Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC | ₹10.6 L | L1 | Accepted-AOC ok |
| 2 | L2₹10.7 LRejected-Finance VPO BAIYAPUR TEHSIL AND DISTT SONEPAT | SONEPAT | SONEPAT | HARYANA | ₹10.7 L | L2 | Rejected-Finance HIGHER |
| 3 | L3₹11.0 LRejected-Finance FLAT NO A103 POLICE OFFICERS MILTI STATE COOPERATIVE HOUSING SOCIETY LTD SECTOR 23 SONEPAT HARYANA 2021R213 | SONEPAT | SONEPAT | HARYANA | ₹11.0 L | L3 | Rejected-Finance HIGHER |
| 4 | L4₹11.2 LRejected-Finance VPO BHATGAON TEHSIL AND DISTT SONEPAT 131001 | SONEPAT | SONEPAT | HARYANA | 131001 | ₹11.2 L | L4 | Rejected-Finance HIGHER |
| 5 | L5₹11.5 LRejected-Finance 2ND FLOOR ANAND NAGAR VIKAS PURI COLONY 2025R23149 | SONEPAT | SONEPAT | HARYANA | ₹11.5 L | L5 | Rejected-Finance HIGHER |
| Sl No | Description | Qty | Unit | The Dabarpur Coop LC Society Ltd L3 | The Lakra Coop. L C Society L1 | The Kirtika Co.Op LC Society Ltd. Bhatgaon L4 | The Nirmala cooperative labour and construction society limited L6 | The Shakti Coop. L&C Society Ltd. L2 | The KS Infra Co-Op labour and Construction Society Limited Sonepat L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Plugin of Running sewer line for connection of new main sewer line to old main sewer line. | 5 | Each | 2,500 ₹12,500 | 3,500 ₹17,500 | 500 ₹2,500 | 4,500 ₹22,500 | 4,500 ₹22,500 | 600 ₹3,000 |
| 2.00 | Plug out of Running sewer line for connection of old main sewer line to new main sewer line. | 5 | Each | 2,500 ₹12,500 | 3,500 ₹17,500 | 500 ₹2,500 | 4,500 ₹22,500 | 4,500 ₹22,500 | 600 ₹3,000 |
| 3.00 | -providing and fixing MS jali reinforcement of galvanized steel wire complete in all respect | 50 | Sqm | 85 ₹4,250 | 80 ₹4,000 | 50 ₹2,500 | 150 ₹7,500 | 80 ₹4,000 | 800 ₹40,000 |
| 4.00 | Dewatering of water for connection purpose with pump having speed 1500 rpm and size 100 mm X 100 mm | 10 | Per Hour | 600 ₹6,000 | 800 ₹8,000 | 2,000 ₹20,000 | 900 ₹9,000 | 1,200 ₹12,000 | 200 ₹2,000 |
Tender Value
₹13.6 L
EMD Value
₹27,210
Closing Date
7 Jan 2026, 10:00 amClosed
Vishal Garg
Muncipal Corporation Sonipat
1169 - Estimate for Providing and laying new sewer line in mamchand school and jeevan vihar extension colony streets Murthal road in ward no. 5 under MC Sonipat.
2025_HRY_493480_1
20255BCF37B3 7A36 4942 AE15 91271593DA4B292ULB
Open Tender
Civil Works
140 days
Sonepat
2 documents required · 2 mandatory
₹1,000
₹27,210
Yes
12 Feb 2026
31 Dec 2025
7 Jan 2026
31 Dec 2025
7 Jan 2026
31 Dec 2025
31 Dec 2025 - 2 Jan 2026
Plugin of Running sewer line for connection of new main sewer line to old main sewer line.
Plug out of Running sewer line for connection of old main sewer line to new main sewer line.
-providing and fixing MS jali reinforcement of galvanized steel wire complete in all respect
Dewatering of water for connection purpose with pump having speed 1500 rpm and size 100 mm X 100 mm
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
[14.1]Dressing bed and preparation of sub grade for lining by mechanical/ mannual means [Through Rate]
[17.13]Granular Sub-Base (Mix in place) Construction of granular sub-base by providing Material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per technical clause 401 of MORT&H technical specifications [Through Rate]
[17.69.2]Interlocking Concrete Block Pavement 2. Providing and Laying 80 mm thick ISI marked Interlocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. [Through Rate]
[17.70]Removal of existing IPB by manual means and disposal of dismantled material with all lead and lift as per technical specification clause 202.3. [Through Rate]
[17.71]Relaying of available (removed and stacked) Interlocking Paver Block Pavement having thickness 100mm/80 mm/ 60 mm (average = 80mm) as per drawings and Technical Specification Clause 1504 [Through Rate]
[21.90.4.1]Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers up to the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge. 4.1. On 200 mm internal diameter pipe sewer - for 1.80 meters depth below ground level [Through Rate]
[22.218.1]Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 1. 250 mm Internal Diameter [Through Rate]
[22.218.2]Providing and Supplying of class SN 8 structured wall Polyethylene Piping system (Pipe with online/ offline coupler and elastomeric sealing ring) with non smooth external annular corrugated and smooth internal surface (double wall) for non-pressure underground sewerage and drainage application as confirm to IS 16098 (part II):2013 including transportation, frieght charges, inspection charges, loading, unloading, complete as specified and directed by Engineer In-Charge. 2. 300 mm Internal Diameter [Through Rate]
[22.219.1]Lowering, Laying and jointing of class SN 8 structured wall (External Annular Corrugated and Smooth Internal Surface Polyethylene Piping and fitting with the help of coupler(online/ offline) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot end, lowering the same into the trench, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient, depth and alignment, testing the water tightness of the joints, ensuring the continuity tests of specified pipe segment etc. complete as per drawing, specification and detailed engineering, including cartage of pipes and fitting etc. as per direction of Engineer-in-charge. 1. 1250 mm Internal Diameter [Through Rate]
[22.219.2]Lowering, Laying and jointing of class SN 8 structured wall (External Annular Corrugated and Smooth Internal Surface Polyethylene Piping and fitting with the help of coupler(online/ offline) attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot end, lowering the same into the trench, laying on the lower bedding (constructed at bottom of trenches) at prescribed gradient, depth and alignment, testing the water tightness of the joints, ensuring the continuity tests of specified pipe segment etc. complete as per drawing, specification and detailed engineering, including cartage of pipes and fitting etc. as per direction of Engineer-in-charge. 2. 300 mm Internal Diameter [Through Rate]
[22.85.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes [Through Rate]
[3.1.18]By Mechanical Transport including loading, unloading and stacking 18. Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead up to 10 km for all lifts, complete as per directions of Engineer-in-charge. [Rate]
[4.19.1.2]Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth up to 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m : 1.2. Ordinary rock : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia [Through Rate]
[4.20]Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre) [Through Rate]
[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]
[6.1.7]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 7. 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) [Through Rate]
[9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter [Through Rate]
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_571875.xls
BOQ • 0.33 MB
AD0146387.pdf
Additional Documents • 1.48 MB
Download all tender documents and submit your bid