Loading…
Loading…
Tender ID
Tender Value
₹11.2 L
EMD Value
₹22,350
Closing Date
20 Mar 2026, 3:00 pmClosed
Execvutive Engineer
Executive Engineer Mechanical Division
Providing Installation commissioning of 4TR air Conditioning System in Pragna Bhavan 202526
2026_CEPWD_71185_1
91_EE_DNIeT_MECH_202526
Open Tender
Electrical Works
Works
90 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹22,350
3 Mar 2026
3 Mar 2026
20 Mar 2026
3 Mar 2026
20 Mar 2026
3 Mar 2026
Providing of Vertical split AC unit of cooling capacity not less than 13000 watt (±10% variation) equivalent to approximately 46,000 BTU/hr (±10%) with hermitically sealed compressor operating on R22 / R-410A / non-CFC equivalent refrigerants, suitable for floor mounting, suitable for operation on 3 Phase AC supply capable of performing A) Cooling, B) Dehumidify, C) Air circulation, D) Filtering, etc., complete as per direction of Engineer-in-Charge.
Installation and commissioning of vertical split AC unit with vaccumising, nitrogen pressure testing, first charge of refrigerant including providing Refrigerent & cable connection from MCB to Outdoor/indoor etc. (upto 3mtr) complete as per direction of the Engineer in Charge.
Providing & installation of Hard Drawn copper piping with insulation for vertical split AC as per direction of the Engineer-In-Charge. ¾" OD/applicable OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge.
Providing & installation of Hard Drawn copper piping with insulation for vertical split AC as per direction of the Engineer-In-Charge. ½" OD/ applicable OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge.
Providing hard UPVC pipe of best quality of suitable diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.
Providing, fitting & fixing of cradle/suitable structure (Base) made of M.S, nuts & bolts etc. i/c painting, fitting, fixing, grouting for placement of outdoor unit complete for vertical split AC as per direction of the Engineer-In-Charge.
Providing, fitting & fixing of suitable structure (Base) made of M.S, nuts & bolts etc. i/c painting, fitting, fixing grouting for placement of indoor unit, the M.S base should be enclosed by 12 mm water proof ply with formica pasting/ACP sheet complete for vertical split AC as per direction of the Engineer-in-charge.
providing & fitting fixing of additional (beyond 3 mtr) electric control cable (5C X 4.00 mm) suitable for connection between MCB to out door unit /Indoor unit etc complete as per direction of the Engineer in charge .
Providing additional refrigerant gas to the AC unit as per direction of Engineer -in- charge
Providing and fitting-fixing of VI pad for outdoor unit for Vertical split AC unit as per direction of the Engineer in Charge .
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
DNIeT.pdf
Tender Documents • 3.13 MB
BOQ_72434.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .