| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹40.3 L+₹4.8 L (13.6%)Rejected-Finance SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹42.8 L+₹7.3 L (20.7%)Rejected-Finance FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | L4₹43.7 L+₹8.2 L (23.2%)Rejected-Finance 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L4 | Rejected-Finance Other Than Lowest Bidder | |
| 5 | L5₹43.9 L+₹8.4 L (23.6%)Rejected-Finance | L5 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹46.3 L
EMD Value
₹92,500
Closing Date
20 Sept 2023, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N Area Pin-160003
SPL REPAIR TO EXTERNAL ELECTRIFICATION TO CONVERT OVER HEAD LINE TO UNDER GROUND CABLES IN CERTAIN UNITS AND PARKING AREA AT N AREA AND MTF AT HALLOMAJRA UNDER GE CHANDIGARH
2023_MES_615528_1
GE/CHD-51/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandigarh
Class D category b(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹92,500
Yes
20 Oct 2023
24 Aug 2023
22 Sept 2023
24 Aug 2023
20 Sept 2023
8 Sept 2023
24 Aug 2023 - 31 Aug 2023
Amount
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 300 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 2 core complete all as specified and directed by Engr-in-Charge. Note for item 1 to 8: 1. Excavation & earth work, sand cushioning, and brick protection shall be measured and paid for separately.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm surrounded by mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less 2.25mtr below ground level with top edge of earth plate at a depth of not less than 1.50mtrs below ground level connected with and including 32x6mm galvanized iron strip as earthing lead by means of bolts, nuts, check nuts and washers made out of galvanized iron, 20mm dia medium grade GI pipes for watering with funnel, wire mesh and 40mm GI light grade protection pipe for GI strip and including necessary excavation, earth work, PCC 1:3:6 type C-2 concrete pit and RCC pit cover charcoal and common salt filling in alternate layers complete all as specified and directed by Engineer-in-Charge on electrical plate no-3 of SSR Par-I of 2009. Note:(i) If desirable earthing result not found re done earthing without any extra charge until get required earth resistance. (ii) The result sheet of earthing may submit to sub division level by contractor.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge. Note : (i)The unit rate includes for protecton pipe 15mm and GI earth strip 4mm from top of earth plate upto 7.50 metre above ground level. (ii) If desirable earthing result not found re done earthing without any extra charge until get required earth resistance. (iii) The result sheet of earthing may submit to sub division level by contractor.
M & L for cable route indicator made of cast iron plate circular type 10 cm dia duly marked Blue colour marked LT cabless arrows mark up side duly welded/nut, bolt with angle iron 45/45 equal size and 45 cm long duly grouted on fround with PCC (1:3:6) as in foundation & earth work excavation etc complete all as specified an directred at site.
Supply, install, testing & commissioning of distribution LT panel OUTDOOR of suitable size factory fabricated(Approved by CPRI) outdoor cubical/KIOSK type totally enclosed made out of 3.15 mm thick MS sheet and inner comparments of 2.00mm thick steel sheet enclosure with double door shutter with locking arrangement and angle iron legs made out of 50mmx50mmx 6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system with hinged panel door(covers) on two sides with handle,bottom gland plate and locking arrangement consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of copper bus bar with colour code of 475 Amps capacity each, with PCC foundation mounted on epoxy insulators with and constitute the following :- Incoming (a) MCCB 315 Amps , 4 pole, ultimate breaking capacity 35 KA 415 Volts – 01 Nos Outgoing (a) MCCB 125.00 Amps , 4 pole, breaking capacity 25 KA,415 Volts – 01 Nos (b) MCCB 100 Amps 4 Pole,25 KA, 415 V-02 Nos. (c) MCB 32 Amps 2 Pole,240 V-02 Nos.(For street Light) (d) Suitable size of Timer analog type for street light complete
S&F MS Box made out of 3.15mm thick sheet of size 90mmx90mmx60mm with aluminium bus bar 32Amp 1100V complete all as specified and directed by Engineer-in-Charge.
M&L for steel water tubing, galvanised, light grade, ISI marked, 80 mm bore fixed along poles, under roads/culverts complete all as specified and directed by Engineer-in-Charge.
M&L for steel water tubing, galvanised, light grade, ISI marked, 100 mm bore fixed along poles, under roads/culverts complete all as specified and directed by Engineer-in-Charge.
M&L for steel water tubing, galvanised, light grade, ISI marked, 40 mm bore fixed along poles, under roads/culverts complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth and not exceeding 10sqmm on plan and getting out complete all as specified.
Returning,filling in including spreding, levelling, watering and well ramming in layers not exceeding 25 cm thick each excavated soil in trenches after the pipes have been laid and tested completed as in soft/loose soil, complete all as specified.
Removing of surplus soil/excavated material to a distance not exceeding 50meter and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
Supply and laying burntbricks sub class "B" old size for cable protection laid flat lengthsise perpenducualr to the axis of cable complete all as specified and direted by Engineer-in-Charge.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and directed.
Dismantling insulators any type, any size complete all as specified and directed
Dismantling of ACSR or AAC conductors complete all as specified and directed
Dismantling earth wire or copper conductor, service feeder or distributor span complete all as specified and directed.
Dismantling stay assembly complete complete all as specified and directed.
Taking down street light fittings from existing poles and Refixing the same amd making suitable connections with junction box to street light through existing PVC twin core cable including suitable size of PVC conduits with clamps complete all as specified and as directed.
Supply and fix in repairs sheet metal enclosures for DB's double door TPN 415 volts 4 way class IP-43 epoxy coated inside and outside, detachable gland plates flush/mounted for MCBs fitted with bus bar complete all as specified and directed.
Supply and fix MCB 4 pole 40 Amp to 100Amp, 415 volts, 10 KA, B-curve complete all as specified and directed.
Supply and fix MCB SP 6 to 32 Amp, 240 volts,10 KA, C-curve complete all as specified and directed.
M/s Friends Engineering Works
Gupta Enterprises
LONGIA ENGINEERS
unique power & control system
SABHYATA ELECTRICAL AND MECHANICAL
M/s Shiksha Enterprises
Bharat Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .