Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹118.8 CrAccepted-AOC 112 RADHEY SHYAM VIHAR PHASE II MURAD NAGAR GHAZIABAD UP | GHAZIABAD | UP | ₹118.8 Cr Quoted ₹124.5 Cr | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹126.9 CrRejected-AOC | ₹126.9 Cr | L-2 | Rejected-AOC L-2 |
| 3 | L-3₹133.0 CrRejected-AOC | ₹133.0 Cr | L-3 | Rejected-AOC L-3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical BIDDER DOES NOT QUALIFY AS PER PQR |
Tender Value
₹94.5 Cr
EMD Value
₹1.9 Cr
Closing Date
19 Jan 2024, 5:00 pmClosed
SE CCP1
VCV GABBAR SINGH URJA BHAWAN KANWALI ROAD DEHRADUN
LOSS REDUCTION WORK UNDER REVAMPED DISTRIBUTION SECTOR SCHEME IN UTTARAKHAND STATE PKG G HARIDWAR
2023_UPCLC_65676_5
CCP-I/41/2023-2024
Open Tender
Electrical Works
730 days
AS PER TENDER DOCUMENTS
AS PER TENDER
6 documents required · 6 mandatory
₹29,500
EE HEAD QUARTER URJA BHAWAN
₹1.9 Cr
29 Apr 2025
11 Jan 2024
20 Jan 2024
11 Jan 2024
19 Jan 2024
12 Jan 2024
Amount
Replacement of Old Aged VCBs
33KV Incomer (SCADA Compatible)
33 KV SF6, 1250A, 24 V DC for I/c (SCADA Compatible)
33kV Relay and Control Panel for Single Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Single T/F.(SCADA Compatible)
33kV Relay and Control Panel for Double Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Double T/F.(SCADA Compatible)
Dismantling of existing 33 KV CB & Control Panel.
33KV Outgoing (SCADA Compatible)
33 KV SF6, 1250A, 24 V DC for O/g (SCADA Compatible)
33kV Relay and Control Panel for Single Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Single T/F.(SCADA Compatible)
33kV Relay and Control Panel for Double Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Double T/F.(SCADA Compatible)
Dismantling of existing 33 KV CB & Control Panel.
Replacement of 33 KV Old /Frayed Conductor
Reconductoring of 33 KV line with Covered Dog Conductor
33 KV AL-59 ACS XLPE (160sq mm) Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
33 kV Polymeric Pin Insulator complete
33KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC
IPC (160 sqmm MVCC to 160 sqmm MVCC)
IPC (Bare conductor to 160 sqmm MVCC) for 33 KV CC.
33 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(33 kv)
33 KV Mid span Jointing Kit Suitable for 240 Sqmm Covered Conductor.
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Single pole SP 55 as per annexure -J-21
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
33 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
11 kV Line : Reconductoring/Augmentation 11 KV line on Existing Pole
Reconductoring of 11 KV line with Covered Rabbit Conductor
11 KV AL-59 ACS XLPE (70sq mm)Rabbit Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC.
IPC (70 sqmm MVCC to 70 sqmm MVCC) for 11 KV CC.
IPC (Bare Conductor to 70 sqmm MVCC) for 11 KV CC.
11 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(11KV)
11 KV Mid span Jointing Kit Suitable for 70 Sqmm Covered Conductor.
Single pole SP 55 as per annexure -J-21 A
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure F-15)
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old Aged VCBs/OCB
Replacement of 11KV Incomer complete with CTs of ratio 800/400/5A (SCADA Compatible)
11 kV VCB 500 MVA, 800/400/5A I/C (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Replacement of 11KV Outgoing complete with CTs of ratio 400/200/5A (SCADA Compatible)
11 kV VCB FDR 500 MVA, 400/200/5A(Indoor Type) O/g (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Replacement of 11KV Bus coupler with 11kV motorised Bus coupler (SCADA Compatible)
11 kV VCB FDR 500 MVA, Bus Coupler (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Re-conductoring of bare LT line by LT ABC Replacement of LT Conductor with AB Cable in Theft Prone Areas
Replacement of LT Bare Conductor to AB Cable 3x120+1x95 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (120 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x120+1x95 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 95 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x95+1x70 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (95 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 70 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old /Frayed LT AB Cable
Reconductoring of LT AB Cable 3x120+1x95 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (120 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x120+1x95 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 95 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Sign Board
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) as per SBD.
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)
Description of Work / Item(s)
Amount
Replacement of Old Aged VCBs
33KV Incomer (SCADA Compatible)
33 KV SF6, 1250A, 24 V DC for I/c (SCADA Compatible)
33kV Relay and Control Panel for Single Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Single T/F.(SCADA Compatible)
33kV Relay and Control Panel for Double Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Double T/F.(SCADA Compatible)
Dismantling of existing 33 KV CB & Control Panel.
33KV Outgoing (SCADA Compatible)
33 KV SF6, 1250A, 24 V DC for O/g (SCADA Compatible)
33kV Relay and Control Panel for Single Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Single T/F.(SCADA Compatible)
33kV Relay and Control Panel for Double Ckt.(SCADA Compatible)
33kV Relay and Control Panel for Double T/F.(SCADA Compatible)
Dismantling of existing 33 KV CB & Control Panel.
Replacement of 33 KV Old /Frayed Conductor
Reconductoring of 33 KV line with Covered Dog Conductor
33 KV AL-59 ACS XLPE (160sq mm) Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
33 kV Polymeric Pin Insulator complete
33KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC
IPC (160 sqmm MVCC to 160 sqmm MVCC)
IPC (Bare conductor to 160 sqmm MVCC) for 33 KV CC.
33 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(33 kv)
33 KV Mid span Jointing Kit Suitable for 240 Sqmm Covered Conductor.
Single pole SP 72 as per annexure -C-36
Steel Tubular Poles 13 m long (STP 13.0 M, 410 MPa , SP-72) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Single pole SP 55 as per annexure -J-21
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
33 kV, V Type cross arm made of MS Channel 100X50X6mm complete with clamps, Nuts, Bolts & washers all galvanized
33 kV F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
33 kV Polymeric Pin Insulator complete
33 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
33 kV Danger board with GI clamp Bolts & Nuts.
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure C-18)
33 kV Galvanized Stay Set Complete 20ϕX1800 mm. with 2 no. turn-buckles, anchor plate (300x300x8mm) as per scope of work in SBD All galvanized
Stay Wire 7/8 SWG
33kv Stay Insulator
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
11 kV Line : Reconductoring/Augmentation 11 KV line on Existing Pole
Reconductoring of 11 KV line with Covered Rabbit Conductor
11 KV AL-59 ACS XLPE (70sq mm)Rabbit Covered Conductor (SS4240813 & SS4240814) EN50397-1:2006 by Electron Beam radiation Process.Including Sag Percentage
11 kV Polymer Pin Insulator with Pin complete.
11 kV Compsite Polymer Disc Insulator B & S type
11 KV Class Ball and Socket Polymeric tension insulator with Hardware with tracking IPC.
IPC (70 sqmm MVCC to 70 sqmm MVCC) for 11 KV CC.
IPC (Bare Conductor to 70 sqmm MVCC) for 11 KV CC.
11 KV Insulated Cable Ties.
Supply IPC with Aluminium Bail for Earthing 3 No / Km(11KV)
11 KV Mid span Jointing Kit Suitable for 70 Sqmm Covered Conductor.
Single pole SP 55 as per annexure -J-21 A
Steel Tubular Poles 11 m long (STP 11.0 M, 410 MPa , SP-55) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
V Type cross arm made of MS Channel 100X50X6mm complete with Clamps, Clamps, Nuts, Bolts & warshers all galvanized
F-Bracket made of MS Channel (100X50X6) mm with Clamps, Nuts, Bolts & Washers all galvanized
11 kV Polymer Pin Insulator with Pin complete.
11 KV Insulated Cable Ties.
Earth-wire clamp made of MS Flat 50x8mm with Nut & Bolts Warshers all galvanized.
11 kV Danger Board with GI clamp Bolts & Nuts
Anti-Climbing Device (2.5mm dia (12SWG) galvanized barbed wire 3.5 kg per pole) with 2 No. clamp made of 50x8 mm strip with Nuts, Bolts & Warshers all galvanized.
Aluminum paint (Double Coat)
Red Oxide paints
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Stay complete (As per annexure F-15)
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
11 kV Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Dismantling of old conductor and accessories with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old Aged VCBs/OCB
Replacement of 11KV Incomer complete with CTs of ratio 800/400/5A (SCADA Compatible)
11 kV VCB 500 MVA, 800/400/5A I/C (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Replacement of 11KV Outgoing complete with CTs of ratio 400/200/5A (SCADA Compatible)
11 kV VCB FDR 500 MVA, 400/200/5A(Indoor Type) O/g (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Replacement of 11KV Bus coupler with 11kV motorised Bus coupler (SCADA Compatible)
11 kV VCB FDR 500 MVA, Bus Coupler (SCADA Compatible)
Dismantling of existing 11 KV VCB/OCB.
Re-conductoring of bare LT line by LT ABC Replacement of LT Conductor with AB Cable in Theft Prone Areas
Replacement of LT Bare Conductor to AB Cable 3x120+1x95 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (120 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x120+1x95 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 95 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of LT Bare Conductor to AB Cable 3x95+1x70 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (95 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x95+1x70 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 70 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Replacement of Old /Frayed LT AB Cable
Reconductoring of LT AB Cable 3x120+1x95 Sqmm
Additional STP 8.5 M Pole SP 21 (As per Annexure K 10)
Steel Tubular Poles 8.5 m long (STP 8.5 M, 410 MPa , SP-21) as per IS 2713 (Parts 1 to 3): 1980 (Bottom Portion hot dip galvanized) with MS Plate (300ɸx6)
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
Concreting of Pole (CC ratio 1:3:6) and muffing (Kicking Block) (CC ratio 1:2:4) as per scope of work in SBD
Rod type earthing of pole by GI earthing rod 20ɸx2500mm with welded Clamp 40X3mm & GI wire 8 SWG (0.5 Kg) with Bolts Clamp, Washers & Nuts complete as per Drw. REC/RDSS/GEN/07 all Galvanized
Dead end clamp assembly suitable for AB Cable with all fittings and S.S.strap
Suspension clamp assembly suitable for AB Cable with all fittings and S.S.strap
L.T. Insulation Piercing Connectors for energizing distribution kiosk/box & Jumpering
Mid span jointing sleeves (120 Sq.mm.)
Supply & Fixing of LT distribution boxes/kiosk on the LT poles including all GI clamps & material required for mounting, connections & sealing.
Insulated ABC of 3x120+1x95 Sq.mm.
1x35 mm2 XLPE/PVC insulated Al. cable for energising the distribution boxes/ kiosks.
PG Connector/Wedge type/Wedge type 95 Sqmm.
LT Stay complete Annexure I-13
Galvanized Stay Set Complete 16ϕX1800 mm. with 2 no. turn-buckle, anchor plate (200x200x6mm) as per scope of work in SBD All galvanized
GI Stay Wire 7/10 SWG
LT Stay Insulator as per SBD
Stay Clamp (50x8mm)with Nut, & Bolts all galvanized
Grouting with Cement Concreating ratio with 1:3:6
Disconnecting of LT service line of consumers before dismantling of old LT line and the reconnections through distribution boxes/kiosk, supply & fixing of Clamp/Connectors etc for Consumer Service Cables after commissioning of ABC line.
Dismantling of existing conductor, shackle insulators, Clamps and accessories etc. from the existing poles with opening of existing jumpering and making of bundle including Loading/Unloading Complete Work.
Sign Board
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) as per SBD.
Sign Board 1 No.in each town 6x4 feet (lengh x breadth) made of MS sheet 14 Gauge(1.6mm thickness) with angle suport of (3"x3",6mm) and height of board 6 feet fromm ground level to bottom of board and length of angle to be buried in the ground 1.50 feet with 1 feet hole pass inside,painting on board ( enamel paint with red oxide base coat)and printing on board (colour printing by Screen printing method)
Raj Shyama Constructions Pvt. Ltd.
MLAPLNP Associates
Raj Shyama Constructions Pvt. Ltd.
RP INFRAPOWER PVT LTD
Raj Shyama Constructions Pvt. Ltd.
MLAPLNP Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid