Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC CAMP AT GORUBANDHA MISSAMARI ASSAM 784506 | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹40.5 L+₹2.8 L (7.37%)Rejected-Finance MISSAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹41.0 L+₹3.4 L (8.89%)Rejected-Finance CAMP AT GORUBANDHA MISSAMARI ASSAM 784506 | SONITPUR | ASSAM | 784506 | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT VALIDATED (NOT ENLISTED IN CATEGORY b(i) ) |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
17 Sept 2024, 6:00 pmClosed
GE MISSAMARI
PO-Missamari Dist-Sonitpur Assam
SPECIAL REPAIR OF R AND O FLT HANGAR ADJACENT TO ANNEX BLDG (OFFICE COMPLEX) UNDER ARMY AVN CIV WKS ASSETS OF R AND O FLT/ ARMY AVN SQN (R AND O) UNDER GE MISSAMARI
2024_MES_661767_1
8504/E8
Open Tender
Civil Works
Item Rate
210 days
GE MISSAMARI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE MISSAMARI
₹97,000
Yes
14 Nov 2024
24 Jun 2024
19 Sept 2024
24 Jun 2024
17 Sept 2024
9 Jul 2024
25 Jun 2024 - 1 Jul 2024
Amount
M&L Surface Preparation by removing existing flooring with mechanical means, prepare the concrete substrate with proper scarifying & diamond grinding, Shot blasting, with Vaccum cleaning to remove dirt, dust, laitance, other contaminants etc., and to form the required anchor profile on the floor substrate between the floor topping and the concrete floor complete all as directed.
Providing and applying 2 part water dispersed epoxy resin primer Sikafloor ®-80 Epocem Primer followed by applying temporary moisturer barrier technology based three part, self smoothing underlay screed Sikafloor 81 Epocem to a thickness of 2mm having carbon dioxide diffusion coefficient 1782 as per Klopfer Engel fried method, Water vapour diffusion co-efficient µH2O = 177 as per DIN 52615, Water absorption co-efficient W = 0.06 kg/m2as per SN EN 1062-3, Compressive strength 55 N/ Sqmm after 28days as per ASTM C 579, Flexural strength 10 N/ Sqmm after 28days as per EN 196, When applied at minimum 3 mm thickness it can be laid over high moisture content substrate when substrate moisture is more than 4% complete all as per manufacturers instruction and as directed.
Installation of Epoxy topping 2mm using notch trowels and Spike rollers. Providing and applying 2mm thick two part, solvent free, coloured,100% solids, self smoothing, smooth glossy, epoxy resin topping Sikafloor®-264 HC using notch trowels and spike rollers having compressive strength of 53 N/mm2 as per EN 196-1, Flexural strength of 20N/mm2 as per 196-1, Shore D Hardness 76 As per DIN 53 505, abrasion resistance 41mg ( CS10/ 1000/ 1000) as per DIN 53109 complete all as per manufacturers instruction and as directed.
Crack Treatment: Inspecting the surface for any cracks. Cracks if any have to be sealed with epoxy repair mortar after clean or removal of cover concrete and making 'V' groove of 20mm wide and 10mm deep cover crack line along the length of the crack by elctrically operated angle grinder with diamond concrete saw blade and cleaning it by air blower complete all as per manufacturers instruction and as directed.
Sealing of exposed 'V' groove of 20mm wide and 10mm deep with Sikadur 31 or equivalent solvent-free, moisture tolerant, thixotropic, structural adhesive and repair mortar, based on epoxy resins and special fillers, designed for use at temperatures between +10°C and +40 °C. Product should conforms to ASTM C 881-78, Type I, Grade 3, Class B+C : compressive strength > 60 N/mm2 (14 days) according to ASTM C881 : bond strength < 10 N/mm2 (7 days) according to ASTM C882 .
Supply and fix for Turbo Ventilators Industrial/domestic turbo ventilator as per Manufactureres Insturction :- (i) (Turbine Dia 28 Inch (760mm), (Nech/Throat-24"), (Height-18"/610mm) (Vanes(Blades) - 42 Vanes, Aluminium 0.50mm Alloy 8011), Base Ring MOC(Mounting ring - Stainless steel),(Top plate MOC- Stainless steel 0.80 mm thickness). (ii) Rotation - Twin sealed 6203ZZ bearing with self lubricating duponty zytel 101L Polyamide 66 resin to ensure frictionless rotation even at lowest wind velocity Twin sealed 6201ZZ bearings with self lubricating Duponty Zytel 101L Polyamide 66 resin to ensure frictionless rotation even at lowest wind velocity. (iii) (Centre shaft : 18mm high carbon steel zinc plated) ( Inner Arms - M.S. with electro zinc plating), (Outer Arms - M.S. with electro zinc plating), (Frp base plate - 2mm thick clear 1.020 mtr wide 1.65 mtr long matching your sheet profile weight 8Kg Approx), (Centre width - 800mm+/-5mm), (Dia of Bottom Ring- 600mm+/-15mm), (Nos of Bearings -02 Nos), (Bearing Type : skf-6001ZZ & 6003ZZ) (Rivets-Aluminium Alloy wiht Washer) ,angle adjustable range- 0 to 17 deg,Exhaust capacity- 1972 - 2164 CFM, Wind velocity 8 Km/Hr, complete all as per manufacturers instruction and as directed.
S&F nylon HDPE bird proofing net of 2 cm pitch as directed. Note : Rate quoted by the contractor shall deemed to inclusive of necessary scaffolding and all other fittings and binding materials as required for fixing the net complete all as directed.
M&L preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described applying one coat of synthetic enamel paint complete all as directed.
S&F pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws and including dismantling plain or corrugated steel sheeting any gauge, thickness complete all as specified and as specified.
M&L in repairs to sliding iron door of hangar, area exceeding 20 Sqm including greasing ,oiling rollers and including replacement of small accessories if required complete all as specified and directed.
Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down the existing unservicable UG cable of any type/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. Note:- Concealed conduit in RCC slab/beam shall not be not be taken out and same shall be reused for passing out cable
M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including steel conduit medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.
Description all as per item No 15 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 15 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
M&L surface point wiring for One one socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including steel conduit medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel not less than 1.22 mm thick for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed. Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles.
S&F Switch piano, flush type single pole, one way 5/6 Amp complete all as specified and as directed.
S&F Switch Socket outlet 2 in 1, 3 pin, 5/6 Amps flush type complete all as specified and as directed.
S&F Switch socket combination 2 in 1, 3 pin, 5/6 Amp flush type universal complete all as specified and as directed.
S&F Switch socket combination 2 in 1, 3 pin, 15/16 Amp flush type universal complete all as specified and as directed.
S&F ceiling rose, 3 phase PVC/ polycarbonate, insulated body, three terminals, complete all as specified and as directed
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Triple pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed
S&F MCB, TPN, C Series 415 Volts, 63 Amps 50 HZ, 10KA complete all as specified and as directed.
S&F MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed.
M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED
M&L Concealed sub-main wiring alongwith earth wire of size of 4 x 10 sq. mm + 1 x 10 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED
S&F in repairs Energy saving new Next generation, energy saving, environment friendly & robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy not less than 150 lm/W, 6500K Cool day light , with toughened glass highbay light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 150 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 2.5 Sqmm 3 core ceiling rose to fitting and iron bracket made out of Angle iron bend to required shape as directed to be fitted complete all as specified and as directed.
S&F in repair, Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 Flood light fitting luminaire, with system efficiency ≥110 lumen/W,AC120-300 V with high power LEDs as light source and Secondary lenses 10KV SPD included with high efficiciency electronic driver of capacity 120 watts, with pre wired and necessary mounting arrangement and provision of 4.00 sq mm three core flexable copper conductor cable multi stranded ,connected to existing points in Hangar beam angle of any description complete all as specified and as directed.
M&L in replacement for Joists of Motor, bracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats of suitable size etc including nuts, ,bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including two coats of synthetic aluminium paint over a coat of red oxide primer after preparation of steel surface complete all as directed.
S&F in replacement MCCB 4 Pole 200 Amps, thermal magnetic type with breaking capacity 36 KA with thermal magnetic release at 415 volts,including spreader terminal complete all as specified and directed.
S&F in repair, VTPN DB, 08 Way, double door,Metal door ,IP-43 IK 09, with and including 4 Pole MCCB as incomer, and MCB;s as Outgoing , 250 Amps rated copper bus bars,earth bar,neutral links, complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces including complete all as specified and as direct. Note:- MCB's required as Outgoing shall be measured and pair seperately under appropiate items
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. Note : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
M & L for Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth and getting out in soft / loose soil for laying /taking out of LT UG cable complete all as specified and directed.
M & L for Returning, filling in incl spreading, leveling , watering and well ramming in layers not exc 25 cm thick in soils complete all as specified and directed.
M & L for Removal of surplus soil to a distance not exc 50 mtr away and depositing where directed as a level not exc 1.5 mtr above the starting point complete all as specified and directed
Supply and laying well burnt Bricks , locally available best quality (sub class "B" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified.
Supply , spread and filling approved sand in cable trenches for cushioning of LT UG cable complete all as specified and directed. Note :- Punned thickness only will be measured and paid.
M&L 50mm bore GI pipe light grade with all necessary fittings (ISI marked) as in cable protection fixed to pole, laid in trenches/road/floor complete all as specified and as directed.
M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:2:4) type B1 precast RCC cover slab (1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia medium grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.
MAA CONSTRUCTION (BID ID -3079312)
M.P.SUPPLY (BID ID -3055315)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .