Loading…
Loading…
Tender Value
₹56.6 L
EMD Value
₹57,000
Closing Date
10 Jun 2026, 6:05 pm5d left
Executive Engineer, Mahisagar (R&B) Division, Lunawada
Construction of Mamlatdar Quarters (D-Type) (1-Unit) at Kadana Dist. Mahisagar
310268
02 of 2026-27 (Reinvite)
Open
Civil Works - Buildings
Mahisagar
2 documents required · 2 mandatory
₹2,400
Executive Engineer, Mahisagar (R&B) Division, Lunawada
₹57,000
1 Jun 2026
1 Jun 2026
1 Jun 2026
10 Jun 2026
1 Jun 2026
No. Figure Amount
1 Excavation for foundation upto 1.50 mt depth including sorting out and 258.40 Cum 278.06
stacking of useful materials and disposing the excavated stuff within all lead
and lift for soft rock not requiring blasting.
2 Excavation for foundation from 1.50 mt to 3.00 mt. depth including sorting out 61.00 Cum 301.85
and stacking of useful materials and disposing the excavated stuff within all
lead and lift (D)Soft rock not requiring blasting.
3 Filling in foundation and plinth with sand in layers of 20 cm thickness 24.10 Cum 479.80
including watering, ramming and consolidating etc. complete.
thickness including watering, ramming and consolidation etc. complete.
5 Anti Termite System : P/L of Permanent piping technology Anti Termite 120.20 Sq.m. 63.63
treatment before flooring work by installing LLDP (Low linear density
Polyethylene) tube of 8 mm O.D.& 6.4 mm I.D. with in Built Pressure
Compensation chip every 30 cm interval in the tube, having working pressure
of 2 kg/cm 2 and release rate of 1.9 ltr/Hour fixed by P-Clip and nails. The
LLDP pipe shall be installed at the entire periphery of the building and at
internal network of building depth of 20 to 200 mm under floor every 2 to
mtr. c/c distance (adjustable as per building layout) & ends of loop pass
through a PVC Elbow of minimum 32 mm ID at junction box of wall and floor
level, entering into a steel reinforced grooved flexible pipe mini. 22 mm LD
leading into junction box and during injecting chemicals for termite control
treatment.
The anti-termite chemical Lmidcloprid 30.5% SC mix as per IS 6313 (part-III)
shall be injected by the pressure pump diluted with water @ 10.5 ml/5ltr of
water at the rate of 2 kg/sq.cm. @ 5 ltr /Smt. the contractor shall submit
approved line plan for piping system and junction boxes dully approved by
Engineer-in-charge with bond of 5 years warranty. (II) Anti Termite chemical
injected area (Chemical injecting including labour cost)
6 Providing and laying controlled cement concrete M-150 and curing complete 36.20 Cum 4251.84
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Foundations and plinth for PCC.
7 Providing and laying controlled cement concrete M-250 and curing complete 33.20 Cum 4734.10
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Foundations, footings & mass concrete.
8 Providing and laying controlled cement concrete M-250 and curing complete 3.40 Cum 8012.17
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Columns upto plinth level.
9 Providing and laying cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 36.20 Cum 3092.22
machine cut stone aggregate 40 mm nominal size) and curing complete
including cost of form work in foundation and plinth.
10 Providing and laying controlled cement concrete M-200 and curing complete 9.30 Cum 7919.57
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Columns for Ground floor.
11 Providing and laying controlled cement concrete M-200 and curing complete 3.00 Cum 7961.11
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Columns for First floor.
12 Providing and laying controlled cement concrete M-250 and curing complete 13.30 Cum 6398.17
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Ground beam and plinth beam.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
13 Providing and laying controlled cement concrete M-150 and curing complete 18.10 Cum 4662.62
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Plinth Slab.
14 Providing and laying controlled cement concrete M-200 and curing complete 11.80 Cum 6364.82
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Beam for Ground floor.
15 Providing and laying controlled cement concrete M-200 and curing complete 1.10 Cum 6934.10
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Chhajja for Ground floor.
16 Providing and laying controlled cement concrete M-200 and curing complete 0.80 Cum 9021.71
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Lintel for Ground floor.
17 Providing and laying controlled cement concrete M-200 and curing complete 14.50 Cum 6776.77
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Ground floor slab.
18 Providing and laying controlled cement concrete M-200 and curing complete 4.10 Cum 5970.26
including the cost of form work but excluding cost of reinforcement for
reinforced concrete work in Coping on Ground floor.
19 Providing and fixing 90 cm high Stainless steel railing made from anti 2.70 Rmt. 3719.83
corrosive 304 grade S.S. pipe of 50 mm dia. (16 gauge) as hand rail with S.S.
304 grade baluster of 38 mm dia. (16 gauge) as a vertical support fixed in
RCC slab at 1.2m c/c including three horizontal S.S. pipes of 25 mm dia. (16
gauge) at equal distance fixed by 18.75 mm dia (16 gauge) S.S. pipe with
baluster including accessories as per detailed drawing as directed etc.
20 Providing I.S.I. Mark T.M.T. bar Fe-500D reinforcement with fusion bonded 13728.50 Kg. 77.29
epoxy coating not less than 175 micron thickness and upto 300 micron to
reinforcement bars as per IS-13620-1993/ASTM-775M (including testing of
coating at plant and all taxes) for R.C.C. work including bending, binding and
placing in position complete upto floor two level for Ground floor.
21 Providing I.S.I. Mark T.M.T. bar Fe-500D reinforcement with fusion bonded 982.00 Kg. 78.34
epoxy coating not less than 175 micron thickness and upto 300 micron to
reinforcement bars as per IS-13620-1993/ASTM-775M (including testing of
coating at plant and all taxes) for R.C.C. work including bending, binding and
placing in position complete upto floor two level for First floor level.
22 Steel work, welded in built up sections framed work including cutting, hoisting, 13.00 Qtl. 9108.27
fixing in position and applying a priming coat of red lead paint & two coat oil
paint. (A) In beams and joists, channels angles Tees, flats, with connecting
plates or angle cleats as in main and cross beams. Hip and jack rafters,
purlins connected to common rafters and the like.
23 Painting two coats (excluding priming coat) on new steel and other metal 37.00 Sq.m. 92.26
surface with enamel paint, brushing, interior to give an even shade including
cleaning the surface of all dirt, dust and other foreign matter.
24 Providing and fixing eco-friendly light weight calcium silicate false ceiling tiles 44.00 Sq.m. 1674.15
having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for
extra strength. The Light weight calcium silicate ceiling tiles shall have, light
reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity
resistance and also having thermal conductivity 0.043° w/m KC. for the best
thermal Insulation. The Light weight calcium Silicate tile shall be of approved
texture Fine fissured/ Spintone/ Cosmos having NRC value of 0.5 & Globe
having NRC value of 0.75 NRC or equivalent of size 595 x 595 mm to be laid
on true horizontal level suspended inter locking metal grid of hot dipped
galvanized steel sections (galvanizing @120 grams per sqm including both
side) consisting of main ‘T’ runner suitably spaced at joints to get required
length and size of 24 x 38mm made from 0.30 mm thick (minimum) sheet,
1200mm centre to centre and cross ‘T’ of size 24 x 28mm made out of
0.33mm (Minimum) sheet spaced 1200mm along spaced between main 'T' at
600mm centre to centre to form a grid of 1200 x 600mm and size 24 x 48mm
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
made of 0.30mm thick (Minimum) sheet to be interlocked at middle of the
1200 x 600mm panel to form grid of size 600 x 600mm resting on periphery
walls/partitions on a perimeter wall angle pre-coated steel of size (24 x 24 x
3000mm made of 0.40mm thick (minimum) sheet with the help of rawl plugs
at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval
and laying 15mm thick densified edges light weight calcium silicate ceiling
tiles of approved texture (Fine fissured / Cosmos / Spintone) in the grid
including cutting / making opening for services like diffusers, grills, light
fittings, fixtures, smoke detectors etc., whenever required, Main 'T' runners to
be suspended from ceiling using G.I. slotted cleats of size 25 x 35 x 1.6mm
fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I.
adjustable rods with galvanized steel level clips of size 85 x 30 x 0.8mm,
spaced at 1200mm center to centre long main 'T' bottom exposed with 24mm
of all T-sections and also provide additional frame work and
suspended G.I. support as required height shall be pre-painted with polyester
baked paint, for all heights, as per specifications, drawings and as directed by
engineer-in-charge. Note:- Only calcium silicate false ceiling area will be
measured from wall to wall. No deducation shall be made for exposed
frames/opening (cut outs) having area less than 0.30sqm. The calcium
silicate ceiling tiles shall fissured / Spintone / Cosmos and 0.75 NRC for
Globe, light reflection 85% non-combustible as per B.S. 476 part IV, 100%
humidity resistance and also having thermal conductivity. 0.043 w/m KC for
the best thermal Insulation.
25 Providing and laying brick work using common burnt clay building 15.30 Cum 4214.33
conventional type bricks having crushing strength not less than 35 Kg./Sq.cm.
in foundation and plinth in cement mortar 1:6 (1 cement : 6 fine sand)
including the cost of all materials and labour charges etc. complete.
26 Providing and laying brick work using common burnt clay building 102.70 Cum 4496.05
conventional type bricks having crushing strength not less than 35 Kg/sq.cm.
in super structure above plinth level upto floor two level in cement mortar 1:6
(1 cement : 6 fine sand) for Ground Floor including the cost of all materials
and labour charges etc. complete.
27 Providing and laying brick work using common burnt clay building 12.20 Cum 4538.16
conventional type bricks having crushing strength not less than 35 Kg/sq.cm.
in super structure above plinth level upto floor two level in cement mortar 1:6
(1 cement : 6 fine sand) for First Floor including the cost of all materials and
labour charges etc. complete.
28 Providing and laying half brick work using common burnt clay building 3.20 Sq.m. 684.26
conventional type bricks having crushing strength not less than 35 Kg/Sq.cm
in cement mortar 1:4 (1 cement : 4 coarse sand) in cement mortar in super
structure for Ground floor including the cost of all materials and labour
charges etc. complete.
29 Providing and fixing 150 mm wide, approved quality chicken wire mesh at 252.40 Sq.m. 295.12
junction of brick work and RCC work or two dissimilar surfaces, at all heights
fixed by nails, rowal plugs or tag by cement mortar 1:3 before applying the
plaster, including curing etc. complete
30 Providing 15mm thick cement plaster in single coat on rough (similar) side of 229.60 Sq.m. 226.01
single or half brick walls / concrete wall for interior plastering and finished
even and smooth along with floating coat of neat cement slurry etc. complete
in Cement mortar 1:4 (1-cement : 4 sand) at Ground floor.
31 Providing 15mm thick cement plaster in single coat on rough (similar) side of 52.80 Sq.m. 249.90
single or half brick walls / concrete wall for interior plastering and finished
even and smooth along with floating coat of neat cement slurry etc. complete
in Cement mortar 1:4 (1-cement : 4 sand) at First floor.
32 Providing 10 mm. thick smooth cement plaster in single coat for plastering on 67.50 Sq.m. 208.97
ceiling and soffits of stairs and finished even and smooth along floating coat
of neat cement slurry in cement mortar 1:4 (1 cement : 4 sand) (1) Plaster at
Ground floor.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
33 Providing 20mm thick double coat sand faced cement gutka plaster on walls 510.00 Sq.m. 345.75
with 1 x 1 cm grooves consisting of 12 mm thick backing coat of C.M. 1:3 (1
cement : 3 sand) and 8 mm thick finishing coat of C.M. 1:1 (1 cement :
sand) including 1 cm x 1 cm grooves etc. complete as directed by Engineer-in-
34 Providing throating or plaster drip and moulding to R.C.C. Chhajja. 14.40 Rmt. 43.05
35 Applying two coats of acrylic lappy - putty & two coats of primer of approved 349.90 Sq.m. 40.59
brand and manufacture on new wall surface to give an even shade including
thoroughly brushing the surface free from mortar dropping and other foreign
matter and sand papered smooth for all floors.
36 Wall painting (three coats) with plastic emulsion paint of approved brand and 282.40 Sq.m. 125.40
manufacture on undecorated wall surfaces to give an even shade including
thoroughly brushing the surface free from mortar droppings and other foreign
matter and sand papered smooth for all floors.
37 Wall painting (two coats) with plastic emulsion paint of approved brand and 67.50 Sq.m. 130.93
manufacture on undecorated ceiling surface to give an even shade including
thoroughly brushing the surface free from mortar droppings and other foreign
matter and sand papered smooth for all floors.
38 Finishing wall with weather proof exterior 100% acrylic emulsion paint with 721.00 Sq.m. 120.26
one coat of primer on wall surface to give an required shape even shade after
thoroughly brushing the surface to remove all dirt, dust and remains of loose
powdered materials etc. complete for all floors.
39 Providing and filling with good quality sinder (steam coal) as directed by 2.70 Cum 572.06
engineer in charge in sunks in layers of 15 cm thick including watering,
placing, ramming well etc. as directed for all floors.
40 Providing and fixing 35mm thick solid core wooden flush shutter confirming to 11.60 Sq.m. 4848.84
IS:2202 & ISI approved manufacturer, finished with 1mm thick laminates on
both sides of shutter, machine glued PVC beading on periphery, S. S.
handles and S. S. fixtures & locking arrangement of standard make of kich or
equivalent, on each shutter, fixed with minimum 4 Nos. 150mm high S.S.
hinges. Sample & shade to be approved by the Architect.
41 Providing and fixing window having three shutter glass section and one 5.40 Sq.m. 4148.05
shutter mosquito net extruded colour anodized aluminum section equivalent
to Jindal series E(30 mm) with sections numbered : frame bottom with weep
holes- 21198, frame top & side - 21204, shutter top & bottom- 20993, shutter-
inter lock - 20550, shutter side (handle) - 20553, with 5 mm thick transparent
tinted float glass, with rubber gasket, air lock strip and finishing joints with
transparent silicon sealant, with standard extruded colour anodized aluminum
42 Providing and fixing window having two shutter glass section and one shutter 3.00 Sq.m. 4490.62
mosquito net extruded colour anodized aluminum section equivalent to Jindal
series E(30 mm) with sections numbered : frame bottom with weep holes-
20928, frame top & side - 20837; shutter top & bottom- 20993, shutter-inter
lock - 20550, shutter side (handle) - 20549, with 5 mm thick transparent tinted
float glass, with rubber gasket, air lock strip and finishing joints with
transparent silicon sealant, with standard extruded colour anodized aluminum
43 Providing & fixing in position standard extruded approved colour anodized 0.80 Sq.m. 3944.65
Alluminum Ventilator with 3mm thick Bajari figure adjustable tinted louvers
glass fixed to alluminium strip blade including fixtures, fastening, labours and
equipments as per detailed drawing as directed. For Ventilators V1, V2.
44 Providing and laying 24" x 24" Vitrified 8 mm thick tiles flooring over 20mm 48.70 Sq.m. 1467.72
(average) base of cement mortar 1:6 (1 cement : 6 coarse sand) on new
surface or fixing on existing flooring by adhesive material including
dismentaling of existing flooring and jointed with color cement slurry including
finished with flush pointing & cleaning the surface etc. complete for Anti skid.
45 Providing and laying Vitrified tiles 8 to 10 mm thick, 24'' x 24'' in skirting, risers 5.10 Sq.m. 1592.40
of steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse
sand) and jointed with white cement slurry.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
46 Providing and laying Machine cut, free edges, mirror polished Granite Slab 1.10 Sq.m. 2368.24
flooring over 18mm (Average) thick base of cement mortar 1:6 (1-cement : 6-
coarse sand) laid over and jointed with grey cement slurry mixed with pigment
to match the shade of slab including rubbing and polishing etc. complete. (A)
18mm thick.
47 Providing and laying machine cut, free edges, mirror polished Granite Slab 0.60 Sq.m. 2338.22
18mm thick in risers of steps, skirting, dedo and pillars laid on 10mm thick
cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement
slury mixed with pigment to match the shade of slab including rubbing and
polishing etc. complete.
48 Providing and laying broken china mosaic flooring for terrace using 12 mm to 133.30 Sq.m. 779.70
20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain
or slope and to be tempered to bring mortar creme out upto surface using
white cement including rounding off junctions and extending them upto 15 cm
along the wall, clearing with water and oxalic acid etc. as directed.
49 Providing and laying Anti skid Ceramic tiles 8mm to 10mm thick, 30cm x 6.00 Sq.m. 1195.54
30cm in flooring treads of steps and landing laid on a bed of 12 mm thick
cement mortar 1:3 (1 cement : 3 coarse sand) finishing with flush pointing in
white cement. Pattern, Colour & Shade approved by Architect or Engineer in
50 Providing and laying Ceramic tiles 6mm thick in flooring treads of steps and 39.50 Sq.m. 1045.60
landing laid on a bed of 12 mm thick cement mortar 1:3 (1 cement : 3 coarse
sand) finishing with flush pointing in white cement.
51 Providing and laying polished Kota stone slab flooring over 20mm (average) 3.60 Sq.m. 1095.71
thick base of cement mortar 1:6 (1-cement : 6 coarse sand) or L.M. 1.1.5 (1-
Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry
mixed with pigment to match the shade of slab including rubbing and
polishing etc. complete. (B) 30mm thick.
52 Providing and laying Ceramic tiles 6mm thick in skirting risers of steps and 20.70 Sq.m. 1045.60
dedo on 10mm thick cement plaster 1:3 (1-cement : 3 coarse sand) and
jointed with white cement slurry.
53 Providing Plinth Protection to building including excavation and laying cement 26.40 Sq.m. 2520.98
concrete 1:3:6 using stone aggregates of 40mm nominal size in foundation
layer 150 mm thick+ 125mm thick sand layer below pre-cast rubber dye inter
locking concrete block 60mm thick with grade of concrete M-300 pneumatic
compressed by mechanically pressed and as per approved design including
75mm sand layer for levelling and filling the joint with sand in proper line and
level etc. complete including providing and fixing precast concrete kerb stone
of grey cement based concrete block 30cm length, 30cm height and 15cm
thick made of M-250 grade concrete as per approved design and including
excavation for fixing in proper line and level, filling the joint with C:M 1:3 (1
cement : 3 fine sand) etc. complete.
54 Providing and laying cement concrete flooring 1:2:4 (1 cement : 2 coarse 133.30 Sq.m. 347.42
sand : 4 graded stone aggregate 20mm nominal size) laid in one layer and
finished with a floating coat of neat cement. (B) 50 mm thick.
55 Providing and fixing mirror polished 18mm thick Granite with full round edge 53.90 Sq.m. 2220.78
and polished of approved quality in cladding on sill and around the doors /
windows / ventilation with 20 mm thick cement plaster CM (1:4) and fixing with
cement slurry & adhesive including moulding of exposed edges as directed by
engineering in charge etc. complete.
56 Providing and fixing M.S. Grills of required pattern to frames of windows etc. 48.40 Sq.m. 3095.77
with M. S. flats at required spacings and frame alround having min. weight of
grill 25 kg/sq.m, square or round bars with round headed bolts and nuts or by
screws including priming coat of approved quality and two coats of enamel
paint, as directed by engineer in charge (A) Plain grill.
57 Providing, erecting and fixing double coated I.S.I. Mark P.V.C. water tank of 2000.00 Litre 3.95
required capacity each with all necessary fittings and connection etc.
complete on terrace as directed.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
58 Providing, laying and jointing in true line and level I.S.I. mark 110mm dia. 25.00 Rmt. 876.90
U.P.V.C. pipe (Type B) confirming to IS 13592-1992 with one end plain and
other end socketed with rubbering & fitting conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of
the size 110 mm diameter x 149 mm length x 145 mm height at every
mm center to center or shall be concealed in walls as directed including
necessary fittings such as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement including cost of all materials.
59 Providing, laying and jointing in true line and level I.S.I. mark 160mm dia. 25.00 Rmt. 834.38
U.P.V.C. pipe (Type B) confirming to IS 13592-1992 with one end plain and
other end socketed with rubbering & fitting conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of
the size 160 mm diameter x 210 mm length x 196 mm height at every
mm center to center or shall be concealed in walls as directed including
necessary fittings such as bends, shoes etc. including testing of pipes and
joints and jointed with adhesive solvent cement including cost of all materials.
60 Providing, laying and jointing in true line and level I.S.I. mark 50mm dia. 75.00 Rmt. 195.67
U.P.V.C (Sch-40) for cold water including fitting as approved by Engineer in
charge. Pipe shall be fixed on the wall with held of clamp at every two meter
c/c shall be concealed or open as directed including necessary fitting etc.
including testing of pipe and joints and fixing the same with adhesive solvent
including cost of all materials.
61 Providing, laying and jointing in true line and level I.S.I. mark 40mm dia. 30.00 Rmt. 148.12
U.P.V.C (Sch-40) for cold water including fitting as approved by Engineer in
charge. Pipe shall be fixed on the wall with held of clamp at every two meter
c/c shall be concealed or open as directed including necessary fitting etc.
including testing of pipe and joints and fixing the same with adhesive solvent
including cost of all materials.
62 Providing, laying and jointing in true line and level I.S.I. mark 25mm dia. 40.00 Rmt. 91.84
U.P.V.C (Sch-40) for cold water including fitting as approved by Engineer in
charge. Pipe shall be fixed on the wall with held of clamp at every two meter
c/c shall be concealed or open as directed including necessary fitting etc.
including testing of pipe and joints and fixing the same with adhesive solvent
including cost of all materials.
63 Providing, laying and jointing in true line and level I.S.I. mark 15mm dia. 40.00 Rmt. 72.65
U.P.V.C (Sch-40) for cold water including fitting as approved by Engineer in
charge. Pipe shall be fixed on the wall with held of clamp at every two meter
c/c shall be concealed or open as directed including necessary fitting etc.
including testing of pipe and joints and fixing the same with adhesive solvent
including cost of all materials.
64 Providing and fixing concealed center point to wall ceiling & floor I.S.I. mark 20.00 Rmt. 447.72
C.P.V.C. (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal
for potable water of following dia. nominal bore tube fittings and clamps
including making good the wall, ceiling and floor etc. complete. (E) 40mm dia.
65 Providing and fixing concealed center point to wall ceiling & floor I.S.I. mark 20.00 Rmt. 253.82
C.P.V.C. (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal
for potable water of following dia. nominal bore tube fittings and clamps
including making good the wall, ceiling and floor etc. complete. (C) 25mm dia.
66 Providing and fixing concealed center point to wall ceiling & floor I.S.I. mark 30.00 Rmt. 170.36
C.P.V.C. (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal
for potable water of following dia. nominal bore tube fittings and clamps
including making good the wall, ceiling and floor etc. complete. (A) 15mm dia.
67 Providing and laying (to level or slopes) and jointing reinforced concrete light 100.00 Rmt. 678.02
duty non pressure pipes I.S. Class NP-2 of the following internal diameter with
collars and butt ends prepared for collar joints including testing of joints
complete. (D) 300mm dia.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
68 Providing, laying and jointing in true line and level I.S.I. mark 75mm dia. 50.00 Rmt. 756.22
U.P.V.C. SWR Type B pipe confirming to IS 13592-1992 with one end plain
and other end socketed with rubbering and fitting conforming to ISI 14735-
1999 of approved make for drainage system pipe line, pipe shall be jointed
with each other with rubber lubricant, pipe shall be fixed on wall using of PVC
clamp at every 2000 mm c/c or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent cement including cost of all
materials.
69 Providing and fixing cast iron spigot and socket soil, waste and ventilating 20.00 Rmt. 741.01
pipes of the following nominal size. (B) 75mm dia.
70 Providing and fixing cast iron spigot and socket soil, waste and ventilating 28.00 Rmt. 892.39
pipes of the following nominal size. (C) 100mm dia.
71 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm 6.00 No. 586.27
diameter with jali of the following nominal diameter of self cleaning design
with C.I. screwed down or hinged grating including the cost of cutting and
making good the walls.
72 Providing and fixing wash down water closet (European type W.C. pan) with 1.00 No. 3631.34
integral P and trap including jointing the trap with soil pipe in cement mortar
1:1 (1 cement : 1 fine sand) including providing and fixing plastic seat cover
for wash down WC with CP brass hinges and rubber buffers back plastic seat
and including providing and fixing PVC flushing tank with a pair of C.I. or M.S.
bracket with complete fitting such as lead valve siphon 15 mm dia. brass ball
valve with polythene float C.P. brass handle unions and couplings for
connection with inlet out let and over flow pipes 40 mm dia. porcelain
enameled flush bend including cutting holes in walls and making good the
same connection the flush bend with cistern and closet vitreous china etc.
completed.
73 Provision, supplying and fixing white vitreous china W.C. squatting pan Orrisa 1.00 No. 1638.03
type 580 x 400 size with 100mm P or S trap, 25mm dia. C.P. Brass flush
valve and G.I. inlet connection etc. complete. (A) Vitreous china long pattern
white or color.
74 Providing and fixing brass screw down stop tap. (A) 15mm dia. as approved 4.00 Each 205.83
by Engineer in charge.
75 Providing and fixing ball cock of approved quality as directed. (A) Copper 2.00 Each 189.84
Metal (iv) 50mm dia.
76 Providing and fixing wash basin with single hole for pillar tap with C.I. or M.S. 2.00 Each 1451.48
brackets painted white including sutting holes and making good the same but
excluding fittings. (A) Vitreous China (ii) Flat Back washbasin 550 mm x
400mm size. (i) In white colour.
77 Providing and fixing C. P. brass waste for wash basin or sink. (A) 32mm dia. 2.00 Each 67.91
78 Providing and fixing M.I. fisher union for washbasin or sink. (A) 32mm dia. 2.00 Each 78.75
79 Providing and fixing 600mm x 450mm bevelled edge mirrror of superior glass 2.00 Each 859.41
mounted on 6mm thick A.C. sheet or plywood sheet and fixing to wooden plug
with C.P. brass screws and washers.
80 Providing and fixing C.P. brass towel rail complete with C.P. brass brackets 2.00 Each 616.42
fixed to wooden plugs with C.P. brass scews (B) 600mm x 20mm size.
81 Providing and fixing screw down bib taps of following size.(A) Brass screw 2.00 Each 214.81
down bib tap polished bright. (ii) 20mm dia. as approved by Engineer in
82 Providing and fixing pillar tap, capstan head, screw down high pressure with 2.00 Each 308.73
screws, shanks and back nuts. (i) 15mm dia. as approved by Engineer in
83 Providing and fixing in position 300 mm high, 300 mm wide English / Gujarati 30.00 Each 707.00
letters made from 1.0 mm thick stainless sheet as directed by Engineer-in-
charge with all necessary tools & plants etc. complete.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
84 Providing and fixing Urinal of approved quality including connection with trap 2.00 Each 1635.22
and with integral longitudinal flush pipe. (A) Squatting plate pattern white
earthenware 550mm x 300mm.
85 Providing and fixing Rubber plug for sink or wash basin. 2.00 Each 17.15
86 Providing and fixing chromium plated brass half turn flush cock of approved 1.00 Each 263.77
quality including fixing in pipe line etc. complete (ii) 25mm dia.
87 Providing and fixing S.W. Gully trap with C.I. grating brick masonry chamber 6.00 Each 1246.92
and water tight C.I. cover with frame of 300 x 300 mm size (inside) with
standard weight (i) square mouth traps (B) 150 mm x 100 mm size P or R
88 Constructing brick masonry chamber for underground C.I. Inspection chamber 2.00 Each 2932.93
and bends with bricks having crushing strength not less than 35 Kg/cm2 in
C.M. 1:5 C.I. cover with frame (light duty) 455mm x 610mm internal
dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg.) (R.C.C. top slab with 1:2:4 mix (1-
cement : 2 coarse sand : 4 graded stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed concrete etc.
complete. (i) Inside dimensions 455mmx 610mm and 450mm deep for single
pipe line.
89 Constructing brick masonry chamber for underground C.I. Inspection chamber 1.00 Each 3660.76
and bends with bricks having crushing strength not less than 35Kg/Cm2 in
C.M. 1:5 C.I. cover with frame (light duty) 455mm x 610mm internal
dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg.) (R.C.C. top slab with 1:2:4 mix (1-
cement : 2 coarse sand : 4 graded stone aggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished
smooth with a floating coat of neat cement on walls and bed concrete etc.
complete. (ii) Inside dimensions 500mm x 700 mm and 450mm deep for pipe
line with one or two inlets.
90 Providing cement vata (10cm x 10cm size) quarter round in cement mortar 147.90 Rmt. 24.28
1:1 including neat cement finishing watering etc. complete.
91 Providing and fixing polished 18 mm thick black granite with full round edge 1.50 Sq.m. 2719.93
and double side polished of approved quality in between urinal and fixing with
cement slurry & adhesive including moulding of both exposed edges as
directed by engineering in charge etc. complete.
92 Constructing platform of 18mm thick Polished Black Granite at top and 25mm 0.90 Sq.m. 4362.19
thick Kota stone slab one side polished at bottom with cementing materials /
adhesives including making necessary grooves in walls with Vertical Kota
stone (25mm thick) support of height 0.70m every 60 cm center to center or
as required including one Kitchen sink and all labor material of approved
quality including full moulded round front edge granite strip of one side
polished and jointed with grey cement slurry including rubbing and polishing
etc. complete for all floors.
93 Clearing and grubbing road land including uprooting rank vegetation grass 0.10 Hect. 28455.09
bushes, shrubs, sapling and trees girth up to 300 mm removal of stumps of
trees cut earlier and disposal of unserviceable materials (C) By mechanical
means in area of light jungle.
94 Earthwork in cutting including preparing the slope, camber and stacking or 169.00 Cum 317.35
utilising the cutting stuff in bank as directed upto 200 meters from the end of
cutting with all lead and lift. (ii) Soft rock not requiring blasting.
95 Filling available excavated earth (excluding rock) in trenches plinth side of 85.00 Cum 136.92
foundation etc. in layer not exceeding 20 cm in depth consolidation each
deposited layer by ramming and watering etc. complete.
96 Rolling and watering of earthwork in layers with power roller including filling in 85.00 Cum 22.96
depressions which occur during the process as directed by Engineer incharge.
97 Providing & laying weep hole in abutments and returns by using A.C. pipe of 68.00 Each 86.73
100mm including laying in proper grade and jointing the completed as per
detailed specification.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
98 Providing and fixing 610mm dia. Barbed Razor Tape Concertina Coil made 70.00 Rmt. 258.58
from hot dip galvanized spring steel high tensile wire (UTS: 145-160Kg/Cm2,
Zncoating 250-300g/m2, Diameter- 2.59+/-0.05mm), with blade of galvanized
Iron of 0.50 mm thick and width 19mm, with coverage / openable length of
10mtr/coil, including providing and fixing with clips, wires, bolt set con M.S.
angle posts, with all materials, labour, tools, tackles, etc. as per direction of
Engineer In-charge, for work at all level.
99 Box cutting the road surface to proper slop and camber for making a base of 44.50 Cum 109.41
road work including removing the excavated stuff and depositing on the road
side slope as directed for all lead and lift.
100 Providing and laying compacted WBM of Grading-II MCBT metal of size 45 to 16.00 Cum 1895.77
63mm in required layers including using 13% stone screening, 13.2mm size
and 7% stone dust as filler including spreading, watering & consolidation by
vibratory roller etc. complete.
101 Providing and laying controlled cement concrete M-200 and curing complete 18.50 Cum 4204.41
including the cost of formwork and excluding reinforcement for reinforced
concrete work in (A) Foundations, footings and Mass concrete.
102 Compaction and finishing of cement concrete road by trimix process providing 97.00 Sq.m. 65.65
extra labour charges for the trimix vacume dewatering service process on
cement concrete road surface by using vacuum dewatering pump floater
surface vibrator including making grooves and rough finish to surface
including leveling etc. complete.
103 Providing and laying homogeneous grey cement based concrete kerbing of 48.00 Rmt. 374.92
size 30 cm x 30 cm x 10 cm size as per detailed drawing having grade of
concrete M-25 grade, including necessary excavation, BBCC 1:5:10, 7.5 cm
as per detailed drawing fixing in line and level, filling joints in C.M. 1:3 with
smooth finished, white washing three coats etc. complete as directed by
Engineer in charge.
104 Supplying premoulded bituminous joint filler 12 mm thick. 3.00 Sq.m. 553.79
105 Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8 2.50 Cum 2766.67
hand broken stone aggregates 40 mm nominal size) and curing complete
excluding cost of formwork in (A) Foundation and Plinth
106 Providing corrugated double coated trafford sheet roofing fixed with 14.00 Sq.m. 1035.68
glavanished iron J or L hooks, bolts and nuts 8mm diameter with bitumen and
G.I. limpet washer or G.I. limpet washer filled with white lead complete
excluding the cost of purlins, rafters and trusses. (1) 0.80 mm thick sheet.
107 Providing and fixing precast Rubber Dye / steel dye inter locking concrete 12.00 Sq.m. 706.77
block 60mm thick with grade of concrete M-300 pneumatic compressed /
vibrated mechanically and as per approved design confirming to IS 15658 :
2006 including 35 mm sand layer for levelling and filling the joint with sand in
proper line and level as per guidlines of IRC : SP 63-2018 etc. complete.
108 Drilling of pilot bore hole of size 250 / 300 mm diameter at above site by mud 150.00 Mtr. 865.57
finish direct rotary rig etc. complete.
109 Reaming of 250 / 300 mm diameter pilot bore hole to size 450 mm diameter 150.00 Mtr. 398.95
including assembling, lowering housing, casing strainer pipes with gravel
packing and clay ball packing etc. complete.
110 Providing 600 CFM / 150 PSI capacity air compressor up to availability of 1.00 Job 22427.05
sand free discharge (Minimum 6.0 Hours)
111 Supply of reducer made from 6 mm thick plate (M.S.) for ERW pipe of size (ii) 1.00 No. 1884.27
200 mm dia. x 250 mm dia. x 600 mm length
112 Supply of 200 mm diameter V-wire screen pipe of slot size 1.0 mm nominal 12.00 Mtr. 1767.28
hole etc. complete
113 Supply of M.S. bore clamps with 3 holes on either side with nuts and bolts of 1.00 Pair 1643.99
standard make and suitable size (g) 750mm x 75 mm x 16 mm flat to 200 mm
dia. pipe.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
114 Supply of Bore Plug having 100 mm height made from M.S. plate with 3 holes 1.00 No. 782.57
at equal distance on circumference for nut- bolts type, locking arrangement
with nut- bolts & lock nuts of standard make complete. (B) from 5 mm thick
M.S. plate (for top also) (ii) suitable for 200 mm dia. pipe.
115 Supply of M.S. Bail Plug having length of 0.45 mtr from medium class pipe as 1.00 No. 851.04
per I.S.S. suitable for (d) 200 mm diameter pipe etc. complete.
116 Supply of Steel Bent plates suitable to ERW pipe for (b) 200 mm diameter 4.00 No. 67.26
and 150 x 150 x 6 mm size etc. complete.
filling etc. complete.
118 Charges for uptron make Electrologger (with carting) of pilot bore hole etc. 1.00 Hour 12120.00
119 Charges for Geo Hydrological ground water investigation including water 1.00 Job 14428.86
sample chemical analysis etc. complete.
120 Supplying submersible pump set suitable for bore of 150 mm. dia. or more 1.00 Each 35590.38
having three phase motor capacity not more than 7.5 H.P. with following
capacity (a) (12 stage) 280 to 240 LPM discharge at 90 to 104 mtrs. head
respectively suitable for 50mm dia. delivery pipe
121 Providing and erecting PVC corrugated flexible conduit with required numbers 125.00 Mtr. 26.26
of coupling, PVC bushes, Check nuts etc. complete of following sizes. (3)
mm diameter.
122 Lowering of submersible motor pump set complete with required. Nos. and 1.00 Job 2568.43
size of casing pipes erected by means of proper chain pulley block & pipe
wrenches after checking of threads of each pipe with coupling to take the load
of the pump set and pipe assembly filled up with water. (b) Above 60 Mtr and
up to 120 Mtr
123 Supplying and erecting approved make motor control cubical panel (Direct - 1.00 Each 8710.24
on - line) made from 16 G. CRCA sheet duly epoxy powder painted inside and
outside with hinged doors and locking, arrangement consisting of suitable
size of ON-OFF isolator (AC - 3/23 duty) main fuses, single phasing
preventer, indicating lamps for R - Y - B phases, overload relay, automatic
incoming, wires duly socket crimped, main contactor & overload relay, start -
stop push buttons, to be erected on angle iron frame grouted on wall as
directed. The isolator, overload relay & contactors will be of L & T, Siemens or
BCH make only. (a) DOL up to 7.50 H.P.
124 Supplying and erecting XLPE (IS: 7098) (I)-88 ISI unarmoured copper cable 140.00 Mtr. 130.29
1.1 KV grade to be erected as directed of following size. (E) 3 core 2.5 Sq.mm.
125 Providing and supplying ISI mark CI D/F Butterfly Valves as per IS:13095 1.00 No. 1868.50
(Latest Edition) of following class and diameter including all taxes, insurance,
transportation, freight charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores, stacking etc. complete. (B) Butterfly
valves IS 13095 with ISI mark PN 1.6 (1) 50mm
Electrical Items
126 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm 14.00 Pt 485.81
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length, in below type of pipe erected with 6A
Modular type switch / bell push & accessories and earth continuity of following
type, erected on PVC / Metallic / Wooden box, single mounting base frame
covered with textured / metallic / white front plate modules erected on / in wall
/ ceiling as per pipe erected, with necessary lamp holder / ceiling rose / H.D.
Connector as directed.(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III.
(f) with medium class Rigid PVC pipe and accessories erected concealed in 6.00 Pt 242.91
wall / ceiling complete Cat. III (Half Point for Bathroom and WC)
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
127 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both 6.00 Pt 674.68
are of ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected with 6A Modular type
switch and hum free EME step type electronic fan regulator mounted and
accessories with earth continuity of following type erected on PVC / Metallic /
Wooden box, single mounting base frame covered with textured / metallic /
white front plate modules erected on / in wall / ceiling as per pipe erected with
necessary ceiling rose / H.D. Connector as directed. (f) with medium class
Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
128 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both 9.00 Pt 510.05
are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected complete with Modular
type switch & 5 pin Plug erected on PVC / Metallic / Wooden box covered
with appropriate front plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories. [I] For 6A Plug and 6 a switch with
2-1.5 sq.mm Cu. Wire from nearby switch board / mcb db board (f) with
medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete Cat. III
129 Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin 26.00 Pt 257.55
socket erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured / metallic / white front plate modules erected on / in wall
/ ceiling with following type accessories Cat. III
130 Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire 4.00 Pt 603.98
of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires erected in below type of pipe with 6A
Modular type switches and following type of accessories erected on PVC /
Metallic / Wooden box, single mounting base frame covered with textured /
metallic / white front plate modules erected on / in wall / ceiling as per pipe
erected. with necessary batten / angle holder or ceiling rose or H.D.
Connector as directed. (f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III
131 Providing following type of Modular Type Accessories mounted with PVC / 1.00 Ea 160.59
metallic / Wooden box, single mounting base frame covered with textured /
metallic / white front plate, modules erected with necessary connections as
per site situation directed by Engineer In charge.(3) Two Pin/RJ-11 Telephone
Socket [A] For One Gang Cat. III
(4) TV Co-axial Socket outlet Cat. III 1.00 Ea 160.59
(5) Electronic hum Free steps EME Fan regulator. Cat. III 2.00 Ea 398.95
(7) Blank Plate Single Cat. III 16.00 Ea 25.25
(9) 16 Amp. SP one way switch Cat. III 8.00 Ea 180.79
(10) 6/16Amp. Universal socket Cat. III 8.00 Ea 199.98
132 Providing and erecting ISI mark Medium class RIGID PVC PIPES of following 24.00 Mtr. 24.24
size complete to be erected on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution & clamps with following
dia of pipes, in approved manner as directed (a) 20 mm
133 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI 20.00 Mtr. 62.62
marked stranded Copper conductor wire in following type of pipe to be
erected concealed in / flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth
continuity of following size (A) With medium class Rigid PVC pipe and
accessories (a) 2 wire 1.5 sq.mm
(b) 2 wire 2.5 sq.mm 260.00 Mtr. 82.82
134 Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI 64.00 Mtr. 112.11
marked stranded Copper conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth continuity of following size
(A) with medium class Rigid PVC pipe and accessories (a) 2 wire 4 sq.mm
(b) 2 wire 6 sq.mm 30.00 Mtr. 147.46
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
135 Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv 44.00 Mtr. 46.46
grade ISI marked copper wires of following size to be erected as directed.(e)
1.50 Sq.mm 3 core round PVC sheathed
136 Providing & erecting approved make following size of TV Co-axial flexible 12.00 Mtr. 62.62
cable comprising inner conductor of solid bare copper insulated with Foam
PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids
@ suitable coverage overall sheathed with black PVC insulation.(e) RG-11
137 Supplying & erecting approved make Telephone Cable electrolytic copper 12.00 Mtr. 20.20
conductor PE insulation twisted in two pairs & wrapped with FRLS PVC tape
& sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone
wiring & confirming to C-DOT erected in existing pipe of following size of
conductors & nos.of pairs with necessary connections. [A] Conductor Size
mm (a) Unarmoured (2) Two Pairs
138 Bakelite adopter for Holder to be erected. 17.00 Ea 9.09
139 Decorative call bell Ting-tong box type 250 volts complete erected 1.00 Ea 71.71
140 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 17.00 Ea 373.70
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more than 0.95, THD <
15%, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt, LED
LED driver efficiency > 85% (fitting required LM-79 & LM-80 Certificates)
(NOTE: Below description have shown ranges of Wattage capacity of LED
ranges shown) (A) Tube Light with integral driver (iv) 22-24 Watts, Surge -
2KV, IP-20, conventional 4 feet Cat-lll
141 Supplying and erecting led lamps with following wattage capacity of 220 to 7.00 Ea 188.87
240 voltage, minimum 15000 burning hours life, 500 V in built-surge
protection, Polycarbonate diffuser, mounting suitable for E14 / E27 / B22 lamp
holders, pf >= 0.5 (A) LED Lamps integral type, with PC diffuser suitable
LAMP holder (iii) 10 to 15 watts Cat-lll
142 Supplying and erecting LED street light / Flood light fittings with High power 8.00 Ea 4997.48
White LEDs wattage of 3 Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with toughened
glass with company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10%, CCT 3000 K to 5700K, Uniformity ratio
>0.45, Luminaire efficacy> 100 lumens/watt. LED driver efficiency > 85%.
(fittings required LM-79 & LM-80 certificates) (NOTE: Below description have
shown ranges of Wattage capacity of LED fittings. The Engineer incharge
(IP-65), Surge protection -4KV integral and Light must have 440VAC line
supply with over-voltage protection. (ii) above 48 to 60 Watts Cat-lll
(C) Post Top Lantern LED fitting comprises of finish cast aluminum spigot and 2.00 Ea 4819.72
spun aluminum canopy fixed with opal polycarbonate, pipe arrangement for
vertical mounting driver and accessories wired upto terminal block. IP 65 (ii)
32-40W Cat-lll
143 Providing and erecting Miniature circuit breaker single pole 0.5A to 2A system 10.00 Ea. 270.68
and having breaking capacity 10 KA to be erected in existing box confirming
to IS 8828/1996 with ISI Mark Cat III
144 Providing and erecting Miniature circuit breaker single pole 6A to 25A suitable 12.00 Ea. 112.11
to operate on 240 V A.C. system and having breaking capacity 10 KA to be
erected in existing box confirming to IS 8828/1996 with ISI Mark Cat III
145 Providing & erecting 240 V MCB double pole switch for motor & inductive load 5.00 Ea. 299.97
(C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing
box having following capacity (A) 6 to 32 Amp. Cat III
(B) 40 Amp. Cat III 5.00 Ea. 330.27
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
146 Providing & erecting 240 V MCB double pole switch for lighting Load (B 2.00 Ea. 278.76
Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box
having following capacity (A) 6 to 32 Amp.Cat III
147 Sheets steel powder coated enclosure suitable for incorporating One/Two 3.00 Ea. 176.75
148 Providing and erecting Sheet Steel powder coated MCB distribution board - 1.00 Ea. 1492.78
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs. (The DBs should be used of same company of
MCB to be used) suitable for (A) single phase incoming and horizontal single
phase outgoing (b) sheet steel double door (IP-43) (iv) 12 way
(v) 16 way 1.00 Ea. 1680.64
149 Providing and erecting Approved make RCCBs conforming to IS: 12640 and 1.00 Ea. 2235.13
having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V, 50Hz. having characteristic of
quick action & tripping with all advance feature & do not incorporate any
electronic component for following Max. rating erected as directed (ii)
Amps. DP Cat III
150 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 1.00 Kg. 794.87
151 Providing and erecting Pipe type earthing having 150 cms.long and 2.5 cms. 1.00 Ea. 368.65
dia. galvanised iron pipe with coupling and buch buried in specially prepared
earth pit complete with necessary 8 SWG earth wire.
152 For using salt and charcoal / coke as required for pipe type earthing. 1.00 Ea. 171.70
153 Supplying & erecting earth pit of minimum bore dia.150mm size approved 1.00 Ea. 4591.46
make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I. Pipes having Outer pipe dia. of
50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-
250 Micron galvanising, connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with high charge dissipation
suitable for following type of applications with chamber and heavy duty cover.
(A) (approved make OEM has to submit test certificate including value of
earth resistance of installation duly stamped and signed by agency and officer
Incharge has to ensure the value of earthing resistane mentioned in test
Certificate) & having back filling compound of (B) Inner chemical (CCM
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017,
Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2% (C) Back
fill Compound :- Earthing compound should be capable to retain moisture for
long time Necessary test report must be submitted by Agency.
(a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
154 Providing and erecting Steel cover as per drawing using 16 SWG M.S. sheet 0.20 Sq. 2560.35
of following depth, to house the switch gear etc. complete with locking Mtr.
arrangement and lock with duplicate keys per cupboard and door handles
erected with necessary support and painting. [One coat red oxide and two
coat enamel paint] (B) Without angle iron frame (i) For 25 cms. Depth
155 Providing and erecting Meter cover made from multi chamber hollow PVC 1.20 Sq. 3339.06
sections of 20 mm thick having all the corner joints with PVC solution angles Mtr.
without using any screws, nails shutters having required size of eye glass and
with necessary locking arrangement hinged with box. The back of meter box
should be fixed with timber. Hold fast for holding screws or nut bolts.
156 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable Aluminium 106.00 Mtr 92.92
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables. (B) 2 core 6 Sq.mm
(C) 2 core 10 Sq.mm 66.00 Mtr 126.25
157 Making trench in soft soil of suitable width of 90 cm deep for laying cable or 125.00 Mtr 55.55
locating the fault all over the run and back filling the same and making the
surface as normal ground.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
158 Providing & laying approved make Double walled corrugated pipes (DWC) of 177.00 Mtr 62.62
polyethylene (conforming to IS 14930 II) with necessary connecting
accessories of same material at required depth in existing trench for laying of
cable below ground / road surface for enclosing cable (A) 50 mm outer dia.
159 Providing and fixing heavy duty flange type brass cable gland with rubber ring 20.00 Ea 38.38
for PVC insulated armoured cable complete with out going tails, insulating
tape etc. for following size of cables. (B) 2 to 4 core 6 Sq.mm
(C) 2 to 4 core 10 Sq.mm 4.00 Ea 38.38
160 Solder less crimping type Aluminium lugs conforming to IS suitable for cable 40.00 Ea 6.06
of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
manner. (A) 1.5 / 2.5 / 4 / 6 Sq.mm
161 Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with 5.00 Ea 1948.29
double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm
sweep complete having 3 blades with aluminium blades with, canopy &
cm. down rod erected with earthing.(Make shall be approved by Engineer in
162 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe 5.00 Mtr 108.07
down rod erected duly painted for fan complete with proper insulation without
leakage and earthing.
163 Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the 10.00 Ea 108.07
RCC bars up to 50mm length each side and pierced through a 16 Gauge M.S.
box / Heavy Duty PVC box complete erected concealed in Ceiling with
necessary finishing.
164 Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan 10.00 Ea 18.18
165 Supplying & erecting approved make low noise decorative exhaust fan having 2.00 Ea 1703.87
square frame ABS body with inbuilt lowers & square frame.200mm with
RPM Cat.II
166 Supplying and erecting approved make Octagonal pole made from HR sheet 8.00 Ea 5556.01
steel. The pole should be made as per IS and shall be coated with hot dip
galvanizing as per IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min 6mm Hylam sheet,
standard profile 35mm x 7.5mm Din-Rail for MCB Mounting, stud type
terminal and arrangement for cable termination to be erected with suitable
foundation (Included) as per details given by manufacturer considering site
requirement. (B) 4 Mtr. Long 70 mm top x 130 mm bottom dia, 3 mm
thickness with 200mm x 200mm x 12mm base plate, 4-M16 Bolts and 450mm
long with necessary G.I. J bolts. Approx weight 37 kg
167 Supplying & erecting approved make SMC press moulded composite FRP 2.00 Ea 476.72
loop-in, loop-out approx. 2mm thick box complete with Bakelite connector
strip 5way (3P+N+E), DIN rail for mounting mob & hinged doors as per
requirement having locking arrangements with mounting clamp with nuts,
bolts & washers suitable for erection on pole with cable clamps & earth bolt of
following size of box. (C) 150mm x 125mm x 100mm [deep]
168 Supplying and erecting Street light pole bracket comprising main B Class GI 9.00 Ea 491.87
pipe of 4.2 cm/require outside dia. complete with suitable B Class G.I. sleeve
tubing of approx. 45cms.length and suitable for 76.5mm / 80mm / require size
of pole top having nuts and bolts for fixing the brackets and having spread of
0.5 mtr. Length with 110 deg.with vertical plane and suitable welded stiffener
reducer and nipple with check nut complete painted with one coat.of Red
oxide / PU base primer and two coats of Aluminium / PU paint. paint with
following nos of arms.[A] Single Arm bracket 0.5 Mtr
169 Supplying and erecting HYLAM sheet on existing angle iron frame.for 1.00 Sq. 771.64
following thickness (B) 4mm Mtr.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
170 Supplying & erecting approved make Digital time switch having lithium cell 6 1.00 Ea 3168.37
years operative and operate battery backup 1 channel day clock with
memory programme, suitable to operate on 240V + 5%, 16A with, floating
contacts Minimum switching setup time 1 minimum & LCD display. Also
comprised permanent ON/OFF switching. Programming switches & housed in
fire proof thermoplastic enclosure & transparent cover erected as required
with necessary connection erected as directed.
171 Supplying & erecting power contactor ,AC3 duty for time switch complete 1.00 Ea 1883.65
erected as per direction Cat III (B) 2 pole 250V 32 Amp.
172 Supplying & erecting approved make motor control cubical panel (Direct - on - 1.00 Ea 7722.46
line) made from 16 G. CRCA sheet duly epoxy powder painted inside and
outside with hinged doors and locking, arrangement consisting of suitable
size of ON- OFF isolator (AC - 3/23duty) main fuses, single phasing
preventer, indicating lamps for R- Y - B phases, overload relay, Automatic
incoming, wires duly socket crimped, main contactor & overload relay, start -
stop push buttons, to be erected on angle iron frame grouted on wall as
directed. The isolator, overload relay & contactors will be of L & T, Siemens or
BCH make only. (A) DOL up to 5.0 H.P.
173 S.I.T.C. of single phase submersible pump set suitable for 100 mm size or 1.00 Ea 18386.04
more dia bore well having motor capacity and discharge as under with
necessary panel box. Lifting and Lowering taken extra. (c) Motor rating 2 HP
(17 stage) pump having capacity of 106 LPM at 40 mtr head suitable for
mm dia. delivery pipe. Cat.II
174 Lowering of submersible motor pump set at the depth of following, complete 1.00 Per 1711.95
with required. Nos. and size of casing pipes erected by means of proper chain Job
pulley block & pipe wrenches after checking of threads of each pipe with
coupling to take the load of the pump set and pipe assembly filled up with
water (A) Up to 60 mtrs.
175 Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible 60.00 Mtr. 104.03
Submersible copper cable approved make of following size. (B) 3 Core x
176 Supplying of following size of STANDARD UPVC column pipe with coupler 40.00 Mtr. 179.78
and wire lock [B] 32 mm dia.
177 Supply of following size of TOP & BOTTOM accessories i.e. Adaptor set (CI) 1.00 Per 462.58
long, pump guard set, starter pipe Rubber ring for submersible pump & UPVC Set
column pipe as directed by Engineer - in - charge with necessary plumbing as
desired. [B] 32 mm dia
178 Supply, Installation, Testing & Commissioning of following size of Grid Tied
Solar Power Plant with Solar Panels (ALMM approved) : Frame Material :
Anodized Aluminum alloy Frame With Twin Wall Profile, Front Cover : High
Transmission Low-Iron Tempered Glass (AR Coated), High efficency and
positive power tolerance Pmax: 0/+5, Module Efficiency should be approx.
19.5%-22%, Normal operating temperature 45' C, Junction Box with
Waterproof IP67 & MC4 Compatible and Enclosed with Bypass diodes, 100%
Electroluminescence test to ensure error free Modules, Thep. temp. co-
efficient of the PV module shall equal or better than -0.45% degree C. Solar
PV modules of minimum fill factor 75% to be used. Unit Production:- More
than 4.5 Unit /kw /day (Actual) (1 Year Avg) with 10 year Product warranty
and 25 year Linear Power Warranty includes all mechanical and electrical
parameters of the Solar panel. Modules must be complied to the DCR
(Domestic content requirements). The Ration of AC to DC is 5:6 for the
Installation capacity which are given in AC KW.
Solar Inverter : MPPT Range: MPPT Range : 80-1000 V, Max efficiency :
97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤ 4000, O/p
Power Factor: ~1, O/P THDi : <3%, Operating Tempreture Range :- 25~60°C,
Integrated protection of Inverter are Anti-islanding Protection, Input Reverse
Polarity Protection, Insulation Resistor Detection, Ground fault protection,
Residual Current Monitoring Unit, Output Over Current Protection, Output
Short Circuit Protection, Output Over Voltage Protection, PV array string fault
Protection. Protection Degree: IP65, User Interface LCD & APP, Datalogger &
Communication: GPRS / Wi-Fi.
It. Rates in Total
Description of Item Qty. Unit
No. Figure Amount
Module Mounting Structure: The mounting (Rectangular pipe / square pipe /
circular pipe) with requisite cross bars, nuts and bolts, etc. shall be Hot deep
galvanized with minimum 80micron coating. The Rectangular / square
/circular hollow pipe section used for the structure should have a minimum
thickness of 2.0 mm. other than above, the material thickness should be
minimum 2.5 mm. A certificate of a structural engineer certifying the strength
and stability of the mounting structure to withstand the weight and wind speed
of 150 km/hour throughout the life span of 25 years of the system, shall be
submitted by the vendors. Hot Dipped Galvanized steel coils. suitable
arrangement for base plate for foundation , solar panel mounting, the
structure should be suitable for carry the load of solar panel,wiring, sprinkler
system etc. with necessary foundation work/wall mount, j bolt, anchor fastner
etc. the nut bolt used for installtion of stucture should be (SS 304) quality.
The ground clearance of the bottom most edge of solar panel shall not be
less than 300 mm to 1200 mm or as per site’s technical / feasibility
requirement.
a. Column –The minimum section (thickness) should be 60MM x 40MM
b. Rafter - The minimum section (thickness) should be 60MM x 40MM
c. Purlin - The minimum section (thickness) should be 40MM x 40MM Balane
of System with necessary Swichgears (suitable size and protection of ACDB
& DCDB), inter connecting wiring, earthing system as per the CEIG drawing
approval, lightining arrester system as per the CEIG drawing approval, all
liasoning work with various Govt. Department like state nodal agency,
DISCOM & CEIG is included in agency scope.
(Excluding All charges namely GEDA Application fees, Solar connectivity
charges, Meter connectivity charges, Meter testing charges and system
stability / strenthning charges)
(A) Grid Tied Solar Power System: 1 - 6 kW (Single phase) 3.00 Per 46648.87
Total Rs.
i.e. Rs. Fifty Six lacs Fifty Seven thousand Nine hundred Twenty Six and Eighty Eight paisa only.
I/We am/are willing to carry out the work @ ______________ % above/below percent (Should be written
in figures and words) of the estimated rate mentioned above. Amount of my /our tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
Net Rs. ___________________________ Total Rs. ________________________
In words ____________________ In words ____________________
1. The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-
Charge for which no extra payment shall be made.
2. The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3. GST and Income tax TDS will be deducted at a source while making payments of bills.
4. In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-
10/2017 Cement Consumption/16/C, Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is
a change as per actual mix design the cost of difference of cement consumption have been deducted from the
rate of original item at the rate of input rate mentioned in all the tender.
5. The Contractor will have to submit the all required mix design at his own cost before execution as
directed and to be approved from the Engineer in charge.
Above all items of "Schedule-B" with Item Description, Unit, Rate & Amount have verified by me and found
Deputy Executive Engineer Sr. Divisional Account Officer Executive Engineer
Lunawada (R & B) Sub Division, Mahisagar (R & B) Division, Mahisagar (R & B) Division,
Lunawada Lunawada Lunawada
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD Book - D type Mamlatdar Qtrs Kadana.pdf
BOQ - D type Mamlatdar Quarters at Kadana.pdf
Specification Index.pdf
General Techical Specifications.pdf
Electrical - D type Mamlatdar Qtrs Kadana.pdf
GRs.pdf
E Tender Notice - D type Mamlatdar Qtrs Kadana - 2nd.pdf
Download all tender documents and submit your bid