Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 CrAccepted-AOC | ₹4.4 Cr Quoted ₹4.5 Cr | L1 | Accepted-AOC Being Lowest Bidder |
| 2 | L2₹4.8 Cr+₹22.8 L (5.02%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹4.8 Cr+₹22.8 L (5.02%) | L2 | Rejected-Finance Being other than lowest bidder |
| 3 | L3₹4.9 Cr+₹34.0 L (7.50%)Rejected-Finance | ₹4.9 Cr+₹34.0 L (7.50%) | L3 | Rejected-Finance Being other than lowest bidder |
| 4 | L4₹5.0 Cr+₹44.3 L (9.77%)Rejected-Finance | ₹5.0 Cr+₹44.3 L (9.77%) | L4 | Rejected-Finance Being other than lowest bidder |
| 5 | L5₹5.1 Cr+₹57.7 L (12.7%)Rejected-Finance | ₹5.1 Cr+₹57.7 L (12.7%) | L5 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹4.5 Cr
EMD Value
₹5.3 L
Closing Date
22 Dec 2021, 6:00 pmClosed
CE Jodhpur Zone
HQ CE Jodhpur Zone
ADDN ALTN AND SPECIAL REAIRS OF SELECTED OLD MD ACCN AT AHMEDABAD CANTT (JOB NO 01/AMWP/11DIV/ADI/Q3/2021-22)
2021_MES_489462_1
800558/AMD/2021-22/E8
Open Tender
Civil Works
Item Rate
540 days
Ahmedabad
Please refer tender documents
9 documents required · 9 mandatory
₹2,000
GE (A) Ahmedabad
₹5.3 L
Yes
HQ CE Jodhpur Zone
9 Feb 2022
20 Nov 2021
24 Dec 2021
20 Nov 2021
22 Dec 2021
15 Dec 2021
30 Nov 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing from site and rubbish off the premises.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for (roof padding/sunken floor) and removing from site all as specified and directed.
M&L for roughening surface of old concrete by picking, sweeping clean and washing down with water to remove all loose dust etc. for brushing neat cement slurry with 3.00 kg of cement per sqm.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors.
M&L for non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular) in floors etc. area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15 mm thick screed bed in or bedding layer CM 1:4.
M&L for glazed ceramic tiles, coloured, 350x250x7mm/450x300x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:3 on brick or concrete surfaces.
M&L for non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular) in floors etc. area of each tile exc. 0.18 sqm but n. exc. 0.38 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1:4.
M&L for non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular) area of each tile exc. 0.18 sqm but n. exc. 0.38 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:3 on brick or concrete surfaces.
M&L for vitrified ceramic light shade tiles 9 to 10 mm thick(square/rectangular) polished, area of each tile n. exc.0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1:4.
M&L for vitrified ceramic light shade tiles 9 to 10 mm thick(square/rectangular) polished, area of each tile n. exc.0.36 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:3 on brick or concrete surfaces.
M&L for machine cut kota stone slab 18-20 mm thick of size as directed in flooring, treads of steps etc including half round edging/molding over and including 20 mm thick cement screed in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L for kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick rendering in CM 1:3 on stone masonry surfaces and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
Demolition of stone slabs and tiles of any description or thickness in floors and aprons etc. laid, bedded and pointed in any mortar and removing from site all as specified and directed.
M&L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over and including 20 mm thick screed in CM 1:3 including rounding of all exposed edges.
M&L for 18 to 20 mm thick marble work of Udaipur green marble (table rubbed and polished) in cooking platform, pillars, window-cills, jambs, steps and like in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over and including 20 mm thick screed in CM 1:3 including rounding of all exposed edges.
Taking down/removing existing unserviceable roof treatment by removing tarfelt and cement plaster of any description etc.) and removing from site all as specified and directed and cleaninig of top surface of cement concrete flushing out junction of parapet walls and washing down with water etc.
M&L for cement concrete 1:2:4 type B-0 mix (12.5 mm graded stone aggregate) in padding over roof of any thickness.
M&L for 10 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement complete all as specified. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”
Supply only liquid water proofing compound.
M&L for applying roof treatment on top of roof with APP modified membrane (minimum 3 mm thick) weight not less than 3.00 Kg/sqm and reinforced with non-woven polyster reinforcement/mat (centre core) with polythene finish, laid by torch application method with overlaps 150 mm on length side and 100 mm on the width side as per manufacturer’s instructions over a coat of approved cold applied bituminous oil based primer (IS- 3384) @ 300 gm/sqm and applying two coats of aluminium paint 0.20 litre/sqm complete all as specified and as directed by Engineer-in-Charge.
Dismantling water tanks of any description, exc. 250 & n. exc. 500 litres capacity and removing from site.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top), white in colour outside and inside, hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes .
Disconnecting existing tanks, exc. 250 ltrs and n. exc. 500 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required, reconnecting and refixing in position including cleaning and removing all scale and dirt, etc., from tanks and from mouths of circulating pipes etc and removing old unserviceable ball valve.
Dismantling water tanks of any description, exc. 500 & n. exc. 1000 litres capacity and removing from site.
S&F 1000 litres capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top), white in colour outside and inside, hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes .
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in floors any thickness in platform for PVC tank as directed.
S&F 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms.)
M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exc. 10 cm girth.
Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removing from site.
Supply and laying 15 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Refixing old steel tubing, 15 mm bore, and connections in new or old position (Walls, ceiling, floors, etc.) NOTE :- Steel tubes obtained from item No. 29.00 above shall be used under this item.
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removing from site.
Supply and laying 20 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Refixing old steel tubing, 20 mm bore, and connections in new or old position (Walls, ceiling, floors, etc.) NOTE :- Steel tubes obtained from item No. 32.00 above shall be used under this item.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.
M&L for rendering 5 mm thick in CM 1:4 mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, over and including 10 mm thick rendering in CM 1:6 on brick work or concrete surfaces. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”
S&F butt hinges, medium weight, cold rolled, mild steel of size 100 mm.
M&L for rendering 10 mm thick in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted, over and including a coat of 2 mm thick wall care putty all as directed.
M&L for complete removal of existing treatment from walls and applying two coats of distemper oil emulsion, white or tinted, over and including a coat of 2 mm thick wall care putty all as directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash.
M&L for complete removal of existing treatment from walls and applying three coats of white wash on walls all as directed.
M&L guniting for shortcrete 1 :2 (CM) mixed with epoxy resin and hardner (manufactured by FOSROC/MC BAUCHEMIC /CICO/PIDILITE)@ 2% by weight of cement in equal proportion using short crete pumps and allied equipment,in thickness 30 mm all as per manufactureres instruction.(Upto 12 mtr height) including necessary chiping/taking down loose concrete all as directed.
S&F welded steel wire fabric n. exc. 4 kg per sqm, fixed complete to wood or steel members.
M&L for rendering 5 mm thick in CM 1:3 on concrete surfaces in ceiling (facia/ceiling/edging of chajjas and roof projection) including finishing even and smooth without using extra cement.
M&L for preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash.
M&L for complete removal of existing treatment from ceiling and applying three coats of white wash on ceiling all as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed.
M&L for brick work with sub class 'B’ bricks using old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B’ bricks using old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM 1:6.
M&L for PCC 1:2:4 type B1 using 20 mm stone aggregate in lintels up to 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
M&L for 15 mm thick rendering on vertical side of sunken floor of brick/ concrete surfaces in CM (1:3) mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement and finished even and smooth without using extra cement complete all as specified. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L for PCC 1:1½:3 nominal mix type A-0 using 12.5 mm graded stone aggregate mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement on bottom of sunken portion with slope towards spout including applying two coat of polymeric base chemical in the top surface of PCC and side of sunken portion complete all as specified. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”
M&L for cement concrete (1:5:10) type E-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete/sunken floors all as specified and directed.
Taking up or down steel tubing 50 mm bore and connections including cleaning for refixing or removing from site and supply and laying 50 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors as spout all as specified and directed.
S&F in repairs vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32 mm bore and of suitable length including fixing of pillar tap/WHB mixer complete all as specified. Note : Pillar tap and WHB mixer shall be measured and paid for separately as "Supply only".
Demolition of cement concrete (unreinforced) in floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including CI 'P' or 'S' trap, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish with and including PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe, 32 mm dia.
S&F in repairs, vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, and fixed with and including PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe, 32 mm dia complete all as specified
S&F in repairs 15 mm bore angle valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions as per cat part No. 8310 of Make-Prayag or equivalent of any make specified.
Supply only chromium plated, fancy type, centre hole WHB mixer as per cat part No. 8750 of Make-Prayag or equivalent of any make specified.
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges as per cat part No. BA-01 of Make-Prayag or equivalent of any make specified.
S&F in repairs brass chromium plated soap dish, fixed to plugs with chromium plated brass screws as per cat part No. BA-05 of Make-Prayag or equivalent of any make specified.
S&F in repairs brass chromium plated toilet paper holder with flap fixed with chromium plated screw and PVC cleat fixed etc. complete all as specified and directed as per cat part No. BA-88 of Make-Prayag or equivalent of any make specified.
S&F in repair health faucet (with 1.50 mtr tube) fixed to Angular Stop Cock and complete wall hanging arrangement complete all as specified and directed as per cat part No. BEA-86 of Make-Prayag or equivalent of any make specified.
S&F in repairs corner glass shelf 300 mm wide as per cat part No. BEA-44 of Make-Prayag or equivalent of any make specified.
S&F in repairs stainless steel plate rack, 0.63 mm thick of standard pattern, of size 31"x36"x10" complete all as specified and directed as per cat part No. P-348 of Make-Prayag or equivalent of any make specified.
S&F in repairs 15 mm bore bib taps (long body), cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm.
Supply only 15 mm bore pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
S&F in repairs brass chromium plated shower rose of 125 mm size with swivel joint including fixing to steel pipe or union.
S&F in repairs, 15 mm bore stop valve, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.
S&F in repairs grating doom 125 mm dia with waste hole of PTMT (minimum weight 40 gms).
S&F in repairs sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long.
S&F in repairs sink with drainage board made of stainless steel 1.00mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets embedded in wall with suitable size of PCC 1:3:6 type C-1 blocks and connecting union to pipe overall size 915 mm x 460 mm, bowl size 410mm x 330 mm x 160 mm and PVC waste pipe of 32 mm bore and of suitable length, complete all as specified.
S&F in repairs sink made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm and PVC waste pipe of 32mm bore and of suitable length, complete all as specified. (This item is for Servant Qtrs)
Dismantling of cast iron or reinforced concrete drain pipes of 75 mm to 100 mm internal dia, jointed in cement mortar and taking out of trenches, if required.
S&F 100 mm bore cast iron, sand cast, soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors or fixed to walls.
Fixing only 100 mm bore cast iron, sand cast, soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors or fixed to walls. NOTE :- cast iron pipes obtained from item No. 77.00 above shall be used under this item.
S&F 75 mm bore cast iron, sand cast, soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors or fixed to walls.
S&F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured).
S&F cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 100 mm bore pipe.
S&F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured).
S&F 75 mm bore CI cowl.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and removing from site. Note - Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each and removing from site. Note - Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
Taking down shutters of any description exc. 1 sqm and n. exc. 2 sqm each and removing from site.
Taking down shutters of any description exc. 1 sqm and n. exc. 2 sqm each and refixing in same opening after joining or cutting and repair.
S&F pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified.
S&F pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified.
S&F rolled mild steel of grade Fe-290 (Grade E-165) in rolled section as in frames for doors/windows, framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc.
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type both sides (ISI marked) with 6 mm thick teak wood edging all round.
S&F 35 mm thick factory made, second class hard wood, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated.
S&F 35 mm thick factory made second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided in to squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a), supplied and fitted to chowkats.
S&F stainless steel wire cloth, 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden beads supplied with shutters.
S&F 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed.
S&F 150 mm long aluminium handles, cast type, anodised.
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F 300 mm, mild steel, ordinary rat tail rod pattern springs including roller and roller plate complete.
M&L for preparation of new or previously untreated wooden surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer.
M&L for preparation of old painted wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, and fixing in the frame at site as per specification & drawing.
S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, fixing in opening as per specification and drawing.
S&F stainless steel butt hinges, medium weight, of size 100 mm.
S&F 125 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed.
S&F powder coated anodised Aluminium alloy sections sliding windows with frames Series-C (20mm) and , 3 track sliding shutters duly fitted with neoprene beading, glazing clips, two shutters tinted glass panes 4.80 mm nominal thickness one shutter with stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed. Note : Thickness of all aluminum sections used in frames /shutters etc shall not be less than 1.5 mm thick. Rates include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle with or without opeing for AC as directed by Engineer-in-Charge.
S&F aluminium anodised ventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members and half portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 4mm thick pin head glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm incl necessary channel frame work, including rubber gasket and aluminium beading complete and all as specified.
S&F mild steel of grade Fe-290 (Grade E-165) in framed work such as grills, grating etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders; ramed balusters; walk ways; railings; framework of water tanks and similar works.
S&F in repairs 20 mm dia stainless steel drapery rod, fancy type, fixed to walls with brackets and knobs complete all as directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint.
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F 100 mm long aluminium handles, cast type, anodized.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate in plinth protection. Concrete shall be laid in alternate bays n.exc 3 m in length finished fair and even including provision of joints of 6 mm wide and 10 mm deep along the wall and bays filled with bitumen mastic (1:3).
Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for and removing from site all as specified and directed. Note:- No credit of the reinforcement shall be recovered separately. Contractor shall quote his rate of this item taking into account of credit of reinforcement.
S&F rolled mild steel of grade Fe-290 (Grade E-165) in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
S&F powder coated anodised Aluminium aloy sections windows with frames Series-C (20mm), side Hung shutters duly fitted with neoprene beading, glazing clips, shutters with tinted glass panes 4.80 mm nominal thickness or with stainless steel wire cloth 0.36mm dia and average width of aperture 1.4mm , aluminium alloy handles etc. complete all as specified and directed. Note : Thickness of all aluminum sections used in frames /shutters etc shall not be less than 1.5 mm thick. Rates include all glazing/aluminium wire cloth, rubber packing, joining, cleats, glazing clips, aluminium snap beading, locking arrangements, handle as directed by Engineer-in-Charge.
S&F in repairs 15 mm bore brass CP mixer for mixing hot and cold water screwed down for iron pipe as per cat part No. 8775 of Make - Prayag or equivalent of any make specified.
M&L for cutting out cracks to V-section 5 to 7 mm wide in existing roof or terracing, cleaning out and filling with Dr. Fixit X power or equivalent polymer modified cracks filler all as per manufacturer's instructions complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe.
S&F in repairs 18 mm (+ 0.7 mm) thick, solid PVC sheet one side prelam sheet for cupboard shutter of density 600 Kg/Cbm bent 900 and finish at all edges at level for making egdes at level for making edge lipping/bending or 0.5 mm thick PVC sheet lipping at 4 edges using bonding tape etc complete all as per direction of Engineer-in-Charge and manufacturer specification.
S&F cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 75 mm bore pipe.
S&F in repairs cast iron floor trap, 75 mm dia of outlet, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4).
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint, white or tinted, over a coat of alkali-resistant priming paint all as directed.
M&L for complete removal of existing treatment from walls and applying two coats of cement base paint, white or tinted, over a coat of alkali-resistant priming paint all as directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of Acrylic Emulsion Exterior (Apex Ultima) weather proof paint, white or tinted, over and including a coat of primer all as directed.
M&L for complete removal of existing treatment from walls and applying two coats of Acrylic Emulsion Exterior (Apex Ultima) weather proof paint, white or tinted, over and including a coat of primer all as directed.
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces.
M&L for modular point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, fan regulators complete for the following :- (a) One light/fan point controlled by one, one way switch.
All as per item No. 131 above but for one light point controlled by two, 2 way switches.
All as per item No. 131 above but one 3 pin 5 or 6 Amps socket outlet on same board with other switches as directed.
All as per item No. 131 above but one 3 pin 5 or 6 Amps socket outlet on independent board as directed.
All as per item No. 131 above but one bell buzzer point controlled by one, bell push switch 5A.
M&L for modular point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 2.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including modular sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of modular switches, sockets, complete for one 3 pin 15 or 16 Amps socket outlet on independent board.
M&L for point wiring complete with 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size with 3 mm thick bakelite sheet white/coloured top cover for:- (a) One light/fan/bell point controlled by one, one way switch.
All as per item No. 137 above but for one light point controlled by two, 2 way switches.
All as per item No. 137 above but one 3 pin 5 or 6 Amps socket outlet on same board with other switches as directed.
All as per item No. 137 above but one 3 pin 5 or 6 Amps socket outlet on independent board as directed.
All as per item No. 137 above but one bell buzzer point controlled by one, bell push switch 5A.
M&L for point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit with wall thickness not less than 1. 8mm heavy duty including conduit accessories concealed in wall, ceiling etc including sunken type pressed steel terminal boxes of size 175/100mm with 3mm thick bakelite sheet cover white/coloured including 2.5 Sqmm, single core, PVC insulated but unsheathed copper conductor FRLSH 1100 volts grade cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board.
S&F modular switch 1 way 6 Amp, 1 module complete all as specified and directed.
S&F modular switch 1 way 16 Amp, 1 module complete all as specified and directed.
S&F modular socket 6 Amp, 2/3 pin combined 2 module complete all as specified and directed.
S&F modular socket 6 Amp/16 Amp, 6 pin combined 2 module complete all as specified and directed.
S&F modular switch 2 way 6 Amp, 1 module complete all as specified and directed.
S&F modular bell push 6 Amp, 1 module complete all as specified and directed.
S&F bell electric multi music type type 230 volts single pole all as specified and directed by Engineer-in-Charge.
S&F modular fan step regulator, 120W, 2 module, hum free and connecting electrically all as specified and directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 3 terminals 230 Volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amp ‘C’ curve type, 230 volts, 10 KA.
M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
M&L for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
M&L for sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and two run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH (RYBN) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 32 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete as directed by Engineer-in-Charge. NOTE: Four runs of cable with two run of earth wire and one run of PVC conduit shall be measured & paid for as one length.
S&F LED batten (4 Ft) indoor decortive aluminium extruded T5 LED battens duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 100+ lumens per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete.
S & F LED fixtures(2 Ft) 8 watt including all connection complete.
S&F LED wall light (525x25x36mm) made of synthetics housing with a PC glossy difusser duly prewired connection having a nominal system lumen output of 1600 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 09 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete.
S&F LED bulkhead fitting 9 watt IP 66 & IK 09 with pressure diecast aluminum housing & polycarbonate diffuser duly prewired for connection with flexible multi stranded copper conductor cable as required all as per directed.
S&F and testing factory made sheet metal enclosure for MCB DB SPN 8 way 240 volt with double door, IP - 43 protection with having 200 Amps bus bar duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
S&F and testing factory made sheet metal enclosure for MCB DB TPN 4 way 415 volt with double door, IP - 43 protection with having 200 Amps bus bar duly with fixed in wall/ concealed in wall complete and making good disturbed surfaces of wall, floor etc including electric wire connection all as directed by Engineer-in-Charge.
S&F tripple pole and neutral, powder coated, CRCA steel sheet VTPN DB constructed as per IS 8623 suitable for MCCB incomer upto 160 amp, 4 way, 415 volts, degree of protection IP 43 - IK- 09 with metal double door, recess mounted, having 200 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required.
S&F MCB single pole 230 volts any rating from 6 to 16 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F MCB single pole and neutral 240 volts any rating from 25 to 32 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F MCB triple pole and neutral 415 volts 63 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
S&F MCB triple pole 415 volts 63 amps, with rupturing capacity 10 KA, 'C' curve type, including providing thimble for out going cables.
Taking down ceiling fan of any make, type and sweep by disconnecting electric connection and depositing in MES store yard, oiling, greasing, painting in white colour with synthetic enamel paint and providing flexible wire of suitable length, replacement of unserviceable other parts like screw, clamps, nut, bolt, washer with split pin, rubber reel, capacitor/condenser, ball bearing, reassembling, testing complete all as specified and directed by Engineer-in Charge. and refixing/hanging the same after repair. Note:- Rewinding of fans shall be measured and paid for separetely. Replacement of unserviceable other parts like screw, clamps, nut, bolt, washer with split pin, rubber reel, capacitor/condenser, ball bearing shall be measured & paid for separately as “supply only”.
M&L for striping, cutting the existing copper winding of ceiling fans of the 1200 mm/1400 mm sweep of any make, rewinding with new heavy duty super enamelled copper wire of appropriate gauge (Make-Devi Dayal/SWAN/CHETAK/MUKATI/USHA) with insulation material, varnishing etc complete all as specified and directed.
Supply only ball bearing of 1200 mm (48")/1400 mm (56") sweep make: NBC/SKF/National suitable for ceiling fan.
Supply only oil type condenser of Usha/Bajaj/Unistar Make, 230 volts AC including necessary soldering of capacity 2.5 MFD.
Supply only screw, clamps with nuts & bolts with split pin, rubber reel for ceiling fan all as directed by Engineer-in-Charge.
S&F air ventilation fan 250 mm in toilet in rectangular in shape, PVC body, white colour 230V including louver shutter including cutting on wall for fixing of fan and making good disturbed surface complete all as specified and directed.
S&F TV co-axial modular socket 1 module
S&F telephone socket double RJ-11, 1 module
M&L for co-axial TV cable drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia in concealed, including modular terminal box with top cover, ISI marked ivory colour with all conduit fittings / fixing accessories as required.
M&L for PVC insulated unarmoured telephone cable for indoor applications 0.5 mm ATC 1 pair confirming to TEC specification G/WIR06/02 drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia, including modular terminal box with top cover, ISI marked ivory colour with all conduit fittings / fixing accessories as required.
Taking down carefully Geyser any type any capacity from existing accn and keep in safe custody for repair/refixing.
M&L for servicing of geyser of any type any capacity including cleaning thoroughly and overhauling, applying two coats of white synthetic enamel paint and refixing the same at exising location including connecting hot and cold water pipe complete all as directed by Engineer-in- Charge. Note:- Replacement of unserviceable parts shall be measured & paid for separately as “supply only"
Supply only heating element of Geysers of the 1/1.5 KW rating required at site including rubber washers. Make – Theeta/Recold/Bajaj (ISI Marked)
Supply only thermostat for the Geysers of 25 litres capacity duly ISI Marked.
Supply only PVC connection for the Geysers of any capacity.
Taking down exhaust fan of any make, type and sweep by disconnecting electric connection and keep in safe custody for repair/refixing.
M&L for servicing of exhaust fan of any sweep any type any make including cleaning thoroughly, servicing of fan motor & parts fitted therein, greasing/oiling of bush and bearings, applying two coats of white synthetic enamel paint over one coat of primer on fan blades and body, reassembling, testing and hanging to the existing site after servicing complete all as specified and directed by Engineer-in-Charge.
Taking down DB with MCB any type/any size & single pole and neutral enclosure with two pin and earth plug with MCB including all connecting accessories.
Taking down sub main wiring/service connection any type/any size including pipe and all connecting accessories.
Taking down carefully energy meter any type, any capacity upto 40 amp capacity after disconnecting and depositing in the MES store yard.
S&F MCCB four pole, 125 amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs etc complete.
S&F water heater 25 litre capacity BEE star rating 5, vertical pattern in approved colour, heating element 1.5 KW, adjustable temperature setting knob for temperature settings between 25°C to 75°C, outer tank made of non metallic engineering plastic, inner tank made of extra thick superior cold rolled steel provided with high density PUF insulation including CP connection of suitable length and CP fittings to connect with existing water supply system complete.
S&F exhaust fan in kitchen of 300 mm sweep, with bird protector heavy duty motor, double ball bearings, 510 CMH,single phase, 1350 rpm, powder coated metalic finish blade 3 Nos, noise level 40-45 dB, 230V, 40 Watt, 50Hz, with louver shutter and mounting acessories complete & connecting with & including 3 core PVC insulated copper conductor flexible cable of size 23/0.0076 (or eq. Size in mm) from ceiling rose to fan. including making openings for exhaust air through brick wall and making good by plastering rendering etc around the wall openings complete all as directed.
S&F switch piano flush button single pole one way 6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush button single pole two way 6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F socket out let, 5 pin 6 amps multi purpose 2 in 1 flush type, 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F switch piano flush button single pole one way 16 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F socket out let, 6 pin 6 & 16 amps multi purpose 2 in 1 flush type, shuttered type, 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F bell push, flush button single pole 6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge.
S&F fan regulator electronic, switch type hum free with polycarbonate body suitable to control speed of fan from 0 to 100% and connecting electrically all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Taking up or down steel tubing 25 mm bore and connections including cleaning for refixing or removing from site.
Supply and laying 25 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Refixing old steel tubing, 25 mm bore, and connections in new or old position (Walls, ceiling, floors, etc.) NOTE :- Steel tubes obtained from item No. 189.00 above shall be used under this item.
Excavating in trenches in soft/loose soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point.
Supply and lay in trenches/on wall/on pole/in duct /through protection pipe, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables heavy duty LT cable, 1100 volts grade with aluminium conductor cross sectional area 25 Sqmm 4 core size including retrieving/taking out/taking down old unserviceable cable from duct/trenches/pipes/pole/wall etc. including brick cover and protection pipe and disconnecting the connections. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 40 mm bore.
S&F smart three phase four wire dual source prepaid energy meters BIS 15884 marked in existing meter board/floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 415 volts accuracy class 1.0 alongwith parellel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual sorce registration with grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tarrif slabs, happy hours and holiday definition.
S&F smart single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board/floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 volts accuracy class 1.0 alongwith parellel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual sorce registration with grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tarrif slabs, happy hours and holiday definition.
Note:- Cutting chases in walls/floors/ceilings wherever required for electric work shall be deemed to be included in respective item of Schedule ‘A’.
VIJAY CONSTRUCTION CO
M/s Matadeen Ramchandra Agarwal
LUMOS INFRA PVT LTD
Jeet Construction
M/s Ram Singh Agarwal
AMIT ASSOCIATES
Pioneer Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .