.9 L (70.1%)Rejected-AOC | L3 | Rejected-AOC Not lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
11 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR / REPLACEMENT AND SERVICING OF SPLIT /WINDOW TYPE AC AND ALLIED WORKS AT AF STN JODHPUR
2022_MES_524295_1
8520/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Jodhpur
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹40,000
Yes
17 Jun 2022
16 May 2022
13 Jun 2022
16 May 2022
11 Jun 2022
30 May 2022
60 days
Amount
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Reciprocating compressor) 1.5 Tonne capacity, single phase, 230 volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage rectification , and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Rotary compressor) 1.5 Tonne capacity, single phase, 230 volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage rectification , and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Inverter compressor) 1.5 Tonne capacity, single phase, 230 volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage rectification and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407 C/R-410 A and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Reciprocating compressor) 2 Tonne capacity, single phase, 230 volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage rectification , and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Rotary compressor) 2 Tonne capacity, single phase, 230 volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage rectification , and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Inverter compressor) 2 Tonne capacity, single phase, 230 volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage rectification and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407 C/R-410 A and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for Water Jet servicing of Split type AC of 1.5/2.0 Tonne capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge.
Material & labour for Water Jet servicing of WINDOW TYPE AC's of 1.5/2.0 Tonne capacity (complete unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the complete unit from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge. Note for Srl Item No.7 & 8 above :- The contractor shall at his own cost arrange water for servicing purpose and also clean the wall & Floor surfaces after servicing and make it neat and tidy to the entire satisfaction of Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 2.5 MFD, 230 volts, 50 HZ suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 4 MFD, 230 volts, 50 HZ suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 6 MFD, 230 volts, 50 HZ complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 45 MFD, 230 volts, 50 HZ complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 50 MFD, 230 volts, 50 HZ complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Starting capacitor of capacity 80-100 MFD, 230 volts, 50 HZ complete all as specified & directed by the Engineer-in-Charge.
Taking down existing condensing fan motor from the unit and Material & labour for rewinding of condensing fan motor of suitable capacity for 1.5/2.0 Tonne (split type/window type ACs) of any make with super enameled copper winding wire of existing gauge including replacement of the motor bushes and shaft and testing on load for the entire satisfaction of Engineer-in-Charge.
Taking down existing fan blower motor of cooling unit and Material & labour for rewinding of fan blower motor of cooling unit of suitable capacity for 1.5/2.0 ton(split type/window type ACs) of any make with supper enameled copper winding wire of existing gauge including replacement of the shaft and bushes and testing on load for the entire satisfaction of Engineer-in-Charge.
Supply & fixing in repairs condensing fan DC motor for 1.5/2.0 Tonne capacity split type AC (For outdoor unit) of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condensing fan AC motor for 1.5/2.0 Tonne capacity split type AC (For outdoor unit) of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & Fixing in replacement Blower suitable (for indoor unit) for split type AC of capacity 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs fan blades (ISI Marked) of suitable size for outdoor unit of 1.5/2.0 Tonne Split type AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour for repairing of PCB control card suitable for 1.5/2.0 Tonne capacity split /window type AC, single phase and making the PCB control card functional complete to the entire satisfaction of Engineer-in-Charge.
Material & labour for reparing of PCB control card suitable for 1.5/2.0 Tonne capacity Invertor type split/ window AC, single phase indoor and making the PCB control card functional complete to the entire satisfaction of Engineer-in-Charge.
Material & labour for reparing of PCB control card suitable for 1.5/2.0 Tonne capacity Invertor type split/ window AC, single phase outdoor and making the PCB control card functional complete to the entire satisfaction of Engineer-in-Charge.
Supply only in replacement of Remote suitable for 1.5/2.0 Tonne capacity split AC of original make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs capillary copper tube (ISI Marked) of suitable size for split /window type AC capacity 1.5/2.0 Tonne complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condenser coil for window type AC 1.5/2.0 Tonne capacity of any make including charging of gas R-22/R407C complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs water tray (ISI Marked) for Indoor unit of split AC of any capacity and make AC as approved by Engineer-in-Charge.
Supply & fixing in repairs of relay of split type AC of any make and any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs thermostat suitable for any make of window type AC 1.5 Tonne capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs single pole contactor suitable for split type AC capacity 1.5/2.0 Tonne complete all as specified & directed by the Engineer-in-Charge.
Material & labour for finding out the leakage with the pressure test of the condenser or cooling coil of window type AC's/split type AC's of 1.5/2.0 Tonne capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering with and including charging the gas R-22 and testing the AC to the entire satisfaction of Engineer-in-Charge.
Material & labour for finding out the leakage with the pressure test of the condenser or cooling coil of window type AC's/split type AC's of 1.5/2.0 Tonne capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering with and including charging the gas R-410A/R-407C and testing the AC to the entire satisfaction of Engineer-in-Charge.
Supply, laying and commissioning of cable in replacement PVC sheathed cable with multistranded copper conductor of size 2.5 sqmm 3 core complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs copper tube (ISI Marked) of size ⅝” dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs copper tube (ISI Marked) of size ¼” dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size ⅝" dia of split type AC's any capacity complete all as specified & directed by the Engineer-in-Charge.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size¼" dia of split type AC's any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs flexible drain pipe (PVC BRAIDED hose pipe) of size 15 mm dia, for split type AC any capacity and any make complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs air filter element suitable for split type AC 1.5/2.0 Ton capacity any make complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs wall mounting bracket stand suitable for 1.5/2.0 tonne capacity outdoor unit of split AC including necessary dash through bolt of siutable sizecomplete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs floor mounted bracket AC stand certified special coated super 50cm x 8 cm shelf bracket suitable for 1.5/2.0 ton outdoor unit capacity including necessary dash through bolt of siutable size complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Voltage Stabilizer of capacity 05 KVA, for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % complete all as specified & directed by the Engineer-in-Charge.
Material & labour in replacement for sub main wiring with two runs of PVC insulated unsheathed multi stranded copper conductor FRLS cable 4 Sqmm 1100 volt grade drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm,concealed in wall (including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc.) including 2.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire including taking out / down the existing unserviceable sub main wiring with conduit complete all as specified and directed by the Engineer in Charge. Note :- Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Material & labour in replacement for sub main wiring with two runs of PVC insulated unsheathed multi stranded copper conductor FRLS cable 2.5 Sqmm 1100 volt grade drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm,concealed in wall (including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc.) including 1.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire including taking out / down the existing unserviceable sub main wiring with conduit complete all as specified and directed by the Engineer in Charge. Note :- Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Supply & fixing in repairs sheet metal enclosure SPN with two pin and earth plug socket with & including 20Amps MCB 'C' curve single pole 240 Volt AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB SP 25 Amp, ‘C’ curve type, 10 KA complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repair MCB SPN 25 Amp ‘C’ curve type, 230 volts, 10 KA complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB SP 20 Amp ‘C’ curve type, 230 volts, 10 KA complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement 3 pin metal clad plug top cap 20 Amp AC 240 Volts 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement 3 pin socket 20 Amp AC 240 Volts 50 Hz for AC metal clad box complete all as specified & directed by the Engineer-in-Charge.
Dismantling of split AC/window AC any capacity with proper pumpdown from the site and diposit to MES work shop for major repair works complete all as specified & directed by the Engineer-in-Charge.
Fixing & commisioning only of split/window type AC capacity 1.5/2.0 Tonne (AC dismantled from item No.51 above shall be reused) including testing after installation complete all as specified & directed by the Engineer-in-Charge. Note :- Copper tubing if required shall be measured & paid seprately.
Supply & fixing in replacement Display card of Indoor unit of Split AC capacity 1.5 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Display card of Indoor unit of Split AC capacity 2 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Complete Indoor unit with remote of Split AC capacity 1.5 Tonne complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Complete Indoor unit with remote of Split AC capacity 2 Tonne complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs L & key valve (ISI Marked) of size 5/8" for condenser unit split type AC 1.5/2.0 Tonne , including proper leak test check shall be carried after replacement of valve complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs L & key valve (ISI Marked) of size 1/4" for condenser unit split type AC 1.5/2.0 Ton , including proper leak test check shall be carried after replacement of valve complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs of flair nut size 5/8" and 1/2"dia for split type AC of any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs of flair nut size 3/8" and 1/4" dia for split type AC of any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs of dead nut size 1/4 '' dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour for filling of Refrigerant Gas R-22 complete all as specified & directed by the Engineer-in-Charge.
Material & labour for filling of Refrigerant Gas R-410A/407/134 complete all as specified & directed by the Engineer-in-Charge.
Supply & Fixing in repairs AC motor suitable for Indoor unit blower of split type AC 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & Fixing in repairs DC motor suitable for Indoor unit blower of split type AC 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Material & labour for sealing the bore holes of walls with expandable polyurethane foam complete all as specified & directed by the Engineer-in-Charge. Note :- Only existing Holes in walls to be sealed.
Supply & Fixing in repairs room temperature sensor of split/window AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement of complete Indoor unit of 1.5 Ton inverter AC including dismantling the existing indoor unit and fixing the new unit including all cable connections and testing the same complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement of complete Indoor unit of 2 Ton inverter AC including dismantling the existing indoor unit and fixing the new unit including all cable connections and testing the same complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement of complete outdoor unit of 1.5 Ton inverter AC including dismantling the existing outdoor unit and fixing the new unit including gas charging, all cable connections and testing the same complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement of complete outdoor unit of 2 Ton inverter AC including dismantling the existing outdoor unit and fixing the new unit including gas charging, all cable connections and testing the same complete all as specified & directed by the Engineer-in-Charge.
Material & labour in repair for fabrication of canopy stand for outdoor split type AC unit of mild steel angle iron with mild steel plate covering at top including cutting, made to shape, welding, with locking arrangement including painting of all steel surfaces with two coat of synthetic enamel paint over one coat of red oxide primer and fixing the same in PCC block, including dismantling the old unserviceable rusted cracked canopy stand complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing scroll compressor three phase 4.5 KW model no JT170G-KYE Make DAIKIN for VRV unit including taking out the old compressor from existing VRV unit and fixing the new with necessary copper pipe connection including gas charging R-410A and testing the same in presense of Engineer-in-Charge complete all as specified and directed by the Engineer-in-Charge. Note :- R-410A will be paid in separate items.
Supply & fixing in replacement S.G.I. body fire brigade inlet having 02 gun metal 63 mm male instantaneous inlet connected with existing hydrant post with all accessories complete all as specified & directed by the Engineer-in-Charge.
Shiv Shakti Enterprises
M/s Pankaj Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .