Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.6 LAccepted-AOC III 246 MANIYATTU BUILDING KURUPPAMPADY P O RAYAMANGALAM ERNAKULAM KERALA 683545 INDIA | ERNAKULAM | KERALA | 683545 | L1 | Accepted-AOC L1 | |
| 2 | L2₹80.2 L+₹1.5 L (1.97%)Rejected-AOC CA 325 SA767 PWD K EL 13 1 472 CASAMARINA COMPLEX TALAP KANNUR | KANNUR | KANNUR | KERALA | 670101 | L2 | Rejected-AOC L2 | |
| 3 | L3₹81.3 L+₹2.7 L (3.46%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹86.6 L
EMD Value
₹50,000
Closing Date
14 Oct 2024, 6:55 pmClosed
Chief Electrical Engineer
O/O CHIEF ELECTRICAL ENGINEER,PWD ELECTRICAL WING,PUBLIC OFFICE,TRIVANDRUM
GENERAL Budget 2021 22 Chalode Town Beautification Works Providing Decorative Lighting at Chalode Junction General Electrical Work
2024_PWD_694060_1
PWD/BLDG/TR/3429/2024_6_1_1/1
Open Tender
Electrical Works
Item Rate
180 days
CHALODE
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
Yes
15 Nov 2024
3 Oct 2024
17 Oct 2024
3 Oct 2024
14 Oct 2024
3 Oct 2024
3 Oct 2024 - 14 Oct 2024
Amount
Chalode Town Beautification
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
OD248650/2023-2024:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring)
OD248651/2023-2024:Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
OD106761/2024-2025:Supply, installation ,testing and commissioning of 7 Meters height HDGI Decorative Pole with Decorative arm having 750MM overhang for mounting streetlight at 7MTR height from ground level, pole tube made of mild steel /steel tube, thickness minimum of not less than 3mm. Pole shall have two sections, bottom section shall be minimum height of 1MTR with dia of 140mm.The upper section shall be not less than 6MTR with minimum dia of 76 mm. The Pole is to be provided with a suitable surface mounting base plate and welded at the bottom of the pole. Pole shall be mounted on square base plate, suitable for mounting on 4 nos foundation bolts. The Base Plate dimensions shall be 200X200X12mm. and bolts with 20mm diameter (4 numbers) foundation bolts of 600mm bolt length, 200mm pitch circle diameter manufactured from special steel along with nuts, washers, anchor plate and common template including supply and providing junction looping box at bottom section with 32 A heavy duty 4 way connector for loop in & loop out and with MS base plate, provision for fixing SP MCB etc .. The pole shaft and base plate shall be hot dip galvanized (7 Stage process) before the coating of epoxy primer to minimum 65 microns. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. After galvanization complete pole shall be treated with 2 layer of high quality epoxy primer and thereafter coated with Polyurethane paint( Marine grade paint) to minimum average DFT of 100 microns (Total thickness minimum 160 micron- Test report shall submitted).The pole shall have internal junction box/control box. Designed to basic wind speedof 169kmph without any deformation or damage to the structure. Pole colour shall be black. Hot Dip Galvanised 750mm Over Hang Single Arm GI Decorative Bracket tightned to the pole top with stainless steel grub screws to mount the luminaire ( Kesslec or Techno commercial equivalent)
90.15.2.3:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters
OD102633/2024-2025:Supply installation testing commissioning of 3MTR height HDGI Decorative Pole with cast iron embellishmnets, pole tube made of mild steel /steel tube, thickness minimum of not less than 3mm. Pole shall have two sections, bottom section shall be minimum height of 1MTR with dia of 114mm.The upper section shall be not less than 2MTR with minimum dia of 76 mm. The luminaire shall have cast iron neck reducer jointing lowe and upper part and aesthectic appealing cast iron base with dia not less than 150mm. The Pole is to be provided with a suitable surface mounting base plate and welded at the bottom of the pole. Pole shall be mounted on square base plate, suitable for mounting on 4 nos foundation bolts. The Base Plate dimensions shall be 200X200X12mm. The pole shaft and base plate shall be hot dip galvanized (7 Stage process) before the coating of epoxy primer to minimum 65 microns. Poles using pre galvanized steel tubes or hot dip galvanized through double dip process are not acceptable. After galvanization complete pole shall be treated with 2 layer of high quality epoxy primer and thereafter coated with Polyurethane paint( Marine grade paint) to minimum average DFT of 100 microns (Total thickness minimum 160 micron- Test report shall submitted).The pole shall have internal junction box/control box. Designed to basic wind speed of 169kmph without any deformation or damage to the structure including connector foundation bolt 4 nos fixed in existing RCC foundation and junctions box etc.complete (Make: KESSLEC HDGI 3M RILA Pole or Techno commercial equivalent)
OD102943/2024-2025:SITC of 40W Post top Decorative classic LED street lantern, BIS certified with a luminaire body made of cast and spun aluminium, permanently sealed optical block with heat sink and polycarbonate protector fitted with a VentPlug pressure equalisation unit, fixed onto a hinged spun aluminium frame, control gear compartment accessed by loosening one screw for tool free opening and closing. The luminaire shall have ingress protection of IP66 and impact resistance of IK10. Highly efficient temperature resistant lenses for light distribution with several optical options providing excellent photometry to optimally cater to different applications. Suitable for post top mounting, Overall system efficiency of 120lm/W at correlated colour temperature (CCT) of 4000K. colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 kV. ( KESSLEC VALE 40W NW POST TOP LED or Techno commercial equivalent)
OD100259/2024-2025:SITC of 90W Suspended Decorative classic LED street lantern, BIS certified with a luminaire body made of spun aluminium, permanently sealed optical block (IP66) with heat sink and a PMMA protector IK07 fitted with a VentPlug pressure equalisation unit, fixed onto a hinged spun aluminium frame, control gear compartment accessed by opening clamps for tool free access. Highly efficient temperature resistant lenses for asymmetric light distribution with several optical options (T3) providing excellent photometry to optimally cater to different applications. Overall system efficiency of 140lm/W at correlated colour temperature (CCT) of 4000K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac, Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4/4 kV and an additional surge protection device (SPD) of 10/10 kV (make: KESSLEC MOON 90W NW SUS ASYM LED or Techno commercial equivalent)
OD106796/2024-2025:Supply Conveyance, installation, testing and commissioning of 24000 lumen LED, efficacy >=120 Lm/watt, IP 66 flood light fitting with die-cast aluminium housing, polycarbonate cover complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux duly wired up for use on 230V AC supply.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm
90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size
90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
OD102944/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 6 sq. mm
9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm)
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
OD248652/2023-2024:Supply, conveyance & installation of Hensel or equivalent make IP 66 / IP 67 weather proof 180x 130 x 77 mm cable junction Box ( KF 1006 B) with Terminal Set 2.5-6 sq.mm Copper
90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD248653/2023-2024:Supply and fixing Time switch 240V AC DIN/BASE mounting(L&T J648B1-Analog version) in the existing enclosure and giving connection as required
OD102741/2024-2025:Supply and fixing 40A 4 Pole power contactor (L&T) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required (L&T 4pole Contactor CS97012BOOO,40 AMNX 40/ Equivalent)
OD248656/2023-2024:Supply &fixing DIN Rail in the existing board
OD248657/2023-2024:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board as required.
OD248658/2023-2024:Supply and fixing 32A, HRC Fuse Base with HRC Fuse link with connections, in existing meter board as required.
OD102999/2024-2025:Supply and fixing 50 mm dia 6Kgff/cm2 PVC pipe including fixing the pipe with clamp/clips at 60cm spacing. etc as required (For Service Pipe)
90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD138477/2024-2025:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip
OD248660/2023-2024:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required. 25 mm X 5 mm G.I. strip
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
OD102946/2024-2025:Supply & laying of bare earthing conductors of following size in ordinary soil 0.75m below ground level including excavation 3.15 mm copper conductor (10 swg)
90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
90.16.2.1:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD248661/2023-2024:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 25x6mm brass nut and bolt etc. as required.
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
OD248662/2023-2024:Supply and fixing of Danger 415 V, 150 x 100 mm aluminium anodised legend plates as required.
OD140009/2024-2025:Supply, installation, testing and commissioning of 4800 lumen LED, efficacy >=120 Lm/watt, IP 66 flood light fitting with die-cast aluminium housing, polycarbonate cover complete with THD <10%, power factor >0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7, with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux duly wired up for use on 230V AC supply.
OD11666/2024-2025:Supply ,conveyance ,installation testing and commissioning of 1200 mm 1x20 W LED tube light fitting housing made of extruded thermal polycarbonate with 6500K , color temperature with duly wired up for use on 230V AC . The light fittings shall be fixed directly on wall or ceiling with and giving connection with required length of 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
OD56852/2024-2025:Hire and labour charges for concrete cutting as required.
Sajju T
PRADEEP KUMAR.V.K
Bidder Name
Sajju T
PRADEEP KUMAR.V.K
candelaengineering corporation
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1081223.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .